Naresh Kaul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Naresh Kaul has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
R. M. Khan
Khoula Hospital, Muscat, Oman
3 shared publicationsRashid M Khan
Department of Anaesthesia and ICU, Khoula Hospital, Muscat, Oman
3 shared publicationsA. Haris
Khoula Hospital, Muscat, Oman
2 shared publicationsP. K. Sharma
Khoula Hospital, Muscat, Oman
2 shared publicationsRashid M. Khan
Department of Anesthesia & ICU, Khoula Hospital, Muscat, Sultanate of Oman
2 shared publicationsRashid Manzoor Khan
Department of Anesthesia and ICU, Khoula Hospital, Oman Medical Specialty Board, Muscat, Sultanate of Oman
2 shared publications
Latest Publications
- Open Access
- 20 April 2022
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 66 (4) , 304-305
Iatrogenic catheterisation of subclavian artery while cannulating internal jugular vein
- 20 April 2022
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 66 (4) , 304-305
Open AccessIatrogenic catheterisation of subclavian artery while cannulating internal jugular vein
- Open Access
- 21 August 2018
- Published by Wiley in Anaesthesia
- Vol. 73 (9) , 1174
Throat packs inserted by anaesthetists
- 21 August 2018
- Published by Wiley in Anaesthesia
- Vol. 73 (9) , 1174
Open AccessThroat packs inserted by anaesthetists
- Open Access
- 5 December 2015
- Published by Brieflands in Anesthesiology and Pain Medicine
- Vol. 5 (6) , e32299
Comparison of Tracheal Intubation Using the Storz’s C-Mac D-bladeTM Video-Laryngoscope Aided by TruflexTM Articulating Stylet and the PortexTM Intubating Stylet
Background: Tracheal intubation using Storz’s C-Mac D-bladeTM videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade. Objectives: In this study, we hypothesized that TruflexTM articulating stylet with its ability to dynamically tailor the ETT shape to patients’ oropharyngeal anatomy would be better suited to the D-blade angulation and ease tracheal intubation compared to PortexTM intubation stylet. Patients and Methods: Following approval by the Ethical Issues Committee and informed consent, 218 ASA I and II patients of either sex were enrolled in this interventional, single-blind, randomized controlled trial. Tracheal intubation was performed following a uniform general anesthetic technique using the Storz’s C-Mac D-bladeTM videolaryngoscope aided by either TruflexTM articulating stylet or the PortexTM intubation stylet by an experienced anesthesiologist. The outcome measures included success or failure to intubate in the first attempt, total intubation time, hemodynamic disturbances, trauma if any and user satisfaction. Results: The number of patients in whom intubation was successful in the first attempt was significantly higher by using Truflex™ articulating stylet (99.1%) compared to PortexTM intubation stylet (90.0%; P-Value = 0.003). User satisfaction grade was significantly better while using TruflexTM articulating stylet (8.5 ± 0.88) compared to the PortexTM intubation stylet (8.23 ± 0.99; P-Value = 0.035). We did not observe any significant difference in total intubation time, hemodynamic disturbances or trauma. Conclusions: Storz’s C-Mac D-bladeTM videolaryngoscope provides grade I Cormack and Lehane’s glottic view in 99.1% patients. First attempt successful tracheal intubation and user satisfaction significantly improved by TruflexTM articulating stylet compared to the PortexTM intubation stylet. Keywords: C-Mac D-Blade; Video Laryngoscope; Truflex Articulating Stylet; Portex Intubating Stylet; Endo Tracheal Intubation
- 5 December 2015
- Published by Brieflands in Anesthesiology and Pain Medicine
- Vol. 5 (6) , e32299
Open AccessComparison of Tracheal Intubation Using the Storz’s C-Mac D-bladeTM Video-Laryngoscope Aided by TruflexTM Articulating Stylet and the PortexTM Intubating Stylet
Background: Tracheal intubation using Storz’s C-Mac D-bladeTM videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade. Objectives: In this study, we hypothesized that TruflexTM articulating stylet with its ability to dynamically tailor the ETT shape to patients’ oropharyngeal anatomy would be better suited to the D-blade angulation and ease tracheal intubation compared to PortexTM intubation stylet. Patients and Methods: Following approval by the Ethical Issues Committee and informed consent, 218 ASA I and II patients of either sex were enrolled in this interventional, single-blind, randomized controlled trial. Tracheal intubation was performed following a uniform general anesthetic technique using the Storz’s C-Mac D-bladeTM videolaryngoscope aided by either TruflexTM articulating stylet or the PortexTM intubation stylet by an experienced anesthesiologist. The outcome measures included success or failure to intubate in the first attempt, total intubation time, hemodynamic disturbances, trauma if any and user satisfaction. Results: The number of patients in whom intubation was successful in the first attempt was significantly higher by using Truflex™ articulating stylet (99.1%) compared to PortexTM intubation stylet (90.0%; P-Value = 0.003). User satisfaction grade was significantly better while using TruflexTM articulating stylet (8.5 ± 0.88) compared to the PortexTM intubation stylet (8.23 ± 0.99; P-Value = 0.035). We did not observe any significant difference in total intubation time, hemodynamic disturbances or trauma. Conclusions: Storz’s C-Mac D-bladeTM videolaryngoscope provides grade I Cormack and Lehane’s glottic view in 99.1% patients. First attempt successful tracheal intubation and user satisfaction significantly improved by TruflexTM articulating stylet compared to the PortexTM intubation stylet. Keywords: C-Mac D-Blade; Video Laryngoscope; Truflex Articulating Stylet; Portex Intubating Stylet; Endo Tracheal Intubation
- Open Access
- 15 September 2015
- Published by Wiley in Anaesthesia
- Vol. 70 (10) , 1214
Oxygenating patients during difficult videolaryngoscopy
- 15 September 2015
- Published by Wiley in Anaesthesia
- Vol. 70 (10) , 1214
Open AccessOxygenating patients during difficult videolaryngoscopy
- Open Access
- 1 January 2015
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 59 (5) , 323-5
Cisatracurium degradation: Intravenous fluid warmer the culprit?
Indian Journal of Anaesthesia, Official publication of Indian Society of Anaesthesiologists
- 1 January 2015
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 59 (5) , 323-5
Open AccessCisatracurium degradation: Intravenous fluid warmer the culprit?
Indian Journal of Anaesthesia, Official publication of Indian Society of Anaesthesiologists
- 28 January 2014
- Published by Wiley in Pediatric Anesthesia
- Vol. 24 (3) , 339-340
A pathfinder technique of laryngeal mask airway placement in an infant with severe contracture of face, neck, and chest
- 28 January 2014
- Published by Wiley in Pediatric Anesthesia
- Vol. 24 (3) , 339-340
A pathfinder technique of laryngeal mask airway placement in an infant with severe contracture of face, neck, and chest
- Open Access
- 16 September 2013
- Published by Springer Nature in Trials
- Vol. 14 (1) , 298
Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices, the insertion and advancement of the endotracheal tube may be prolonged and occasionally fail as it does not conform to the enhanced angulation of the blade. To overcome this handicap, it is recommended to use a pre-shaped, styleted tracheal tube during intubation. Unfortunately, these malleable rigid stylets permit only a fixed shape to the advancing endotracheal tube. This may necessitate withdrawal of endotracheal tube-stylet assembly for reshaping, before undertaking a new attempt. This may cause soft tissue injury and hemodynamic disturbance.
- 16 September 2013
- Published by Springer Nature in Trials
- Vol. 14 (1) , 298
Open AccessAssessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices, the insertion and advancement of the endotracheal tube may be prolonged and occasionally fail as it does not conform to the enhanced angulation of the blade. To overcome this handicap, it is recommended to use a pre-shaped, styleted tracheal tube during intubation. Unfortunately, these malleable rigid stylets permit only a fixed shape to the advancing endotracheal tube. This may necessitate withdrawal of endotracheal tube-stylet assembly for reshaping, before undertaking a new attempt. This may cause soft tissue injury and hemodynamic disturbance.
- Open Access
- 12 February 2013
- Published by Springer Nature
Evaluation of Truflex™ Flexible Stylet as an intubation guide with the D-blade of C-Mac videolaryngoScope during elective tracheal intubation
- 12 February 2013
- Published by Springer Nature
Open AccessEvaluation of Truflex™ Flexible Stylet as an intubation guide with the D-blade of C-Mac videolaryngoScope during elective tracheal intubation
- 1 June 2012
- Vol. 21 (5) , 761-4
Acute tongue enlargement secondary to pharyngeal packing after tracheal intubation--a case report.
Acute tongue enlargement is a potentially lethal complication which is mostly reported in neurosurgical cases in sitting position. Very rarely it is reported in supine position. Most importantly it is reported at the end of the surgical procedures. Throat pack used along with tracheal intubation for protection of lower respiratory tract from soiling can lead to tongue enlargement due to obstruction of venous drainage. We are hereby reporting an interesting case of acute tongue enlargement in a patient scheduled for excision of brain tumor in supine position which occurred even before commencement of surgery due to excessive throat pack inserted for some nonessential indication. We thus recommend that throat pack should be used cautiously only when absolutely indicated. Otherwise it can lead to life threatening macroglossia.
- 1 June 2012
- Vol. 21 (5) , 761-4
Acute tongue enlargement secondary to pharyngeal packing after tracheal intubation--a case report.
Acute tongue enlargement is a potentially lethal complication which is mostly reported in neurosurgical cases in sitting position. Very rarely it is reported in supine position. Most importantly it is reported at the end of the surgical procedures. Throat pack used along with tracheal intubation for protection of lower respiratory tract from soiling can lead to tongue enlargement due to obstruction of venous drainage. We are hereby reporting an interesting case of acute tongue enlargement in a patient scheduled for excision of brain tumor in supine position which occurred even before commencement of surgery due to excessive throat pack inserted for some nonessential indication. We thus recommend that throat pack should be used cautiously only when absolutely indicated. Otherwise it can lead to life threatening macroglossia.
- 7 May 2012
- Published by Wiley in Anaesthesia
- Vol. 67 (6) , 677-678
Dynamic optimisation of the sniff position during laryngoscopy using a pressure infusion bag
- 7 May 2012
- Published by Wiley in Anaesthesia
- Vol. 67 (6) , 677-678
Dynamic optimisation of the sniff position during laryngoscopy using a pressure infusion bag