Pascal Magne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pascal Magne has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Elisa Oderich
Department of Restorative Sciences, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, CA 90089-7792, USA
4 shared publicationsMichel Magne
Master Dental Technician, Beverly Hills Dental Laboratory, Oral Design Center, Los Angeles, Calif
4 shared publicationsAlena Knezevic
3 shared publicationsAntônio Carlos Cardoso
Department of Dentistry Federal University of Santa Catarina – UFSC Florianópolis SC Brazil
3 shared publicationsDomenico Cascione
3 shared publicationsJan-Frederik Güth
3 shared publications
Latest Publications
- 1 October 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (4) , 434-438
M-i-M for DME: matrix-in-a-matrix technique for deep margin elevation
- 1 October 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (4) , 434-438
M-i-M for DME: matrix-in-a-matrix technique for deep margin elevation
- 1 October 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 120 (4) , 573-582
Influence of symmetry and balance on visual perception of a white female smile
- 1 October 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 120 (4) , 573-582
Influence of symmetry and balance on visual perception of a white female smile
- 1 May 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 119 (5) , 769-776
Survival of extensively damaged endodontically treated incisors restored with different types of posts-and-core foundation restoration material
- 1 May 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 119 (5) , 769-776
Survival of extensively damaged endodontically treated incisors restored with different types of posts-and-core foundation restoration material
- 1 April 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (4) , 587-597
Optimization of large MOD restorations: Composite resin inlays vs. short fiber-reinforced direct restorations
- 1 April 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (4) , 587-597
Optimization of large MOD restorations: Composite resin inlays vs. short fiber-reinforced direct restorations
- 1 July 2017
- Published by Operative Dentistry in Operative Dentistry
- Vol. 42 (4) , 396-406
Ferrule-Effect Dominates Over Use of a Fiber Post When Restoring Endodontically Treated Incisors: An In Vitro Study
Objectives: The aim of this study was to investigate the restoration of broken-down endodontically treated incisors with the ferrule effect using glass ceramic crowns bonded to composite resin core buildups with or without a fiber post. A no-ferrule group with post was also included for comparison. Methods and Materials: Thirty decoronated endodontically treated bovine incisors with a 2-mm ferrule were restored with a direct buildup using a nanohybrid direct composite resin (Miris 2 and Optibond FL) with or without a glass-fiber–reinforced post. An additional group of 15 teeth without a ferrule were restored with buildup and a fiber post. All teeth were prepared to receive bonded glass ceramic crowns (e.max CAD luted with Variolink Esthetic DC) and were subjected to accelerated fatigue testing. Cyclic isometric loading was applied to the incisal edge at an angle of 30° and a frequency of 5 Hz, beginning with a load of 100 N (×5000 cycles). A 100 N load increase was applied each 15,000 cycles. Specimens were loaded until failure or to a maximum of 1000 N (×140,000 cycles). Groups were compared using the Kaplan Meier survival analysis (log rank test at p=0.05). Results: None of the tested specimens withstood all 140,000 load cycles. Specimens with posts but without a ferrule were affected by an initial failure phenomenon (wide gap at the lingual margin between the buildup/crown assembly and the root). There was a significant difference in mean survived cycles between the ferrule groups (Fp=73,332× and FNp=73,244×) and the no-ferrule group (50,121×; p=0.001). The addition of a fiber post was not significant in the presence of the ferrule (p=0.884). In both groups with posts, 100% of failures were unrestorable. The no-post group had 47% of restorable and possibly restorable failures. Conclusions: The survival of broken-down nonvital incisors was improved by the presence of the ferrule but not by the fiber-reinforced post. Fiber posts were always detrimental to the failure mode and were not able to compensate for the absence of a ferrule.
- 1 July 2017
- Published by Operative Dentistry in Operative Dentistry
- Vol. 42 (4) , 396-406
Ferrule-Effect Dominates Over Use of a Fiber Post When Restoring Endodontically Treated Incisors: An In Vitro Study
Objectives: The aim of this study was to investigate the restoration of broken-down endodontically treated incisors with the ferrule effect using glass ceramic crowns bonded to composite resin core buildups with or without a fiber post. A no-ferrule group with post was also included for comparison. Methods and Materials: Thirty decoronated endodontically treated bovine incisors with a 2-mm ferrule were restored with a direct buildup using a nanohybrid direct composite resin (Miris 2 and Optibond FL) with or without a glass-fiber–reinforced post. An additional group of 15 teeth without a ferrule were restored with buildup and a fiber post. All teeth were prepared to receive bonded glass ceramic crowns (e.max CAD luted with Variolink Esthetic DC) and were subjected to accelerated fatigue testing. Cyclic isometric loading was applied to the incisal edge at an angle of 30° and a frequency of 5 Hz, beginning with a load of 100 N (×5000 cycles). A 100 N load increase was applied each 15,000 cycles. Specimens were loaded until failure or to a maximum of 1000 N (×140,000 cycles). Groups were compared using the Kaplan Meier survival analysis (log rank test at p=0.05). Results: None of the tested specimens withstood all 140,000 load cycles. Specimens with posts but without a ferrule were affected by an initial failure phenomenon (wide gap at the lingual margin between the buildup/crown assembly and the root). There was a significant difference in mean survived cycles between the ferrule groups (Fp=73,332× and FNp=73,244×) and the no-ferrule group (50,121×; p=0.001). The addition of a fiber post was not significant in the presence of the ferrule (p=0.884). In both groups with posts, 100% of failures were unrestorable. The no-post group had 47% of restorable and possibly restorable failures. Conclusions: The survival of broken-down nonvital incisors was improved by the presence of the ferrule but not by the fiber-reinforced post. Fiber posts were always detrimental to the failure mode and were not able to compensate for the absence of a ferrule.
- 10 April 2017
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY
- Vol. 2 (2) , 238
Restauração biomimética realizada em CAD/CAM com dente natural humano: Relato de um caso acompanhado por 4 anos
- 10 April 2017
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY
- Vol. 2 (2) , 238
Restauração biomimética realizada em CAD/CAM com dente natural humano: Relato de um caso acompanhado por 4 anos
- 1 January 2017
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 117 (1) , 132-137
Numeric simulation of occlusal interferences in molars restored with ultrathin occlusal veneers
- 1 January 2017
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 117 (1) , 132-137
Numeric simulation of occlusal interferences in molars restored with ultrathin occlusal veneers
- 7 October 2016
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY
- Vol. 1 (4) , 720
Integração óptica de materiais CAD/CAM
- 7 October 2016
- Published by Editora Napoleao Ltda ME in THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY
- Vol. 1 (4) , 720
Integração óptica de materiais CAD/CAM
- 20 July 2016
- Vol. 11 (3) , 394-409
Optical integration of CAD/CAM materials.
The optical integration (OI) of monolithic CAD/CAM materials under 4 illuminations was evaluated using a standardized and clinically relevant method. Eighteen inlays were manufactured and placed (glycerin gel). Standardized photos were taken under 4 illuminations (neutral white light direct and indirect illumination, cross-polarized light, fluorescent light). Six evaluators defined the optical integration score (OIS) as the "visibility" of the restoration (0 = worst OI, 4 = optimal OI). The intact tooth served as control. The null hypothesis was that different illuminations did not influence the OI of CAD/CAM inlays. One-way ANOVA, followed by Scheffe's post hoc, was applied (P = 0.05). Neutral light direct illumination: OIS between 2.67 (IPS e.max CAD LT A1, ENAMIC A1) and 3.83 (IPS e.max CAD HT A1) with a mean of 3.28 (± 0.339). Indirect illumination: OIS from 1.00 (Paradigm MZ100 A1) to 2.41 (ENAMIC A1) with a mean of 1.88 (± 0.598). Fluorescent light: OIS between 0.75 and 3.25 with a mean of 1.67 (± 1.025). ENAMIC and VITA BLOCS Mark II showed the best optical integration in fluorescence. IPS e.max CAD, Paradigm MZ 100 demonstrated low fluorescence; Lava Ultimate high fluorescence. OI was influenced by different illumination. A simple method accessible to clinicians for additional evaluation of CAD/CAM materials in daily practice is presented. All materials showed excellent OI under direct illumination with neutral white light. The most pronounced differences in optical integration between tooth and evaluated materials were observed under fluorescent light.
- 20 July 2016
- Vol. 11 (3) , 394-409
Optical integration of CAD/CAM materials.
The optical integration (OI) of monolithic CAD/CAM materials under 4 illuminations was evaluated using a standardized and clinically relevant method. Eighteen inlays were manufactured and placed (glycerin gel). Standardized photos were taken under 4 illuminations (neutral white light direct and indirect illumination, cross-polarized light, fluorescent light). Six evaluators defined the optical integration score (OIS) as the "visibility" of the restoration (0 = worst OI, 4 = optimal OI). The intact tooth served as control. The null hypothesis was that different illuminations did not influence the OI of CAD/CAM inlays. One-way ANOVA, followed by Scheffe's post hoc, was applied (P = 0.05). Neutral light direct illumination: OIS between 2.67 (IPS e.max CAD LT A1, ENAMIC A1) and 3.83 (IPS e.max CAD HT A1) with a mean of 3.28 (± 0.339). Indirect illumination: OIS from 1.00 (Paradigm MZ100 A1) to 2.41 (ENAMIC A1) with a mean of 1.88 (± 0.598). Fluorescent light: OIS between 0.75 and 3.25 with a mean of 1.67 (± 1.025). ENAMIC and VITA BLOCS Mark II showed the best optical integration in fluorescence. IPS e.max CAD, Paradigm MZ 100 demonstrated low fluorescence; Lava Ultimate high fluorescence. OI was influenced by different illumination. A simple method accessible to clinicians for additional evaluation of CAD/CAM materials in daily practice is presented. All materials showed excellent OI under direct illumination with neutral white light. The most pronounced differences in optical integration between tooth and evaluated materials were observed under fluorescent light.
- 16 July 2016
- Vol. 18 (4) , 341-348
Accelerated Fatigue Resistance of Thick CAD/CAM Composite Resin Overlays Bonded with Light- and Dual-polymerizing Luting Resins
Within the limitations of this in vitro study, it can be concluded that although the dual-polymerizing luting material seems to provide better results under extreme conditions, light-polymerizing luting composites in combination with IDS are not contraindicated with thick restorations.
- 16 July 2016
- Vol. 18 (4) , 341-348
Accelerated Fatigue Resistance of Thick CAD/CAM Composite Resin Overlays Bonded with Light- and Dual-polymerizing Luting Resins
Within the limitations of this in vitro study, it can be concluded that although the dual-polymerizing luting material seems to provide better results under extreme conditions, light-polymerizing luting composites in combination with IDS are not contraindicated with thick restorations.