IRIan Rollo

Ian Rollo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ian Rollo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Effect of Carbohydrate-Electrolyte Beverage Drinking Strategy on 10-Mile Running Performance

    by Ian Rollo, Lewis James, Louise Croft, Clyde Williams

    The purpose of the current study was to investigate the influence of ingesting a carbohydrate-electrolyte (CHO-E) beverage ad libitum or as a prescribed volume on 10-mile run performance and gastrointestinal (GI) discomfort. Nine male recreational runners completed the 10-mile run under the following 3 conditions: no drinking (ND; 0 ml, 0 g CHO), ad libitum drinking (AD; 315 ± 123 ml, 19 ± 7 g CHO), and prescribed drinking (PD; 1,055 ± 90 ml, 64 ± 5 g CHO). During the AD and PD trials, drinks were provided on completion of Miles 2, 4, 6, and 8. Running performance, speed (km/hr), and 10-mile run time were assessed using a global positioning satellite system. The runners’ ratings of perceived exertion and GI comfort were recorded on completion of each lap of the 10-mile run. There was a significant difference (p < .10) in performance times for the 10-mile race for the ND, AD, and PD trials, which were 72:05 ± 3:36, 71:14 ± 3:35, and 72:12 ± 3.53 min:s, respectively (p = .094). Ratings of GI comfort were reduced during the PD trial in comparison with both AD and ND trials. In conclusion, runners unaccustomed to habitually drinking CHO-E beverages during training improved their 10-mile race performance with AD drinking a CHO-E beverage, in comparison with drinking a prescribed volume of the same beverage or no drinking.


  • Effect of Mouth-Rinsing Carbohydrate Solutions on Endurance Performance

    by Ian Rollo, Clyde Williams

    Ingesting carbohydrate-electrolyte solutions during exercise has been reported to benefit self-paced time-trial performance. The mechanism responsible for this ergogenic effect is unclear. For...


  • Influence of ingesting a carbohydrate-electrolyte solution before and during a 1-hour run in fed endurance-trained runners

    by Ian Rollo, Clyde Williams

    The aim of this study was to determine whether the ingestion of a carbohydrate-electrolyte solution would improve 1-h running performance in runners who had consumed a meal 3 h before exercise. Ten endurance-trained male runners completed two trials that required them to run as far as possible in 1 h on an automated treadmill that allowed changes in running speed without manual input. Following the consumption of the pre-exercise meal, which provided 2.5 g carbohydrate per kilogram body mass (BM), runners ingested either a 6.4% carbohydrate-electrolyte solution or placebo solution (i.e. 8 ml · kg BM−1) 30 min before and 2 ml · kg BM−1 at 15-min intervals throughout the 1-h run. There were no differences in total distance covered (placebo: 13,680 m, s = 1525; carbohydrate: 13,589 m, s = 1635) (P > 0.05). Blood glucose and lactate concentration, respiratory exchange ratio, and carbohydrate oxidation during exercise were not different between trials (P > 0.05). There were also no differences in ratings of perceived exertion, felt arousal or pleasure–displeasure between trials (P > 0.05). In conclusion, the ingestion of a 6.4% carbohydrate-electrolyte solution did not improve 1-h running performance when a high carbohydrate meal was consumed 3 h before exercise.


  • Repeatability of scores on a novel test of endurance running performance

    by Ian Rollo, Clyde Williams, Alan Nevill

    The aim of the present study was to determine the repeatability of a running endurance test using an automated treadmill system that requires no manual input to control running speed. On three separate occasions, 7 days apart, 10 experienced male endurance-trained runners (mean age 32 years, s = 10; [Vdot]O2peak 61 ml · kg−1 · min−1, s = 7) completed a treadmill time trial, in which they were instructed to run as far as possible in 60 min. The treadmill was instrumented with an ultrasonic feedback-controlled radar modulator that spontaneously regulated treadmill belt speed corresponding to the changing running speed of each runner. Estimated running intensity was 70%[Vdot]O2peak (s = 11) and the distance covered 13.5 km (s = 2), with no difference in mean performances between trials. The coefficient of variation, estimated using analysis of variance, with participant and trial as main effects, was 1.4%. In summary, the use of an automated treadmill system improved the repeatability of a 60-min treadmill time trial compared with time trials in which speed is controlled manually. The present protocol is a reliable method of assessing endurance performance in endurance-trained runners.