Paolo Dario
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paolo Dario has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Arianna Menciassi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
5 shared publications - Gastone Ciuti
Scuola Superiore Sant’Anna
4 shared publications - Franco Cecchi
IRCCS Fondazione Don Carlo Gnocchi, 50143 Florence, Italy
3 shared publications - Maria Chiara Carrozza
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera, Italy
3 shared publications - Giovanni Cioni
University of Pisa
2 shared publications - Giuseppe Tortora
Smart Medical Theatre Laboratory, ABzero, 56124 Pisa, Italy
2 shared publications
Latest Publications
- 11 February 2018
- Published by EasyChair
Precision Orthopaedic Surgery and Precision Orthopaedic Rehabilitation: A Novel Integrated Approach
Orthopaedic surgery is one of the first fields where robotic tools have been used and currently their use is growing thanks to the benefits and advantages of robotics. During the last two decades several robotic devices characterized by high accuracy during both the preoperative and intraoperative phases have been developed. The success of the rehabilitation treatment, which is complementary to the surgical phase, is crucial to the complete recovery of functions: however although computer-assisted navigation is more precise than the conventional techniques, it is still subject to errors. The aim of this study is to present an integrated approach, named "Precision Orthopaedic Surgery - Precision Orthopaedic Rehabilitation" (POS-POR), based on new applications for orthopaedic trauma treatment and rehabilitation.
- 11 February 2018
- Published by EasyChair
Precision Orthopaedic Surgery and Precision Orthopaedic Rehabilitation: A Novel Integrated Approach
Orthopaedic surgery is one of the first fields where robotic tools have been used and currently their use is growing thanks to the benefits and advantages of robotics. During the last two decades several robotic devices characterized by high accuracy during both the preoperative and intraoperative phases have been developed. The success of the rehabilitation treatment, which is complementary to the surgical phase, is crucial to the complete recovery of functions: however although computer-assisted navigation is more precise than the conventional techniques, it is still subject to errors. The aim of this study is to present an integrated approach, named "Precision Orthopaedic Surgery - Precision Orthopaedic Rehabilitation" (POS-POR), based on new applications for orthopaedic trauma treatment and rehabilitation.
- 1 June 2016
- Published by Elsevier in Research in Developmental Disabilities
- Vol. 53-54, 32-42
A pilot study on early home-based intervention through an intelligent baby gym (CareToy) in preterm infants
- 1 June 2016
- Published by Elsevier in Research in Developmental Disabilities
- Vol. 53-54, 32-42
A pilot study on early home-based intervention through an intelligent baby gym (CareToy) in preterm infants
- Open Access
- 2 May 2016
- Published by Springer Nature in Journal of Micro and Bio Robotics
- Vol. 11 (1-4) , 1-18
Frontiers of robotic endoscopic capsules: a review
Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.
- 2 May 2016
- Published by Springer Nature in Journal of Micro and Bio Robotics
- Vol. 11 (1-4) , 1-18
Open AccessFrontiers of robotic endoscopic capsules: a review
Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.
- Open Access
Inductive-Based Wireless Power Recharging System for an Innovative Endoscopic Capsule
Wireless capsule endoscopic devices are adopted for painless diagnosis of cancer and other diseases affecting the gastrointestinal tract as an alternative to traditional endoscopy. Although much work has been done to improve capsule performance in terms of active navigation, a major drawback is the limited available energy on board the capsule, usually provided by a battery. Another key shortcoming of active capsules is their limitation in terms of active functionalities and related costs. An inductive-based wireless recharging system for the development of an innovative capsule for colonoscopy is proposed in this paper; the aim is to provide fast off-line battery recovery for improving capsule lifecycle and thus reducing the cost of a single endoscopic procedure. The wireless recharging system has been properly designed to fit the dimensions of a capsule for colonoscopy but it can be applied to any biomedical devices to increase the number of times it can be used after proper sterilization. The current system is able to provide about 1 W power and is able to recharge the battery capsule in 20 min which is a reasonable time considering capsule operation time (10–15 min).
Open AccessInductive-Based Wireless Power Recharging System for an Innovative Endoscopic Capsule
Wireless capsule endoscopic devices are adopted for painless diagnosis of cancer and other diseases affecting the gastrointestinal tract as an alternative to traditional endoscopy. Although much work has been done to improve capsule performance in terms of active navigation, a major drawback is the limited available energy on board the capsule, usually provided by a battery. Another key shortcoming of active capsules is their limitation in terms of active functionalities and related costs. An inductive-based wireless recharging system for the development of an innovative capsule for colonoscopy is proposed in this paper; the aim is to provide fast off-line battery recovery for improving capsule lifecycle and thus reducing the cost of a single endoscopic procedure. The wireless recharging system has been properly designed to fit the dimensions of a capsule for colonoscopy but it can be applied to any biomedical devices to increase the number of times it can be used after proper sterilization. The current system is able to provide about 1 W power and is able to recharge the battery capsule in 20 min which is a reasonable time considering capsule operation time (10–15 min).
- Open Access
- 7 September 2015
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 14 (1) , 1-16
A new system for quantitative evaluation of infant gaze capabilities in a wide visual field
The visual assessment of infants poses specific challenges: many techniques that are used on adults are based on the patient’s response, and are not suitable for infants. Significant advances in the eye-tracking have made this assessment of infant visual capabilities easier, however, eye-tracking still requires the subject’s collaboration, in most cases and thus limiting the application in infant research. Moreover, there is a lack of transferability to clinical practice, and thus it emerges the need for a new tool to measure the paradigms and explore the most common visual competences in a wide visual field. This work presents the design, development and preliminary testing of a new system for measuring infant’s gaze in the wide visual field called CareToy C: CareToy for Clinics. The system is based on a commercial eye tracker (SmartEye) with six cameras running at 60 Hz, suitable for measuring an infant’s gaze. In order to stimulate the infant visually and audibly, a mechanical structure has been designed to support five speakers and five screens at a specific distance (60 cm) and angle: one in the centre, two on the right-hand side and two on the left (at 30° and 60° respectively). Different tasks have been designed in order to evaluate the system capability to assess the infant’s gaze movements during different conditions (such as gap, overlap or audio-visual paradigms). Nine healthy infants aged 4–10 months were assessed as they performed the visual tasks at random. We developed a system able to measure infant’s gaze in a wide visual field covering a total visual range of ±60° from the centre with an intermediate evaluation at ±30°. Moreover, the same system, thanks to different integrated software, was able to provide different visual paradigms (as gap, overlap and audio-visual) assessing and comparing different visual and multisensory sub-competencies. The proposed system endowed the integration of a commercial eye-tracker into a purposive setup in a smart and innovative way. The proposed system is suitable for measuring and evaluating infant’s gaze capabilities in a wide visual field, in order to provide quantitative data that can enrich the clinical assessment.
- 7 September 2015
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 14 (1) , 1-16
Open AccessA new system for quantitative evaluation of infant gaze capabilities in a wide visual field
The visual assessment of infants poses specific challenges: many techniques that are used on adults are based on the patient’s response, and are not suitable for infants. Significant advances in the eye-tracking have made this assessment of infant visual capabilities easier, however, eye-tracking still requires the subject’s collaboration, in most cases and thus limiting the application in infant research. Moreover, there is a lack of transferability to clinical practice, and thus it emerges the need for a new tool to measure the paradigms and explore the most common visual competences in a wide visual field. This work presents the design, development and preliminary testing of a new system for measuring infant’s gaze in the wide visual field called CareToy C: CareToy for Clinics. The system is based on a commercial eye tracker (SmartEye) with six cameras running at 60 Hz, suitable for measuring an infant’s gaze. In order to stimulate the infant visually and audibly, a mechanical structure has been designed to support five speakers and five screens at a specific distance (60 cm) and angle: one in the centre, two on the right-hand side and two on the left (at 30° and 60° respectively). Different tasks have been designed in order to evaluate the system capability to assess the infant’s gaze movements during different conditions (such as gap, overlap or audio-visual paradigms). Nine healthy infants aged 4–10 months were assessed as they performed the visual tasks at random. We developed a system able to measure infant’s gaze in a wide visual field covering a total visual range of ±60° from the centre with an intermediate evaluation at ±30°. Moreover, the same system, thanks to different integrated software, was able to provide different visual paradigms (as gap, overlap and audio-visual) assessing and comparing different visual and multisensory sub-competencies. The proposed system endowed the integration of a commercial eye-tracker into a purposive setup in a smart and innovative way. The proposed system is suitable for measuring and evaluating infant’s gaze capabilities in a wide visual field, in order to provide quantitative data that can enrich the clinical assessment.
- 21 July 2015
- Published by Springer Nature
- p. 553-561
Robot-Era Project: Preliminary Results on the System Usability
- 21 July 2015
- Published by Springer Nature
- p. 553-561
Robot-Era Project: Preliminary Results on the System Usability
- Open Access
MEMS Sensor Technologies for Human Centred Applications in Healthcare, Physical Activities, Safety and Environmental Sensing: A Review on Research Activities in Italy
Over the past few decades the increased level of public awareness concerning healthcare, physical activities, safety and environmental sensing has created an emerging need for smart sensor technologies and monitoring devices able to sense, classify, and provide feedbacks to users’ health status and physical activities, as well as to evaluate environmental and safety conditions in a pervasive, accurate and reliable fashion. Monitoring and precisely quantifying users’ physical activity with inertial measurement unit-based devices, for instance, has also proven to be important in health management of patients affected by chronic diseases, e.g., Parkinson’s disease, many of which are becoming highly prevalent in Italy and in the Western world. This review paper will focus on MEMS sensor technologies developed in Italy in the last three years describing research achievements for healthcare and physical activity, safety and environmental sensing, in addition to smart systems integration. Innovative and smart integrated solutions for sensing devices, pursued and implemented in Italian research centres, will be highlighted, together with specific applications of such technologies. Finally, the paper will depict the future perspective of sensor technologies and corresponding exploitation opportunities, again with a specific focus on Italy.
Open AccessMEMS Sensor Technologies for Human Centred Applications in Healthcare, Physical Activities, Safety and Environmental Sensing: A Review on Research Activities in Italy
Over the past few decades the increased level of public awareness concerning healthcare, physical activities, safety and environmental sensing has created an emerging need for smart sensor technologies and monitoring devices able to sense, classify, and provide feedbacks to users’ health status and physical activities, as well as to evaluate environmental and safety conditions in a pervasive, accurate and reliable fashion. Monitoring and precisely quantifying users’ physical activity with inertial measurement unit-based devices, for instance, has also proven to be important in health management of patients affected by chronic diseases, e.g., Parkinson’s disease, many of which are becoming highly prevalent in Italy and in the Western world. This review paper will focus on MEMS sensor technologies developed in Italy in the last three years describing research achievements for healthcare and physical activity, safety and environmental sensing, in addition to smart systems integration. Innovative and smart integrated solutions for sensing devices, pursued and implemented in Italian research centres, will be highlighted, together with specific applications of such technologies. Finally, the paper will depict the future perspective of sensor technologies and corresponding exploitation opportunities, again with a specific focus on Italy.
- 30 July 2014
- Published by Wiley in Journal of Mechanical Design
- Vol. 136 (10) , 105001
Design of a Compact Robotic Manipulator for Single-Port Laparoscopy
This paper presents the mechanical design of a novel surgical robotic platform, specifically developed for single-port laparoscopy (SPL). The greatest constraint is the small size of the skin incision through which the robot must operate. Several technical and technological challenges have been tackled to meet the stringent requirements imposed by the surgical procedure at hand. In this paper, a detailed mechanical description of the system is provided, fulfilling the necessary design requirements. The main outcome of this work is a compact, light-weight (total weight approximately 6 kg) and highly dexterous bimanual robot capable of overcoming the current drawbacks experienced in SPL when using traditional medical devices. The system has been assessed in terms of tracking accuracy, resulting in satisfactory and promising performance.
- 30 July 2014
- Published by Wiley in Journal of Mechanical Design
- Vol. 136 (10) , 105001
Design of a Compact Robotic Manipulator for Single-Port Laparoscopy
This paper presents the mechanical design of a novel surgical robotic platform, specifically developed for single-port laparoscopy (SPL). The greatest constraint is the small size of the skin incision through which the robot must operate. Several technical and technological challenges have been tackled to meet the stringent requirements imposed by the surgical procedure at hand. In this paper, a detailed mechanical description of the system is provided, fulfilling the necessary design requirements. The main outcome of this work is a compact, light-weight (total weight approximately 6 kg) and highly dexterous bimanual robot capable of overcoming the current drawbacks experienced in SPL when using traditional medical devices. The system has been assessed in terms of tracking accuracy, resulting in satisfactory and promising performance.
- Open Access
A Miniature Robot for Retraction Tasks under Vision Assistance in Minimally Invasive Surgery
Minimally Invasive Surgery (MIS) is one of the main aims of modern medicine. It enables surgery to be performed with a lower number and severity of incisions. Medical robots have been developed worldwide to offer a robotic alternative to traditional medical procedures. New approaches aimed at a substantial decrease of visible scars have been explored, such as Natural Orifice Transluminal Endoscopic Surgery (NOTES). Simple surgical tasks such as the retraction of an organ can be a challenge when performed from narrow access ports. For this reason, there is a continuous need to develop new robotic tools for performing dedicated tasks. This article illustrates the design and testing of a new robotic tool for retraction tasks under vision assistance for NOTES. The retraction robots integrate brushless motors to enable additional degrees of freedom to that provided by magnetic anchoring, thus improving the dexterity of the overall platform. The retraction robot can be easily controlled to reach the target organ and apply a retraction force of up to 1.53 N. Additional degrees of freedom can be used for smooth manipulation and grasping of the organ.
Open AccessA Miniature Robot for Retraction Tasks under Vision Assistance in Minimally Invasive Surgery
Minimally Invasive Surgery (MIS) is one of the main aims of modern medicine. It enables surgery to be performed with a lower number and severity of incisions. Medical robots have been developed worldwide to offer a robotic alternative to traditional medical procedures. New approaches aimed at a substantial decrease of visible scars have been explored, such as Natural Orifice Transluminal Endoscopic Surgery (NOTES). Simple surgical tasks such as the retraction of an organ can be a challenge when performed from narrow access ports. For this reason, there is a continuous need to develop new robotic tools for performing dedicated tasks. This article illustrates the design and testing of a new robotic tool for retraction tasks under vision assistance for NOTES. The retraction robots integrate brushless motors to enable additional degrees of freedom to that provided by magnetic anchoring, thus improving the dexterity of the overall platform. The retraction robot can be easily controlled to reach the target organ and apply a retraction force of up to 1.53 N. Additional degrees of freedom can be used for smooth manipulation and grasping of the organ.
- Open Access
A Modular Sensorized Mat for Monitoring Infant Posture
We present a novel sensorized mat for monitoring infant’s posture through the measure of pressure maps. The pressure-sensitive mat is based on an optoelectronic technology developed in the last few years at Scuola Superiore Sant’Anna: a soft silicone skin cover, which constitutes the mat, participates in the transduction principle and provides the mat with compliance. The device has a modular structure (with a minimum of one and a maximum of six sub-modules, and a total surface area of about 1 m2) that enables dimensional adaptation of the pressure-sensitive area to different specific applications. The system consists of on-board electronics for data collection, pre-elaboration, and transmission to a remote computing unit for analysis and posture classification. In this work we present a complete description of the sensing apparatus along with its experimental characterization and validation with five healthy infants.
Open AccessA Modular Sensorized Mat for Monitoring Infant Posture
We present a novel sensorized mat for monitoring infant’s posture through the measure of pressure maps. The pressure-sensitive mat is based on an optoelectronic technology developed in the last few years at Scuola Superiore Sant’Anna: a soft silicone skin cover, which constitutes the mat, participates in the transduction principle and provides the mat with compliance. The device has a modular structure (with a minimum of one and a maximum of six sub-modules, and a total surface area of about 1 m2) that enables dimensional adaptation of the pressure-sensitive area to different specific applications. The system consists of on-board electronics for data collection, pre-elaboration, and transmission to a remote computing unit for analysis and posture classification. In this work we present a complete description of the sensing apparatus along with its experimental characterization and validation with five healthy infants.