AAArif Asif

Arif Asif

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arif Asif has a total of 133 co-authors. Here are the top co-authors by number of shared publications:

  • Donna Merrill

    Nephrology and Hypertension, University of Miami Miller School of Medicine, Miami, Florida

    19 shared publications
  • Loay Salman

    Interventional Nephrology, University of Miami Miller School of Medicine, Miami, Florida

    10 shared publications
  • Carlos Leon

    Department of Medicine, Division of Nephrology, University of Miami Miller School of Medicine, Miami, Florida 33136, USA

    7 shared publications
  • David Roth

    Department of Medicine, Division of Nephrology, University of Miami Miller School of Medicine, Miami, Florida; and

    7 shared publications
  • Phillip Pennell

    Section of Interventional Nephrology, Division of Nephrology, University of Miami Miller School of Medicine, Miami, Florida

    6 shared publications
  • Florin Gadalean

    Interventional Nephrology, Nephrology Associates of Central Florida, Orlando, Florida

    5 shared publications

Latest Publications

  • Open Access

    Heroin Epidemic and Acute Kidney Injury: An Under-Recognized but Important Consequence of Opioid Overdose

    by Mohammad A. Hossain, Hetavi Mahida, Attiya Haroon, Eric J. Costanzo, James Consentino, Loay Salman, Arif Asif


    • 1 May 2014
      • Vol. 8  (3) , 252-6

    Pre-uremic calciphylaxis.

    by Ali Nayer, Sharad Virmani, Maria Gonzalez-Suarez, Elvia Goez-Gutierrez, Andrew E Rosenberg, Loay H Salman, Arif Asif

    Calciphylaxis is characterized by calcification and thrombosis of arteries resulting in ischemic necrosis of predominantly skin and subcutaneous tissue. Primarily affecting patients with end-stage renal disease, calciphylaxis is diagnosed rarely in the absence of renal replacement therapy. We report an elderly obese woman presented with leg pain and ulceration. She had chronic kidney disease, diabetes mellitus, hypertension, and peripheral vascular disease. Angiography revealed occlusion of the left superficial femoral, popliteal, and distal tibial arteries. Amputation was performed. Histological examination demonstrated medial calcification, intimal hyperplasia, and thrombosis of small- and medium-sized arteries in the subcutaneous tissue. This case features calciphylaxis in a patient with chronic kidney disease before the onset of uremia. Calciphylaxis and atherosclerotic peripheral vascular disease have several risk factors in common. This report calls attention to a disorder that can be masqueraded as leg ulceration due to peripheral vascular disease in the absence of renal replacement therapy.


  • Safety of Brachial Arteriogram using a 3-French Dilator to Evaluate Nonmaturing Arteriovenous Fistulae

    by Tushar J. Vachharajani, Arif Asif

    Nonmaturing arteriovenous fistula remains a hurdle in improving the fistula rate in the hemodialysis population. Timely referral can assist in salvaging fistula with endovascular interventions. Pathology at the inflow segment is frequently encountered as a primary reason for maturation failure. Conventional retrograde angiography can result in poor delineation of the inflow segment and may not be an ideal method for evaluating nonmaturing fistulae. Moreover, the risk of vascular rupture and overzealous diagnosis of accessory veins often result in additional unnecessary therapeutic interventions. Alternatively, a direct brachial arteriogram can provide complete anatomic delineation to perform appropriate endovascular interventions.


  • Prevalence of Chronic Kidney Disease in Patients Undergoing Cardiac Rhythm Device Removal

    by Arif Asif, Roger Carrillo, Juan Domingo Garisto, Mauricio Monrroy, Rao Ali Hashim Khan, Hector Castro, Donna Merrill, Ayesha S. Ali, Amy Barton Pai, Jonathan Waldman, et al.

    Cardiac implantable electronic device (CIED) leads can cause central venous stenosis (CVS). In addition, these devices can get infected. Both are critically important considerations in patients with chronic kidney disease (CKD) for at least two reasons: (i) central veins serve as the final pathway should these patients need an arteriovenous access to provide dialysis therapy; and (ii) the presence of renal failure increases the risk of CIED infection. In this analysis, we investigated the prevalence as well as the degree of chronic kidney disease in patients harboring a CIED. Patients undergoing CIED removal were evaluated from 2001 to 2011. The patients were categorized into CKD stage I-V based on National Kidney Foundation-Dialysis Outcomes Quality Initiative guidelines. A total of 503 patients underwent CIED removal. Demographic characteristics revealed that 30% had hypertension, 44% were diabetics, 77% had coronary artery disease, and 84% suffered from congestive heart failure. Ninety percent (452/503) of the patients had CKD (stage I = I9 [4.2%], stage II = 189 [41.8%], stage III A = 96 [21.2%], stage III B = 59 [13.0%], stage IV = 45 [9.9%], and stage V = 44 [9.7%]). Overall, 148 (32.7%) patients (stage III B, stage IV, and stage V) of 452 had advanced renal failure. The results of this study reveal that one-third of CIED patients undergoing device removal have advanced chronic kidney disease.


  • Transvenous Cardiac Implantable Electronic Devices and Hemodialysis Catheters: Recommendations to Curtail a Potentially Lethal Combination

    by Arif Asif, Loay Salman, Gustavo Lopera, Syed S. Haqqie, Roger Carrillo

    Abnormal renal function is an independent risk factor for cardiac implantable electronic device (CIED) infection. The risk of CIED infection increases as the degree of renal dysfunction worsens with the highest risk observed in patients with stage V chronic kidney disease. A significant portion of these patients use a tunneled hemodialysis catheter (TDC) for dialysis therapy. These devices are associated with very high rates of catheter‐related bacteremia (1.6–5.5 episodes of bacteremia per 1000 catheter days), and have been known to cause infection of CIED indwelling in the bloodstream. In this context, the cardiac device is exposed to the risk of infection due to the presence of renal failure and episodes of bacteremia related to TDCs. Both increase the risk of CIED infection. Once infected, a cardiac rhythm device carries a marked increase in morbidity and mortality. In this context, the combination of a TDC and a CIED indwelling in the bloodstream becomes a potentially deadly combination. Recent data have emphasized that epicardial CIED implantation reduces cardiac device infection in TDC patients. This report highlights the risk of CIED infection in renal patients, presents TDC’s contribution to the cardiac device infection, and suggests recommendations to minimize the risk of CIED infection in chronic hemodialysis patients dialyzing with a TDC.


  • High Brachial Artery Bifurcation: Clinical Considerations and Practical Implications for an Arteriovenous Access

    by Kaveh Kian, Joshua A. Shapiro, Loay Salman, Rao Ali Hashim Khan, Donna Merrill, Leonel Garcia, Nadia Eid, Arif Asif, Adam Aldahan, Gerald Beathard

    High brachial artery bifurcation (HiBAB) is not a rare occurrence. Recent data have emphasized that HiBAB can have major clinical implications including high failure rate and decreased functional patency of an arteriovenous (AV) fistula. In this retrospective study, we investigated the incidence of HiBAB. Patients with advanced chronic kidney disease and end‐stage renal disease on chronic hemodialysis undergoing preoperative vascular mapping for the creation of an AV access were included in this analysis. Ultrasound examination was used to map the arteries of the upper extremities. Four hundred and eighty‐one arms in 340 patients were examined (right arm = 181, left arm = 300). Sixty‐nine of the 481 (12.3%) demonstrated HiBAB. The internal diameter of the radial and ulnar arteries measured at the elbow region was found to be 2.9 ± 0.8 and 3.6 ± 1.0 mm, respectively (p = 0.0001). There were no statistically significant differences in terms of race, gender, and right versus left arms regarding the incidence of HiBAB. As HiBAB can be present in a significant number of patients and have an impact on the AV access, its presence should be evaluated during vascular mapping prior to an AV access creation.


  • Arteriovenous dialysis access-associated transvenous pacemaker infection

    by R.G. Carrillo, J.D. Garisto, L. Salman, A. Asif

    Pacemaker (PM), implantable cardioverter defibrillator and cardiac resynchronization therapy devices also provide support to chronic hemodialysis patients with cardiac rhythm abnormalities. However, these devices can get infected. In general, device infection is either primary or metastatic spread from a distant source. Arteriovenous grafts are commonly used to provide dialysis therapy. Compared to a fistula an arteriovenous graft runs a higher risk of infection. In this analysis, we report 2 chronic hemodialysis patients who have been successfully receiving dialysis through an arteriovenous graft for approximately 2 years. Both had had a PM device for about the same duration. Access infection necessitated surgical removal of the arteriovenous graft in these patients. However, due to bacteremia (methicillin-resistant Staphylococcal aureus (MRSA)), infection spread to involve the transvenous PM leads in both patients. In 1 patient the infection also involved the PM pocket. Lead and wound culture confirmed MRSA in both patients. PM device and leads were removed in both patients. After the resolution of bacteremia, both patients received an epicardial pacemaker. None of the patients had valvular endocarditis. While dialysis was provided with a catheter, an arteriovenous fistula was planned. In conclusion, contamination of the transvenous PM device can occur due to hematogenous spread of infection from an infected arteriovenous graft. Epicardial instead of a transvenous PM might be the better option for such patients to provide long-term cardiac rhythm support.


  • Epicardial Cardiac Rhythm Devices for Dialysis Patients: Minimizing the Risk of Infection and Preserving Central Veins

    by Arif Asif, Roger Carrillo, Juan‐Domingo Garisto, Gustavo Lopera, Marco Ladino, Urwa Barakat, Nadia Eid, Loay Salman

    Transvenous leads of cardiac rhythm devices (CRDs) are known to cause central stenosis and are vulnerable to contamination during hemodialysis access‐related bacteremia. In this retrospective study, nine consecutive chronic hemodialysis patients with transvenous CRD infection due to dialysis access‐related bacteremia and recurrent central stenosis are presented. Four patients with tunneled hemodialysis catheters (TDCs) and three with arteriovenous grafts experienced access‐related bacteremia that spread to the transvenous CRD. Two patients required repeated angioplasty procedures (less than 3 months apart) for central venous stenosis. Transvenous CRD was removed and replaced with an epicardial system in all. One patient with TDC switched to peritoneal dialysis and did not experience infection of the epicardial system despite two episodes of peritonitis. The remaining TDC (n = 3) and graft patients (n = 3) received a new TDC after the resolution of bacteremia. While all six experienced on average 1.5 episodes of catheter‐related bacteremia (average follow‐up = 14.5 months), none developed infection of the epicardial system. The patients with central stenosis have required only one angioplasty each for the past 8 and 6 months. To the best of our knowledge this is the first study to suggest that an epicardial approach might be a preferred method over transvenous leads for chronic hemodialysis patients.