Fayçal Meddour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fayçal Meddour has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Abdelghani Dendouga
Advanced Electronics Laboratory, University of Batna, Département d’Electronique, Université de Batna, 05 avenue Chahid Boukhlouf Mohamed, 05000 Batna, Algeria
2 shared publications - Samir Barra
Advanced Electronics Laboratory, Department of Electronics, University of Batna, Batna, Algeria
2 shared publications - Souhil Kouda
Department of Electronics, University of M'SILA, M'Sila, Algeria
2 shared publications - Zohir Dibi
Department of Electronics, University of Batna 2, Batna 05000, Algeria
2 shared publications Zohir Dibi
Department of Electronic University of Batna Batna 05000 Algeria
1 shared publication
Latest Publications
- Open Access
- 9 February 2017
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 11 (4) , 483-489
An efficient small size electromagnetic energy harvesting sensor for low‐DC‐power applications
An efficient small size electromagnetic energy harvesting sensor for low‐DC‐power applications is proposed. The sensor consists of two main parts: a dual polarisation square patch antenna used to collect the RF energy at a central frequency of 2.45 GHz, and two voltage doublers rectifier circuit for the RF‐to‐DC conversion. The overall size of the design is 50 × 50 × 6.2 mm 3 . Firstly, the antenna is designed using high‐frequency structure simulator software; followed by the design of the rectifier circuit in advanced design system. After simulations, a sensor prototype is fabricated using F4B as the antenna substrate. Measurements show that the sensor achieves a comparatively high maximum measured efficiency of 41% for a power level of −10 dBm. The sensor has a simple structure, it is compact sized, light weight, and presents a high RF‐to‐DC conversion efficiency for low‐RF‐power levels which can be used to charge different low‐DC‐power devices.
- 9 February 2017
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 11 (4) , 483-489
Open AccessAn efficient small size electromagnetic energy harvesting sensor for low‐DC‐power applications
An efficient small size electromagnetic energy harvesting sensor for low‐DC‐power applications is proposed. The sensor consists of two main parts: a dual polarisation square patch antenna used to collect the RF energy at a central frequency of 2.45 GHz, and two voltage doublers rectifier circuit for the RF‐to‐DC conversion. The overall size of the design is 50 × 50 × 6.2 mm 3 . Firstly, the antenna is designed using high‐frequency structure simulator software; followed by the design of the rectifier circuit in advanced design system. After simulations, a sensor prototype is fabricated using F4B as the antenna substrate. Measurements show that the sensor achieves a comparatively high maximum measured efficiency of 41% for a power level of −10 dBm. The sensor has a simple structure, it is compact sized, light weight, and presents a high RF‐to‐DC conversion efficiency for low‐RF‐power levels which can be used to charge different low‐DC‐power devices.
- 12 February 2011
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 9 (1) , 197-202
ANN modeling of a smart MEMS-based capacitive humidity sensor
- 12 February 2011
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 9 (1) , 197-202
ANN modeling of a smart MEMS-based capacitive humidity sensor
- Open Access
Optimization of TiO2 and PMAPTAC Concentrations of a Chemical Humidity Sensing Mechanism
This work aims to achieve an optimization of the TiO2 and PMAPTAC concentrations in a chemical resistive-type humidity sensing mechanism (RHSM). Our idea is based primarily on the modeling of the sensing mechanism. This model takes into account the parameters of non-linearity, hysteresis, temperature, frequency, substrate type. Furthermore, we investigated the TiO2 and PMAPTAC effects concentrations on the humidity sensing properties in our model. Secondly, we used the Matlab environment to create a database for an ideal model for the sensing mechanism, where the response of this ideal model is linear for any value of the above parameters. We have done the training to create an analytical model for the sensing mechanism (SM) and the ideal model (IM). After that, the SM and IM models are established on PSPICE simulator, where the output of the first is identical to the output of the RHSM used and the output of the last is the ideal response. Finally a “DIF bloc” was realized to make the difference between the SM output and the IM output, where this difference represents the linearity error, we take the minimum error, to identify the optimal TiO2 and PMAPTAC concentrations. However, a compromise between concentrations, humidity and temperature must be performed. The simulation results show that in low humidity and at temperature more than 25 °C, sample 1 is the best (in alumina substrate). However, the sample 9 represents the best sensor (in PET substrate) predominately for the lowest humidity and temperature.
Open AccessOptimization of TiO2 and PMAPTAC Concentrations of a Chemical Humidity Sensing Mechanism
This work aims to achieve an optimization of the TiO2 and PMAPTAC concentrations in a chemical resistive-type humidity sensing mechanism (RHSM). Our idea is based primarily on the modeling of the sensing mechanism. This model takes into account the parameters of non-linearity, hysteresis, temperature, frequency, substrate type. Furthermore, we investigated the TiO2 and PMAPTAC effects concentrations on the humidity sensing properties in our model. Secondly, we used the Matlab environment to create a database for an ideal model for the sensing mechanism, where the response of this ideal model is linear for any value of the above parameters. We have done the training to create an analytical model for the sensing mechanism (SM) and the ideal model (IM). After that, the SM and IM models are established on PSPICE simulator, where the output of the first is identical to the output of the RHSM used and the output of the last is the ideal response. Finally a “DIF bloc” was realized to make the difference between the SM output and the IM output, where this difference represents the linearity error, we take the minimum error, to identify the optimal TiO2 and PMAPTAC concentrations. However, a compromise between concentrations, humidity and temperature must be performed. The simulation results show that in low humidity and at temperature more than 25 °C, sample 1 is the best (in alumina substrate). However, the sample 9 represents the best sensor (in PET substrate) predominately for the lowest humidity and temperature.