Sabine Achmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sabine Achmann has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ralf Moos
University of Bayreuth
3 shared publications Martin Hämmerle
Functional Materials, University of Bayreuth, Universitätsstr. 30, 95440 Bayreuth, Germany
2 shared publicationsF. Hilbrig
University of Bayreuth
1 shared publicationM. Hermann
University of Bayreuth
1 shared publicationM. Hämmerle
University of Bayreuth
1 shared publication- Ruth Freitag
Process Biotechnology, Faculty of Engineering Sciences, University of Bayreuth, Bayreuth, Germany
1 shared publication
Latest Publications
- Open Access
Amperometric Enzyme-based Gas Sensor for Formaldehyde: Impact of Possible Interferences
In this work, cross-sensitivities and environmental influences on the sensitivityand the functionality of an enzyme-based amperometric sensor system for the directdetection of formaldehyde from the gas phase are studied. The sensor shows a linearresponse curve for formaldehyde in the tested range (0 - 15 vppm) with a sensitivity of1.9 μA/ppm and a detection limit of about 130 ppb. Cross-sensitivities by environmentalgases like CO2, CO, NO, H2, and vapors of organic solvents like methanol and ethanol areevaluated as well as temperature and humidity influences on the sensor system. The sensorshowed neither significant signal to CO, H2, methanol or ethanol nor to variations in thehumidity of the test gas. As expected, temperature variations had the biggest influence onthe sensor sensitivity with variations in the sensor signal of up to 10 % of the signal for 5vppm CH2O in the range of 25 - 30 °C.
Open AccessAmperometric Enzyme-based Gas Sensor for Formaldehyde: Impact of Possible Interferences
In this work, cross-sensitivities and environmental influences on the sensitivityand the functionality of an enzyme-based amperometric sensor system for the directdetection of formaldehyde from the gas phase are studied. The sensor shows a linearresponse curve for formaldehyde in the tested range (0 - 15 vppm) with a sensitivity of1.9 μA/ppm and a detection limit of about 130 ppb. Cross-sensitivities by environmentalgases like CO2, CO, NO, H2, and vapors of organic solvents like methanol and ethanol areevaluated as well as temperature and humidity influences on the sensor system. The sensorshowed neither significant signal to CO, H2, methanol or ethanol nor to variations in thehumidity of the test gas. As expected, temperature variations had the biggest influence onthe sensor sensitivity with variations in the sensor signal of up to 10 % of the signal for 5vppm CH2O in the range of 25 - 30 °C.
- 14 February 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (4) , 410-417
Amperometric Enzyme‐Based Biosensor for Direct Detection of Formaldehyde in the Gas Phase: Dependence on Electrolyte Composition
An enzymatic sensor detecting the analyte formaldehyde directly from the gas phase is under investigation. In contrast to existing systems, it enables the quantification of the analyte without prior sampling or accumulation and thus can be used as an online system to monitor the formaldehyde concentration in ambient air. The amperometric sensor depends on the enzymatic conversion of the analyte using formaldehyde dehydrogenase from P. putida [EC. 1.2.1.46] as the recognition element. It shows a linear response curve up to 15 ppm, with a detection limit of 0.03 pm (S/N=3). In order to optimize the sensor performance the electrolyte composition within the sensor was varied with respect to pH value, buffer concentration and the addition of Ca2+ and Mg2+ ions. To elucidate the influence of the mediator and the enzyme on the sensor performance the stability and activity of the electrochemical mediator and the enzyme alone was examined separately in these different electrolytes.
- 14 February 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (4) , 410-417
Amperometric Enzyme‐Based Biosensor for Direct Detection of Formaldehyde in the Gas Phase: Dependence on Electrolyte Composition
An enzymatic sensor detecting the analyte formaldehyde directly from the gas phase is under investigation. In contrast to existing systems, it enables the quantification of the analyte without prior sampling or accumulation and thus can be used as an online system to monitor the formaldehyde concentration in ambient air. The amperometric sensor depends on the enzymatic conversion of the analyte using formaldehyde dehydrogenase from P. putida [EC. 1.2.1.46] as the recognition element. It shows a linear response curve up to 15 ppm, with a detection limit of 0.03 pm (S/N=3). In order to optimize the sensor performance the electrolyte composition within the sensor was varied with respect to pH value, buffer concentration and the addition of Ca2+ and Mg2+ ions. To elucidate the influence of the mediator and the enzyme on the sensor performance the stability and activity of the electrochemical mediator and the enzyme alone was examined separately in these different electrolytes.