RSRamin Sebastian Sahebjavaher

Ramin Sebastian Sahebjavaher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ramin Sebastian Sahebjavaher has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MR elastography of prostate cancer: quantitative comparison with histopathology and repeatability of methods

    by Ramin S. Sahebjavaher, Guy Nir, Mohammad Honarvar, Louis O. Gagnon, Joseph Ischia, Edward C. Jones, Silvia D. Chang, Ladan Fazli, S. Larry Goldenberg, Robert Rohling, et al.

    The purpose of this work was to assess trans‐perineal prostate magnetic resonance elastography (MRE) for (1) repeatability in phantoms/volunteers and (2) diagnostic power as correlated with histopathology in prostate cancer patients.The three‐dimensional (3D) displacement field was obtained using a fractionally encoded gradient echo sequence using a custom‐made transducer. The repeatability of the method was assessed based on three repeat studies and by changing the driving frequency by 3% in studies on a phantom and six healthy volunteers. Subsequently, 11 patients were examined with MRE prior to radical prostatectomy. The areas under the receiver operating characteristic curves were calculated using a windowed voxel‐to‐voxel approach by comparing the 2D registered slides, masked with the Gleason score.For the repeatability study, the average intraclass correlation coefficient for elasticity images was 99% for repeat phantom studies, 98% for ±6 Hz phantom studies, 95% for volunteer repeat studies with 2 min acquisition time, 82% for ±2 Hz volunteer studies with 2 min acquisition time and 73% for repeat volunteer studies with 8 min acquisition time. For the patient study, the average elasticity was 8.2 ± 1.7 kPa in the prostate capsule, 7.5 ± 1.9 kPa in the peripheral zone (PZ), 9.7 ± 3.0 kPa in the central gland (CG) and 9.0 ± 3.4 kPa in the transition zone. In the patient study, cancerous tissue with Gleason score at least 3 + 3 was significantly (p < 0.05) different from normal tissue in 10 out of 11 cases with tumors in the PZ, and 6 out of 9 cases with tumors in the CG. However, the overall case‐averaged area under the curve was 0.72 in the PZ and 0.67 in the CG.Cancerous tissue was not always stiffer than normal tissue. The inversion algorithm was sensitive to (i) vibration amplitude and displacement nodes and (ii) misalignment of the 3D wave field due to subject movement. Copyright © 2014 John Wiley & Sons, Ltd.


  • MR elastography and diffusion‐weighted imaging of ex vivo prostate cancer: quantitative comparison to histopathology

    by Ramin S. Sahebjavaher, Guy Nir, Louis O. Gagnon, Joseph Ischia, Edward C. Jones, Silvia D. Chang, Andrew Yung, Mohammad Honarvar, Ladan Fazli, S. Larry Goldenberg, et al.

    The purpose of this work was (1) to develop a magnetic resonance elastography (MRE) system for imaging of the ex vivo human prostate and (2) to assess the diagnostic power of mono‐frequency and multi‐frequency MRE and diffusion weighted imaging (DWI) alone and combined as correlated with histopathology in a patient study.An electromagnetic driver was designed specifically for MRE studies in small‐bore MR scanners. Ex vivo prostate specimens (post‐fixation) of 14 patients who underwent radical prostatectomy were imaged with MRE at 7 T (nine cases had DWI). In six patients, the MRE examination was performed at three frequencies (600, 800, 1000 Hz) to extract the power‐law exponent Gamma. The images were registered to wholemount pathology slides marked with the Gleason score. The areas under the receiver‐operator‐characteristic curves (AUC) were calculated.The methods were validated in a phantom study and it was demonstrated that (i) the driver does not interfere with the acquisition process and (ii) the driver can generate amplitudes greater than 100 µm for frequencies less than 1 kHz. In the quantitative study, cancerous tissue with Gleason score at least 3 + 3 was distinguished from normal tissue in the peripheral zone (PZ) with an average AUC of 0.75 (Gd), 0.75 (Gl), 0.70 (Gamma‐Gd), 0.68 (apparent diffusion coefficient, ADC), and 0.82 (Gd + Gl + ADC). The differentiation between PZ and central gland was modest for Gd (p < 0.07), Gl (p < 0.06) but not significant for Gamma (p < 0.2). A correlation of 0.4 kPa/h was found between the fixation time of the prostate specimen and the stiffness of the tissue, which could affect the diagnostic power results.DWI and MRE may provide complementary information; in fact MRE performed better than ADC in distinguishing normal from cancerous tissue in some cases. Multi‐frequency (Gamma) analysis did not appear to improve the results. However, in light of the effect of tissue fixation, the clinical implication of our results may be inconclusive and more experiments are needed. Copyright © 2014 John Wiley & Sons, Ltd.


  • Prostate MR elastography with transperineal electromagnetic actuation and a fast fractionally encoded steady‐state gradient echo sequence

    by Ramin Sebastian Sahebjavaher, Samuel Frew, Artem Bylinskii, Leon ter Beek, Philippe Garteiser, Mohammad Honarvar, Ralph Sinkus, Septimiu Salcudean

    Our aim is to develop a clinically viable, fast‐acquisition, prostate MR elastography (MRE) system with transperineal excitation. We developed a new actively shielded electromagnetic transducer, designed to enable quick deployment and positioning within the scanner. The shielding of the transducer was optimized using simulations. We also employed a new rapid pulse sequence that encodes the three‐dimensional displacement field in the prostate gland using a fractionally encoded steady‐state gradient echo sequence, thereby shortening the acquisition time to a clinically acceptable 8–10 min. The methods were tested in two phantoms and seven human subjects (six volunteers and one patient with prostate cancer). The MRE acquisition time for 24 slices, with an isotropic resolution of 2 mm and eight phase offsets, was 8 min, and the total scan, including positioning and set‐up, was performed in 15–20 min. The phantom study demonstrated that the transducer does not interfere with the acquisition process and that it generates displacement amplitudes that exceed 100 µm even at frequencies as high as 300 Hz. In the in vivo human study, average wave amplitudes of 30 µm (46 µm at the apex) were routinely achieved within the prostate gland at 70 Hz. No pain or discomfort was reported. Results in a single patient suggest that MRE can identify cancer tumors, although this result is preliminary. The proposed methods allow the integration of prostate MRE with other multiparametric MRI methods. The results of this study clearly motivate the clinical evaluation of transperineal MRE in patients. Copyright © 2014 John Wiley & Sons, Ltd.


  • Transperineal prostate MR elastography: Initial in vivo results

    by Ramin S. Sahebjavaher, Ali Baghani, Mohammad Honarvar, Ralph Sinkus, Septimiu E. Salcudean

    This article presents a new approach to magnetic resonance elastography of the prostate using transperineal mechanical excitation. This approach is validated using a prostate elasticity phantom and in vivo studies of healthy volunteers. It is demonstrated that the transperineal approach can generate shear wave amplitudes on the order of 6–30 μm in the mid‐gland region. The driver was implemented using an electromagnetic actuator with a hydraulic transmission system. The magnetic resonance elastography acquisition time has been reduced significantly by using a “second harmonic” approach. Displacement fields are processed using the established three‐dimensional local frequency estimation algorithm. The three‐dimensional curl‐based direct inversion was used to calculate the local wavelength. The traveling wave expansion algorithm was used to reconstruct the wave damping image for one case. Using the proposed method, it was possible to resolve lesions of 0.5 cc in the phantom study. Repeatability experiments were performed and analyzed. The results from this study indicate that transperineal magnetic resonance elastography—without an endorectal coil—is a suitable candidate for a patient study involving multiparametric magnetic resonance imaging of prostate cancer, where magnetic resonance elastography may provide additional information for improved diagnosis and image‐based surveillance. Magn Reson Med, 2013.


  • Permanent magnet desktop magnetic resonance imaging system with microfabricated multiturn gradient coils for microflow imaging in capillary tubes

    by Ramin S. Sahebjavaher, Konrad Walus, Boris Stoeber

    A prototype for a desktop high-resolution magnetic resonance imaging (MRI) velocimetry instrument to characterize flow fields in a capillary tube is demonstrated. This inexpensive compact system is achieved with a 0.6 T permanent magnetic configuration (Larmor frequency of 25 MHz) and temperature compensation using off-the-shelf NdFeB permanent magnets. A triaxial gradient module with microfabricated copper coils using a lithographic fabrication process has been developed. This gradient module is capable of generating fast-switching gradients (<100 μs) with amplitudes up to 1.7 T/m using custom made current amplifiers, and was optimized for microflow imaging. The radio frequency probe is integrated with the gradient module and is driven by custom electronics. A two-dimensional (2D) cross-sectional static image of the inside of a capillary tube with an inner diameter of 1.67 mm is acquired at an in-plane spatial resolution of better than 40 μm. Time-of-flight flow measurements were also obtained using this MRI system to measure the velocity profile of water flowing at average velocities of above 50 mm/s. The flow profile for slower flow velocities was obtained using phase-encoded techniques, which provides quantitative velocity information in 2D.