Hiroyuki Daido
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroyuki Daido has a total of 178 co-authors. Here are the top co-authors by number of shared publications:
Y. Kato
Japan Atomic Energy Agency and The Graduate School for the Creation of New Photonics Industries, Japan
17 shared publicationsK. Murai
8 shared publicationsT. Kawachi
Japan Atomic Energy Agency, Japan
7 shared publications- R. Kodama
Institute of Laser Engineering, Osaka University, Yamada-oka 2-6, Suita, Osaka 565-0871, Japan
6 shared publications - Anatoly Ya. Faenov
Osaka University
5 shared publications - Masaki Kando
The University of Osaka
5 shared publications
Latest Publications
- 11 July 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1465 (1) , 159
X-ray emission from relativistically moving electron density cusps
We report on novel methods to generate ultra-short, coherent, X-rays using a laserplasma interaction. Nonlinear interaction of intense laser pulses with plasma creates stable, specific structures such as electron cusps. For example, wake waves excited in an underdense plasma by an intense, short-pulse laser become dense and propagate along with the laser pulse. This is called a relativistic flying mirror. The flying mirror can reflect a counter-propagating laser pulse and directly convert it into high-frequency radiation, with a frequency multiplication factor of ∼ 4γ2 and pulse shortening with the same factor. After the proof-of-principle experiments, we observed that the photon number generated in the flying mirror is close to the theoretical estimate. We present the details of the experiment in which a 9 TW laser pulse focused into a He gas jet generated the Flying Mirror, which partly reflected a 1 TW pulse, giving up to ∼ 1010 photons, 60 nJ ( photons/sr) in the XUV spectral region (12.8-22 nm).- 11 July 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1465 (1) , 159
X-ray emission from relativistically moving electron density cusps
We report on novel methods to generate ultra-short, coherent, X-rays using a laserplasma interaction. Nonlinear interaction of intense laser pulses with plasma creates stable, specific structures such as electron cusps. For example, wake waves excited in an underdense plasma by an intense, short-pulse laser become dense and propagate along with the laser pulse. This is called a relativistic flying mirror. The flying mirror can reflect a counter-propagating laser pulse and directly convert it into high-frequency radiation, with a frequency multiplication factor of ∼ 4γ2 and pulse shortening with the same factor. After the proof-of-principle experiments, we observed that the photon number generated in the flying mirror is close to the theoretical estimate. We present the details of the experiment in which a 9 TW laser pulse focused into a He gas jet generated the Flying Mirror, which partly reflected a 1 TW pulse, giving up to ∼ 1010 photons, 60 nJ ( photons/sr) in the XUV spectral region (12.8-22 nm).- 11 July 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1465 (1) , 172
High-order harmonics from bow wave caustics driven by a high-intensity laser
We propose a new mechanism of high-order harmonic generation during an interaction of a high-intensity laser pulse with underdense plasma. A tightly focused laser pulse creates a cavity in plasma pushing electrons aside and exciting the wake wave and the bow wave. At the joint of the cavity wall and the bow wave boundary, an annular spike of electron density is formed. This spike surrounds the cavity and moves together with the laser pulse. Collective motion of electrons in the spike driven by the laser field generates high-order harmonics. A strong localization of the electron spike, its robustness to oscillations imposed by the laser field and, consequently, its ability to produce high-order harmonics is explained by catastrophe theory. The proposed mechanism explains the experimental observations of high-order harmonics with the 9 TW J-KAREN laser (JAEA, Japan) and the 120 TW Astra Gemini laser (CLF RAL, UK) [A. S. Pirozhkov, et al., arXiv:1004.4514 (2010); A. S. Pirozhkov et al, AIP Proceedings, this volume]. The theory is corroborated by high-resolution two-and three-dimensional particle-in-cell simulations.
- 11 July 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1465 (1) , 172
High-order harmonics from bow wave caustics driven by a high-intensity laser
We propose a new mechanism of high-order harmonic generation during an interaction of a high-intensity laser pulse with underdense plasma. A tightly focused laser pulse creates a cavity in plasma pushing electrons aside and exciting the wake wave and the bow wave. At the joint of the cavity wall and the bow wave boundary, an annular spike of electron density is formed. This spike surrounds the cavity and moves together with the laser pulse. Collective motion of electrons in the spike driven by the laser field generates high-order harmonics. A strong localization of the electron spike, its robustness to oscillations imposed by the laser field and, consequently, its ability to produce high-order harmonics is explained by catastrophe theory. The proposed mechanism explains the experimental observations of high-order harmonics with the 9 TW J-KAREN laser (JAEA, Japan) and the 120 TW Astra Gemini laser (CLF RAL, UK) [A. S. Pirozhkov, et al., arXiv:1004.4514 (2010); A. S. Pirozhkov et al, AIP Proceedings, this volume]. The theory is corroborated by high-resolution two-and three-dimensional particle-in-cell simulations.
- 24 July 2009
- Published by AIP Publishing
- Vol. 1153 (1) , 85-93
Ion acceleration in the interaction of short pulse laser radiation with the cluster-gas target
We demonstrate generation of ions with a compact 4 TW laser using a gas target mixed with submicron clusters, corresponding to tenfold increase in the ion energies compared to previous experiments with solid targets. It is inferred that the high energy ions are generated due to formation of a strong dipole vortex structure. The demonstrated method has a potential to construct compact and high repetition rate ion sources for hadron therapy and other applications.- 24 July 2009
- Published by AIP Publishing
- Vol. 1153 (1) , 85-93
Ion acceleration in the interaction of short pulse laser radiation with the cluster-gas target
We demonstrate generation of ions with a compact 4 TW laser using a gas target mixed with submicron clusters, corresponding to tenfold increase in the ion energies compared to previous experiments with solid targets. It is inferred that the high energy ions are generated due to formation of a strong dipole vortex structure. The demonstrated method has a potential to construct compact and high repetition rate ion sources for hadron therapy and other applications.- 24 July 2009
- Published by AIP Publishing
- Vol. 1153 (1) , 416-425
Contact and Phase-Contrast Imaging of Nanostructures by Femtosecond-Laser-Driven-Cluster-Based Debris-Free Soft X-Ray Source
The high‐intensive source of soft X‐ray emission was developed by femtosecond laser pulses irradiation of submicron size clusters, produced in custom designed super‐sonic nozzle while mixing the expanding gases. The LiF crystal soft X‐ray detectors have been used for obtaining absorption images of ultrathin (nanoscale) foils and biological structures illuminated by the developed source. It was demonstrated that even if the foil is essentially transparent for the soft X‐ray radiation (like 100 nm thick Zr foil), the image contrast could be significantly increased due to the influence of propagation‐based phase‐contrast effect, by placing the detector at the proper distance from the sample.- 24 July 2009
- Published by AIP Publishing
- Vol. 1153 (1) , 416-425
Contact and Phase-Contrast Imaging of Nanostructures by Femtosecond-Laser-Driven-Cluster-Based Debris-Free Soft X-Ray Source
The high‐intensive source of soft X‐ray emission was developed by femtosecond laser pulses irradiation of submicron size clusters, produced in custom designed super‐sonic nozzle while mixing the expanding gases. The LiF crystal soft X‐ray detectors have been used for obtaining absorption images of ultrathin (nanoscale) foils and biological structures illuminated by the developed source. It was demonstrated that even if the foil is essentially transparent for the soft X‐ray radiation (like 100 nm thick Zr foil), the image contrast could be significantly increased due to the influence of propagation‐based phase‐contrast effect, by placing the detector at the proper distance from the sample.- 24 July 2009
- Published by AIP Publishing
- Vol. 1153 (1) , 343
Femtosecond-Laser-Driven Cluster-Based Plasma Source for High-Resolution Ionography
The intense isotropic source of multicharged ions, with energy above 300 keV, was produced by femtosecond Ti:Sa laser pulses irradiation (intensity of ) of the He and gases mixture expanded in supersonic jet. High contrast ionography images have been obtained for 2000 dpi metal mesh, 1 μm polypropylene and 100 nm Zr foils, as well as for different biological objects. Images were recorded on 1 mm thick CR‐39 ion detector placed in contact with back surface of the imaged samples, at the distances 140–160 mm from the plasma source. The obtained spatial resolution of the image was ∼600 nm. A 100 nm object thickness difference was resolved very well for both Zr and polymer foils. The multicharged ion energy for Carbon and Oxygen ions passing through the 1 μm polypropylene foil is estimated to give the energy of more than 300 keV. An almost equal number of ions were measured with total number of about per shot at a different direction from plasma source. Easy production of different sub‐MeV ions in wide space angle, recognizes femtosecond‐laser‐driven‐cluster‐based plasma as a well‐suited bright source for novel type of submicron ionography to image different media, including nanofoils, membranes, and other low‐contrast objects.- 24 July 2009
- Published by AIP Publishing
- Vol. 1153 (1) , 343
Femtosecond-Laser-Driven Cluster-Based Plasma Source for High-Resolution Ionography
The intense isotropic source of multicharged ions, with energy above 300 keV, was produced by femtosecond Ti:Sa laser pulses irradiation (intensity of ) of the He and gases mixture expanded in supersonic jet. High contrast ionography images have been obtained for 2000 dpi metal mesh, 1 μm polypropylene and 100 nm Zr foils, as well as for different biological objects. Images were recorded on 1 mm thick CR‐39 ion detector placed in contact with back surface of the imaged samples, at the distances 140–160 mm from the plasma source. The obtained spatial resolution of the image was ∼600 nm. A 100 nm object thickness difference was resolved very well for both Zr and polymer foils. The multicharged ion energy for Carbon and Oxygen ions passing through the 1 μm polypropylene foil is estimated to give the energy of more than 300 keV. An almost equal number of ions were measured with total number of about per shot at a different direction from plasma source. Easy production of different sub‐MeV ions in wide space angle, recognizes femtosecond‐laser‐driven‐cluster‐based plasma as a well‐suited bright source for novel type of submicron ionography to image different media, including nanofoils, membranes, and other low‐contrast objects.- 30 June 2008
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1024 (1) , 215
High energy electron acceleration with PW-class laser system
We performed electron acceleration experiment with PW‐class laser and a plasma tube, which was created by imploding a hollow polystyrene cylinder. In this experiment, electron energies in excess of 600 MeV have been observed. Moreover, the spectra of a comparatively high‐density plasma had a bump around 10 MeV. Additionally, we performed the absolute sensitivity calibration of imaging plate for 1 GeV electrons from the injector Linac of Spring‐8 in order to evaluate absolute number of GeV‐class electrons in the laser acceleration experiment.- 30 June 2008
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1024 (1) , 215
High energy electron acceleration with PW-class laser system
We performed electron acceleration experiment with PW‐class laser and a plasma tube, which was created by imploding a hollow polystyrene cylinder. In this experiment, electron energies in excess of 600 MeV have been observed. Moreover, the spectra of a comparatively high‐density plasma had a bump around 10 MeV. Additionally, we performed the absolute sensitivity calibration of imaging plate for 1 GeV electrons from the injector Linac of Spring‐8 in order to evaluate absolute number of GeV‐class electrons in the laser acceleration experiment.- 21 June 2004
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 705 (1) , 1122
Observation of the Ferroelectric Material with Instantaneous X-ray Laser Speckles
Picosecond x‐ray speckles experiment has been conducted with a simple setup. The source was a compact silver‐plasma‐based x‐ray laser, with a wavelength of 13.9 nm and pulse duration of 7 ps. The sample was a single crystal of BaTiO3, with ferroelectric multi‐domain structure (a/c domains). The matter correlation function, including statistical information of those randomly distributed scatterers (domains here) within the sample, was extracted by deconvolution of the speckle pattern. The instantaneous x‐ray speckle technique has proved to be particularly efficient to be used to observe fast microscopic‐scale phenomena that are hard to access with other methods currently.
- 21 June 2004
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 705 (1) , 1122
Observation of the Ferroelectric Material with Instantaneous X-ray Laser Speckles
Picosecond x‐ray speckles experiment has been conducted with a simple setup. The source was a compact silver‐plasma‐based x‐ray laser, with a wavelength of 13.9 nm and pulse duration of 7 ps. The sample was a single crystal of BaTiO3, with ferroelectric multi‐domain structure (a/c domains). The matter correlation function, including statistical information of those randomly distributed scatterers (domains here) within the sample, was extracted by deconvolution of the speckle pattern. The instantaneous x‐ray speckle technique has proved to be particularly efficient to be used to observe fast microscopic‐scale phenomena that are hard to access with other methods currently.
- 1 March 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 104, 141-143
Development of soft X-ray microscopy System using X-ray laser in JAERI Kansai
Journal de Physique IV, Journal de Physique Archives représente une mine d informations facile à consulter sur la manière dont la physique a été publiée depuis 1872.
- 1 March 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 104, 141-143
Development of soft X-ray microscopy System using X-ray laser in JAERI Kansai
Journal de Physique IV, Journal de Physique Archives représente une mine d informations facile à consulter sur la manière dont la physique a été publiée depuis 1872.
- 30 October 2002
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 641 (1) , 522
Picosecond Fourier holography using a Lloyd’s mirror and an X-ray laser at 13.9 nm
Holographic capability of a Lloyd’s mirror wavefront‐splitting interferometer was experimentally investigated. The radiation source was a TCE Ni‐like Ag X‐ray laser at 13.9 nm, routinely operated at JAERI. The X‐ray beam was focused down to a point located a few centimeters in front of the close edge of the Lloyd’s mirror, in order to produce a near‐spherical diverging wave a portion of which, upon reflection by the mirror, recombines with the portion of the wave propagating in free space. The holographic capability of the setup was examined in two configurations. In the first configuration, pertinent to a transmission holography, a test object consisting of a 50‐μm wire was used to produce a diffracted wave encoded as holographic information in the generated interferogram. In the second configuration, SnO2 powder with grains of ≈100 nm, deposited on the Lloyd’s mirror surface, was used to demonstrate a reflection hologram. The data obtained in both cases show that the Lloyd’s mirror is a convenient setup for holographic probing with high spatial resolution.
- 30 October 2002
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 641 (1) , 522
Picosecond Fourier holography using a Lloyd’s mirror and an X-ray laser at 13.9 nm
Holographic capability of a Lloyd’s mirror wavefront‐splitting interferometer was experimentally investigated. The radiation source was a TCE Ni‐like Ag X‐ray laser at 13.9 nm, routinely operated at JAERI. The X‐ray beam was focused down to a point located a few centimeters in front of the close edge of the Lloyd’s mirror, in order to produce a near‐spherical diverging wave a portion of which, upon reflection by the mirror, recombines with the portion of the wave propagating in free space. The holographic capability of the setup was examined in two configurations. In the first configuration, pertinent to a transmission holography, a test object consisting of a 50‐μm wire was used to produce a diffracted wave encoded as holographic information in the generated interferogram. In the second configuration, SnO2 powder with grains of ≈100 nm, deposited on the Lloyd’s mirror surface, was used to demonstrate a reflection hologram. The data obtained in both cases show that the Lloyd’s mirror is a convenient setup for holographic probing with high spatial resolution.