NBNishant Banait

Nishant Banait

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nishant Banait has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Alan Fenton

    Royal Victoria Infirmary, Newcastle upon Tyne, UK

    1 shared publication
  • Jonathan Wyllie

    James Cook University Hospital, Middlesbrough, UK

    1 shared publication
  • Majd Abu-Harb

    Sunderland Royal Hospital, NICU, Sunderland, UK

    1 shared publication
  • Martin Ward-Platt

    Newcastle Upon Tyne Hospitals NHS Foundation Trust, NICU, Newcastle upon Tyne, UK

    1 shared publication
  • Miranda Splitt

    Department of Genetics, Royal Victoria Infirmary, Newcastle upon Tyne, UK

    1 shared publication
  • Nicola Miller

    National Congenital Anomaly and Rare Disease Registration Service, Public Health England North East, Newcastle upon Tyne, UK

    1 shared publication

Latest Publications

  • Pulse oximetry screening for critical congenital heart disease: a comparative study of cohorts over 11 years

    by Nishant Banait, Martin Ward-Platt, Majd Abu-Harb, Jonathan Wyllie, Nicola Miller, Sundeep Harigopal

    Background: Pulse oximetry (POS) has been proposed as a screening tool for CCHD in newborn. The aim was to identify the effect of POS on the rate of diagnosis after discharge and survival to one year in cases with CCHD. Material and Methods: All cases of CCHD from three tertiary level hospitals in the Northern region of UK between 1st January 2001 and 31st December 2011 were identified from the Northern Congenital Abnormality Survey (NorCAS). A retrospective cohort study comparing screened and unscreened population for CCHD was undertaken. The main outcome was post discharge diagnosis rate and mortality at one year between the cohorts. Results: Total number of births during the 11 years was 138,176. A total of 147 cases had CCHD, 59 diagnosed postnatally. Five and eight cases were diagnosed after discharge in the screened and the unscreened cohort respectively. The rate of post-discharge diagnosis in the screened population was 7/100,000 and 13/100,000 in the unscreened population with a relative risk of 0.52 (CI 0.2 to 1.42). Mortality at one year in postnatally diagnosed cases was five and one in the screened and unscreened cohorts respectively. Conclusion: With good antenatal detection rates, POS did not have a statistically significant impact in identifying cases of CCHD, when added to the present screening process of antenatal ultrasound and postnatal examination. The same conclusion cannot be made for regions with lower antenatal detection rates; perhaps it may be more appropriate to consider pulse oximetry as a screening tool for hypoxemia of any cause. Brief rationale This is the first study evaluating the contemporaneous post-discharge diagnosis rate between screened and unscreened populations. The rate of post-discharge diagnosis was 7/100,000 in the screened and 13/100,000 in the unscreened populations. However, this did not achieve statistical significance and in a setting with high antenatal diagnosis a very large study would be required to demonstrate efficacy of POS.


  • Cornelia de Lange syndrome due to mosaic NIPBL mutation: antenatal presentation with sacrococcygeal teratoma

    by Nishant Banait, Alan Fenton, Miranda Splitt

    A male infant at 36 weeks gestation was born by section. At 20 weeks of gestation, congenital diaphragmatic hernia and sacrococcygeal teratoma had been seen on ultrasound. At birth, the infant had features suggestive of Cornelia de Lange syndrome (CdLS). He remained hypoxic despite aggressive ventilatory manoeuvres and was palliated. At postmortem, the lungs were hypoplastic. In CdLS, mutations in NIPBL are found in around 50% of cases. Mutation analysis, including multiplex ligation dependent probe amplification of the NIPBL gene from the DNA extracted from peripheral blood lymphocytes was negative, but microarray comparative genomic hybridisation on DNA from skin fibroblast showed a 0.13Mb deletion on chromosome 5p13. The deleted region includes exons 42–47 of the NIPBL gene. It is important to perform NIBPL mutation analysis on DNA from more than one tissue when testing for CdLS.


  • Open Access

    Cardiac Blood Flow Measurements in Stable Full Term Small for Gestational Age Neonates

    by Nishant Banait

    Cardiac blood flow measurements are useful in the haemodynamic management of neonates. Cardiac blood flows can be estimated with functional echocardiography as follows; flow in Superior Vena Cava (SVC), Right Ventricular Outflow (RVO) and Left Ventricular Outflow (LVO). Studies in preterm infants have shown that abnormal superior vena cava flow is associated with poor neurodevelopmental outcomes. To date, normative data on LVO, RVO and SVC flows has been established for term appropriate for gestational age neonates and preterm neonates, but no data is available on RVO, LVO and SVC flows for term small for gestational age neonates. To determine Right Ventricular Output (RVO), Left Ventricular Output (LVO) and Superior Vena Cava (SVC) flow after the transitional period in stable full term Small for Gestational Age (SGA) neonates. Observational study. A tertiary care, perinatal centre in western Maharashtra, India. Full term (37 to 41 weeks) small for gestational age (weight below 10th percentile for gestational age) infants who were born during the study period. RVO, LVO and SVC flows were measured by functional echocardiography on day 7 of life in stable full term SGA neonates from January 2011 to August 2011. Infants who required respiratory or cardiovascular support and intensive care unit admissions for any indication and those with a clinical suspicion of an infection within 48 hours after data collection were excluded from the study. Unpaired t-test was used to compare SVC flow between symmetric and asymmetric SGA neonates. Measurements of RVO, LVO and SVC in term SGA neonates on day 7 of life. We performed measurements in 52 term SGA neonates with a median (range) birth weight of 2.190 (1.600-2.410) kg. Fifty two measurements were analyzed on day 7. The mean (SD) RVO, LVO and SVC flows were 255.59 (57.42) , 214.61 (52.04) and 126.28 (31.23) mL/kg/min. This study provides RVO, LVO and SVC flow values in a cohort of stable term SGA neonates after the transitional period.