Thomas Nacke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Nacke has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Andreas Barthel
Institute of Bioprocessing and Analytical Measurement Techniques, 37308 Heilbad Heiligenstadt, Germany
2 shared publicationsDieter Beckmann
Institut für Bioprozess- und Analysenmesstechnik e.V., Heilbad Heiligenstadt, Deutschland
2 shared publicationsArndt Göller
Institute of Bioprocessing and Analytical Measurement Techniques
1 shared publication- Brian Patrick Cahill
Leibniz Information Centre for Science and Technology
1 shared publication - Daniel Martin
Institute for Bioprocessing and Analytical Measurement Techniques (iba), 37308 Heiligenstadt, Germany
1 shared publication Dieter Frense
Institute of Bioprocessing and Analytical Measurement Techniques, 37308 Heilbad Heiligenstadt, Germany
1 shared publication
Latest Publications
- Open Access
- 19 November 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (22) , 14395
High-frequency Contactless Sensor for the Detection of Heparin-Induced Thrombocytopenia Antibodies via Platelet Aggregation
Heparin-induced thrombocytopenia (HIT), a severe autoimmune disorder, occurs in patients undergoing heparin therapy. The presence of platelet-activating antibodies against platelet factor 4/Heparin in the blood confirms patients suffering from HIT. The most widely used methods for HIT diagnosis are immunoassays but the results only suit to rule out HIT as the assays provide only around 50% specificity. To confirm HIT, samples with positive results in immunoassays are retested in functional assays (>98% specificity) that track platelet-activating antibodies via platelet aggregation. However, the protocols in functional assays are either time-consuming (due to the requirement of the detection of serotonin release) or require highly trained staff for the visualization of platelets. Here, we applied a cheap and easy-to-use contactless sensor, which employs high-frequency microwaves to detect the changes in the resonant frequency caused by platelet aggregation/activation. Analysis of change in conductivity and permittivity allowed us to distinguish between HIT-like (KKO) and non-HIT-like (RTO) antibodies. KKO caused a stronger reduction of conductivity of platelet samples than RTO. Our results imply that the high-frequency contactless sensor can be a promising approach for the development of a better and easier method for the detection of HIT.
- 19 November 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (22) , 14395
Open AccessHigh-frequency Contactless Sensor for the Detection of Heparin-Induced Thrombocytopenia Antibodies via Platelet Aggregation
Heparin-induced thrombocytopenia (HIT), a severe autoimmune disorder, occurs in patients undergoing heparin therapy. The presence of platelet-activating antibodies against platelet factor 4/Heparin in the blood confirms patients suffering from HIT. The most widely used methods for HIT diagnosis are immunoassays but the results only suit to rule out HIT as the assays provide only around 50% specificity. To confirm HIT, samples with positive results in immunoassays are retested in functional assays (>98% specificity) that track platelet-activating antibodies via platelet aggregation. However, the protocols in functional assays are either time-consuming (due to the requirement of the detection of serotonin release) or require highly trained staff for the visualization of platelets. Here, we applied a cheap and easy-to-use contactless sensor, which employs high-frequency microwaves to detect the changes in the resonant frequency caused by platelet aggregation/activation. Analysis of change in conductivity and permittivity allowed us to distinguish between HIT-like (KKO) and non-HIT-like (RTO) antibodies. KKO caused a stronger reduction of conductivity of platelet samples than RTO. Our results imply that the high-frequency contactless sensor can be a promising approach for the development of a better and easier method for the detection of HIT.
- 27 November 2012
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 85 (1-2) , 179-185
Application of High Frequency Sensors for Contactless Monitoring in Disposable Bioreactors
Contamination‐free process measurement is essential for efficient monitoring of fermenters. This contribution introduces the use of high‐frequency sensors for the contactless measurement of the permittivity and conductivity of fermentation media. As microwaves can penetrate through plastic materials without much attenuation, it is possible to achieve measurement setups that can measure the media under test without any direct contact and with long‐term stability. The sensor can be installed directly to the outer surface of the fermenter or can be clamped onto tubing.
- 27 November 2012
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 85 (1-2) , 179-185
Application of High Frequency Sensors for Contactless Monitoring in Disposable Bioreactors
Contamination‐free process measurement is essential for efficient monitoring of fermenters. This contribution introduces the use of high‐frequency sensors for the contactless measurement of the permittivity and conductivity of fermentation media. As microwaves can penetrate through plastic materials without much attenuation, it is possible to achieve measurement setups that can measure the media under test without any direct contact and with long‐term stability. The sensor can be installed directly to the outer surface of the fermenter or can be clamped onto tubing.
- 20 December 2010
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 78 (1) , 3-14
Messsystem für die impedanzspektroskopische Breitband-Prozessmesstechnik
Zusammenfassung: Robuste Sensoren für die zerstörungsfreie Materialcharakterisierung im Labor und unter rauen industriellen Bedingungen sind von zunehmendem technischen und ökonomischen Interesse. Dieser Artikel behandelt die Entwicklung und Anwendung eines prozesstauglichen, modularen und breitbandigen impedanzspektroskopischen Hard- und Softwarekonzepts für den Feld- und Laboreinsatz. Besondere Beachtung finden weiterhin auch technische und biophysikalische Aspekte der Bio-Impedanzspektroskopie.
- 20 December 2010
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 78 (1) , 3-14
Messsystem für die impedanzspektroskopische Breitband-Prozessmesstechnik
Zusammenfassung: Robuste Sensoren für die zerstörungsfreie Materialcharakterisierung im Labor und unter rauen industriellen Bedingungen sind von zunehmendem technischen und ökonomischen Interesse. Dieser Artikel behandelt die Entwicklung und Anwendung eines prozesstauglichen, modularen und breitbandigen impedanzspektroskopischen Hard- und Softwarekonzepts für den Feld- und Laboreinsatz. Besondere Beachtung finden weiterhin auch technische und biophysikalische Aspekte der Bio-Impedanzspektroskopie.
- 29 October 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 383 (5) , 752-757
New type of dry substances content meter using microwaves for application in biogas plants
Dry substances (DS) are an important index for monitoring and controlling anaerobic co-digestion in biogas plants. We have developed and tested an online meter that measures suspended solids by means of the reflection coefficient of an exiting microwave signal, which is dependent on the dielectric properties of the suspensions. Intelligent models based on partial least squares regression (PLSR) and artificial neural network (ANN) for calibration allow exact and reproducible measurements under different circumstances. This measuring method is appropriate for contactless and online measurements of dry substance contents in biogas plants in a large range from 2–14%.
- 29 October 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 383 (5) , 752-757
New type of dry substances content meter using microwaves for application in biogas plants
Dry substances (DS) are an important index for monitoring and controlling anaerobic co-digestion in biogas plants. We have developed and tested an online meter that measures suspended solids by means of the reflection coefficient of an exiting microwave signal, which is dependent on the dielectric properties of the suspensions. Intelligent models based on partial least squares regression (PLSR) and artificial neural network (ANN) for calibration allow exact and reproducible measurements under different circumstances. This measuring method is appropriate for contactless and online measurements of dry substance contents in biogas plants in a large range from 2–14%.