MJMarkus S. Juchems

Markus S. Juchems

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Markus S. Juchems has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Substantial and reversible brain gray matter reduction but no acute brain lesions in ultramarathon runners: experience from the TransEurope-FootRace Project

    by Wolfgang Freund, Sonja Faust, Frank Birklein, Christian Gaser, Arthur P Wunderlich, Marguerite Müller, Christian Billich, Markus S Juchems, Bernd L Schmitz, Georg Grön, et al.

    During the extremely challenging 4,487 km ultramarathon TransEurope-FootRace 2009, runners showed considerable reduction of body weight. The effects of this endurance run on brain volume changes but also possible formation of brain edema or new lesions were explored by repeated magnetic resonance imaging (MRI) studies.


  • Liver Iron Content Determined by MRI: Spin-Echo vs. Gradient-Echo

    by M. S. Juchems, H. Cario, M. Schmid, A. P. Wunderlich

    Purpose: Liver iron content (LIC) measurement plays a central role in the management of patients with transfusional iron overload. Calculating the LIC with data obtained from standardized MRI sequences represents an attractive alternative diagnostic possibility. The purpose of this study was to compare the LIC measurement obtained with gradient-echo (GRE) sequences to the mean liver proton transverse relaxation (R2) acquired with SE sequences. Materials and Methods: 68 patients with iron overload (median age: 24, range: 3 – 88) underwent 1.5 T MRI for liver iron content measurement. All patients received spin-echo (SE) and gradient-echo (GRE) sequences. Results: The two MRI methods revealed different liver iron content results although a significant correlation was found (r = 0.85, p < 0.001). Values evaluated using GRE sequences (median: 260 µmol/g dry weight [d. w.], range: 6 – 732) were generally higher than those obtained by SE examinations (median: 161 µmol /g d. w., range: 5 – 830). Conclusion: In conclusion, our study revealed different results for both MRI measurements, which could lead to different decisions concerning the management of chelation therapy in individual patients. Ziel: Die Bestimmung des Lebereisengehalts (LIC) spielt eine zentrale Rolle im Management von Patienten mit transfusionsbedingter Eisenüberladung. Die nicht invasive LIC-Bestimmung mittels MRT ist eine vielversprechende Untersuchungsmethode. Ziel dieser Studie war es, 2 unterschiedliche MRT-Protokolle zur Lebereisenbestimmung miteinander zu vergleichen – LIC-Bestimmung mittels Gradientenecho-Sequenzen (GRE) vs. LIC-Bestimmung errechnet aus der mittleren Protonenrelaxationszeit (R2) der Leber mittels Spin-Echo-Sequenzen (SE). Material und Methoden: 68 Patienten mit Eisenüberladung (mittleres Alter: 24 Jahre, 3 – 88 Jahre) wurden mit einem 1,5 T MRT untersucht. Alle Patienten erhielten eine LIC-Bestimmung sowohl mit SE- als auch mit und GRE-Sequenzen. Ergebnisse: Beide Untersuchungsmethoden ergaben unterschiedliche LIC-Werte, wobei eine signifikante Korrelation (r = 0,85, p < 0,001) festzustellen war. Die mit GRE-Sequenzen ermittelten Werte (Median: 260 µmol/g Trockengewicht [6 – 732 µmol/g Trockengewicht]) waren generell höher als bei SE-Untersuchungen (Median 161 µmol/g Trockengewicht [5 – 830 µmol/g Trockengewicht]). Schlussfolgerung: Zusammenfassend lässt sich feststellen, dass mit den verschiedenen Messmethoden unterschiedliche LIC-Werte ermittelt wurden. Dies könnte Einfluss auf das individuelle Patientenmanagement bezüglich der Chalationstherapie haben.


  • Moderne Bildgebung beim Rektumkarzinom

    by M.S. Juchems, S. Trnavac


  • Value of MDCT in Preoperative Local Staging of Rectal Cancer for Predicting the Necessity for Neoadjuvant Radiochemotherapy

    by M. S. Juchems, A. S. Ernst, M. Kornmann, T. F. Barth, K. Kramer, H.-J. Brambs, A. J. Aschoff

    Ziel: Neoadjuvante Radiochemotherapie vermindert die Rezidivrate nach totaler Mesorektumextirpation. Diese Studie wurde durchgeführt, um zu prüfen, ob die Multidektektor-Reihen-CT (MDCT) in der Lage ist, zuverlässig zwischen UICC-I-Stadium (Operation) und UICC II–IV (neoadjuvante Radiochemotherapie) zu unterscheiden. Material und Methoden: 29 Patienten erhielten ein präoperatives MDCT des Abdomens in einer venösen Kontrastmittelphase. Zusätzlich wurde rektal H 2O appliziert. Zwei Radiologen werteten die Datensätze retrospektiv geblindet unter Verwendung axialer und koronarer MPR an einer dezidierten Workstation aus. Die lokale Tumorausdehnung (T), der Nodalstatus (N) und die Fernmetastasierung wurden beurteilt und der UICC-Stage bestimmt. Die Ergebnisse wurden mit den postoperativen, histopathologischen Ergebnissen korreliert. Ergebnisse: Nach dem histologischen Ergebnis waren 9 Patienten UICC-Stadium I und 20 Patienten UICC > I (II: 7; III: 11; IV: 2). Auswerter 1 identifizierte 3 / 9 UICC I korrekt und überbewertete 6 / 9 Patienten. 20 / 20 Patienten mit UICC > I wurden korrekt klassifiziert. Auswerter 2 identifizierte 4 / 9 Patienten mit UICC I korrekt, und überbewertete 5 / 9 Patienten. 16 / 20 Patienten mit UICC > I wurden korrekt klassifiziert, 4 / 20 unterbewertet (Auswerter 1 [Auswerter 2]: PPV UICC I 100 % [50 %], NPV 77 % [76 %], Accuracy 79 % [69 %]). Gründe für ein Overstaging durch Auswerter 1 (Auswerter 2) waren unter anderem ein falsch positives Lymphknotenstaging in 5 Fällen (5), überschätzen eines T 1-Tumors als T 3 in 1 Fall (0) und ein T-Overstaging in 4 / 5 (2 / 5) Patienten mit falsch positivem Lymphknotenstaging. Schlussfolgerung: Mit der MDCT ist es nicht möglich, zuverlässig Patienten mit UICC-I-Rektumkarzinom zu identifizieren. Deshalb ist es nicht empfehlenswert, die MDCT als alleinige präoperative Diagnostik anzuwenden, um Patienten zu identifizieren, die von einer neoadjuvanten Radiochemotherapie profitieren würden. Purpose: Neoadjuvant therapy may reduce local rectal cancer recurrence after total mesorectum extirpation. This study was performed to assess whether multi-detector row CT (MDCT) is capable of reliably differentiating UICC I (surgery) from UICC II-IV (neoadjuvant therapy). Materials and Methods: 29 patients underwent preoperative MDCT of the abdomen in a portal venous phase. Two blinded readers independently evaluated the datasets on a dedicated workstation using axial and coronal reformations. Local tumor extension (T), nodal status (N) and distant metastases (M) were evaluated and the UICC stage was determined. Findings were correlated with postoperative histology. Results: Histologically, 9 patients were UICC I; 20 UICC > I (II: 7; III: 11; IV: 2). Reader 1 correctly identified 3 / 9 as UICC I, overstaged 6 / 9, and correctly staged 20 / 20 as UICC > I. Reader 2 correctly identified 4 / 9 as UICC I, overstaged 5 / 9, understaged 4 / 20 and correctly staged 16 / 20 as UICC > I (PPV UICC I 100 % [50 %] reader 1 [reader 2], NPV 77 % [76 %], accuracy 79 % [69 %]). Reasons for overstaging by reader 1 (reader 2) included false-positive lymph nodes (LN) in 5 (5), overgrading T 1 tumors as T 3 in 1(0), and T overgrading in 4 / 5 (2 / 5) patients with false-positive LN. Conclusion: MDCT failed to reliably identify UICC I in rectal cancer patients. Therefore, a strategy based solely on MDCT to identify patients who would benefit from neoadjuvant therapy does not seem appropriate.


  • Aktuelle Bildgebung beim Rektumkarzinom

    by M.S. Juchems, A.J. Aschoff


  • Computer-aided detection in computer tomography colonography: a review

    by Markus S Juchems, Andrea S Ernst, Hans-Juergen Brambs, Andrik J Aschoff

    Colorectal cancer is one of the most common causes of death from cancer. Computer tomography colonography (CTC) - also known as 'virtual colonoscopy' - is a minimally invasive, CT-based procedure that can simulate conventional colonoscopy using three-dimensional computerized reconstructions. In an attempt to improve the method further, a lot of research emphasis has been put on computer-aided detection (CAD) to overcome potential limitations of this examination. This review recapitulates basic principles of CTC and CAD and highlights the importance of this method as a tool for screening for colorectal cancer. This article reviews the current literature on CAD used with CT colonography. CAD potentially helps to improve the detection rate for adenomas, decrease interobserver variability and data set interpretation time.


  • Strongyloides stercoralis: A Rare Cause of Obstructive Duodenal Stenosis

    by Markus S. Juchems, Jan Hendrik Niess, Gerhard Leder, Thomas F. Barth, Guido Adler, Hans-Juergen Brambs, Martin Wagner

    Background: Strongyloidiasis is a rare helminthic infection in Europe, and it may cause duodenal obstruction. Methods: We report a patient who was admitted to our Medical Department with nausea and repeated vomiting since 10 years until food intake became impossible. Subsequent investigations revealed a duodenal obstruction at the upper third of the duodenum, as well as enterocolitis of the terminal ileum with eosinophils dispersed throughout the mucosa. Since food intake was still not possible after treatment with a course of i.v. PPI and prokinetic applications, we decided to perform a resection of the upper duodenum with Y-Roux reconstruction. Results: The histopathological examination of the resected specimen revealed strongyloidiasis. Conclusion: Parasite infections such as strongyloidiasis represent a rare differential diagnosis of duodenal obstruction especially if patients originate from endemic regions.


  • Electronic colon-cleansing for CT colonography: diagnostic performance

    by Markus S. Juchems, Andrea Ernst, Peter Johnson, Sunny Virmani, Hans-Juergen Brambs, Andrik J. Aschoff

    The purpose of this study was to evaluate whether an electronic-colonic-cleansing (ECC) algorithm is beneficial for the diagnostic performance compared to a CT colonography (CTC) evaluation without electronic cleansing in tagged datasets. Two blinded readers evaluated CTC datasets from 79 patients with 153 colorectal polyps confirmed by optical colonoscopy. Cases were read in a randomized order with and without the use of electronic colon-cleansing software. Per-polyp sensitivity, per-polyp/per-patient specificity and reading times (with and without ECC) have been calculated and reported. Per-polyp sensitivity for polyps >6 mm without using ECC was 60.4% (Reader 1: 59.7%, Reader 2: 61.1%), while polyps >10 mm were detected with a sensitivity of 58.3% (Reader 1: 66.7%, Reader 2: 50%). On electronically cleansed datasets, the sensitivity was 73.6% (Reader 1: 76.4%; Reader 2: 70.8%) for polyps >6 mm and 83.3% (Reader 1: 83.3%; Reader 2: 83.3%), respectively. Per-patient specificity was 75% without using cleansing (Reader 1: 68%, Reader 2: 82%) and 81.5% using ECC (Reader 1: 86%, Reader 2: 77%). Reading CTC cases using ECC software improves sensitivity in detecting clinically relevant colorectal polyps.


  • Multiple cystic liver lesions on CT

    by M S Juchems, M Jeltsch, H-J Brambs


  • Open Access

    Monitoring Gastric Filling, Satiety and Gastric Emptying in a Patient with Gastric Balloon Using Functional Magnetic Resonance Imaging–-A Feasibility Report

    by Markus S. Juchems, Deniz Uyak, Andrea S. Ernst, Hans-Juergen Brambs

    Backround: Intragastric balloons are used for short term weight loss therapy in obese. It is possible to monitor the ballon with sonography, however this method is sometimes insufficient in obese patients. Therefore MRI seems to be a potential therapy-monitoring option. Purpose: In this feasibility report we want to demonstrate the potential use of functional MRI in monitoring gastric filling, patient satiation and gastric emptying in a obese patient who previously received intragastric balloon placement. Material and methods: We selected one patient (male, 178 cm, 127 kg, BMI = 40,5 kg/m2) who recently received a gastric balloon and visualized gastric motility in presence of the gastric balloon before and after food intake. Fast cross-sectional images in one breathhold spin echo or gradient echo sequences were aquired. Real-time gastric motion was performed with cine mode. Results: MRI offers perfect visualisation of gastric balloons in obese patients. Gastric filling and emptying can be monitored in correlation to patient satiety sensation. MRI can visualize the gastric balloon with degree of filling and possible leakages. Cine mode sequences demonstrate gastric motility and gastric wall peristalsis. Conclusion: MR is a valuable imaging alternative for patients with intragastric balloons