Tatsuo Nakamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tatsuo Nakamura has a total of 176 co-authors. Here are the top co-authors by number of shared publications:
Yasuhiko Shimizu
15 shared publications- Koichi Omori
Department of Otolaryngology, Fukushima Medical University
7 shared publications Akira Nakada
Department of Bioartificial Organs, Institute for Frontier Medical Sciences, Kyoto University, Kyoto, Japan
6 shared publications- Hiroshi Date
Department of Thoracic Surgery, Kyoto University Hospital, Kyoto, Japan
5 shared publications Keiji Shigeno
Laboratory of Organ and Tissue Reconstruction, Department of Regeneration Science and Engineering, Institute for Frontier Life and Medical Sciences, Kyoto University, Shogoin Kawahara-cho 53, Kyoto, 606-8507, Japan
4 shared publicationsTeruya Komatsu
4 shared publications
Latest Publications
- 1 April 2018
- Published by AME Publishing Company in ASVIDE
- Vol. 5 (1) , 429
The 3D-printed socket could not tolerate the bending test, resulting in snapping before being completely straightened (point of failure)
The 3D-printed socket could not tolerate the bending test, resulting in snapping before being completely straightened (point of failure)
- 1 April 2018
- Published by AME Publishing Company in ASVIDE
- Vol. 5 (1) , 429
The 3D-printed socket could not tolerate the bending test, resulting in snapping before being completely straightened (point of failure)
The 3D-printed socket could not tolerate the bending test, resulting in snapping before being completely straightened (point of failure)
- 1 April 2018
- Published by AME Publishing Company in ASVIDE
- Vol. 5, 430
The PLA fiber socket showed ductile characteristics, restoring to its original curvature radius
- 1 April 2018
- Published by AME Publishing Company in ASVIDE
- Vol. 5, 430
The PLA fiber socket showed ductile characteristics, restoring to its original curvature radius
- 1 April 2018
- Published by AME Publishing Company in ASVIDE
- Vol. 5, 431
Operative video of socket implantation
- 1 April 2018
- Published by AME Publishing Company in ASVIDE
- Vol. 5, 431
Operative video of socket implantation
- 1 March 2018
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 21 (1) , 17-22
Artificial sensory organs: latest progress
This study introduces the latest progress on the study of artificial sensory organs, with a special emphasis on the clinical results of artificial nerves and the concept of in situ tissue engineering. Peripheral nerves have a strong potential for regeneration. An artificial nerve uses this potential to recover a damaged peripheral nerve. The polyglycolic acid collagen tube (PGA-C tube) is a bio-absorbable tube stuffed with collagen of multi-chamber structure that consists of thin collagen films. The clinical application of the PGA-C tube began in 2002 in Japan. The number of PGA-C tubes used is now beyond 300, and satisfactory results have been reported on peripheral nerve repairs. This PGA-C tube is also effective for patients suffering from neuropathic pain.
- 1 March 2018
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 21 (1) , 17-22
Artificial sensory organs: latest progress
This study introduces the latest progress on the study of artificial sensory organs, with a special emphasis on the clinical results of artificial nerves and the concept of in situ tissue engineering. Peripheral nerves have a strong potential for regeneration. An artificial nerve uses this potential to recover a damaged peripheral nerve. The polyglycolic acid collagen tube (PGA-C tube) is a bio-absorbable tube stuffed with collagen of multi-chamber structure that consists of thin collagen films. The clinical application of the PGA-C tube began in 2002 in Japan. The number of PGA-C tubes used is now beyond 300, and satisfactory results have been reported on peripheral nerve repairs. This PGA-C tube is also effective for patients suffering from neuropathic pain.
- 8 March 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (10) , 4260-4267
Development of a novel lung-stabilizing device for VATS procedures
Background The use of video-assisted thoracoscopic surgery (VATS) has substantially increased in recent years. These procedures involve the insertion of specialized devices into the thoracic cavity via access ports. However, conventional devices such as cotton-tipped applicators and graspers can limit the field of view and injure the fragile lung tissue. The aim of this study was to develop a novel lung-stabilizing device for VATS that provides a good surgical field of view without causing lung injury. Methods We developed a novel suction-based lung-stabilizing device equipped with three hemispheric 20-mm-diameter silicon suction cups. The utility and safety of the novel device were evaluated using a resected pig lung and canine models. In order to assess potential organ damage arising from the use of the novel device, canine lung parenchyma and pleura were macroscopically and microscopically examined after the device had been continuously applied under negative pressure conditions of −400 or −540 mmHg for 1 h. Results To assess the utility of the novel device, we performed lobectomies in the resected pig lung and VATS in canine models. The device demonstrated sufficient power to stabilize the lungs and provided a clear field of view during surgery, which enabled us to perform VATS lobectomies more easily than conventional stabilizing forceps. Assessment of the dogs’ lungs immediately after detaching the suction-based device revealed no complications such as hemorrhage, air leaks, and bullae formation. Pathological examination after 7 days also showed no substantial damage, except for a small impression in the parenchyma and pleura of the surface layer where the device had contacted the lung tissue. Conclusions Although further validation studies in clinical settings are required, our study indicates that the novel lung-stabilizing device has potentially useful applications in VATS procedures.
- 8 March 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (10) , 4260-4267
Development of a novel lung-stabilizing device for VATS procedures
Background The use of video-assisted thoracoscopic surgery (VATS) has substantially increased in recent years. These procedures involve the insertion of specialized devices into the thoracic cavity via access ports. However, conventional devices such as cotton-tipped applicators and graspers can limit the field of view and injure the fragile lung tissue. The aim of this study was to develop a novel lung-stabilizing device for VATS that provides a good surgical field of view without causing lung injury. Methods We developed a novel suction-based lung-stabilizing device equipped with three hemispheric 20-mm-diameter silicon suction cups. The utility and safety of the novel device were evaluated using a resected pig lung and canine models. In order to assess potential organ damage arising from the use of the novel device, canine lung parenchyma and pleura were macroscopically and microscopically examined after the device had been continuously applied under negative pressure conditions of −400 or −540 mmHg for 1 h. Results To assess the utility of the novel device, we performed lobectomies in the resected pig lung and VATS in canine models. The device demonstrated sufficient power to stabilize the lungs and provided a clear field of view during surgery, which enabled us to perform VATS lobectomies more easily than conventional stabilizing forceps. Assessment of the dogs’ lungs immediately after detaching the suction-based device revealed no complications such as hemorrhage, air leaks, and bullae formation. Pathological examination after 7 days also showed no substantial damage, except for a small impression in the parenchyma and pleura of the surface layer where the device had contacted the lung tissue. Conclusions Although further validation studies in clinical settings are required, our study indicates that the novel lung-stabilizing device has potentially useful applications in VATS procedures.
- 1 February 2017
- Published by Elsevier in Auris Nasus Larynx
- Vol. 44 (1) , 86-92
Drug delivery system of basic fibroblast growth factor using gelatin hydrogel for restoration of acute vocal fold scar
- 1 February 2017
- Published by Elsevier in Auris Nasus Larynx
- Vol. 44 (1) , 86-92
Drug delivery system of basic fibroblast growth factor using gelatin hydrogel for restoration of acute vocal fold scar
- 1 January 2017
- Published by Japan Society for Head and Neck Cancer in Toukeibu Gan
- Vol. 43 (3) , 367-371
Tracheal regeneration using an artificial trachea: a multicenter clinical trial
気管は生命維持に不可欠な臓器であるが,時として悪性腫瘍の浸潤,外傷,炎症などによる狭窄のため切除を余儀なくされる。切除により生じる気管欠損は整容的にも,機能的にもハンディキャップとなるが,大きな欠損の再建には難渋することも多い。われわれはin situ tissue engineeringのコンセプトに基づき,コラーゲンの足場をポリプロピレンで補強した生体内組織再生誘導型人工気管を開発した。これまでに,この人工気管を用いた非臨床試験および臨床研究を行い良好な成績が確認されている。現在われわれは,この人工気管の医療機器としての薬機承認および保険収載を目標とし,有効性,安全性を確認するための多施設共同医師主導治験を行っている。対象は既存治療で気管切開孔を閉鎖できない患者と悪性腫瘍切除に伴い気管軟骨の1/2周以上かつ3輪以上の欠損が生じることが予想される患者である。この治験を完遂し,有効性・安全性が確認されれば薬機承認申請を行う予定である。
- 1 January 2017
- Published by Japan Society for Head and Neck Cancer in Toukeibu Gan
- Vol. 43 (3) , 367-371
Tracheal regeneration using an artificial trachea: a multicenter clinical trial
気管は生命維持に不可欠な臓器であるが,時として悪性腫瘍の浸潤,外傷,炎症などによる狭窄のため切除を余儀なくされる。切除により生じる気管欠損は整容的にも,機能的にもハンディキャップとなるが,大きな欠損の再建には難渋することも多い。われわれはin situ tissue engineeringのコンセプトに基づき,コラーゲンの足場をポリプロピレンで補強した生体内組織再生誘導型人工気管を開発した。これまでに,この人工気管を用いた非臨床試験および臨床研究を行い良好な成績が確認されている。現在われわれは,この人工気管の医療機器としての薬機承認および保険収載を目標とし,有効性,安全性を確認するための多施設共同医師主導治験を行っている。対象は既存治療で気管切開孔を閉鎖できない患者と悪性腫瘍切除に伴い気管軟骨の1/2周以上かつ3輪以上の欠損が生じることが予想される患者である。この治験を完遂し,有効性・安全性が確認されれば薬機承認申請を行う予定である。
- 12 October 2016
- Published by Hindawi Limited in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 10 (10)
Cover Image, Volume 10, Issue 10
The cover image, by Morimasa Kitamura et al., is based on the Research Article Glottic regeneration with a tissue-engineering technique, using acellular extracellular matrix scaffold in a canine model†, DOI: 10.1002/term.1855.
- 12 October 2016
- Published by Hindawi Limited in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 10 (10)
Cover Image, Volume 10, Issue 10
The cover image, by Morimasa Kitamura et al., is based on the Research Article Glottic regeneration with a tissue-engineering technique, using acellular extracellular matrix scaffold in a canine model†, DOI: 10.1002/term.1855.
- 3 August 2016
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (8) , 2301-2307
Optimal dehydrothermal processing conditions to improve biocompatibility and durability of a weakly denatured collagen scaffold
Collagen scaffolds are essential for tissue regeneration; however, preprocessing of these scaffolds is necessary because of their poor mechanical properties. The aim of this study was to determine the optimal condition for preparing a collagen scaffold with biocompatibility and durability. An atelocollagen fiber suspension was made and stored at −10°C in a container that could be cooled from the bottom to provide an orientation perpendicular to the collagen fiber and facilitate cell infiltration into the scaffold. After freeze‐drying the frozen suspension, various collagen scaffolds were made by dehydrothermal (DHT) treatment under different conditions (processing temperature: 120–160°C for 0–28 h). Sections of the obtained materials were embedded under the back skin of rats, and the thickness and biocompatibility of the residual scaffold were evaluated after 2 weeks. The number of foreign body giant cells was counted to evaluate biocompatibility. Although the residual scaffold was thick, excessive DHT treatment caused a strong foreign body reaction. Weak DHT treatment resulted in a collagen scaffold with good biocompatibility but with reduced thickness. Overall, these results showed the restricted optimal conditions to make a collagen scaffold with good biocompatibility and ability to maintain sufficient space for tissue regeneration. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2301–2307, 2017.
- 3 August 2016
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (8) , 2301-2307
Optimal dehydrothermal processing conditions to improve biocompatibility and durability of a weakly denatured collagen scaffold
Collagen scaffolds are essential for tissue regeneration; however, preprocessing of these scaffolds is necessary because of their poor mechanical properties. The aim of this study was to determine the optimal condition for preparing a collagen scaffold with biocompatibility and durability. An atelocollagen fiber suspension was made and stored at −10°C in a container that could be cooled from the bottom to provide an orientation perpendicular to the collagen fiber and facilitate cell infiltration into the scaffold. After freeze‐drying the frozen suspension, various collagen scaffolds were made by dehydrothermal (DHT) treatment under different conditions (processing temperature: 120–160°C for 0–28 h). Sections of the obtained materials were embedded under the back skin of rats, and the thickness and biocompatibility of the residual scaffold were evaluated after 2 weeks. The number of foreign body giant cells was counted to evaluate biocompatibility. Although the residual scaffold was thick, excessive DHT treatment caused a strong foreign body reaction. Weak DHT treatment resulted in a collagen scaffold with good biocompatibility but with reduced thickness. Overall, these results showed the restricted optimal conditions to make a collagen scaffold with good biocompatibility and ability to maintain sufficient space for tissue regeneration. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2301–2307, 2017.
- Open Access
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 1A2-01b2
Made-to-order Handy Interface with Adjustable Switch Position for Finger Length
A handy switch interface has been developed to allow a surgeon in a sterilized area to control a locally operated forceps manipulator (LODEM) with five-DOFs. The proposed made-to-order interface with adjustable switch position is designed based on the finger length of human hand. The ergonomic interface consists of an analog pad switch for a forefinger, and two small push switches for a middle finger and a ring finger respectively. Two large or small sizes of prototypes based on the measurement of finger length were made by a 3D printer. The control time was evaluated while performing a task model using prototypes by two groups with large or small hand sizes. The difference between task times was not shown, but tiredness under control was indicated by all subjects. An ergonomic handy interface was designed that allows minimally invasive robotically assisted endoscopic surgery.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 1A2-01b2
Open AccessMade-to-order Handy Interface with Adjustable Switch Position for Finger Length
A handy switch interface has been developed to allow a surgeon in a sterilized area to control a locally operated forceps manipulator (LODEM) with five-DOFs. The proposed made-to-order interface with adjustable switch position is designed based on the finger length of human hand. The ergonomic interface consists of an analog pad switch for a forefinger, and two small push switches for a middle finger and a ring finger respectively. Two large or small sizes of prototypes based on the measurement of finger length were made by a 3D printer. The control time was evaluated while performing a task model using prototypes by two groups with large or small hand sizes. The difference between task times was not shown, but tiredness under control was indicated by all subjects. An ergonomic handy interface was designed that allows minimally invasive robotically assisted endoscopic surgery.