Saeed Mirsadraee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Saeed Mirsadraee has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
- David Ernest Newby
University of Edinburgh
7 shared publications - Marc Richard Dweck
University of Edinburgh
5 shared publications - Edwin J. R. van Beek
Edinburgh Imaging, Queen’s Medical Research Institute, University of Edinburgh, Edinburgh, UK
4 shared publications - Michelle Claire Williams
University of Edinburgh, Edinburgh, UK
4 shared publications - Scott Semple
Engineer- ing The University of Edinburgh EH9 3JL Edinburgh UK. S
4 shared publications - Peter A. Henriksen
BHF Centre for Cardiovascular Science, University of Edinburgh, UK
3 shared publications
Latest Publications
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 2 (3) , 259-271
Multimodality Quantitative Assessments of Myocardial Perfusion Using Dynamic Contrast Enhanced Magnetic Resonance and 15O-Labeled Water Positron Emission Tomography Imaging
Kinetic modeling of myocardial perfusion imaging data allows the absolute quantification of myocardial blood flow (MBF) and can improve the diagnosis and clinical assessment of coronary artery disease (CAD). Positron emission tomography (PET) imaging is considered the reference standard technique for absolute quantification, whilst oxygen-15 (15O)-water has been extensively implemented for MBF quantification. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has also been used for MBF quantification and showed comparable diagnostic performance against (15O)-water PET studies. We investigated for the first time the diagnostic performance of two different PET MBF analysis softwares PMOD and Carimas, for obstructive CAD detection against invasive clinical standard methods in 20 patients with known or suspected CAD. Fermi and distributed parameter modeling-derived MBF quantification from DCE-MRI was also compared against (15O)-water PET, in a subgroup of six patients. The sensitivity and specificity for PMOD was significantly superior for obstructive CAD detection in both per vessel (0.83, 0.90) and per patient (0.86, 0.75) analysis, against Carimas (0.75, 0.65) and (0.81, 0.70), respectively. We showed strong, significant correlations between MR and PET MBF quantifications (r = 0.83 - 0.92). However, DP and PMOD analysis demonstrated comparable and higher hemodynamic differences between obstructive versus (no, minor, or non)-obstructive CAD, against Fermi and Carimas analysis. Our MR method assessments against the optimum PET reference standard technique for perfusion analysis showed promising results in per segment level and can support further multimodality assessments in larger patient cohorts. Further MR against PET assessments may help to determine their comparative diagnostic performance for obstructive CAD detection.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 2 (3) , 259-271
Multimodality Quantitative Assessments of Myocardial Perfusion Using Dynamic Contrast Enhanced Magnetic Resonance and 15O-Labeled Water Positron Emission Tomography Imaging
Kinetic modeling of myocardial perfusion imaging data allows the absolute quantification of myocardial blood flow (MBF) and can improve the diagnosis and clinical assessment of coronary artery disease (CAD). Positron emission tomography (PET) imaging is considered the reference standard technique for absolute quantification, whilst oxygen-15 (15O)-water has been extensively implemented for MBF quantification. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has also been used for MBF quantification and showed comparable diagnostic performance against (15O)-water PET studies. We investigated for the first time the diagnostic performance of two different PET MBF analysis softwares PMOD and Carimas, for obstructive CAD detection against invasive clinical standard methods in 20 patients with known or suspected CAD. Fermi and distributed parameter modeling-derived MBF quantification from DCE-MRI was also compared against (15O)-water PET, in a subgroup of six patients. The sensitivity and specificity for PMOD was significantly superior for obstructive CAD detection in both per vessel (0.83, 0.90) and per patient (0.86, 0.75) analysis, against Carimas (0.75, 0.65) and (0.81, 0.70), respectively. We showed strong, significant correlations between MR and PET MBF quantifications (r = 0.83 - 0.92). However, DP and PMOD analysis demonstrated comparable and higher hemodynamic differences between obstructive versus (no, minor, or non)-obstructive CAD, against Fermi and Carimas analysis. Our MR method assessments against the optimum PET reference standard technique for perfusion analysis showed promising results in per segment level and can support further multimodality assessments in larger patient cohorts. Further MR against PET assessments may help to determine their comparative diagnostic performance for obstructive CAD detection.
- Open Access
- 1 January 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 98, 143-149
Validation of an imaging based cardiovascular risk score in a Scottish population
- 1 January 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 98, 143-149
Open AccessValidation of an imaging based cardiovascular risk score in a Scottish population
- Open Access
- 16 December 2017
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 12 (1) , 115
Myocardial inflammation, injury and infarction during on-pump coronary artery bypass graft surgery
Myocardial inflammation and injury occur during coronary artery bypass graft (CABG) surgery. We aimed to characterise these processes during routine CABG surgery to inform the diagnosis of type 5 myocardial infarction. We assessed 87 patients with stable coronary artery disease who underwent elective CABG surgery. Myocardial inflammation, injury and infarction were assessed using plasma inflammatory biomarkers, high-sensitivity cardiac troponin I (hs-cTnI) and cardiac magnetic resonance imaging (CMR) using both late gadolinium enhancement (LGE) and ultrasmall superparamagnetic particles of iron oxide (USPIO). Systemic humoral inflammatory biomarkers (myeloperoxidase, interleukin-6, interleukin-8 and c-reactive protein) increased in the post-operative period with C-reactive protein concentrations plateauing by 48 h (median area under the curve (AUC) 7530 [interquartile range (IQR) 6088 to 9027] mg/L/48 h). USPIO-defined cellular myocardial inflammation ranged from normal to those associated with type 1 myocardial infarction (median 80.2 [IQR 67.4 to 104.8] /s). Plasma hs-cTnI concentrations rose by ≥50-fold from baseline and exceeded 10-fold the upper limit of normal in all patients. Two distinct patterns of peak cTnI release were observed at 6 and 24 h. After CABG surgery, new LGE was seen in 20% (n = 18) of patients although clinical peri-operative type 5 myocardial infarction was diagnosed in only 9% (n = 8). LGE was associated with the delayed 24-h peak in hs-cTnI and its magnitude correlated with AUC plasma hs-cTnI concentrations (r = 0.33, p < 0.01) but not systemic inflammation, myocardial inflammation or bypass time. Patients undergoing CABG surgery invariably have plasma hs-cTnI concentrations >10-fold the 99th centile upper limit of normal that is not attributable to inflammatory or ischemic injury alone. Peri-operative type 5 myocardial infarction is often unrecognised and is associated with a delayed 24-h peak in plasma hs-cTnI concentrations.
- 16 December 2017
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 12 (1) , 115
Open AccessMyocardial inflammation, injury and infarction during on-pump coronary artery bypass graft surgery
Myocardial inflammation and injury occur during coronary artery bypass graft (CABG) surgery. We aimed to characterise these processes during routine CABG surgery to inform the diagnosis of type 5 myocardial infarction. We assessed 87 patients with stable coronary artery disease who underwent elective CABG surgery. Myocardial inflammation, injury and infarction were assessed using plasma inflammatory biomarkers, high-sensitivity cardiac troponin I (hs-cTnI) and cardiac magnetic resonance imaging (CMR) using both late gadolinium enhancement (LGE) and ultrasmall superparamagnetic particles of iron oxide (USPIO). Systemic humoral inflammatory biomarkers (myeloperoxidase, interleukin-6, interleukin-8 and c-reactive protein) increased in the post-operative period with C-reactive protein concentrations plateauing by 48 h (median area under the curve (AUC) 7530 [interquartile range (IQR) 6088 to 9027] mg/L/48 h). USPIO-defined cellular myocardial inflammation ranged from normal to those associated with type 1 myocardial infarction (median 80.2 [IQR 67.4 to 104.8] /s). Plasma hs-cTnI concentrations rose by ≥50-fold from baseline and exceeded 10-fold the upper limit of normal in all patients. Two distinct patterns of peak cTnI release were observed at 6 and 24 h. After CABG surgery, new LGE was seen in 20% (n = 18) of patients although clinical peri-operative type 5 myocardial infarction was diagnosed in only 9% (n = 8). LGE was associated with the delayed 24-h peak in hs-cTnI and its magnitude correlated with AUC plasma hs-cTnI concentrations (r = 0.33, p < 0.01) but not systemic inflammation, myocardial inflammation or bypass time. Patients undergoing CABG surgery invariably have plasma hs-cTnI concentrations >10-fold the 99th centile upper limit of normal that is not attributable to inflammatory or ischemic injury alone. Peri-operative type 5 myocardial infarction is often unrecognised and is associated with a delayed 24-h peak in plasma hs-cTnI concentrations.
- Open Access
012 Longitudinal cardiac magnetic resonance assessment of diffuse and replacement myocardial fibrosis in aortic stenosis
Objective To investigate whether cardiac magnetic resonance (CMR) can assess the progression and regression of myocardial fibrosis in patients with aortic stenosis (AS). Methods Sixty-three patients with aortic stenosis were followed up for 2 years with serial CMR and echocardiography: 28 patients (63±13 years, 68% male, 50% asymptomatic severe AS) did not undergo intervention (natural history cohort) and 35 patients (67±8 years, 73% male, 83% symptomatic severe AS) underwent aortic valve replacement (AVR) within the first year (AVR cohort). Replacement and diffuse myocardial fibrosis were assessed using the late gadolinium enhancement (LGE) and T1 mapping techniques respectively. Annualised change was calculated for all measures. Results In the natural history cohort, left ventricular mass index (LVMi) increased over time (6%±1%, pConclusion Changes in diffuse fibrosis can be tracked using iECV and increase with time in patients with AS alongside LV mass and replacement fibrosis. Following AVR there is a fall in LV mass driven predominantly by regression of cellular hypertrophy with more gradual reduction in diffuse fibrosis burden but no change in replacement fibrosis. Mid-wall LGE is present on baseline scan (white arrow) and new areas are seen on 1 year scan (red arrows). Following AVR there is no change in mid-wall LGE (white arrows). Annualised change in imaging measures is presented below in the natural history (black) and AVR (red) groups. Main Figure: Serial cardiac magnetic resonance imaging in a patient with severe aortic stenosis.
Open Access012 Longitudinal cardiac magnetic resonance assessment of diffuse and replacement myocardial fibrosis in aortic stenosis
Objective To investigate whether cardiac magnetic resonance (CMR) can assess the progression and regression of myocardial fibrosis in patients with aortic stenosis (AS). Methods Sixty-three patients with aortic stenosis were followed up for 2 years with serial CMR and echocardiography: 28 patients (63±13 years, 68% male, 50% asymptomatic severe AS) did not undergo intervention (natural history cohort) and 35 patients (67±8 years, 73% male, 83% symptomatic severe AS) underwent aortic valve replacement (AVR) within the first year (AVR cohort). Replacement and diffuse myocardial fibrosis were assessed using the late gadolinium enhancement (LGE) and T1 mapping techniques respectively. Annualised change was calculated for all measures. Results In the natural history cohort, left ventricular mass index (LVMi) increased over time (6%±1%, pConclusion Changes in diffuse fibrosis can be tracked using iECV and increase with time in patients with AS alongside LV mass and replacement fibrosis. Following AVR there is a fall in LV mass driven predominantly by regression of cellular hypertrophy with more gradual reduction in diffuse fibrosis burden but no change in replacement fibrosis. Mid-wall LGE is present on baseline scan (white arrow) and new areas are seen on 1 year scan (red arrows). Following AVR there is no change in mid-wall LGE (white arrows). Annualised change in imaging measures is presented below in the natural history (black) and AVR (red) groups. Main Figure: Serial cardiac magnetic resonance imaging in a patient with severe aortic stenosis.
- Open Access
- 27 August 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (10) , 1883-1890
Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution
- 27 August 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (10) , 1883-1890
Open AccessDynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution
- 1 August 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1064) , 20150780
Iterative reconstruction can permit the use of lower X-ray tube current in CT coronary artery calcium scoring
CT coronary artery calcium scoring (CACS) is additive to traditional risk factors for predicting future cardiac events but is associated with relatively high radiation doses. We assessed the feasibility of CACS radiation dose reduction using a lower tube current and iterative reconstruction (IR). Artificial noise was added to the raw data from 27 CACS studies from patients who were symptomatic to simulate lower tube current scanning (75, 50 and 25% original current). All studies were performed on the same CT scanner at 120 kVp. Data were reconstructed using filtered back projection [Quantum Denoising Software (QDS+)] and IR [adaptive iterative dose reduction three dimensional mild, standard and strong]. Agatston scores were independently measured by two readers. CACS percentile risk scores were calculated. At 75, 50 and 25% tube currents, all adaptive iterative dose reduction (AIDR) reconstructions decreased image noise relative to QDS+ (p < 0.05). All AIDR reconstructions resulted in small reductions in Agatston score relative to QDS+ at the standard tube current (p < 0.05). Agatston scores increased with QDS+ at 75, 50 and 25% tube current (p < 0.05), whereas no significant change was observed with AIDR mild at any tested tube current. No difference in the percentile risk score with AIDR mild at any tube current occurred compared with QDS+ at standard tube current (p > 0.05). Interobserver agreement for AIDR mild remained excellent even at 25% tube current (intraclass correlation coefficient 0.997). Up to 75% reduction in CACS tube current is feasible using AIDR mild. AIDR mild IR permits low tube current CACS whilst maintaining excellent intraobserver and interobserver variability and without altering risk classification.
- 1 August 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1064) , 20150780
Iterative reconstruction can permit the use of lower X-ray tube current in CT coronary artery calcium scoring
CT coronary artery calcium scoring (CACS) is additive to traditional risk factors for predicting future cardiac events but is associated with relatively high radiation doses. We assessed the feasibility of CACS radiation dose reduction using a lower tube current and iterative reconstruction (IR). Artificial noise was added to the raw data from 27 CACS studies from patients who were symptomatic to simulate lower tube current scanning (75, 50 and 25% original current). All studies were performed on the same CT scanner at 120 kVp. Data were reconstructed using filtered back projection [Quantum Denoising Software (QDS+)] and IR [adaptive iterative dose reduction three dimensional mild, standard and strong]. Agatston scores were independently measured by two readers. CACS percentile risk scores were calculated. At 75, 50 and 25% tube currents, all adaptive iterative dose reduction (AIDR) reconstructions decreased image noise relative to QDS+ (p < 0.05). All AIDR reconstructions resulted in small reductions in Agatston score relative to QDS+ at the standard tube current (p < 0.05). Agatston scores increased with QDS+ at 75, 50 and 25% tube current (p < 0.05), whereas no significant change was observed with AIDR mild at any tested tube current. No difference in the percentile risk score with AIDR mild at any tube current occurred compared with QDS+ at standard tube current (p > 0.05). Interobserver agreement for AIDR mild remained excellent even at 25% tube current (intraclass correlation coefficient 0.997). Up to 75% reduction in CACS tube current is feasible using AIDR mild. AIDR mild IR permits low tube current CACS whilst maintaining excellent intraobserver and interobserver variability and without altering risk classification.
- Open Access
- 1 February 2016
- Vol. 6 (1) , 42-49-49
T1 characteristics of interstitial pulmonary fibrosis on 3T MRI-a predictor of early interstitial change?
T1 characteristics of interstitial pulmonary fibrosis on 3T MRI—a predictor of early interstitial change?
- 1 February 2016
- Vol. 6 (1) , 42-49-49
Open AccessT1 characteristics of interstitial pulmonary fibrosis on 3T MRI-a predictor of early interstitial change?
T1 characteristics of interstitial pulmonary fibrosis on 3T MRI—a predictor of early interstitial change?
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 57-12
Quantitative assessment of myocardial blood flow in coronary artery disease by cardiovascular magnetic resonance: comparison of Fermi and distributed parameter modeling against invasive methods
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 57-12
Open AccessQuantitative assessment of myocardial blood flow in coronary artery disease by cardiovascular magnetic resonance: comparison of Fermi and distributed parameter modeling against invasive methods
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 46-9
Ferumoxytol-enhanced magnetic resonance imaging methodology and normal values at 1.5 and 3T
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 46-9
Open AccessFerumoxytol-enhanced magnetic resonance imaging methodology and normal values at 1.5 and 3T
- 1 August 2015
- Published by Elsevier in Clinical Radiology
- Vol. 70 (8) , 844-851
Feasibility of radiation dose reduction using AIDR-3D in dynamic pulmonary CT perfusion
- 1 August 2015
- Published by Elsevier in Clinical Radiology
- Vol. 70 (8) , 844-851
Feasibility of radiation dose reduction using AIDR-3D in dynamic pulmonary CT perfusion