Eric Finot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric Finot has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Eric Lesniewska
Laboratoire Interdisciplinaire Carnot de Bourgogne (LICB) UMR CNRS 6303 Université Bourgogne Europe Dijon Cedex France
3 shared publications - Thomas Thundat
University at Buffalo (SUNY)
3 shared publications - Alain Dereux
Laboratoire Interdisciplinaire Carnot de Bourgogne, CNRS-Université de Bourgogne, Dijon, France
2 shared publications - Alexandre Bouhelier
Université Bourgogne Europe, CNRS
2 shared publications Guillaume Legay
Laboratoire de Physique Université de Bourgogne, UMR CNRS 5027, F-21011 Dijon, France
2 shared publicationsJean-Emmanuel Clément
Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS, Université Bourgogne Franche-Comté, 21000 Dijon, France.
2 shared publications
Latest Publications
- Open Access
Experimental and Computational Approach to Fatigue Behavior of Polycrystalline Tantalum
This work provides an experimental and computational analysis of low cycle fatigue of a tantalum polycrystalline aggregate. The experimental results include strain field and lattice rotation field measurements at the free surface of a tension–compression test sample after 100, 1000, 2000, and 3000 cycles at % overall strain. They reveal the development of strong heterogeneites of strain, plastic slip activity, and surface roughness during cycling. Intergranular and transgranular cracks are observed after 5000 cycles. The Crystal Plasticity Finite Element simulation recording more than 1000 cycles confirms the large strain dispersion at the free surface and shows evidence of strong local ratcheting phenomena occurring in particular at some grain boundaries. The amount of ratcheting plastic strain at each cycle is used as the main ingredient of a new local fatigue crack initiation criterion.Open AccessExperimental and Computational Approach to Fatigue Behavior of Polycrystalline Tantalum
This work provides an experimental and computational analysis of low cycle fatigue of a tantalum polycrystalline aggregate. The experimental results include strain field and lattice rotation field measurements at the free surface of a tension–compression test sample after 100, 1000, 2000, and 3000 cycles at % overall strain. They reveal the development of strong heterogeneites of strain, plastic slip activity, and surface roughness during cycling. Intergranular and transgranular cracks are observed after 5000 cycles. The Crystal Plasticity Finite Element simulation recording more than 1000 cycles confirms the large strain dispersion at the free surface and shows evidence of strong local ratcheting phenomena occurring in particular at some grain boundaries. The amount of ratcheting plastic strain at each cycle is used as the main ingredient of a new local fatigue crack initiation criterion. - 22 November 2016
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (1) , 458-466
Spectral pointillism of enhanced Raman scattering for accessing structural and conformational information on single protein
Temporal fluctuations of surface enhanced Raman spectra stem from single protein subdomains providing access to structural and conformational information on protein.
- 22 November 2016
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (1) , 458-466
Spectral pointillism of enhanced Raman scattering for accessing structural and conformational information on single protein
Temporal fluctuations of surface enhanced Raman spectra stem from single protein subdomains providing access to structural and conformational information on protein.
- 24 August 2015
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 2 (9) , 1266-1271
Statistical and Fourier Analysis for In-line Concentration Sensitivity in Single Molecule Dynamic-SERS
- 24 August 2015
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 2 (9) , 1266-1271
Statistical and Fourier Analysis for In-line Concentration Sensitivity in Single Molecule Dynamic-SERS
- 27 March 2014
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 1 (2)
Dynamic and Static Manifestation of Molecular Absorption in Thin Films Probed by a Microcantilever
Simultaneous measurements of frequency shift and deformation of microcantilevers help in discerning between absorption-induced changes in swelling and elastic moduli of very thin films.
- 27 March 2014
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 1 (2)
Dynamic and Static Manifestation of Molecular Absorption in Thin Films Probed by a Microcantilever
Simultaneous measurements of frequency shift and deformation of microcantilevers help in discerning between absorption-induced changes in swelling and elastic moduli of very thin films.
- 1 April 2013
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 104, 289-293
Combined atomic force microscopy and spectroscopic ellipsometry applied to the analysis of lipid–protein thin films
- 1 April 2013
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 104, 289-293
Combined atomic force microscopy and spectroscopic ellipsometry applied to the analysis of lipid–protein thin films
- Open Access
Measurement of Mechanical Properties of Cantilever Shaped Materials
Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM) due to their extremely high sensitivity in measuring surface forces. The versatility of these probes, however, allows the sensing and measurement of a host of mechanical properties of various materials. Sensor parameters such as resonance frequency, quality factor, amplitude of vibration and bending due to a differential stress can all be simultaneously determined for a cantilever. When measuring the mechanical properties of materials, identifying and discerning the most influential parameters responsible for the observed changes in the cantilever response are important. We will, therefore, discuss the effects of various force fields such as those induced by mass loading, residual stress, internal friction of the material, and other changes in the mechanical properties of the microcantilevers. Methods to measure variations in temperature, pressure, or molecular adsorption of water molecules are also discussed. Often these effects occur simultaneously, increasing the number of parameters that need to be concurrently measured to ensure the reliability of the sensors. We therefore systematically investigate the geometric and environmental effects on cantilever measurements including the chemical nature of the underlying interactions. To address the geometric effects we have considered cantilevers with a rectangular or circular cross section. The chemical nature is addressed by using cantilevers fabricated with metals and/or dielectrics. Selective chemical etching, swelling or changes in Young’s modulus of the surface were investigated by means of polymeric and inorganic coatings. Finally to address the effect of the environment in which the cantilever operates, the Knudsen number was determined to characterize the molecule-cantilever collisions. Also bimaterial cantilevers with high thermal sensitivity were used to discern the effect of temperature variations. When appropriate, we use continuum mechanics, which is justified according to the ratio between the cantilever thickness and the grain size of the materials. We will also address other potential applications such as the ageing process of nuclear materials, building materials, and optical fibers, which can be investigated by monitoring their mechanical changes with time. In summary, by virtue of the dynamic response of a miniaturized cantilever shaped material, we present useful measurements of the associated elastic properties.
Open AccessMeasurement of Mechanical Properties of Cantilever Shaped Materials
Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM) due to their extremely high sensitivity in measuring surface forces. The versatility of these probes, however, allows the sensing and measurement of a host of mechanical properties of various materials. Sensor parameters such as resonance frequency, quality factor, amplitude of vibration and bending due to a differential stress can all be simultaneously determined for a cantilever. When measuring the mechanical properties of materials, identifying and discerning the most influential parameters responsible for the observed changes in the cantilever response are important. We will, therefore, discuss the effects of various force fields such as those induced by mass loading, residual stress, internal friction of the material, and other changes in the mechanical properties of the microcantilevers. Methods to measure variations in temperature, pressure, or molecular adsorption of water molecules are also discussed. Often these effects occur simultaneously, increasing the number of parameters that need to be concurrently measured to ensure the reliability of the sensors. We therefore systematically investigate the geometric and environmental effects on cantilever measurements including the chemical nature of the underlying interactions. To address the geometric effects we have considered cantilevers with a rectangular or circular cross section. The chemical nature is addressed by using cantilevers fabricated with metals and/or dielectrics. Selective chemical etching, swelling or changes in Young’s modulus of the surface were investigated by means of polymeric and inorganic coatings. Finally to address the effect of the environment in which the cantilever operates, the Knudsen number was determined to characterize the molecule-cantilever collisions. Also bimaterial cantilevers with high thermal sensitivity were used to discern the effect of temperature variations. When appropriate, we use continuum mechanics, which is justified according to the ratio between the cantilever thickness and the grain size of the materials. We will also address other potential applications such as the ageing process of nuclear materials, building materials, and optical fibers, which can be investigated by monitoring their mechanical changes with time. In summary, by virtue of the dynamic response of a miniaturized cantilever shaped material, we present useful measurements of the associated elastic properties.
- 31 October 2007
- Published by Elsevier in Ultramicroscopy
- Vol. 107 (10-11) , 1111-1117
Measurements of thickness dispersion in biolayers by scanning force microscopy and comparison with spectroscopic ellipsometry analysis
- 31 October 2007
- Published by Elsevier in Ultramicroscopy
- Vol. 107 (10-11) , 1111-1117
Measurements of thickness dispersion in biolayers by scanning force microscopy and comparison with spectroscopic ellipsometry analysis
- 29 March 2003
- Published by Elsevier in Ultramicroscopy
- Vol. 97 (1-4) , 441-449
Performance of interdigitated nanoelectrodes for electrochemical DNA biosensor
- 29 March 2003
- Published by Elsevier in Ultramicroscopy
- Vol. 97 (1-4) , 441-449
Performance of interdigitated nanoelectrodes for electrochemical DNA biosensor
- 1 March 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 20 (2) , 366-374
Atomic force microscopy investigation of a-C:H films prepared by plasma enhanced chemical vapor deposition for inertial confinement fusion experiments
This article deals with the development of a radio frequency plasma enhanced chemical vapor deposition thick film (175 μm thickness) derived from aliphatic chains, trans-2-butene, monomer mixed with hydrogen and various noble gases (helium, argon, and krypton). The main purpose was to engineer an amorphous hydrocarbon film (a-C:H) with low surface roughness of less than 20 nm, designed for use on an “ablator” in a new “MégaJoule” laser facility. Morphology and roughness were characterized by atomic force microscopy. An improvement of 70% is obtained by adding a bias on the substrate.
- 1 March 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 20 (2) , 366-374
Atomic force microscopy investigation of a-C:H films prepared by plasma enhanced chemical vapor deposition for inertial confinement fusion experiments
This article deals with the development of a radio frequency plasma enhanced chemical vapor deposition thick film (175 μm thickness) derived from aliphatic chains, trans-2-butene, monomer mixed with hydrogen and various noble gases (helium, argon, and krypton). The main purpose was to engineer an amorphous hydrocarbon film (a-C:H) with low surface roughness of less than 20 nm, designed for use on an “ablator” in a new “MégaJoule” laser facility. Morphology and roughness were characterized by atomic force microscopy. An improvement of 70% is obtained by adding a bias on the substrate.
- 1 May 2001
- Published by Elsevier in Solid State Ionics
- Vol. 141-142, 39-46
Correlating surface forces with surface reactivity of gypsum crystals by atomic force microscopy. Comparison with rheological properties of plaster
- 1 May 2001
- Published by Elsevier in Solid State Ionics
- Vol. 141-142, 39-46
Correlating surface forces with surface reactivity of gypsum crystals by atomic force microscopy. Comparison with rheological properties of plaster