Kikuhito Kawasue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kikuhito Kawasue has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Kumiko Yoshida
KOYO Plant Services Co., Miyazaki, Japan
6 shared publicationsKhin Dagon Win
Faculty of Engineering, University of Miyazaki, Miyazaki, Japan
4 shared publicationsGeunho Lee
Faculty of Engineering, University of Miyazaki, Miyazaki, Japan
2 shared publications- Khin Dagon Win
Faculty of Engineering, University of Miyazaki, Miyazaki 889-2192, Japan
2 shared publications Takakazu Ishimatsu
2 shared publicationsYuichiro Ohya
2 shared publications
Latest Publications
- Open Access
Why Camera-Based and Scale-Based Measurements Differ: A Physiological Model of Diurnal Weight Variation in Finishing Pigs
Live weight is widely used as a reference indicator for growth performance and for evaluating the accuracy of weight measurement technologies in pig production. However, live weight is not a fixed physiological quantity, and finishing pigs naturally experience substantial short-term mass fluctuations due to normal behaviors such as drinking, feeding, urination, and defecation. In this study, we integrated published physiological and behavioral parameters into a stochastic simulation model to quantify within-day live-weight dynamics in finishing pigs weighing approximately 100 kg. The simulation was conducted with 1-min temporal resolution over a 24-h period. The model demonstrated that short-term weight fluctuations of approximately ±3–5 kg can occur within a single day, even when measurement error is minimal. Across 1000 simulated pigs, the mean daily fluctuation range was 4.2 kg, confirming that kilogram-scale variation is physiologically expected under normal conditions. These results provide a plausible physiological basis for understanding the frequently reported discrepancies between camera-based weight estimates and instantaneous floor-scale measurements. Camera systems primarily reflect body mass derived from external morphology, whereas floor scales measure instantaneous total mass that includes transient contributions from gastrointestinal contents, ingested water, and retained waste. Consequently, direct comparisons based on instantaneous scale readings can be misleading when used as ground truth. Our findings indicate that commonly cited accuracy claims of ±2–3 kg for camera weighing systems should be interpreted with caution, as normal physiological weight variation often exceeds this range. Recognizing live weight as a dynamic physiological variable is essential for developing biologically meaningful evaluation frameworks and for the appropriate interpretation and comparison of weight measurement technologies in precision livestock farming.
Open AccessWhy Camera-Based and Scale-Based Measurements Differ: A Physiological Model of Diurnal Weight Variation in Finishing Pigs
Live weight is widely used as a reference indicator for growth performance and for evaluating the accuracy of weight measurement technologies in pig production. However, live weight is not a fixed physiological quantity, and finishing pigs naturally experience substantial short-term mass fluctuations due to normal behaviors such as drinking, feeding, urination, and defecation. In this study, we integrated published physiological and behavioral parameters into a stochastic simulation model to quantify within-day live-weight dynamics in finishing pigs weighing approximately 100 kg. The simulation was conducted with 1-min temporal resolution over a 24-h period. The model demonstrated that short-term weight fluctuations of approximately ±3–5 kg can occur within a single day, even when measurement error is minimal. Across 1000 simulated pigs, the mean daily fluctuation range was 4.2 kg, confirming that kilogram-scale variation is physiologically expected under normal conditions. These results provide a plausible physiological basis for understanding the frequently reported discrepancies between camera-based weight estimates and instantaneous floor-scale measurements. Camera systems primarily reflect body mass derived from external morphology, whereas floor scales measure instantaneous total mass that includes transient contributions from gastrointestinal contents, ingested water, and retained waste. Consequently, direct comparisons based on instantaneous scale readings can be misleading when used as ground truth. Our findings indicate that commonly cited accuracy claims of ±2–3 kg for camera weighing systems should be interpreted with caution, as normal physiological weight variation often exceeds this range. Recognizing live weight as a dynamic physiological variable is essential for developing biologically meaningful evaluation frameworks and for the appropriate interpretation and comparison of weight measurement technologies in precision livestock farming.
- Open Access
Three-Dimensional Imaging Sensor-Based Non-Contact Measurement of Neonatal Head Circumference in Incubators
In Japan, birth rates are declining, but there are a rising number of underweight newborns who require specialized care in neonatal intensive care units (NICUs). Head circumference is an important indicator of brain development for low-birth-weight infants. However, measuring head circumference requires extreme care because low-birth-weight infants have fragile skin. Therefore, a non-contact measurement system using a 3D imaging sensor was developed. Using this system, three-dimensional data for a newborn’s head can be obtained from outside the incubator. Briefly, the images are taken from above the incubator, so there is an area behind the head that cannot be captured by the camera, but the head circumference estimation takes into account the fact that the head is in contact with the mat. The proposed method allows head circumference estimation without touching the newborn. This approach minimizes stress for both the neonate and the nurse and improves efficiency and safety in the NICU.
Open AccessThree-Dimensional Imaging Sensor-Based Non-Contact Measurement of Neonatal Head Circumference in Incubators
In Japan, birth rates are declining, but there are a rising number of underweight newborns who require specialized care in neonatal intensive care units (NICUs). Head circumference is an important indicator of brain development for low-birth-weight infants. However, measuring head circumference requires extreme care because low-birth-weight infants have fragile skin. Therefore, a non-contact measurement system using a 3D imaging sensor was developed. Using this system, three-dimensional data for a newborn’s head can be obtained from outside the incubator. Briefly, the images are taken from above the incubator, so there is an area behind the head that cannot be captured by the camera, but the head circumference estimation takes into account the fact that the head is in contact with the mat. The proposed method allows head circumference estimation without touching the newborn. This approach minimizes stress for both the neonate and the nurse and improves efficiency and safety in the NICU.
- 18 November 2023
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 29 (1) , 1-6
Pig sorting system with three exits that incorporates an RGB-D sensor for constant use during fattening
- 18 November 2023
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 29 (1) , 1-6
Pig sorting system with three exits that incorporates an RGB-D sensor for constant use during fattening
- 8 November 2022
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 28 (1) , 89-95
Pig weight prediction system using RGB-D sensor and AR glasses: analysis method with free camera capture direction
- 8 November 2022
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 28 (1) , 89-95
Pig weight prediction system using RGB-D sensor and AR glasses: analysis method with free camera capture direction
- 11 October 2020
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 26 (2) , 155-161
Automatic pig selection system based on body size using a camera: rotating mechanics for pig selection
- 11 October 2020
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 26 (2) , 155-161
Automatic pig selection system based on body size using a camera: rotating mechanics for pig selection
- 11 December 2018
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 24 (2) , 155-160
3D measurement of a moving target using multiple slits with a random-dot pattern
- 11 December 2018
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 24 (2) , 155-160
3D measurement of a moving target using multiple slits with a random-dot pattern
- 28 June 2017
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 22 (4) , 464-470
Black cattle body shape and temperature measurement using thermography and KINECT sensor
- 28 June 2017
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 22 (4) , 464-470
Black cattle body shape and temperature measurement using thermography and KINECT sensor
- 1 January 2017
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 83 (3) , 263-268
Three-Dimensional Measurement of Piping Using Multiple Slits with a Random Dot Pattern
- 1 January 2017
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 83 (3) , 263-268
Three-Dimensional Measurement of Piping Using Multiple Slits with a Random Dot Pattern
- Open Access
- 1 January 2013
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 10 (1)
Shape Measurement of a Sewer Pipe Using a Mobile Robot with Computer Vision
A mobile robot equipped with two lasers and a CCD camera for pipe inspection is proposed. Circular laser streaks that appeared on the inner surface of the pipe reveal the shape of the pipe. The 3D shape of a sewer pipe can be reconstructed considering the movement of the mobile robot along the pipe. Since the tilt of the mobile robot with respect to the axis of the pipe appears as the deformation between two circular streaks, the shape of a sewer pipe can be measured accurately, regardless of the tilt of the robot.
- 1 January 2013
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 10 (1)
Open AccessShape Measurement of a Sewer Pipe Using a Mobile Robot with Computer Vision
A mobile robot equipped with two lasers and a CCD camera for pipe inspection is proposed. Circular laser streaks that appeared on the inner surface of the pipe reveal the shape of the pipe. The 3D shape of a sewer pipe can be reconstructed considering the movement of the mobile robot along the pipe. Since the tilt of the mobile robot with respect to the axis of the pipe appears as the deformation between two circular streaks, the shape of a sewer pipe can be measured accurately, regardless of the tilt of the robot.