R. Radetic
Research Subjects
R. Radetic has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dragan R. Milivojevic
Department of Informatics, Zeleni Bulevar 35, Mining and Metallurgy Institute, 19210 Bor, Serbia
2 shared publications - Dragan R. Milivojevic
Mining and Metallurgy Institute, Department of Informatics / Zeleni Bulevar 35, 19210 Bor, Serbia
1 shared publication - Marijana Pavlov-Kagadejev
Mining and Metallurgy Institute Bor Alberta Ajnštajna 1 19210 Bor Serbia
1 shared publication - V. Despotovic
University of Belgrade|Technical Faculty of Bor
1 shared publication
Latest Publications
- Open Access
- 1 January 2010
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 10 (1)
The New Bridge Converter Control Method
- 1 January 2010
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 10 (1)
Open AccessThe New Bridge Converter Control Method
- Open Access
- 1 January 2010
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 10 (1) , 22-24
Optimization of Measuring Current for Chopper Low Resistance Comparator
The article describes systematic error analysis for realized chopper low-resistance comparator. The objective was to determine optimal working conditions, considering limited resolution (about 10 nV) and resistance variation due to self-heating caused by increase of measuring current. The analysis and performances of realized chopper low-resistance comparator prototype instrument confirmed the initial assumptions of applied principles. The error for 1 A measuring current is 1.15 ppm in the measuring range of 10 mΩ. It is possible to use the same principle for calculation of optimal measuring current and measurement error in other measurement ranges, as well.
- 1 January 2010
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 10 (1) , 22-24
Open AccessOptimization of Measuring Current for Chopper Low Resistance Comparator
The article describes systematic error analysis for realized chopper low-resistance comparator. The objective was to determine optimal working conditions, considering limited resolution (about 10 nV) and resistance variation due to self-heating caused by increase of measuring current. The analysis and performances of realized chopper low-resistance comparator prototype instrument confirmed the initial assumptions of applied principles. The error for 1 A measuring current is 1.15 ppm in the measuring range of 10 mΩ. It is possible to use the same principle for calculation of optimal measuring current and measurement error in other measurement ranges, as well.
- Open Access
Chopper Stabilized Low Resistance Comparator
The paper describes an improvement of the chopper method for elimination of parasitic voltages in a low resistance comparison and measurement procedure. The basic circuit diagram along with a short description of the working principle are presented and the appropriate low resistance comparator prototype was designed and realized. Preliminary examinations confirm the possibility of measuring extremely low voltages. Very high accuracy in resistance comparison and measurement is achieved (0.08 ppm for 1,000 attempts). Some special critical features in the design are discussed and solutions for overcoming the problems are described.
Open AccessChopper Stabilized Low Resistance Comparator
The paper describes an improvement of the chopper method for elimination of parasitic voltages in a low resistance comparison and measurement procedure. The basic circuit diagram along with a short description of the working principle are presented and the appropriate low resistance comparator prototype was designed and realized. Preliminary examinations confirm the possibility of measuring extremely low voltages. Very high accuracy in resistance comparison and measurement is achieved (0.08 ppm for 1,000 attempts). Some special critical features in the design are discussed and solutions for overcoming the problems are described.