CPCharles Peebles

Charles Peebles

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Charles Peebles has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of optimisation to contemporary HFrEF medical therapy with sacubitril/valsartan (Entresto) and dapaglifloziN on left Ventricular reverse remodelling as demonstrated by cardiac magnetic resonance (CMR) Imaging: the ENVI study

    by Alice Zheng, Robert Adam, Charles Peebles, Stephen Harden, James Shambrook, Ausami Abbas, Katharine Vedwan, Georgina Adam, Paul Haydock, Peter Cowburn, et al.

    Introduction: Heart failure with reduced ejection fraction (HFrEF) guidelines recommend ‘four pillars’ of medical therapy and device therapy if left ventricular ejection fraction (LVEF) remains ≤35% after 3 months optimum medical therapy. We conducted the first study to examine the effects of optimisation to contemporary medical therapy on cardiac reverse remodelling, as demonstrated by cardiac magnetic resonance imaging (CMR). We hypothesised a proportion of patients would undergo beneficial remodelling and LVEF improvement above the threshold for complex device prescription after 6 months. Methods: HFrEF patients with symptomatic LVEF≤35% despite ACE inhibitor/beta blocker/mineralocorticoid receptor antagonist therapy, and qualified for sacubitril/valsartan switchover were recruited to this single centre prospective study. CMR was performed at baseline and at follow-up. Clinical, volumetric and outcome data were collected and compared. Results: Between June 2021 and August 2022, 49 patients were recruited. The majority (80%) were male, mean age 63±14 years. 35 (71%) had non-ischaemic cardiomyopathy. 2 (4%) patients died and 47 were followed up for a median of 7.4 months. There were no heart failure hospitalisations. Significant reductions were seen in median indexed left atrial volume: 54 mL/m2 (41–72) to 39 mL/m2 (30–60) (p2 (74–125) to 76 mL/m2 (58–102) (p2 (50–92) to 43 mL/m2 (27–58) (p2 to 62±13 g/m2 (p<0.001). Median LVEF increased by 12 points from 31% to 43% (p35%. 13 (27%) patients improved to LVEF≥50%. Median N-terminal pro B type natriuretic peptide (NTproBNP) reduced from 883 ng/L (293–2043) to 429 ng/L (171–1421) (p<0.001). Conclusions: Optimisation to contemporary HFrEF medical therapy results in beneficial cardiac reverse remodelling and significant improvements in LVEF and NTproBNP at 6 months as demonstrated by CMR. 59% of our cohort no longer met complex device indications. Guidelines suggest re-assessment of LVEF at 3 months, but our data suggests a longer period is required. Trial registration number: NCT05348226.


  • Dynamic contrast-enhanced CT compared with positron emission tomography CT to characterise solitary pulmonary nodules: the SPUtNIk diagnostic accuracy study and economic modelling

    by Fiona J Gilbert, Scott Harris, Kenneth A Miles, Jonathan R Weir-McCall, Nagmi R Qureshi, Robert C Rintoul, Sabina Dizdarevic, Lucy Pike, Donald Sinclair, Andrew Shah, et al.

    Background: Current pathways recommend positron emission tomography–computerised tomography for the characterisation of solitary pulmonary nodules. Dynamic contrast-enhanced computerised tomography may be a more cost-effective approach. Objectives: To determine the diagnostic performances of dynamic contrast-enhanced computerised tomography and positron emission tomography–computerised tomography in the NHS for solitary pulmonary nodules. Systematic reviews and a health economic evaluation contributed to the decision-analytic modelling to assess the likely costs and health outcomes resulting from incorporation of dynamic contrast-enhanced computerised tomography into management strategies. Design: Multicentre comparative accuracy trial. Setting: Secondary or tertiary outpatient settings at 16 hospitals in the UK. Participants: Participants with solitary pulmonary nodules of ≥ 8 mm and of ≤ 30 mm in size with no malignancy in the previous 2 years were included. Interventions: Baseline positron emission tomography–computerised tomography and dynamic contrast-enhanced computer tomography with 2 years’ follow-up. Main outcome measures: Primary outcome measures were sensitivity, specificity and diagnostic accuracy for positron emission tomography–computerised tomography and dynamic contrast-enhanced computerised tomography. Incremental cost-effectiveness ratios compared management strategies that used dynamic contrast-enhanced computerised tomography with management strategies that did not use dynamic contrast-enhanced computerised tomography. Results: A total of 380 patients were recruited (median age 69 years). Of 312 patients with matched dynamic contrast-enhanced computer tomography and positron emission tomography–computerised tomography examinations, 191 (61%) were cancer patients. The sensitivity, specificity and diagnostic accuracy for positron emission tomography–computerised tomography and dynamic contrast-enhanced computer tomography were 72.8% (95% confidence interval 66.1% to 78.6%), 81.8% (95% confidence interval 74.0% to 87.7%), 76.3% (95% confidence interval 71.3% to 80.7%) and 95.3% (95% confidence interval 91.3% to 97.5%), 29.8% (95% confidence interval 22.3% to 38.4%) and 69.9% (95% confidence interval 64.6% to 74.7%), respectively. Exploratory modelling showed that maximum standardised uptake values had the best diagnostic accuracy, with an area under the curve of 0.87, which increased to 0.90 if combined with dynamic contrast-enhanced computerised tomography peak enhancement. The economic analysis showed that, over 24 months, dynamic contrast-enhanced computerised tomography was less costly (£3305, 95% confidence interval £2952 to £3746) than positron emission tomography–computerised tomography (£4013, 95% confidence interval £3673 to £4498) or a strategy combining the two tests (£4058, 95% confidence interval £3702 to £4547). Positron emission tomography–computerised tomography led to more patients with malignant nodules being correctly managed, 0.44 on average (95% confidence interval 0.39 to 0.49), compared with 0.40 (95% confidence interval 0.35 to 0.45); using both tests further increased this (0.47, 95% confidence interval 0.42 to 0.51). Limitations: The high prevalence of malignancy in nodules observed in this trial, compared with that observed in nodules identified within screening programmes, limits the generalisation of the current results to nodules identified by screening. Conclusions: Findings from this research indicate that positron emission tomography–computerised tomography is more accurate than dynamic contrast-enhanced computerised tomography for the characterisation of solitary pulmonary nodules. A combination of maximum standardised uptake value and peak enhancement had the highest accuracy with a small increase in costs. Findings from this research also indicate that a combined positron emission tomography–dynamic contrast-enhanced computerised tomography approach with a slightly higher willingness to pay to avoid missing small cancers or to avoid a ‘watch and wait’ policy may be an approach to consider. Future work: Integration of the dynamic contrast-enhanced component into the positron emission tomography–computerised tomography examination and the feasibility of dynamic contrast-enhanced computerised tomography at lung screening for the characterisation of solitary pulmonary nodules should be explored, together with a lower radiation dose protocol. Study registration: This study is registered as PROSPERO CRD42018112215 and CRD42019124299, and the trial is registered as ISRCTN30784948 and ClinicalTrials.gov NCT02013063. Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 26, No. 17. See the NIHR Journals Library website for further project information.


  • Haemoptysis with a Danish connection

    by Abdullahi Omar Mohamud, Dominic Fudge, Ben G Marshall, Charles Peebles

    Her chest X-ray revealed right upper zone consolidation. The only blood abnormalities were a C-reactive protein (CRP) of 17 and white blood cell count of 20 x 109/L . She was diagnosed with a community acquired pneumonia and discharged with a course of amoxicillin. A follow up chest X-ray was arranged.

  • Open Access

    Influence of Maternal Lifestyle and Diet on Perinatal DNA Methylation Signatures Associated With Childhood Arterial Stiffness at 8 to 9 Years

    by Robert Murray, Negusse Kitaba, Elie Antoun, Philip Titcombe, Sheila Barton, Cyrus Cooper, Hazel M. Inskip, Graham C. Burdge, Pamela A. Mahon, John Deanfield, et al.

    Increases in aortic pulse wave velocity, a measure of arterial stiffness, can lead to elevated systolic blood pressure and increased cardiac afterload in adulthood. These changes are detectable in childhood and potentially originate in utero, where an adverse early life environment can alter DNA methylation patterns detectable at birth. Here, analysis of epigenome-wide methylation patterns using umbilical cord blood DNA from 470 participants in the Southampton’s Women’s Survey identified differential methylation patterns associated with systolic blood pressure, pulse pressure, arterial distensibility, and descending aorta pulse wave velocity measured by magnetic resonance imaging at 8 to 9 years. Perinatal methylation levels at 16 CpG loci were associated with descending aorta pulse wave velocity, with identified CpG sites enriched in pathways involved in DNA repair ( P =9.03×10 −11 ). The most significant association was with cg20793626 methylation (within protein phosphatase, Mg2+/Mn2+ dependent 1D; β=−0.05 m/s/1% methylation change, [95% CI, −0.09 to −0.02]). Genetic variation was also examined but had a minor influence on these observations. Eight pulse wave velocity-linked dmCpGs were associated with prenatal modifiable risk factors, with cg08509237 methylation (within palmitoyl-protein thioesterase-2) associated with maternal oily fish consumption in early and late pregnancy. Lower oily fish consumption in early pregnancy modified the relationship between methylation and pulse wave velocity, with lower consumption strengthening the association between cg08509237 methylation and increased pulse wave velocity. In conclusion, measurement of perinatal DNA methylation signatures has utility in identifying infants who might benefit from preventive interventions to reduce risk of later cardiovascular disease, and modifiable maternal factors can reduce this risk in the child.


  • Comparison of MOLLI and ShMOLLI Regarding T1 Reactivity, and the Relationship of T1 Reactivity with Conventional Signs of Response During Adenosine Stress Perfusion CMR

    by Esin Gezmiş, Charles Peebles, Andrew Flett, Ausami Abbas, Stephen Harden, James Shambrook

    Background: One of the most important techniques of cardiac magnetic resonance in assessment of coronary heart diseases is adenosine stress myocardial first-pass perfusion imaging. Using this imaging method, there should be an adequate response to the drug adenosine to make an accurate evaluation. The conventional signs of drug response are not always observed and are often subjective. Methods based on splenic perfusion might possess limitations as well. Therethre, T1 mapping presents as a novel, quantitative and reliable method. There are several studies analyzing this newly discovered property of different T1 mapping sequences. However most of these studies are enrolling only one of the techniques. Aims: To compare modified look-locker inversion recovery and shortened modified look-locker inversion recovery sequences in terms of T1 reactivity and to determine the relationship between T1 reactivity and conventional stress adequacy assessment methods in adenosine stress perfusion cardiac magnetic resonance. Study Design: A cross-sectional study using STARD reporting guideline. Methods: Thirty-tbur consecutive patients, who were referred for adenosine stress perfusion cardiac magnetic resonance with suspect of myocardial ischemia, were prospectively enrolled into the study. Four patients were disqualified, and thirty patients were included in the final analysis. Using both modified look-locker inversion recovery and shortened modified look-locker inversion recovery, midventricular short axis slices of T1 maps were acquired at rest and dining peak adenosine stress before gadolinium administration. Then, they were divided into six segments according to the 17-segment model proposed by the American Heart Association, and separate measurements were made from each segment. Mean rest and mean stress T1 values of remote, ischemic, and infarcted myocardium were calculated individually per subject. During adenosine administration. patients' heart rates and blood pressures are measured and recorded every one minute. Adenosine stress perfusion images were examined for the presence of splenic switch-off. Results: There was a significant difference between rest and stress T1 values of remote myocardium in both modified look-locker inversion recovery and shortened modified look-locker inversion recovery (p<0.001). In both modified look-locker inversion recovery and shortened modified look-locker inversion recovery there was no significant correlation between T1 reactivity and heart rates response (modified look-locker inversion recovery p=0.30, shortened modified look-locker inversion recovery p=0.10), blood pressures response (modified look-locker inversion recovery p=0.062, shortened modified look-locker inversion recovery p=0.078), splenic perfusion (modified look-locker inversion recovery p=0.35, shortened modified look-locker inversion recovery p=0.053). There was no statistically significant difference between modified look-locker inversion recovery and shortened modified look-locker inversion recovery regarding Ti reactivity of remote (p=0.330), ischemic (p=0.068), and infarcted (p=0.116) myocardium. Conclusion: T1 reactivity is independent of the other stress response signs and modified look-locker inversion recovery and shortened modified look-locker inversion recovery do not differ in terms of T1 reactivity.

  • Frequency and impact of incidental findings on computed tomography during work-up for transcatheter aortic valve implantation: single centre experience and review of the literature

    by Jonathan Hinton, Sam Gough, Hanad Ahmed, Lavinia Gabara, John Rawlins, Alison Calver, Benoy N Shah, Dhrubo Rakhit, James Shambrook, Stephen Harden, et al.

    Objective: To assess the frequency and impact of incidental findings (IF) on CT during work-up for transcatheter aortic valve intervention (TAVI). Methods: A consecutive cohort of patients referred for consideration of TAVI who underwent a CT scan between 2009 and 2018 were studied retrospectively. CT reports were reviewed for the presence of IFs and categorised based upon their clinical significance: (a) insignificant—findings that did not require specific treatment or follow-up; (b) intermediate—findings that did not impact on the decision-making process but required follow-up; (c) significant—findings that either required urgent investigation or meant that TAVI was clinically inappropriate. Results: A total of 652 patients were included, whose median age was 82 years. One or more insignificant IF was found in 95.6% of patients. Intermediate IFs were documented in 5.4%. 91 (14%) patients had at least one significant IF. These included possible malignancy in 67 (74%). The ultimate decision to offer aortic valve intervention was only changed by the presence of an IF in 3.5% of cases. Conclusion: Clinically significant IFs are detected in more than 1 in 10 of patients undergoing CT as part of a TAVI work-up, although just over half of these patients still receive aortic valve intervention. Advances in knowledge: This study is the largest UK cohort, which, when combined with a review of existing literature, provides a clear picture of the frequency and clinical impact of IFs found at CT for TAVI assessment.


  • Open Access

    Clot or not? An unusual case of false positive CTPA and an approach to diagnosis

    by Cheryl Main, Ausami Abbas, James S Shambrook, Charles Peebles, Stephen Harden

    The case involves a 69-year-old woman with severe, longstanding bronchiectasis secondary to childhood pertussis infection. She presented to hospital and was thought clinically to have a pulmonary embolus. A CT pulmonary angiogram was performed which was technically satisfactory. This revealed multiple, bilateral filling defects which were fairly convincing for pulmonary emboli. Further review of the CT revealed the extent of bronchiectasis but also a number of enlarged bronchial arteries supplying the diseased lung. The pulmonary arterial filling defects arose suspiciously close to the bronchial arteries and the possibility of bronchial artery to pulmonary artery anastomoses was considered. Could the admixture of highly contrast opacified pulmonary arterial blood with partially opacified systemic arterial blood cause the apparent filling defects? After further consideration, a second ECG gated CT angiogram was performed – this time in the systemic arterial phase but planned with two regions of interest si...


  • Pericardial Disease

    by Charles Peebles

  • Anatomy by CMR

    by Charles Peebles

  • The national evolution of cardiovascular CT practice: A UK NHS perspective

    by T.K. Mittal, E.D. Nicol, S.P. Harden, C.A. Roobottom, S.P. Padley, G. Roditi, C.R. Peebles, A. Taylor, M.C. Hamilton, G.J. Morgan-Hughes, et al.