Chan Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chan Du has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Le Liu
Shenzhen Key Laboratory of Advanced Layered Materials for Value-added Applications, Institute of Materials Research, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, P. R. China
3 shared publications - Yonghong He
Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
3 shared publications - Heng Shi
Southwest Petroleum University
1 shared publication - Hui Ma
Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
1 shared publication Jihua Guo
1 shared publication- Jihua Guo
Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
1 shared publication
Latest Publications
- Open Access
Multi-Channel Hyperspectral Fluorescence Detection Excited by Coupled Plasmon-Waveguide Resonance
We propose in this paper a biosensor scheme based on coupled plasmon-waveguide resonance (CPWR) excited fluorescence spectroscopy. A symmetrical structure that offers higher surface electric field strengths, longer surface propagation lengths and depths is developed to support guided waveguide modes for the efficient excitation of fluorescence. The optimal parameters for the sensor films are theoretically and experimentally investigated, leading to a detection limit of 0.1 nM (for a Cy5 solution). Multiplex analysis possible with the fluorescence detection is further advanced by employing the hyperspectral fluorescence technique to record the full spectra for every pixel on the sample plane. We demonstrate experimentally that highly overlapping fluorescence (Cy5 and Dylight680) can be distinguished and ratios of different emission sources can be determined accurately. This biosensor shows great potential for multiplex detections of fluorescence analytes.
Open AccessMulti-Channel Hyperspectral Fluorescence Detection Excited by Coupled Plasmon-Waveguide Resonance
We propose in this paper a biosensor scheme based on coupled plasmon-waveguide resonance (CPWR) excited fluorescence spectroscopy. A symmetrical structure that offers higher surface electric field strengths, longer surface propagation lengths and depths is developed to support guided waveguide modes for the efficient excitation of fluorescence. The optimal parameters for the sensor films are theoretically and experimentally investigated, leading to a detection limit of 0.1 nM (for a Cy5 solution). Multiplex analysis possible with the fluorescence detection is further advanced by employing the hyperspectral fluorescence technique to record the full spectra for every pixel on the sample plane. We demonstrate experimentally that highly overlapping fluorescence (Cy5 and Dylight680) can be distinguished and ratios of different emission sources can be determined accurately. This biosensor shows great potential for multiplex detections of fluorescence analytes.
- 1 October 2012
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 173, 218-224
Polarization interference interrogation of angular surface plasmon resonance sensors with wide metal film thickness tolerance
- 1 October 2012
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 173, 218-224
Polarization interference interrogation of angular surface plasmon resonance sensors with wide metal film thickness tolerance