I. P. Lipscomb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
I. P. Lipscomb has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Charles William Keevil
School of Biological Sciences, University of Southampton, Southampton, UK
7 shared publications R. Collin
Environmental Healthcare Unit, School of Biological Sciences, University of Southampton, Bassett Crescent East, Southampton SO16 7PX, UK
4 shared publicationsA.K. Sihota
2 shared publicationsH. Pinchin
Environmental Healthcare Unit, School of Biological Sciences, University of Southampton, Bassett Crescent East, Southampton SO16 7PX, UK
2 shared publicationsH.E. Pinchin
2 shared publicationsK. Harris
Environmental Healthcare Unit, School of Biological Sciences, University of Southampton, Bassett Crescent East, Southampton SO16 7PX, UK
2 shared publications
Latest Publications
- 3 August 2008
- Published by Springer Nature in Journal of Electroceramics
- Vol. 23 (1) , 72-75
Micro-computer tomography—An aid in the investigation of structural changes in lead zirconate titanate ceramics after temperature-humidity bias testing
- 3 August 2008
- Published by Springer Nature in Journal of Electroceramics
- Vol. 23 (1) , 72-75
Micro-computer tomography—An aid in the investigation of structural changes in lead zirconate titanate ceramics after temperature-humidity bias testing
- 1 January 2008
- Published by Elsevier in Journal of Hospital Infection
- Vol. 68 (1) , 52-58
Comparison between visual analysis and microscope assessment of surgical instrument cleanliness from sterile service departments
- 1 January 2008
- Published by Elsevier in Journal of Hospital Infection
- Vol. 68 (1) , 52-58
Comparison between visual analysis and microscope assessment of surgical instrument cleanliness from sterile service departments
- Open Access
- 1 September 2007
- Published by Microbiology Society in Journal of General Virology
- Vol. 88 (9) , 2619-2626
Amyloid-specific fluorophores for the rapid, sensitive in situ detection of prion contamination on surgical instruments
Prion diseases or transmissible spongiform encephalopathies (TSEs) are a group of rare, transmissible and fatal neurodegenerative diseases associated with the protein agent (PrPSc). As such, the sensitive and rapid detection of prion PrPSc amyloid on the surface of suspect surgical instruments is of great importance and may even allow remedial action to be taken prior to any further operative intervention and possible iatrogenic transmission. However, conventional PrPSc detection methodologies tend to rely on the inefficient and unreliable removal of suspect material from a surface using swabs or wipes prior to antibody analysis. Here we show how the combination of an advanced light microscope technique, episcopic differential interference contrast/epifluorescence (EDIC/EF) microscopy, and the application of β-amyloid fluorescent thiazole markers (thioflavin T, thioflavin S) can be used to detect, in situ, submicron (attomole) levels of prion protein amyloid contamination in brain and spleen sections, smears and homogenate on surgical stainless steel surfaces and surgical instruments. This technique, although not specific to an amyloid type, can be used to verify that surgical instruments are substantially free from prion amyloid protein soiling and hence reduce the risk of iatrogenic transmission.
- 1 September 2007
- Published by Microbiology Society in Journal of General Virology
- Vol. 88 (9) , 2619-2626
Open AccessAmyloid-specific fluorophores for the rapid, sensitive in situ detection of prion contamination on surgical instruments
Prion diseases or transmissible spongiform encephalopathies (TSEs) are a group of rare, transmissible and fatal neurodegenerative diseases associated with the protein agent (PrPSc). As such, the sensitive and rapid detection of prion PrPSc amyloid on the surface of suspect surgical instruments is of great importance and may even allow remedial action to be taken prior to any further operative intervention and possible iatrogenic transmission. However, conventional PrPSc detection methodologies tend to rely on the inefficient and unreliable removal of suspect material from a surface using swabs or wipes prior to antibody analysis. Here we show how the combination of an advanced light microscope technique, episcopic differential interference contrast/epifluorescence (EDIC/EF) microscopy, and the application of β-amyloid fluorescent thiazole markers (thioflavin T, thioflavin S) can be used to detect, in situ, submicron (attomole) levels of prion protein amyloid contamination in brain and spleen sections, smears and homogenate on surgical stainless steel surfaces and surgical instruments. This technique, although not specific to an amyloid type, can be used to verify that surgical instruments are substantially free from prion amyloid protein soiling and hence reduce the risk of iatrogenic transmission.
- 1 January 2007
- Published by Elsevier in Journal of Hospital Infection
- Vol. 65 (1) , 72-77
Effect of drying time, ambient temperature and pre-soaks on prion-infected tissue contamination levels on surgical stainless steel: concerns over prolonged transportation of instruments from theatre to central sterile service departments
- 1 January 2007
- Published by Elsevier in Journal of Hospital Infection
- Vol. 65 (1) , 72-77
Effect of drying time, ambient temperature and pre-soaks on prion-infected tissue contamination levels on surgical stainless steel: concerns over prolonged transportation of instruments from theatre to central sterile service departments
- 1 November 2006
- Published by Elsevier in Journal of Hospital Infection
- Vol. 64 (3) , 288-292
The sensitivity of approved Ninhydrin and Biuret tests in the assessment of protein contamination on surgical steel as an aid to prevent iatrogenic prion transmission
- 1 November 2006
- Published by Elsevier in Journal of Hospital Infection
- Vol. 64 (3) , 288-292
The sensitivity of approved Ninhydrin and Biuret tests in the assessment of protein contamination on surgical steel as an aid to prevent iatrogenic prion transmission
- 1 October 2006
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 44 (10) , 3728-3733
Comparative Study of Surgical Instruments from Sterile-Service Departments for Presence of Residual Gram-Negative Endotoxin and Proteinaceous Deposits
The ineffective cleaning of surgical instruments may be a vector for the transmission of hospital-acquired infections. The aim of this research was to investigate whether further decontamination procedures need to be instigated in sterile-service departments (SSDs) to reduce the risk of nosocomial illnesses, such as endotoxemia, sepsis, or iatrogenic Creutzfeldt-Jakob disease (to date, 1,147 cases of confirmed Creutzfeldt-Jakob disease deaths in the United Kingdom since 1990 have been reported). Instrument sets were obtained from nine anonymous United Kingdom National Health Service (NHS) primary care trust SSDs. The investigation implemented an advanced light microscopy technique, episcopic differential interference contrast microscopy with the sensitive fluorescent reagents SYPRO Ruby and 4′,6-diamidino-2-phenylindole dihydrochloride (DAPI), to detect proteinaceous and microbial contamination levels. Gram-negative lipopolysaccharide (LPS) endotoxin was monitored using a dansylated polymyxin B fluorochrome agent. None of the 260 instruments examined displayed signs of microbial colonization or LPS endotoxin contamination. However, over 60 percent of the instruments showed a high degree of protein soiling (0.4 to 4.2 μg protein/mm 2 ). Some instruments appeared soiled with crystalline deposits that may consist of a potentially hazardous material contributing to inflammation and/or surgical shock. It is clear that the overall standard for cleaning must be raised in order to fulfill the imminent introduction of new European standards and to reduce the risk of cross-patient contamination and iatrogenic transmission.
- 1 October 2006
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 44 (10) , 3728-3733
Comparative Study of Surgical Instruments from Sterile-Service Departments for Presence of Residual Gram-Negative Endotoxin and Proteinaceous Deposits
The ineffective cleaning of surgical instruments may be a vector for the transmission of hospital-acquired infections. The aim of this research was to investigate whether further decontamination procedures need to be instigated in sterile-service departments (SSDs) to reduce the risk of nosocomial illnesses, such as endotoxemia, sepsis, or iatrogenic Creutzfeldt-Jakob disease (to date, 1,147 cases of confirmed Creutzfeldt-Jakob disease deaths in the United Kingdom since 1990 have been reported). Instrument sets were obtained from nine anonymous United Kingdom National Health Service (NHS) primary care trust SSDs. The investigation implemented an advanced light microscopy technique, episcopic differential interference contrast microscopy with the sensitive fluorescent reagents SYPRO Ruby and 4′,6-diamidino-2-phenylindole dihydrochloride (DAPI), to detect proteinaceous and microbial contamination levels. Gram-negative lipopolysaccharide (LPS) endotoxin was monitored using a dansylated polymyxin B fluorochrome agent. None of the 260 instruments examined displayed signs of microbial colonization or LPS endotoxin contamination. However, over 60 percent of the instruments showed a high degree of protein soiling (0.4 to 4.2 μg protein/mm 2 ). Some instruments appeared soiled with crystalline deposits that may consist of a potentially hazardous material contributing to inflammation and/or surgical shock. It is clear that the overall standard for cleaning must be raised in order to fulfill the imminent introduction of new European standards and to reduce the risk of cross-patient contamination and iatrogenic transmission.
- 1 February 2006
- Published by Elsevier in Journal of Hospital Infection
- Vol. 62 (2) , 141-148
Rapid method for the sensitive detection of protein contamination on surgical instruments
- 1 February 2006
- Published by Elsevier in Journal of Hospital Infection
- Vol. 62 (2) , 141-148
Rapid method for the sensitive detection of protein contamination on surgical instruments