Anthony Pease
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anthony Pease has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Al Segars
1 shared publicationAshley Behan
College of Veterinary Medicine Michigan State University East Lansing MI 48824
1 shared publicationBrandon Cain
Department of Small Animal Clinical Sciences, North Carolina State University, 4700 Hillsborough Street, Raleigh, NC
1 shared publicationDavid Owens
1 shared publicationDavid Rostal
1 shared publication- Derek M. Foster
Department of Population Health and Pathobiology, College of Veterinary Medicine, North Carolina State University, Raleigh, NC
1 shared publication
Latest Publications
- 1 December 2012
- Published by Elsevier in Veterinary Clinics of North America: Equine Practice
- Vol. 28 (3) , 637-646
Biochemical Evaluation of Equine Articular Cartilage Through Imaging
- 1 December 2012
- Published by Elsevier in Veterinary Clinics of North America: Equine Practice
- Vol. 28 (3) , 637-646
Biochemical Evaluation of Equine Articular Cartilage Through Imaging
- 10 August 2011
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 53 (1) , 92-95
ULTRASOUND‐GUIDED CERVICAL CENTESIS TO OBTAIN CEREBROSPINAL FLUID IN THE STANDING HORSE
Horses with intracranial lesions and severe ataxia are not good anesthesia candidates; however, only one method to obtain cerebrospinal fluid (CSF) from the cervical region in a standing horse has been reported. This method is not performed routinely due to the difficulty for sample acquisition. Our hypothesis is that standing cervical centesis can be performed in horses without complication. Ultrasound-guided centesis of the CSF between C1 and C2 in 11 clinically normal horses and two horses with neurologic signs were performed. Horses were sedated and ultrasound was used to identify the subarachnoid space and spinal cord between C1 and C2. With ultrasound guidance, a needle was introduced into the dorsal aspect of the subarachnoid space using a lateral approach. Ten milliliters of CSF was obtained and analyzed. Two normal horses in this study had moderate red blood cell contamination in the CSF (940 and 612 RBC/μl). One horse had 11 RBC/μl and the remaining horses had <4 RBC/μl. The total procedure time was approximately 2 min. No reaction was observed and no complications were detected up to 48 h after the procedure. Ultrasound-guided centesis between C1 and C2 is a rapid procedure that causes minimal to no reaction in standing, sedated horses used in this study. The use of ultrasound to guide a standing C1–2 centesis of the subarachnoid space provides an additional route to obtain CSF for analysis in the equine patient.
- 10 August 2011
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 53 (1) , 92-95
ULTRASOUND‐GUIDED CERVICAL CENTESIS TO OBTAIN CEREBROSPINAL FLUID IN THE STANDING HORSE
Horses with intracranial lesions and severe ataxia are not good anesthesia candidates; however, only one method to obtain cerebrospinal fluid (CSF) from the cervical region in a standing horse has been reported. This method is not performed routinely due to the difficulty for sample acquisition. Our hypothesis is that standing cervical centesis can be performed in horses without complication. Ultrasound-guided centesis of the CSF between C1 and C2 in 11 clinically normal horses and two horses with neurologic signs were performed. Horses were sedated and ultrasound was used to identify the subarachnoid space and spinal cord between C1 and C2. With ultrasound guidance, a needle was introduced into the dorsal aspect of the subarachnoid space using a lateral approach. Ten milliliters of CSF was obtained and analyzed. Two normal horses in this study had moderate red blood cell contamination in the CSF (940 and 612 RBC/μl). One horse had 11 RBC/μl and the remaining horses had <4 RBC/μl. The total procedure time was approximately 2 min. No reaction was observed and no complications were detected up to 48 h after the procedure. Ultrasound-guided centesis between C1 and C2 is a rapid procedure that causes minimal to no reaction in standing, sedated horses used in this study. The use of ultrasound to guide a standing C1–2 centesis of the subarachnoid space provides an additional route to obtain CSF for analysis in the equine patient.
- 20 June 2011
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 52 (5) , 492-497
THE USE OF DIFFUSION TENSOR IMAGING TO EVALUATE THE SPINAL CORD IN NORMAL AND ABNORMAL DOGS
Diffusion tensor imaging (DTI) is a specialized magnetic resonance sequence to determine the direction of water molecule motion. Our hypothesis was that information derived from DTI will be significantly different in dogs with a spinal cord lesion compared with a normal dog. Eleven normal dogs and six dogs with a spinal cord lesions were imaged. DTI was performed along with standard T1- and T2-weighted sequences in transverse and sagittal planes. Fractional anisotrophy and apparent diffusion coefficient (ADC) were obtained using regions of interests centered on the cranial aspect, middle cranial, middle caudal, and caudal aspects of the spinal cord. In normal dogs, the DTI sequence was characterized by normal fiber tracking with no statistical difference between the four sections of spinal cord (P>0.05). In the dogs with a spinal cord lesion, there was a significant difference in fractional anisotropy between the two groups (P=0.0003) and the ADC analysis statistical significance (P=0.048) at the caudal most site. Based on these findings, DTI is a potentially useful method to evaluate the spinal cord in dogs.
- 20 June 2011
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 52 (5) , 492-497
THE USE OF DIFFUSION TENSOR IMAGING TO EVALUATE THE SPINAL CORD IN NORMAL AND ABNORMAL DOGS
Diffusion tensor imaging (DTI) is a specialized magnetic resonance sequence to determine the direction of water molecule motion. Our hypothesis was that information derived from DTI will be significantly different in dogs with a spinal cord lesion compared with a normal dog. Eleven normal dogs and six dogs with a spinal cord lesions were imaged. DTI was performed along with standard T1- and T2-weighted sequences in transverse and sagittal planes. Fractional anisotrophy and apparent diffusion coefficient (ADC) were obtained using regions of interests centered on the cranial aspect, middle cranial, middle caudal, and caudal aspects of the spinal cord. In normal dogs, the DTI sequence was characterized by normal fiber tracking with no statistical difference between the four sections of spinal cord (P>0.05). In the dogs with a spinal cord lesion, there was a significant difference in fractional anisotropy between the two groups (P=0.0003) and the ADC analysis statistical significance (P=0.048) at the caudal most site. Based on these findings, DTI is a potentially useful method to evaluate the spinal cord in dogs.
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Necrotizing Enterocolitis of Preterm Piglets is Characterized by a Unique Ileum Mucosa-Associated Microbiome
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Necrotizing Enterocolitis of Preterm Piglets is Characterized by a Unique Ileum Mucosa-Associated Microbiome
- 9 November 2010
- Published by Wiley in Equine Veterinary Education
- Vol. 22 (12) , 608-609
Lipoma and infiltrative lipoma: A diagnostic dilemma
- 9 November 2010
- Published by Wiley in Equine Veterinary Education
- Vol. 22 (12) , 608-609
Lipoma and infiltrative lipoma: A diagnostic dilemma
- 22 March 2010
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 51 (4) , 447-452
ULTRASONOGRAPHY OF HISTOLOGICALLY NORMAL PARATHYROID GLANDS AND THYROID LOBULES IN NORMOCALCEMIC DOGS
The purpose of this study is to characterize the sonographic appearance of canine parathyroid glands using high‐resolution ultrasonography. Ten cadaver dogs were studied after euthanasia for reasons not relating to the parathyroid. The cervical region was examined using a 13–5 MHz linear transducer in right and left recumbency. Ultrasonographic features of the parathyroid and thyroid glands were compared with the gross and histopathologic findings. Thirty‐five structures were identified sonographically as parathyroid glands but only 26 of 35 glands (74% positive predictive value) were proven to be normal parathyroid glands histopathologically. Of the nine false positives, five (14%) were proven to be lobular thyroid tissue. The remaining four (11%) structures were visible grossly or found histopathologically. There were no statistical differences between ultrasonographic and gross measurements of the parathyroid glands. The average size as seen sonographically was 3.3 × 2.2 × 1.7 mm and the average gross size was 3.7 × 2.6 × 1.6 mm (length, width, height). The average size of the thyroid lobules assessed sonographically was 2.3 × 1.6 × 0.8 mm (length, width, height). Normal parathyroid glands can be identified using high‐resolution ultrasonography. But some thyroid lobules will be misinterpreted as parathyroid glands; this will result in false positives when identifying parathyroid glands with ultrasonography.
- 22 March 2010
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 51 (4) , 447-452
ULTRASONOGRAPHY OF HISTOLOGICALLY NORMAL PARATHYROID GLANDS AND THYROID LOBULES IN NORMOCALCEMIC DOGS
The purpose of this study is to characterize the sonographic appearance of canine parathyroid glands using high‐resolution ultrasonography. Ten cadaver dogs were studied after euthanasia for reasons not relating to the parathyroid. The cervical region was examined using a 13–5 MHz linear transducer in right and left recumbency. Ultrasonographic features of the parathyroid and thyroid glands were compared with the gross and histopathologic findings. Thirty‐five structures were identified sonographically as parathyroid glands but only 26 of 35 glands (74% positive predictive value) were proven to be normal parathyroid glands histopathologically. Of the nine false positives, five (14%) were proven to be lobular thyroid tissue. The remaining four (11%) structures were visible grossly or found histopathologically. There were no statistical differences between ultrasonographic and gross measurements of the parathyroid glands. The average size as seen sonographically was 3.3 × 2.2 × 1.7 mm and the average gross size was 3.7 × 2.6 × 1.6 mm (length, width, height). The average size of the thyroid lobules assessed sonographically was 2.3 × 1.6 × 0.8 mm (length, width, height). Normal parathyroid glands can be identified using high‐resolution ultrasonography. But some thyroid lobules will be misinterpreted as parathyroid glands; this will result in false positives when identifying parathyroid glands with ultrasonography.
- 1 January 2010
- Published by American Association of Zoo Veterinarians in Journal of Zoo and Wildlife Medicine
- Vol. 41 (1) , 69-76
Ultrasound Imaging of the Inguinal Region of Adult Male Loggerhead Sea Turtles (Caretta caretta)
The biology and reproductive anatomy of male loggerhead sea turtles (Caretta caretta) have been difficult to study. The principle method for evaluation of the coelomic cavity in both adult and juvenile male sea turtles is celioscopy. The purpose of this study was to describe the technique and structures seen when scanning the inguinal region of live, wild-caught, adult male loggerhead sea turtles and to compare these findings to those resulting from celioscopy and necropsy. Twenty-one adult male loggerhead sea turtles were collected by trawling in the Cape Canaveral shipping channel in April 2007. All turtles were placed in dorsal recumbency and imaged with a Sonosite 180 Vet Plus (Sonosite, Inc., Bothell, Washington 98021, USA) and a microconvex, 4-7-MHz curvilinear array probe. The inguinal region was divided into four quadrants: cranial, lateral, medial, and caudal. Celioscopy was performed on 13 turtles, and biopsies were obtained of the testes and the epididymides to confirm correct identification of the structures. In the cranial aspect of the inguinal region, the urinary bladder and large and small intestines were identified. In the lateral inguinal region, the lung and kidney were seen. In the medial aspect of the inguinal region, the testis and epididymis were routinely identified. In the caudal aspect of the inguinal region, the coxofemoral joint was seen. A small learning curve was required; however, correlation with celioscopy and biopsy showed that consistent, repeatable identification of caudal coelomic structures was easily achieved. Ultrasound provided an inexpensive, rapid, noninvasive method to evaluate the reproductive anatomy of live-captured, male loggerhead sea turtles.
- 1 January 2010
- Published by American Association of Zoo Veterinarians in Journal of Zoo and Wildlife Medicine
- Vol. 41 (1) , 69-76
Ultrasound Imaging of the Inguinal Region of Adult Male Loggerhead Sea Turtles (Caretta caretta)
The biology and reproductive anatomy of male loggerhead sea turtles (Caretta caretta) have been difficult to study. The principle method for evaluation of the coelomic cavity in both adult and juvenile male sea turtles is celioscopy. The purpose of this study was to describe the technique and structures seen when scanning the inguinal region of live, wild-caught, adult male loggerhead sea turtles and to compare these findings to those resulting from celioscopy and necropsy. Twenty-one adult male loggerhead sea turtles were collected by trawling in the Cape Canaveral shipping channel in April 2007. All turtles were placed in dorsal recumbency and imaged with a Sonosite 180 Vet Plus (Sonosite, Inc., Bothell, Washington 98021, USA) and a microconvex, 4-7-MHz curvilinear array probe. The inguinal region was divided into four quadrants: cranial, lateral, medial, and caudal. Celioscopy was performed on 13 turtles, and biopsies were obtained of the testes and the epididymides to confirm correct identification of the structures. In the cranial aspect of the inguinal region, the urinary bladder and large and small intestines were identified. In the lateral inguinal region, the lung and kidney were seen. In the medial aspect of the inguinal region, the testis and epididymis were routinely identified. In the caudal aspect of the inguinal region, the coxofemoral joint was seen. A small learning curve was required; however, correlation with celioscopy and biopsy showed that consistent, repeatable identification of caudal coelomic structures was easily achieved. Ultrasound provided an inexpensive, rapid, noninvasive method to evaluate the reproductive anatomy of live-captured, male loggerhead sea turtles.