Carlos Dias Maciel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carlos Dias Maciel has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Rogério Scalassara
Universidade Tecnológica Federal do Paraná (UTFPR), Cornélio Procópio, Brazil
6 shared publications José Carlos Pereira
2 shared publicationsMaría Eugenia Dajer
School of Engineering of São Carlos and Institute of Physics of São Carlos, University of São Paulo, Avenida Trabalhador São-carlense, 400, São Carlos 13566-590, Brazil
2 shared publications- Claudia Smaniotto Barin
Universidade Federal de Santa Maria
1 shared publication - Dimas Augusto Morozin Zaia
Universidade Estadual de Londrina
1 shared publication Edgar Matsuo Tsuzuki
Universidade Estadual de Londrina
1 shared publication
Latest Publications
- 22 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 28 (5) , 30-34
Predictability analysis of voice signals
This paper, proposes a method of voice signal analysis based on predictability measures. The objective is the differentiation of three groups of signals: healthy, nodules on the vocal folds, and Reinke's edema. This method is a slight reformulation of a measure called predictive power (PP) that uses the relative entropy between the signal and its prediction error to capture information about the predictability of the patient's voice production system. A wavelet decomposition model provides the predictions. The results obtained for the healthy group were substantially higher than those of the pathologic groups. This decrease of predictability may be interpreted as an indication of the increase of intricacy and irregularity associated with the studied larynx pathologies.
- 22 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 28 (5) , 30-34
Predictability analysis of voice signals
This paper, proposes a method of voice signal analysis based on predictability measures. The objective is the differentiation of three groups of signals: healthy, nodules on the vocal folds, and Reinke's edema. This method is a slight reformulation of a measure called predictive power (PP) that uses the relative entropy between the signal and its prediction error to capture information about the predictability of the patient's voice production system. A wavelet decomposition model provides the predictions. The results obtained for the healthy group were substantially higher than those of the pathologic groups. This decrease of predictability may be interpreted as an indication of the increase of intricacy and irregularity associated with the studied larynx pathologies.
- 1 January 2009
- Published by Elsevier in Applied Mathematics and Computation
- Vol. 207 (1) , 95-108
Relative entropy measures applied to healthy and pathological voice characterization
- 1 January 2009
- Published by Elsevier in Applied Mathematics and Computation
- Vol. 207 (1) , 95-108
Relative entropy measures applied to healthy and pathological voice characterization
- Open Access
- 1 January 2008
- Published by FapUNIFESP (SciELO) in Pesquisa Agropecuária Brasileira
- Vol. 43 (1) , 83-91
Conjunto mínimo de parâmetros para avaliação da microbiota do solo e da fixação biológica do nitrogênio pela soja
O objetivo deste trabalho foi avaliar e validar um conjunto mínimo de parâmetros para o monitoramento, em campo, da microbiota do solo e da fixação biológica do N2 (FBN) pela soja. Os ensaios foram conduzidos em áreas de plantios comerciais (safra 2002/2003) e experimentais (safra 2004/2005), em blocos ao acaso. O C e o N da biomassa microbiana (CBM e NBM) mostraram-se adequados para a avaliação quantitativa da microbiota do solo e ambos os parâmetros foram correlacionados significativamente, portanto, apenas um deles precisa ser determinado. Foram obtidas correlações positivas e significativas entre a massa da parte aérea seca das plantas (MPAS) e o CBM e o NBM. A análise do DNA total do solo por eletroforese em géis desnaturantes (DGGE) detectou alterações qualitativas na microbiota do solo, relacionadas à homogeneidade da área e a diferenças entre tratamentos, áreas e coletas. A massa de nódulos secos (MNS) foi o melhor parâmetro para a avaliação da nodulação. Correlações significativas foram constatadas entre a MPAS e o N total acumulado na parte aérea (NTPA). Resultados semelhantes foram observados entre a MPAS e o N de ureídos (NTU). O monitoramento da FBN pela soja pode ser realizado apenas pela determinação da MNS e da MPAS.
- 1 January 2008
- Published by FapUNIFESP (SciELO) in Pesquisa Agropecuária Brasileira
- Vol. 43 (1) , 83-91
Open AccessConjunto mínimo de parâmetros para avaliação da microbiota do solo e da fixação biológica do nitrogênio pela soja
O objetivo deste trabalho foi avaliar e validar um conjunto mínimo de parâmetros para o monitoramento, em campo, da microbiota do solo e da fixação biológica do N2 (FBN) pela soja. Os ensaios foram conduzidos em áreas de plantios comerciais (safra 2002/2003) e experimentais (safra 2004/2005), em blocos ao acaso. O C e o N da biomassa microbiana (CBM e NBM) mostraram-se adequados para a avaliação quantitativa da microbiota do solo e ambos os parâmetros foram correlacionados significativamente, portanto, apenas um deles precisa ser determinado. Foram obtidas correlações positivas e significativas entre a massa da parte aérea seca das plantas (MPAS) e o CBM e o NBM. A análise do DNA total do solo por eletroforese em géis desnaturantes (DGGE) detectou alterações qualitativas na microbiota do solo, relacionadas à homogeneidade da área e a diferenças entre tratamentos, áreas e coletas. A massa de nódulos secos (MNS) foi o melhor parâmetro para a avaliação da nodulação. Correlações significativas foram constatadas entre a MPAS e o N total acumulado na parte aérea (NTPA). Resultados semelhantes foram observados entre a MPAS e o N de ureídos (NTU). O monitoramento da FBN pela soja pode ser realizado apenas pela determinação da MNS e da MPAS.
- Open Access
Proposal for an Ultrasonic Tool to Monitor the Osseointegration of Dental Implants
The longevity of dental implants depends on osseointegration, which providesload-bearing capacity without putting the prosthesis at risk from micromotions at theimplant-bone interface. This research involved an analysis of the viability of an ultrasonicevaluation tool to quantify osseointegration. Ultrasonic transmission is directly dependenton the difference between the acoustic impedance of materials in intimate contact witheach other. The closer their acoustic impedances the more intense their transmission.Therefore, an analysis of the ultrasonic echoes would presumably allow for a quantitativeevaluation of the bone tissue that has grown into the pores of the implant. In addition, theliterature reports that bone fracture healing can be accelerated by the application of acontrolled low-amplitude mechanical stimulus on the site of the lesion. In fact, acousticpressure waves of low-intensity pulsed ultrasound are reportedly a secure technique forpromoting mechanical stimulus without impairing the healing process. Many experimentaland clinical trials have confirmed that daily transcutaneous ultrasound applications on theinjured site are beneficial to the enhancement of fractured bone. This proposal aims tobring together the characteristics of ultrasound propagation and the positive effect ofultrasound on bone growth into a single tool that quantitatively monitors the evolution ofthe osseointegration process. The viability of a device with these features was investigatedthrough simulations and experimentally. The initial simulations were conducted to explorethe influence of waveguide shapes on the tool’s sensitivity to changes in the implantsupporting media. The waveguides were designed in two parts, one consisting of a screw-shaped part to attach to the implant and the other a conical or step-shaped part to which the ultrasonic source was fixed in the first simulations. The step-shaped waveguide proved to be the more sensitive; intermediate stages of the osseointegration process were simulated and experiments were conducted with the step-shaped aluminum waveguide attached to a cylindrical aluminum nut embedded at different depths, so that the results obtained were only due to lateral attachment of the parts. These devices indicated that the transmission of ultrasound through the lateral surface of the implant by dilatational waves could render this tool suitable for monitoring the osseointegration of dental implants.
Open AccessProposal for an Ultrasonic Tool to Monitor the Osseointegration of Dental Implants
The longevity of dental implants depends on osseointegration, which providesload-bearing capacity without putting the prosthesis at risk from micromotions at theimplant-bone interface. This research involved an analysis of the viability of an ultrasonicevaluation tool to quantify osseointegration. Ultrasonic transmission is directly dependenton the difference between the acoustic impedance of materials in intimate contact witheach other. The closer their acoustic impedances the more intense their transmission.Therefore, an analysis of the ultrasonic echoes would presumably allow for a quantitativeevaluation of the bone tissue that has grown into the pores of the implant. In addition, theliterature reports that bone fracture healing can be accelerated by the application of acontrolled low-amplitude mechanical stimulus on the site of the lesion. In fact, acousticpressure waves of low-intensity pulsed ultrasound are reportedly a secure technique forpromoting mechanical stimulus without impairing the healing process. Many experimentaland clinical trials have confirmed that daily transcutaneous ultrasound applications on theinjured site are beneficial to the enhancement of fractured bone. This proposal aims tobring together the characteristics of ultrasound propagation and the positive effect ofultrasound on bone growth into a single tool that quantitatively monitors the evolution ofthe osseointegration process. The viability of a device with these features was investigatedthrough simulations and experimentally. The initial simulations were conducted to explorethe influence of waveguide shapes on the tool’s sensitivity to changes in the implantsupporting media. The waveguides were designed in two parts, one consisting of a screw-shaped part to attach to the implant and the other a conical or step-shaped part to which the ultrasonic source was fixed in the first simulations. The step-shaped waveguide proved to be the more sensitive; intermediate stages of the osseointegration process were simulated and experiments were conducted with the step-shaped aluminum waveguide attached to a cylindrical aluminum nut embedded at different depths, so that the results obtained were only due to lateral attachment of the parts. These devices indicated that the transmission of ultrasound through the lateral surface of the implant by dilatational waves could render this tool suitable for monitoring the osseointegration of dental implants.
- Open Access
- 30 January 2004
- Published by Universidade Estadual de Londrina in Semina: Ciências Exatas e Tecnológicas
- Vol. 25 (2) , 135
Minimização de ruído eletroquímico usando processamento digital de sinais
- 30 January 2004
- Published by Universidade Estadual de Londrina in Semina: Ciências Exatas e Tecnológicas
- Vol. 25 (2) , 135
Open AccessMinimização de ruído eletroquímico usando processamento digital de sinais
- Open Access
- 15 July 2002
- Published by Universidade Estadual de Londrina in Semina: Ciências Exatas e Tecnológicas
- Vol. 23 (1) , 9
Medida de Velocidade de Propagação do Som e Espessura de Materiais por Ultra-som
- 15 July 2002
- Published by Universidade Estadual de Londrina in Semina: Ciências Exatas e Tecnológicas
- Vol. 23 (1) , 9
Open AccessMedida de Velocidade de Propagação do Som e Espessura de Materiais por Ultra-som