Ferdinand Felder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ferdinand Felder has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
H. Zogg
Thin Film Physics Group, ETH Zurich, Technoparkstr. 1, 8005 Zurich, Switzerland
2 shared publications- Jürg Dual
ETH Zurich
2 shared publications - M. Fill
ETH Zurich, Zurich, Switzerland
2 shared publications M. Rahim
Thin Film Physics Group, ETH Zurich, Technoparkstr. 1, 8005 Zurich, Switzerland
2 shared publications- Niels Quack
Ėcole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
2 shared publications - A. Khiar
Thin Film Physics Group, ETH Zurich, CH-8005 Zurich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 31 January 2010
- Published by Elsevier in Physics Procedia
- Vol. 3 (2) , 1127-1131
Lead salt resonant cavity enhanced detector with MEMS mirror
- 31 January 2010
- Published by Elsevier in Physics Procedia
- Vol. 3 (2) , 1127-1131
Open AccessLead salt resonant cavity enhanced detector with MEMS mirror
- Open Access
- 31 January 2010
- Published by Elsevier in Physics Procedia
- Vol. 3 (2) , 1145-1148
Above Room Temperature Lead Salt VECSELs
- 31 January 2010
- Published by Elsevier in Physics Procedia
- Vol. 3 (2) , 1145-1148
Open AccessAbove Room Temperature Lead Salt VECSELs
- Open Access
Mid-Infrared Tunable Resonant Cavity Enhanced Detectors
Mid-infrared detectors that are sensitive only in a tunable narrow spectral band are presented. They are based on the Resonant Cavity Enhanced Detector (RCED) principle and employing a thin active region using IV-VI narrow gap semiconductor layers. A Fabry-Pérot cavity is formed by two mirrors. The active layer is grown onto one mirror, while the second mirror can be displaced. This changes the cavity length thus shifting the resonances where the detector is sensitive. Using electrostatically actuated MEMS micromirrors, a very compact tunable detector system has been fabricated. Mirror movements of more than 3 μm at 30V are obtained. With these mirrors, detectors with a wavelength tuning range of about 0.7 μm have been realized. Single detectors can be used in mid-infrared micro spectrometers, while a detector arrangement in an array makes it possible to realize Adaptive Focal Plane Arrays (AFPA).
Open AccessMid-Infrared Tunable Resonant Cavity Enhanced Detectors
Mid-infrared detectors that are sensitive only in a tunable narrow spectral band are presented. They are based on the Resonant Cavity Enhanced Detector (RCED) principle and employing a thin active region using IV-VI narrow gap semiconductor layers. A Fabry-Pérot cavity is formed by two mirrors. The active layer is grown onto one mirror, while the second mirror can be displaced. This changes the cavity length thus shifting the resonances where the detector is sensitive. Using electrostatically actuated MEMS micromirrors, a very compact tunable detector system has been fabricated. Mirror movements of more than 3 μm at 30V are obtained. With these mirrors, detectors with a wavelength tuning range of about 0.7 μm have been realized. Single detectors can be used in mid-infrared micro spectrometers, while a detector arrangement in an array makes it possible to realize Adaptive Focal Plane Arrays (AFPA).