Bertrand Parvitte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bertrand Parvitte has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Virginie Zeninari
Equipe Spectrométrie Laser et Applications, GSMA, UMR 7331 CNRS, Université de Reims, BP 1039, 51687 Reims Cedex 2 – France
9 shared publications - Raphaël Vallon
Université de Reims Champagne-Ardenne, CNRS, GSMA UMR 7331, 51097 Reims, France
6 shared publications D. Courtois
Groupe de Spectrométrie Moléculaire et Atmosphérique, UMR CNRS 6089, UFR Sciences Exactes et Naturelles-Moulin de la Housse, BP 1039, 51687 Reims Cedex 2, France
3 shared publications- Florian Lecasse
Université de Reims Champagne-Ardenne, CNRS, GSMA UMR 7331, 51097 Reims, France
3 shared publications - Gérard Liger-Belair
Climate Impacts on Environment Laboratory (CIEL), Université de Reims Champagne-Ardenne, 51687 Reims, France
3 shared publications - Clara Cilindre
Université de Reims Champagne-Ardenne, CNRS, GSMA UMR 7331, 51097 Reims, France
2 shared publications
Latest Publications
- Open Access
- 7 July 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 443
Mapping gaseous ethanol in the headspace of wine glasses with an interband cascade laser sensor
- 7 July 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 443
Open AccessMapping gaseous ethanol in the headspace of wine glasses with an interband cascade laser sensor
- Open Access
- 8 April 2024
- Published by Universite de Bordeaux in OENO One
- Vol. 58 (2)
Mapping gas–phase CO2 in the headspace of two champagne glasses through infrared laser absorption spectroscopy: ŒnoXpert glass versus INAO glass
Champagne wines are complex hydroalcoholic mixtures supersaturated with dissolved carbon dioxide (CO2). During tasting, while serving the champagne in a glass and for the few minutes that follow, the headspace of the glass is progressively invaded by many chemical species, including gas–phase CO2 (likely to disrupt the perception of the wine’s bouquet beyond a certain threshold). Real-time monitoring of gas–phase CO2 was performed through tunable diode laser absorption spectroscopy along a multipoint network in the headspace of two champagne glasses showing distinct shapes and volume capacities (namely, the standard 21 cL INAO glass and the brand new 45 cL ŒnoXpert glass, designed by the Union of French Oenologists as a universal glass for the tasting of still and sparkling wines). From the start of the pouring stage and during the several minutes following, a kind of glass type-dependent CO2 footprint was revealed in the headspace of glasses, which was discussed based on the glass geometry and headspace volume. For an identical volume of champagne dispensed in both glasses, the headspace of ŒnoXpert was found to retain gaseous CO2 more efficiently over time than INAO glass does. Therefore, and extrapolating to aromatic compounds, the chemical space of the ŒnoXpert glass should be better preserved throughout the tasting than that of the INAO glass. Moreover, by reducing the volume of champagne served in the glass, the time-dependent CO2 footprint is significantly reduced in the glass headspace, thus reducing the risk of carbon dioxide burn during tasting.
- 8 April 2024
- Published by Universite de Bordeaux in OENO One
- Vol. 58 (2)
Open AccessMapping gas–phase CO2 in the headspace of two champagne glasses through infrared laser absorption spectroscopy: ŒnoXpert glass versus INAO glass
Champagne wines are complex hydroalcoholic mixtures supersaturated with dissolved carbon dioxide (CO2). During tasting, while serving the champagne in a glass and for the few minutes that follow, the headspace of the glass is progressively invaded by many chemical species, including gas–phase CO2 (likely to disrupt the perception of the wine’s bouquet beyond a certain threshold). Real-time monitoring of gas–phase CO2 was performed through tunable diode laser absorption spectroscopy along a multipoint network in the headspace of two champagne glasses showing distinct shapes and volume capacities (namely, the standard 21 cL INAO glass and the brand new 45 cL ŒnoXpert glass, designed by the Union of French Oenologists as a universal glass for the tasting of still and sparkling wines). From the start of the pouring stage and during the several minutes following, a kind of glass type-dependent CO2 footprint was revealed in the headspace of glasses, which was discussed based on the glass geometry and headspace volume. For an identical volume of champagne dispensed in both glasses, the headspace of ŒnoXpert was found to retain gaseous CO2 more efficiently over time than INAO glass does. Therefore, and extrapolating to aromatic compounds, the chemical space of the ŒnoXpert glass should be better preserved throughout the tasting than that of the INAO glass. Moreover, by reducing the volume of champagne served in the glass, the time-dependent CO2 footprint is significantly reduced in the glass headspace, thus reducing the risk of carbon dioxide burn during tasting.
- Open Access
An Infrared Laser Sensor for Monitoring Gas-Phase CO2 in the Headspace of Champagne Glasses under Wine Swirling Conditions
In wine tasting, tasters commonly swirl their glasses before inhaling the headspace above the wine. However, the consequences of wine swirling on the chemical gaseous headspace inhaled by tasters are barely known. In champagne or sparkling wine tasting, starting from the pouring step, gas-phase carbon dioxide (CO) is the main gaseous species that progressively invades the glass headspace. We report the development of a homemade orbital shaker to replicate wine swirling and the upgrade of a diode laser sensor (DLS) dedicated to monitoring gas-phase CO in the headspace of champagne glasses under swirling conditions. We conduct a first overview of gas-phase CO monitoring in the headspace of a champagne glass, starting from the pouring step and continuing for the next 5 min, with several 5 s swirling steps to replicate the natural orbital movement of champagne tasters. The first results show a sudden drop in the CO concentration in the glass headspace, probably triggered by the liquid wave traveling along the glass wall following the action of swirling the glass.Open AccessAn Infrared Laser Sensor for Monitoring Gas-Phase CO2 in the Headspace of Champagne Glasses under Wine Swirling Conditions
In wine tasting, tasters commonly swirl their glasses before inhaling the headspace above the wine. However, the consequences of wine swirling on the chemical gaseous headspace inhaled by tasters are barely known. In champagne or sparkling wine tasting, starting from the pouring step, gas-phase carbon dioxide (CO) is the main gaseous species that progressively invades the glass headspace. We report the development of a homemade orbital shaker to replicate wine swirling and the upgrade of a diode laser sensor (DLS) dedicated to monitoring gas-phase CO in the headspace of champagne glasses under swirling conditions. We conduct a first overview of gas-phase CO monitoring in the headspace of a champagne glass, starting from the pouring step and continuing for the next 5 min, with several 5 s swirling steps to replicate the natural orbital movement of champagne tasters. The first results show a sudden drop in the CO concentration in the glass headspace, probably triggered by the liquid wave traveling along the glass wall following the action of swirling the glass. - Open Access
Widely-Tunable Quantum Cascade-Based Sources for the Development of Optical Gas Sensors
Spectroscopic techniques based on Distributed FeedBack (DFB) Quantum Cascade Lasers (QCL) provide good results for gas detection in the mid-infrared region in terms of sensibility and selectivity. The main limitation is the QCL relatively low tuning range (~10 cm−1) that prevents from monitoring complex species with broad absorption spectra in the infrared region or performing multi-gas sensing. To obtain a wider tuning range, the first solution presented in this paper consists of the use of a DFB QCL array. Tuning ranges from 1335 to 1387 cm−1 and from 2190 to 2220 cm−1 have been demonstrated. A more common technique that will be presented in a second part is to implement a Fabry–Perot QCL chip in an external-cavity (EC) system so that the laser could be tuned on its whole gain curve. The use of an EC system also allows to perform Intra-Cavity Laser Absorption Spectroscopy, where the gas sample is placed within the laser resonator. Moreover, a technique only using the QCL compliance voltage technique can be used to retrieve the spectrum of the gas inside the cavity, thus no detector outside the cavity is needed. Finally, a specific scheme using an EC coherent QCL array can be developed. All these widely-tunable Quantum Cascade-based sources can be used to demonstrate the development of optical gas sensors.
Open AccessWidely-Tunable Quantum Cascade-Based Sources for the Development of Optical Gas Sensors
Spectroscopic techniques based on Distributed FeedBack (DFB) Quantum Cascade Lasers (QCL) provide good results for gas detection in the mid-infrared region in terms of sensibility and selectivity. The main limitation is the QCL relatively low tuning range (~10 cm−1) that prevents from monitoring complex species with broad absorption spectra in the infrared region or performing multi-gas sensing. To obtain a wider tuning range, the first solution presented in this paper consists of the use of a DFB QCL array. Tuning ranges from 1335 to 1387 cm−1 and from 2190 to 2220 cm−1 have been demonstrated. A more common technique that will be presented in a second part is to implement a Fabry–Perot QCL chip in an external-cavity (EC) system so that the laser could be tuned on its whole gain curve. The use of an EC system also allows to perform Intra-Cavity Laser Absorption Spectroscopy, where the gas sample is placed within the laser resonator. Moreover, a technique only using the QCL compliance voltage technique can be used to retrieve the spectrum of the gas inside the cavity, thus no detector outside the cavity is needed. Finally, a specific scheme using an EC coherent QCL array can be developed. All these widely-tunable Quantum Cascade-based sources can be used to demonstrate the development of optical gas sensors.
- 1 May 2016
- Published by Elsevier in Infrared Physics & Technology
- Vol. 76, 415-420
External cavity coherent quantum cascade laser array
- 1 May 2016
- Published by Elsevier in Infrared Physics & Technology
- Vol. 76, 415-420
External cavity coherent quantum cascade laser array
- Open Access
Challenges in the Design and Fabrication of a Lab-on-a-Chip Photoacoustic Gas Sensor
The favorable downscaling behavior of photoacoustic spectroscopy has provoked in recent years a growing interest in the miniaturization of photoacoustic sensors. The individual components of the sensor, namely widely tunable quantum cascade lasers, low loss mid infrared (mid-IR) waveguides, and efficient microelectromechanical systems (MEMS) microphones are becoming available in complementary metal–oxide–semiconductor (CMOS) compatible technologies. This paves the way for the joint processes of miniaturization and full integration. Recently, a prototype microsensor has been designed by the means of a specifically designed coupled optical-acoustic model. This paper discusses the new, or more intense, challenges faced if downscaling is continued. The first limitation in miniaturization is physical: the light source modulation, which matches the increasing cell acoustic resonance frequency, must be kept much slower than the collisional relaxation process. Secondly, from the acoustic modeling point of view, one faces the limit of validity of the continuum hypothesis. Namely, at some point, velocity slip and temperature jump boundary conditions must be used, instead of the continuous boundary conditions, which are valid at the macro-scale. Finally, on the technological side, solutions exist to realize a complete lab-on-a-chip, even if it remains a demanding integration problem.
Open AccessChallenges in the Design and Fabrication of a Lab-on-a-Chip Photoacoustic Gas Sensor
The favorable downscaling behavior of photoacoustic spectroscopy has provoked in recent years a growing interest in the miniaturization of photoacoustic sensors. The individual components of the sensor, namely widely tunable quantum cascade lasers, low loss mid infrared (mid-IR) waveguides, and efficient microelectromechanical systems (MEMS) microphones are becoming available in complementary metal–oxide–semiconductor (CMOS) compatible technologies. This paves the way for the joint processes of miniaturization and full integration. Recently, a prototype microsensor has been designed by the means of a specifically designed coupled optical-acoustic model. This paper discusses the new, or more intense, challenges faced if downscaling is continued. The first limitation in miniaturization is physical: the light source modulation, which matches the increasing cell acoustic resonance frequency, must be kept much slower than the collisional relaxation process. Secondly, from the acoustic modeling point of view, one faces the limit of validity of the continuum hypothesis. Namely, at some point, velocity slip and temperature jump boundary conditions must be used, instead of the continuous boundary conditions, which are valid at the macro-scale. Finally, on the technological side, solutions exist to realize a complete lab-on-a-chip, even if it remains a demanding integration problem.
- 1 January 2014
- Published by Optica Publishing Group
- p. JTu4A.32
Complete characterization of trace gas photoacoustic sensors using a finite element method
GSMA laser team reports simulations and optimization of a differential Helmholtz resonant photoacoustic gas sensor using a finite element method. The sensor characteristics and gas detection limit are estimated and compared to the experimental ones.
- 1 January 2014
- Published by Optica Publishing Group
- p. JTu4A.32
Complete characterization of trace gas photoacoustic sensors using a finite element method
GSMA laser team reports simulations and optimization of a differential Helmholtz resonant photoacoustic gas sensor using a finite element method. The sensor characteristics and gas detection limit are estimated and compared to the experimental ones.
- 1 December 2004
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 60 (14) , 3285-3290
Preliminary results of heterodyne detection with quantum-cascade lasers in the 9 μm region
- 1 December 2004
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 60 (14) , 3285-3290
Preliminary results of heterodyne detection with quantum-cascade lasers in the 9 μm region
- 1 April 2004
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 60 (5) , 1193-1213
Infrared laser heterodyne systems
- 1 April 2004
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 60 (5) , 1193-1213
Infrared laser heterodyne systems
- 1 May 2000
- Published by EDP Sciences in Journal de Physique IV
- Vol. 10 (PR8) , Pr8-197
Détection hétérodyne infrarouge et diodes lasers
- 1 May 2000
- Published by EDP Sciences in Journal de Physique IV
- Vol. 10 (PR8) , Pr8-197
Détection hétérodyne infrarouge et diodes lasers