Xuecai Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuecai Tan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Dandan Zhao
Baise University
4 shared publicationsLi Liu
Guangxi Key Laboratory of Chemistry and Engineering of Forest Products, Key Laboratory of Chemical and Biological Transforming Process in the University of Guangxi, School of Chemistry and Chemical Engineering, Guangxi University for Nationalities, Nanning 530008, P. R. China tel.: +86-771-3264166; fax: +86-771-3260558
3 shared publicationsZaiyin Huang
Guangxi Key Laboratory of Chemistry and Engineering of Forest Products, Key Laboratory of Chemical and Biological Transforming Process in the University of Guangxi, School of Chemistry and Chemical Engineering, Guangxi University for Nationalities, Nanning 530008, P. R. China tel.: +86-771-3264166; fax: +86-771-3260558
3 shared publicationsFuhou Lei
Guangxi Key Laboratory of Chemistry and Engineering of Forest Products, Key Laboratory of Chemical and Biological Transforming Process in the University of Guangxi, School of Chemistry and Chemical Engineering, Guangxi University for Nationalities, Nanning 530008, P. R. China tel.: +86-771-3264166; fax: +86-771-3260558
2 shared publicationsJinlei Zhang
College of Chemistry and Ecological Engineering, Guangxi University for Nationalities, Nanning 53, P. R. China
2 shared publicationsShengwei Tan
College of Chemistry and Ecological Engineering, Guangxi University for Nationalities, Nanning 53, P. R. China
2 shared publications
Latest Publications
- 29 October 2014
- Published by Springer Nature in Chemical Research in Chinese Universities
- Vol. 30 (6) , 905-909
Electrochemical reaction mechanism of phenacetin at a carboxylated multiwall carbon nanotube modified electrode and its analytical applications
- 29 October 2014
- Published by Springer Nature in Chemical Research in Chinese Universities
- Vol. 30 (6) , 905-909
Electrochemical reaction mechanism of phenacetin at a carboxylated multiwall carbon nanotube modified electrode and its analytical applications
- 27 June 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (7) , 1647-1654
Electrochemical Sensor Based on Molecularly Imprinted Polymer Film Prepared with Functional Abietic‐Type Acids as Cross‐Linker for the Determination of Quinine
A novel cross‐linker (functional abietic‐type acids) for preparing highly sensitive, molecularly imprinted sensors was proposed for quinine determination. A MIP film was created on a glassy carbon electrode for determination of quinine using free radical polymerization method. The modification procedure was characterized via electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The interaction between functional monomer and target molecule was observed by UV spectrometric methods. Under the optimal experimental conditions, the peak currents were proportional to the concentrations of quinine in the range from 8.0×10−7 to 2.6×10−4 M with a detection limit of 2.0×10−8 M. Meanwhile the prepared sensor showed sensitive and selective binding sites for quinine. Determination of quinine in tonic water showed good recovery.
- 27 June 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (7) , 1647-1654
Electrochemical Sensor Based on Molecularly Imprinted Polymer Film Prepared with Functional Abietic‐Type Acids as Cross‐Linker for the Determination of Quinine
A novel cross‐linker (functional abietic‐type acids) for preparing highly sensitive, molecularly imprinted sensors was proposed for quinine determination. A MIP film was created on a glassy carbon electrode for determination of quinine using free radical polymerization method. The modification procedure was characterized via electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The interaction between functional monomer and target molecule was observed by UV spectrometric methods. Under the optimal experimental conditions, the peak currents were proportional to the concentrations of quinine in the range from 8.0×10−7 to 2.6×10−4 M with a detection limit of 2.0×10−8 M. Meanwhile the prepared sensor showed sensitive and selective binding sites for quinine. Determination of quinine in tonic water showed good recovery.
- 1 January 2012
- Published by Shanghai Institute of Organic Chemistry in Acta Chimica Sinica
- Vol. 70 (09) , 1088-1094
Electrochemical Sensor for the Determination of Theophylline Based on Molecularly Imprinted Polymer with Ethylene Glycol Maleic Rosinate Acrylate as Cross-linker
A novel electrochemical sensor for the determination of theophylline based on ethylene glycol maleic rosinate acrylate as the cross linking agent and acrylic acid as functional monomer was fabricated by molecularly imprinted technology.A molecularly imprinted polymers(MIPs) membrane was synthesized on the surface of a glassy carbon electrode in vacuum drying oven by free radical polymerization method.The electrochemical behavior of the membrane was characterized by cyclic voltammetry(CV),electrochemical impedance spectroscopy(EIS) and chronoamperometry.Under optimum conditions,it was found that the response of peak currents was linear to the concentration of theophylline in range of 2.00×10-7~3.45×10-4 mol/L(linear regression coefficient=0.9961) with the detection limit of 1.00×10-7 mol/L.The sensor not only has high selectivity,but also shows good stability and reproducibility.The sensor was applied to the determination of theophylline in theophylline sustained release tablets samples with recovery ranging from 95.6% to 103.8%.
- 1 January 2012
- Published by Shanghai Institute of Organic Chemistry in Acta Chimica Sinica
- Vol. 70 (09) , 1088-1094
Electrochemical Sensor for the Determination of Theophylline Based on Molecularly Imprinted Polymer with Ethylene Glycol Maleic Rosinate Acrylate as Cross-linker
A novel electrochemical sensor for the determination of theophylline based on ethylene glycol maleic rosinate acrylate as the cross linking agent and acrylic acid as functional monomer was fabricated by molecularly imprinted technology.A molecularly imprinted polymers(MIPs) membrane was synthesized on the surface of a glassy carbon electrode in vacuum drying oven by free radical polymerization method.The electrochemical behavior of the membrane was characterized by cyclic voltammetry(CV),electrochemical impedance spectroscopy(EIS) and chronoamperometry.Under optimum conditions,it was found that the response of peak currents was linear to the concentration of theophylline in range of 2.00×10-7~3.45×10-4 mol/L(linear regression coefficient=0.9961) with the detection limit of 1.00×10-7 mol/L.The sensor not only has high selectivity,but also shows good stability and reproducibility.The sensor was applied to the determination of theophylline in theophylline sustained release tablets samples with recovery ranging from 95.6% to 103.8%.
- 15 October 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (1) , 110-115
A novel hydrogen peroxide biosensor based on sol–gel poly (vinyl alcohol) (PVA)/(titanium dioxide)TiO 2 hybrid material
A novel hydrogen peroxide biosensor has been fabricated based on Hb entrapped poly(vinyl alcohol) (PVA)/Titanium dioxide (TiO2) hybrid material. Multi-walled carbon nanotubes (MWCNTs) were then dispersed into the composite matrix. It was found that such hybrid material could retain the native biocatalytic activity of the entrapped Hb by electrochemical experiments. In addition, MWCNTs enhanced catalytic performance of hydrogen peroxide and promoted electronic transfer. Effects of some experimental variables such as the amount of MWCNTs, concentration of enzyme, amounts of modifier on the current response of the biosensor were investigated. A linear calibration graph was obtained in the concentration range of H2O2 from 0.5 to 2.7 μM (linear regression coefficient = 0.997) with a detection limit of 0.01 μM (S/N = 3). The apparent Michaelis–Menten constant Km was 0.997 μM. The biosensor displayed excellent repeatability, high sensitivity, long-term stability, and good selectivity. The recovery of H2O2 in samples was testified with satisfactory results.
- 15 October 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (1) , 110-115
A novel hydrogen peroxide biosensor based on sol–gel poly (vinyl alcohol) (PVA)/(titanium dioxide)TiO 2 hybrid material
A novel hydrogen peroxide biosensor has been fabricated based on Hb entrapped poly(vinyl alcohol) (PVA)/Titanium dioxide (TiO2) hybrid material. Multi-walled carbon nanotubes (MWCNTs) were then dispersed into the composite matrix. It was found that such hybrid material could retain the native biocatalytic activity of the entrapped Hb by electrochemical experiments. In addition, MWCNTs enhanced catalytic performance of hydrogen peroxide and promoted electronic transfer. Effects of some experimental variables such as the amount of MWCNTs, concentration of enzyme, amounts of modifier on the current response of the biosensor were investigated. A linear calibration graph was obtained in the concentration range of H2O2 from 0.5 to 2.7 μM (linear regression coefficient = 0.997) with a detection limit of 0.01 μM (S/N = 3). The apparent Michaelis–Menten constant Km was 0.997 μM. The biosensor displayed excellent repeatability, high sensitivity, long-term stability, and good selectivity. The recovery of H2O2 in samples was testified with satisfactory results.
- Open Access
Amperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on a Glassy Carbon Electrode Modified with Fe3O4/Chitosan Core-Shell Microspheres
Novel magnetic Fe3O4/chitosan (CS) microspheres were prepared using magnetic Fe3O4 nanoparticles and the natural macromolecule chitosan. Then, using an easy and effective hemoglobin (Hb) immobilization method, an innovative biosensor with a Fe3O4/CS-Hb-Fe3O4/CS “sandwich” configuration was constructed. This biosensor had a fast (less than 10 s) response to H2O2 and excellent linear relationships were obtained in the concentration range of 5.0 × 10-5 to 1.8 × 10-3 M and 1.8 × 10-3 to 6.8 × 10-3 M with a detection limit of 4.0 × 10-6 M (s/n = 3) under the optimum conditions. The apparent Michaelis-Menten constant Km was 0.29 mM and it showed the excellent biological activity of the fixed Hb. Moreover, the biosensor had long-time stability and good reproducibility. The method was used to determine H2O2 concentration in real samples.
Open AccessAmperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on a Glassy Carbon Electrode Modified with Fe3O4/Chitosan Core-Shell Microspheres
Novel magnetic Fe3O4/chitosan (CS) microspheres were prepared using magnetic Fe3O4 nanoparticles and the natural macromolecule chitosan. Then, using an easy and effective hemoglobin (Hb) immobilization method, an innovative biosensor with a Fe3O4/CS-Hb-Fe3O4/CS “sandwich” configuration was constructed. This biosensor had a fast (less than 10 s) response to H2O2 and excellent linear relationships were obtained in the concentration range of 5.0 × 10-5 to 1.8 × 10-3 M and 1.8 × 10-3 to 6.8 × 10-3 M with a detection limit of 4.0 × 10-6 M (s/n = 3) under the optimum conditions. The apparent Michaelis-Menten constant Km was 0.29 mM and it showed the excellent biological activity of the fixed Hb. Moreover, the biosensor had long-time stability and good reproducibility. The method was used to determine H2O2 concentration in real samples.
- 30 June 2009
- Published by Wiley in Electroanalysis
- Vol. 21 (13) , 1514-1520
Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Immobilized on Fe3O4/Chitosan Modified Glassy Carbon Electrode
A new type of amperometric hydrogen peroxide biosensor was constructed based on horseradish peroxidase (HRP) immobilized on Fe3O4/chitosan modified glassy carbon electrode. The effects of some experimental variables such as the concentration of supporting electrolyte, pH, enzyme loading, the concentration of the mediator of methylene blue (MB) and the applied potential were investigated. The linear range of the calibration curve for H2O2 was 2.0×10−4–1.2×10−2 M with a detection limit of 1.0×10−4 M (S/N=3). The response time was less than 12 s. The apparent Michaelis‐Menten constant Km was 21.4 mM and it illustrated the excellent biological activity of the fixed enzyme. In addition, the biosensor had long‐time stability and good reproducibility. And this method has been used to determine H2O2 concentration in the real sample.
- 30 June 2009
- Published by Wiley in Electroanalysis
- Vol. 21 (13) , 1514-1520
Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Immobilized on Fe3O4/Chitosan Modified Glassy Carbon Electrode
A new type of amperometric hydrogen peroxide biosensor was constructed based on horseradish peroxidase (HRP) immobilized on Fe3O4/chitosan modified glassy carbon electrode. The effects of some experimental variables such as the concentration of supporting electrolyte, pH, enzyme loading, the concentration of the mediator of methylene blue (MB) and the applied potential were investigated. The linear range of the calibration curve for H2O2 was 2.0×10−4–1.2×10−2 M with a detection limit of 1.0×10−4 M (S/N=3). The response time was less than 12 s. The apparent Michaelis‐Menten constant Km was 21.4 mM and it illustrated the excellent biological activity of the fixed enzyme. In addition, the biosensor had long‐time stability and good reproducibility. And this method has been used to determine H2O2 concentration in the real sample.