Chikkakuntappa Ranganathaiah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chikkakuntappa Ranganathaiah has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Gangasandra N. Kumaraswamy
Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006, India
5 shared publications J. M. Raj
Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006, India
4 shared publicationsM. V. Deepa Urs
Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore, India
4 shared publicationsH. B. Ravikumar
Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore – 570006, India
3 shared publicationsSiddaramaiah
Sri Jayachamarajendra College of Engineering
3 shared publicationsJ.M. Raj
Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore-570006, India
2 shared publications
Latest Publications
- 11 January 2024
- Published by Wiley in Polymer Engineering & Science
- Vol. 64 (3) , 1365-1377
Gamma radiation impact on dielectrics and RH sensitivity of nylon–carbon–GNP–epoxy composites
Composites of carbon–graphene nanoplatelets (GNP) epoxy with nylon‐66 interleaving were fabricated and investigated to understand the impact of γ‐irradiation on their dielectrics and relative humidity (RH) sensitivity by capacitance and water absorption measurements. The moisture sensitivity was investigated by measuring memory effect (hysteresis) and response time of the capacitance. Composites were γ‐irradiated at doses of 1000 and 3000 kGy and studied by the same set of measurements. X‐ray diffraction analysis, Fourier transform infrared spectroscopy, and scanning electron microscopy were used to understand the impact of γ‐irradiation on the morphology and surface roughness of the composites. Results of these measurements suggest that 3000‐kGy dose γ‐irradiation produces good chain scission and cross‐linking, resulting in reduced water absorption and a 360% increase in capacitance values. The sensitivity of capacitance for 3000‐kGy γ‐irradiated composite was found to be highest at 40 pF/%RH, and hysteresis was 1.8% RH and not observed in non‐irradiated composites. Based on these observations, it seems that 3000‐kGy γ‐irradiated composite could be a potential candidate for moisture content diagnostics during condition monitoring of the carbon–epoxy structures in several industrial applications and needs to be further investigated.Highlights: Composites of carbon–GNP epoxy with nylon‐66 interleaving were γ‐irradiated. 3000‐kGy dose γ‐irradiated composites exhibit 360% increase in capacitance. Sensitivity and hysteresis were higher than those of 1000‐kGy and non‐irradiated samples. Good chain scission and cross‐linking resulted in reduced water absorption.
- 11 January 2024
- Published by Wiley in Polymer Engineering & Science
- Vol. 64 (3) , 1365-1377
Gamma radiation impact on dielectrics and RH sensitivity of nylon–carbon–GNP–epoxy composites
Composites of carbon–graphene nanoplatelets (GNP) epoxy with nylon‐66 interleaving were fabricated and investigated to understand the impact of γ‐irradiation on their dielectrics and relative humidity (RH) sensitivity by capacitance and water absorption measurements. The moisture sensitivity was investigated by measuring memory effect (hysteresis) and response time of the capacitance. Composites were γ‐irradiated at doses of 1000 and 3000 kGy and studied by the same set of measurements. X‐ray diffraction analysis, Fourier transform infrared spectroscopy, and scanning electron microscopy were used to understand the impact of γ‐irradiation on the morphology and surface roughness of the composites. Results of these measurements suggest that 3000‐kGy dose γ‐irradiation produces good chain scission and cross‐linking, resulting in reduced water absorption and a 360% increase in capacitance values. The sensitivity of capacitance for 3000‐kGy γ‐irradiated composite was found to be highest at 40 pF/%RH, and hysteresis was 1.8% RH and not observed in non‐irradiated composites. Based on these observations, it seems that 3000‐kGy γ‐irradiated composite could be a potential candidate for moisture content diagnostics during condition monitoring of the carbon–epoxy structures in several industrial applications and needs to be further investigated.Highlights: Composites of carbon–GNP epoxy with nylon‐66 interleaving were γ‐irradiated. 3000‐kGy dose γ‐irradiated composites exhibit 360% increase in capacitance. Sensitivity and hysteresis were higher than those of 1000‐kGy and non‐irradiated samples. Good chain scission and cross‐linking resulted in reduced water absorption.
- Open Access
- 10 June 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 443, 012047
Positron annihilation lifetime study of interfaces in ternary polymer blends
- 10 June 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 443, 012047
Open AccessPositron annihilation lifetime study of interfaces in ternary polymer blends
- 30 May 2013
- Published by Wiley in Polymer Engineering & Science
- Vol. 54 (3) , 667-674
Synthesis and characterization of methacrylic acid‐based molecular imprinted polymers by positron lifetime spectroscopy
Three molecular imprinted polymers (MIPs) were prepared with different amounts of crosslinker (ethylene glycol dimethacrylate) in methacrylic acid functional monomer. Positron lifetime spectroscopy has been used to study the variation in free volume cavities (nanosize pores) in these MIPs of different monomer‐crosslinker ratio. The changes in free volume cavities after the template molecule 4‐chlorophenol extracted from the polymer matrix were measured. The results indicate that the optimum monomer‐crosslinker ratio for this MIP is 1:5. The free volume distribution derived from CONTIN program further reveals the presence and absence of template molecules in the system. The Fourier transform infrared spectra results have been used to compliment this through the absence of stretching frequencies at 648 cm−1 and 825 cm−1 of CCl suggesting the successful extraction of the template from the MIPs. Scanning electron microscope (SEM) scans indicate the grains are of heterogeneous shape and size in agreement with earlier studies. POLYM. ENG. SCI., 54:667–674, 2014. © 2013 Society of Plastics Engineers
- 30 May 2013
- Published by Wiley in Polymer Engineering & Science
- Vol. 54 (3) , 667-674
Synthesis and characterization of methacrylic acid‐based molecular imprinted polymers by positron lifetime spectroscopy
Three molecular imprinted polymers (MIPs) were prepared with different amounts of crosslinker (ethylene glycol dimethacrylate) in methacrylic acid functional monomer. Positron lifetime spectroscopy has been used to study the variation in free volume cavities (nanosize pores) in these MIPs of different monomer‐crosslinker ratio. The changes in free volume cavities after the template molecule 4‐chlorophenol extracted from the polymer matrix were measured. The results indicate that the optimum monomer‐crosslinker ratio for this MIP is 1:5. The free volume distribution derived from CONTIN program further reveals the presence and absence of template molecules in the system. The Fourier transform infrared spectra results have been used to compliment this through the absence of stretching frequencies at 648 cm−1 and 825 cm−1 of CCl suggesting the successful extraction of the template from the MIPs. Scanning electron microscope (SEM) scans indicate the grains are of heterogeneous shape and size in agreement with earlier studies. POLYM. ENG. SCI., 54:667–674, 2014. © 2013 Society of Plastics Engineers
- 4 April 2013
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 130 (2) , 793-800
Thermally induced microstructural changes and its influence on electrical conductivity of a polymer‐based bakelite RPC detector material: A positron lifetime study
Annealing studies have been carried out to understand the temperature induced microstructural changes in Bakelite (P‐120 NEMA LI‐1989 Grade XXX) Resistive Plate Chamber (RPC) detector material using Positron annihilation lifetime spectroscopy (PALS), Fourier transform infrared spectroscopy (FTIR), and XRD. The variation of positron lifetime parameters viz., ortho‐Positronium lifetime (τ3) and free volume size (Vf) increases marginally above glass transition temperatureTgas a result of structural changes due to segmental mobility. The drastic increase of free volume parameters above 240°C attributed to the reduction in strength of C—H bond of the aliphatic bridges and cleavage of methylene bridges of the polymer network, which is supported by the FTIR results. The XRD results show the reduction in crystallinity and average crystallite size of Bakelite on annealing correlates well with the free volume and electrical conductivity. The temperature induced electrical conductivity and activation energy is also correlated with the positron lifetime parameters. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 130: 793‐800, 2013
- 4 April 2013
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 130 (2) , 793-800
Thermally induced microstructural changes and its influence on electrical conductivity of a polymer‐based bakelite RPC detector material: A positron lifetime study
Annealing studies have been carried out to understand the temperature induced microstructural changes in Bakelite (P‐120 NEMA LI‐1989 Grade XXX) Resistive Plate Chamber (RPC) detector material using Positron annihilation lifetime spectroscopy (PALS), Fourier transform infrared spectroscopy (FTIR), and XRD. The variation of positron lifetime parameters viz., ortho‐Positronium lifetime (τ3) and free volume size (Vf) increases marginally above glass transition temperatureTgas a result of structural changes due to segmental mobility. The drastic increase of free volume parameters above 240°C attributed to the reduction in strength of C—H bond of the aliphatic bridges and cleavage of methylene bridges of the polymer network, which is supported by the FTIR results. The XRD results show the reduction in crystallinity and average crystallite size of Bakelite on annealing correlates well with the free volume and electrical conductivity. The temperature induced electrical conductivity and activation energy is also correlated with the positron lifetime parameters. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 130: 793‐800, 2013
- 4 May 2012
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 127 (1) , 190-199
A new insight into interface widths in binary polymer blends based on ortho‐positronium lifetime studies
The interface widths in two immiscible polymer blend (Poly vinyl chloride (PVC)/Polystyrene (PS)) and PVC/Ethylene Vinyl Acetate (EVA) are determined experimentally using hydrodynamic interaction approach through free volume measurement by positron annihilation lifetime spectroscopy. For comparison, the same study is performed in a miscible blend (Styrene Acrylonitrile (SAN)/Poly Methyl Methacrylate (PMMA)). The interfacial width (Δl) is evaluated from the hydrodynamic interaction (α) based on Kirkwood–Risemann theory and friction coefficient from Stokes equation. Friction at the interface of a binary blend evidences how close the surfaces of the polymer chains come or stay apart which in turn depends on the type of force/interaction at the interface. In this work, we define interface width from a different perspective of Flory–Huggins interaction approach. Measured composition dependent interface widths in the three blends studied clearly demonstrate the sensitivity of the present method. In miscible blend, high friction at the interface results in stronger hydrodynamic interaction and hence smaller interface widths (0.36–1.97 Å), whereas weak or no interaction in immiscible blends produce wider widths (2.81–25.0 Å). © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013
- 4 May 2012
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 127 (1) , 190-199
A new insight into interface widths in binary polymer blends based on ortho‐positronium lifetime studies
The interface widths in two immiscible polymer blend (Poly vinyl chloride (PVC)/Polystyrene (PS)) and PVC/Ethylene Vinyl Acetate (EVA) are determined experimentally using hydrodynamic interaction approach through free volume measurement by positron annihilation lifetime spectroscopy. For comparison, the same study is performed in a miscible blend (Styrene Acrylonitrile (SAN)/Poly Methyl Methacrylate (PMMA)). The interfacial width (Δl) is evaluated from the hydrodynamic interaction (α) based on Kirkwood–Risemann theory and friction coefficient from Stokes equation. Friction at the interface of a binary blend evidences how close the surfaces of the polymer chains come or stay apart which in turn depends on the type of force/interaction at the interface. In this work, we define interface width from a different perspective of Flory–Huggins interaction approach. Measured composition dependent interface widths in the three blends studied clearly demonstrate the sensitivity of the present method. In miscible blend, high friction at the interface results in stronger hydrodynamic interaction and hence smaller interface widths (0.36–1.97 Å), whereas weak or no interaction in immiscible blends produce wider widths (2.81–25.0 Å). © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013
- 11 July 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1349 (1) , 228
Free Volume Size Distribution in Some Natural Polymers
Positron lifetime technique was used to determine the size distribution of free volume holes in some natural polymers–animal hair, feather, cotton and silk. The effect of fiber swelling on the nature of size distribution was also monitored. The obtained positron lifetime spectra were analyzed by using the computer program CONTIN (PALS‐2). Significant differences in the size distribution were observed for these biological polymers (and even among the different animal hair types), possibly due to the structural differences, which have not been investigated hitherto.
- 11 July 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1349 (1) , 228
Free Volume Size Distribution in Some Natural Polymers
Positron lifetime technique was used to determine the size distribution of free volume holes in some natural polymers–animal hair, feather, cotton and silk. The effect of fiber swelling on the nature of size distribution was also monitored. The obtained positron lifetime spectra were analyzed by using the computer program CONTIN (PALS‐2). Significant differences in the size distribution were observed for these biological polymers (and even among the different animal hair types), possibly due to the structural differences, which have not been investigated hitherto.
- 1 July 2011
- Published by Walter de Gruyter GmbH in Journal of Polymer Engineering
- Vol. 31 (2-3)
Mechanical and microstructural properties of polystyrene based composites: positron lifetime spectroscopic and DSC studies
Polystyrene (PS) based composites respectively with cenosphere (CS) and calcium aluminosilicate (CAS) as fillers were studied using the positron lifetime technique to reveal the correlation between free volume, a microstructural property, and mechanical properties of the composites (tensile strength and tensile modulus). The thermal stability of the composites was determined using differential scanning calorimetry. The results showed that addition of CAS filler lead to a significant improvement in the mechanical properties of the composite, whereas addition of CS resulted in improvement in tensile modulus only. Both PS/CAS and PS/CS composites showed enhancement in thermal stability compared with that of the pure PS matrix. The positron results showed that the average free volume size for the PS/CAS composite (at 40 phr CAS) was reduced significantly compared with that of the pure PS. These results are understood in terms of the influence of silica content, filler-matrix interaction, and particle size.
- 1 July 2011
- Published by Walter de Gruyter GmbH in Journal of Polymer Engineering
- Vol. 31 (2-3)
Mechanical and microstructural properties of polystyrene based composites: positron lifetime spectroscopic and DSC studies
Polystyrene (PS) based composites respectively with cenosphere (CS) and calcium aluminosilicate (CAS) as fillers were studied using the positron lifetime technique to reveal the correlation between free volume, a microstructural property, and mechanical properties of the composites (tensile strength and tensile modulus). The thermal stability of the composites was determined using differential scanning calorimetry. The results showed that addition of CAS filler lead to a significant improvement in the mechanical properties of the composite, whereas addition of CS resulted in improvement in tensile modulus only. Both PS/CAS and PS/CS composites showed enhancement in thermal stability compared with that of the pure PS matrix. The positron results showed that the average free volume size for the PS/CAS composite (at 40 phr CAS) was reduced significantly compared with that of the pure PS. These results are understood in terms of the influence of silica content, filler-matrix interaction, and particle size.
- 29 March 2011
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 121 (5) , 2752-2760
Characterization of nanosilica‐filled epoxy composites for electrical and insulation applications
We report in this article the results of nanosilica (SiO2)‐filled epoxy composites with different loadings and their electrical, thermal, mechanical, and free‐volume properties characterized with different techniques. The morphological features were studied by transmission electron microscopy, and differential scanning calorimetry was used to investigate the glass‐transition temperature (Tg) of the nanocomposites. The properties of the nanocomposites showed that the electrical resistivity (ρ), ultimate tensile strength, and hardness of the composites increased with SiO2weight fraction up to 10 wt % and decreased thereafter; this suggested that the beneficial properties occurred up to this weight fraction. The temperature and seawater aging had a negative influence on ρ; that is, ρ decreased with increases in the temperature and aging. The free‐volume changes (microstructural) in the composite systems correlated with seawater aging but did not correlate so well with the mechanical properties. © 2011 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2011
- 29 March 2011
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 121 (5) , 2752-2760
Characterization of nanosilica‐filled epoxy composites for electrical and insulation applications
We report in this article the results of nanosilica (SiO2)‐filled epoxy composites with different loadings and their electrical, thermal, mechanical, and free‐volume properties characterized with different techniques. The morphological features were studied by transmission electron microscopy, and differential scanning calorimetry was used to investigate the glass‐transition temperature (Tg) of the nanocomposites. The properties of the nanocomposites showed that the electrical resistivity (ρ), ultimate tensile strength, and hardness of the composites increased with SiO2weight fraction up to 10 wt % and decreased thereafter; this suggested that the beneficial properties occurred up to this weight fraction. The temperature and seawater aging had a negative influence on ρ; that is, ρ decreased with increases in the temperature and aging. The free‐volume changes (microstructural) in the composite systems correlated with seawater aging but did not correlate so well with the mechanical properties. © 2011 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2011
- 13 December 2010
- Published by Wiley in Polymer Composites
- Vol. 32 (1) , 139-146
Characterization of ACS modified epoxy resin composites with fly ash and cenospheres as fillers: Mechanical and microstructural properties
Composites of diglycidyl ether of bisphenol A resin modified with Amine Containing Silicone as matrix and fly ash and cenospheres as fillers have been examined for their mechanical and microstructural properties. The microstructural features of the composites in terms of free volume size and content, and its influence on the mechanical properties has been investigated. The results indicate that amine containing silicones works as a good coupling agent between the filler and the resin. Composites with 5 phr fly ash and 30 phr cenospheres showed improved thermal stability as indicated by the increased Tg of the composites, possibly because of increased SiOSi linkages. The tensile strength of cenospheres‐filled composites showed good improvement compared with that of the fly ash‐filled composites. Low density (0.6 g/cc) and higher silica content (60%) of cenospheres seems to be the reason for this observation, which is well corroborated by the free volume data. POLYM. COMPOS., 2011. © 2010 Society of Plastics Engineers
- 13 December 2010
- Published by Wiley in Polymer Composites
- Vol. 32 (1) , 139-146
Characterization of ACS modified epoxy resin composites with fly ash and cenospheres as fillers: Mechanical and microstructural properties
Composites of diglycidyl ether of bisphenol A resin modified with Amine Containing Silicone as matrix and fly ash and cenospheres as fillers have been examined for their mechanical and microstructural properties. The microstructural features of the composites in terms of free volume size and content, and its influence on the mechanical properties has been investigated. The results indicate that amine containing silicones works as a good coupling agent between the filler and the resin. Composites with 5 phr fly ash and 30 phr cenospheres showed improved thermal stability as indicated by the increased Tg of the composites, possibly because of increased SiOSi linkages. The tensile strength of cenospheres‐filled composites showed good improvement compared with that of the fly ash‐filled composites. Low density (0.6 g/cc) and higher silica content (60%) of cenospheres seems to be the reason for this observation, which is well corroborated by the free volume data. POLYM. COMPOS., 2011. © 2010 Society of Plastics Engineers