Siamak Najarian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Siamak Najarian has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Javad Dargahi
Professor J. Dargahi, Mechanical &Industrial Engineering Dept., Concordia University, Montreal, Canada
9 shared publications- Farhad Tabatabai Ghomshe
Department of Ergonomics, Pediatric Neurorehabilitation Research Center, School of Rehabilitation Sciences, University of Social Welfare and Rehabilitation Sciences (USWR), Tehran, Iran
4 shared publications - Yaghoub Dabiri
Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
4 shared publications - Afsaneh Mojra
Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
3 shared publications - Javad Dargahi
Concordia University, Department of Mechanical and Industrial Engineering, 1455 de Maisonneuve Boulevard West, Montreal, Quebec, Canada H3G 1M8
3 shared publications - Ali Abouei Mehrizi2 shared publications
Latest Publications
- 7 July 2013
- Published byĀ WileyĀ inĀ The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol.Ā 9 Ā (3) , 371-378
Modeling and dynamic analysis of the wormālike part of an innovative robot applicable in colonoscopy
Background: The pathological conditions of the human colon may lead to cancer of the colon, which is one of the most common diseases of the gastrointestinal tract. Colonoscopy is the best diagnostic technique that can be used in colon cancer detection. However, many people do not accept this method due to the unpleasant experience, i.e. if it is not performed under sedation. As a result, changing the conventional colonoscopy into a robotic procedure seems beneficial.Methods: In this work, a semiāautonomous device capable of propelling itself along the flexible environment has been introduced. This robot is capable of advancing along intestinal turns such as the turn between the transverse and descending colon. Control of the robot's wormālike part has been investigated via dynamic simulations as well as computer programming.Results: The simulations resulted in workspace analysis of the robot. A prototype of the robot verified the performance of the computer program.Conclusion: The real model revealed the applicability of the method in controlling cableādriven wormālike mechanisms. Copyright Ā© 2013 John Wiley & Sons, Ltd.
- 7 July 2013
- Published byĀ WileyĀ inĀ The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol.Ā 9 Ā (3) , 371-378
Modeling and dynamic analysis of the wormālike part of an innovative robot applicable in colonoscopy
Background: The pathological conditions of the human colon may lead to cancer of the colon, which is one of the most common diseases of the gastrointestinal tract. Colonoscopy is the best diagnostic technique that can be used in colon cancer detection. However, many people do not accept this method due to the unpleasant experience, i.e. if it is not performed under sedation. As a result, changing the conventional colonoscopy into a robotic procedure seems beneficial.Methods: In this work, a semiāautonomous device capable of propelling itself along the flexible environment has been introduced. This robot is capable of advancing along intestinal turns such as the turn between the transverse and descending colon. Control of the robot's wormālike part has been investigated via dynamic simulations as well as computer programming.Results: The simulations resulted in workspace analysis of the robot. A prototype of the robot verified the performance of the computer program.Conclusion: The real model revealed the applicability of the method in controlling cableādriven wormālike mechanisms. Copyright Ā© 2013 John Wiley & Sons, Ltd.
- 4 February 2013
- Published byĀ ASME InternationalĀ inĀ Journal of Medical Devices
- Vol.Ā 7 Ā (1) , 015001
A New Surgical Device for Minimally Invasive āCore-Outā Excision of High Fistula-in-Ano
Core fistulectomy with endorectal advancement flap repair has been reported as a safe and effective technique for treatment of high fistula-in-ano. A number of rigid and flexible fistulectomy sets have already been fabricated pursuing the objectives of facilitating the procedure of this conservative surgical technique and reducing its risks of continence impairment. Two different methods (the method of scraping the granulation tissue of fistula and the method of separating and removing a thin layer from inside of tract) have been served in these sets for obliterating the abnormalities. In this work, with the aim of minimizing invasion to healthy tissue encircling the fistula, specially sphincter muscles, we designed and fabricated a new flexible fistulectomy device, which uses the second mentioned method. The new set separates an approximately 2.5-mm-thick layer from inside of the fistulous tract, by rotating a special tubular blade around its axis and moving the blade along the fistulous tract from external orifice toward the internal orifice. At the same time, the separated tissue may be removed from the fistulectomy lumen by rotating a special cannulated screw embedded coaxially inside the tubular blade. A flexible guidewire was used for identifying the tract path and guiding the device along it. We used the new set for excising 10 curved fistula models of approximately 16 cm length and 1.5 mm diameter, which were created in cubic pieces of fresh cow muscle as test specimens. After removing the device, each specimen was left with a smooth-walled lumen of approximately 9 mm diameter. The tubular blade works very well in separating a thin layer from inside of the fistula models and the cannulated screw is capable of easily removing the separated tissue. The removed tissue could be used as a sample of the whole tract for histopathological examinations. The screw and flexible guidewire lead the blade along the tract in a good manner and ensure circumferential separation of the fistula. With regard to the results of our tests, it is anticipated that the new set is an efficient instrument for easy, safe and fast core-out excision of high anal fistulas and is able to reduce the risk of injuries to healthy tissue encircling the fistulous tract.
- 4 February 2013
- Published byĀ ASME InternationalĀ inĀ Journal of Medical Devices
- Vol.Ā 7 Ā (1) , 015001
A New Surgical Device for Minimally Invasive āCore-Outā Excision of High Fistula-in-Ano
Core fistulectomy with endorectal advancement flap repair has been reported as a safe and effective technique for treatment of high fistula-in-ano. A number of rigid and flexible fistulectomy sets have already been fabricated pursuing the objectives of facilitating the procedure of this conservative surgical technique and reducing its risks of continence impairment. Two different methods (the method of scraping the granulation tissue of fistula and the method of separating and removing a thin layer from inside of tract) have been served in these sets for obliterating the abnormalities. In this work, with the aim of minimizing invasion to healthy tissue encircling the fistula, specially sphincter muscles, we designed and fabricated a new flexible fistulectomy device, which uses the second mentioned method. The new set separates an approximately 2.5-mm-thick layer from inside of the fistulous tract, by rotating a special tubular blade around its axis and moving the blade along the fistulous tract from external orifice toward the internal orifice. At the same time, the separated tissue may be removed from the fistulectomy lumen by rotating a special cannulated screw embedded coaxially inside the tubular blade. A flexible guidewire was used for identifying the tract path and guiding the device along it. We used the new set for excising 10 curved fistula models of approximately 16 cm length and 1.5 mm diameter, which were created in cubic pieces of fresh cow muscle as test specimens. After removing the device, each specimen was left with a smooth-walled lumen of approximately 9 mm diameter. The tubular blade works very well in separating a thin layer from inside of the fistula models and the cannulated screw is capable of easily removing the separated tissue. The removed tissue could be used as a sample of the whole tract for histopathological examinations. The screw and flexible guidewire lead the blade along the tract in a good manner and ensure circumferential separation of the fistula. With regard to the results of our tests, it is anticipated that the new set is an efficient instrument for easy, safe and fast core-out excision of high anal fistulas and is able to reduce the risk of injuries to healthy tissue encircling the fistulous tract.
- 1 January 2013
- Published byĀ SAGE PublicationsĀ inĀ Bio-Medical Materials and Engineering
- Vol.Ā 23 Ā (5) , 423-432
Artery cross-clamping during laparoscopic vascular surgeries; a computational tactile sensing approach
Artificial palpation is one of the most valuable achievements of artificial tactile sensing approach that can be used in various fields of medicine and more specifically in surgery. These techniques cause different surgical maneuvers to be done more
- 1 January 2013
- Published byĀ SAGE PublicationsĀ inĀ Bio-Medical Materials and Engineering
- Vol.Ā 23 Ā (5) , 423-432
Artery cross-clamping during laparoscopic vascular surgeries; a computational tactile sensing approach
Artificial palpation is one of the most valuable achievements of artificial tactile sensing approach that can be used in various fields of medicine and more specifically in surgery. These techniques cause different surgical maneuvers to be done more
- 1 January 2013
- Published byĀ ElsevierĀ inĀ Biocybernetics and Biomedical Engineering
- Vol.Ā 33 Ā (2) , 118-124
A powered prosthetic knee joint inspired from musculoskeletal system
- 1 January 2013
- Published byĀ ElsevierĀ inĀ Biocybernetics and Biomedical Engineering
- Vol.Ā 33 Ā (2) , 118-124
A powered prosthetic knee joint inspired from musculoskeletal system
- Open Access
- 1 April 2012
- Vol.Ā 44 Ā (1) , 41-46
Investigating Effective Parameters in Tactile Determination of Artery included in Soft Tissue by FEM
- 1 April 2012
- Vol.Ā 44 Ā (1) , 41-46
Open AccessInvestigating Effective Parameters in Tactile Determination of Artery included in Soft Tissue by FEM
- 10 November 2011
- Published byĀ Taylor & FrancisĀ inĀ Journal of Medical Engineering & Technology
- Vol.Ā 36 Ā (1) , 8-16
A novel tactile-guided detection and three-dimensional localization of clinically significant breast masses
This paper presents a novel robotic sensory system āRobo-Tac-BMIā, which manipulates an indentation probe for the detection and three-dimensional localization of an abnormal mass embedded in the breast tissue. The Robo-Tac-BMI is designed based on artificial tactile sensing technology which is a new non-invasive method for mimicking the surgeonās palpation quantitatively. The intelligent processor of the device provides an overall stiffness map of the scanned areas. The extracted stiffness parameters provide a decisive factor for certifying the mass existence. Results are validated by āgold standardā tests. Following the mass detection, its 3D localization is of essential importance in the treatment procedures. The planar 2D coordinate is readily available for all points on the tissue surface. Mass depth estimation is achieved by a comprehensive model utilizing the logistic regression algorithm and a Receiver Operating Characteristic (ROC) Curve for the highest accuracy. Statistical analysis is performed over 27 cases with 346 scanned areas.
- 10 November 2011
- Published byĀ Taylor & FrancisĀ inĀ Journal of Medical Engineering & Technology
- Vol.Ā 36 Ā (1) , 8-16
A novel tactile-guided detection and three-dimensional localization of clinically significant breast masses
This paper presents a novel robotic sensory system āRobo-Tac-BMIā, which manipulates an indentation probe for the detection and three-dimensional localization of an abnormal mass embedded in the breast tissue. The Robo-Tac-BMI is designed based on artificial tactile sensing technology which is a new non-invasive method for mimicking the surgeonās palpation quantitatively. The intelligent processor of the device provides an overall stiffness map of the scanned areas. The extracted stiffness parameters provide a decisive factor for certifying the mass existence. Results are validated by āgold standardā tests. Following the mass detection, its 3D localization is of essential importance in the treatment procedures. The planar 2D coordinate is readily available for all points on the tissue surface. Mass depth estimation is achieved by a comprehensive model utilizing the logistic regression algorithm and a Receiver Operating Characteristic (ROC) Curve for the highest accuracy. Statistical analysis is performed over 27 cases with 346 scanned areas.
- 16 May 2011
- Published byĀ Taylor & FrancisĀ inĀ Minimally Invasive Therapy & Allied Technologies
- Vol.Ā 21 Ā (3) , 210-221
A novel robotic tactile mass detector with application in clinical breast examination
This paper presents a novel tactile sensing robot designed to detect breast lesions with minimum invasiveness to the tissue while providing exact documentation to make therapeutic and surgical decisions. The robot named "Robotic Tactile Breast Mass Identifier (Robo-Tac-BMI) consists of an indentation probe controlled by a robotic system and a visualization interface to manipulate the end-effecter. Geometrical maps of the test points with related tension-relaxation curves are provided during clinical examinations. Utilizing the curves, three functional stiffness parameters are extracted locally for each test point. These parameters are employed to provide objective information to facilitate the surgeon's task in the diagnostic procedure. Computational analysis is proposed for a real breast tissue model to study the capability of artificial tactile sensing in the mass detection. Indications of the mass existence are determined and employed as the basis of the Robo-Tac-BMI design and construction. Clinical trials are executed by the Robo-Tac-BMI on 161 cases. The results show that the robot has the potential to provide tissue mechanical properties unlike the conventional screening modalities carried out either by the surgeon or the imaging techniques which are not quantitative and lack documentation. Sonography with and without mammography is chosen as the "gold standard" tests.
- 16 May 2011
- Published byĀ Taylor & FrancisĀ inĀ Minimally Invasive Therapy & Allied Technologies
- Vol.Ā 21 Ā (3) , 210-221
A novel robotic tactile mass detector with application in clinical breast examination
This paper presents a novel tactile sensing robot designed to detect breast lesions with minimum invasiveness to the tissue while providing exact documentation to make therapeutic and surgical decisions. The robot named "Robotic Tactile Breast Mass Identifier (Robo-Tac-BMI) consists of an indentation probe controlled by a robotic system and a visualization interface to manipulate the end-effecter. Geometrical maps of the test points with related tension-relaxation curves are provided during clinical examinations. Utilizing the curves, three functional stiffness parameters are extracted locally for each test point. These parameters are employed to provide objective information to facilitate the surgeon's task in the diagnostic procedure. Computational analysis is proposed for a real breast tissue model to study the capability of artificial tactile sensing in the mass detection. Indications of the mass existence are determined and employed as the basis of the Robo-Tac-BMI design and construction. Clinical trials are executed by the Robo-Tac-BMI on 161 cases. The results show that the robot has the potential to provide tissue mechanical properties unlike the conventional screening modalities carried out either by the surgeon or the imaging techniques which are not quantitative and lack documentation. Sonography with and without mammography is chosen as the "gold standard" tests.
- 2 May 2011
- Published byĀ WileyĀ inĀ The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol.Ā 7 Ā (3) , 282-292
A novel haptic robotic viscogram for characterizing the viscoelastic behaviour of breast tissue in clinical examinations
Background: This paper presents a novel tactile sensing robot designed to characterize the viscoelastic behaviour of breast tissue during clinical breast examination (CBE). The robot, named the ārobotic tactile breast mass identifierā (RoboāTacāBMI), mainly consists of an indentation probe controlled by a robotic system and a visualization interface to manipulate the endāeffector. Major high order mechanical parameters are extracted to characterize the viscoelastic behaviour of the tissue in order to certify mass detection and judge the mass type. By fusing the measurements over both breasts, the probe can generalize a mechanical image to visualize the viscoelastic distribution within the internal tissue. The viscoelastic properties provide additional and objective information to facilitate the surgeon's task in the decisionāmaking process.Methods: A new computational method is presented for characterizing mass existence in a real breast model. The effect of the strain rate on the mechanical properties is considered to study the viscoelastic behaviour of different mass types. A creative method is proposed to find the optimum strain rate for different mass positions and consistencies, which improves nodule detection. The computational results would be used as the basis for the design and setāup of the RoboāTacāBMI. Clinical tests with statistical analyses were performed on 161 cases, using the RoboāTacāBMI.Results: The results include analysis of two highāorder mechanical properties. RoboāTacāBMI's capability of nodule detection and differentiation between benign and malignant mass types are investigated. The results were validated by āgold standardā tests.Conclusion: The results show that RoboāTacāBMI has the potential to provide highāorder mechanical parameters, unlike the conventional screening modality carried out by the surgeon, which is not inclusive or quantitative and lacks effectiveness and documentation. The nodule detection ability of this device is confirmed statistically in clinical breast examinations. Differentiation between different mass types is reported as the preliminary result of RoboāTacāBMI utilization. Copyright Ā© 2011 John Wiley & Sons, Ltd.
- 2 May 2011
- Published byĀ WileyĀ inĀ The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol.Ā 7 Ā (3) , 282-292
A novel haptic robotic viscogram for characterizing the viscoelastic behaviour of breast tissue in clinical examinations
Background: This paper presents a novel tactile sensing robot designed to characterize the viscoelastic behaviour of breast tissue during clinical breast examination (CBE). The robot, named the ārobotic tactile breast mass identifierā (RoboāTacāBMI), mainly consists of an indentation probe controlled by a robotic system and a visualization interface to manipulate the endāeffector. Major high order mechanical parameters are extracted to characterize the viscoelastic behaviour of the tissue in order to certify mass detection and judge the mass type. By fusing the measurements over both breasts, the probe can generalize a mechanical image to visualize the viscoelastic distribution within the internal tissue. The viscoelastic properties provide additional and objective information to facilitate the surgeon's task in the decisionāmaking process.Methods: A new computational method is presented for characterizing mass existence in a real breast model. The effect of the strain rate on the mechanical properties is considered to study the viscoelastic behaviour of different mass types. A creative method is proposed to find the optimum strain rate for different mass positions and consistencies, which improves nodule detection. The computational results would be used as the basis for the design and setāup of the RoboāTacāBMI. Clinical tests with statistical analyses were performed on 161 cases, using the RoboāTacāBMI.Results: The results include analysis of two highāorder mechanical properties. RoboāTacāBMI's capability of nodule detection and differentiation between benign and malignant mass types are investigated. The results were validated by āgold standardā tests.Conclusion: The results show that RoboāTacāBMI has the potential to provide highāorder mechanical parameters, unlike the conventional screening modality carried out by the surgeon, which is not inclusive or quantitative and lacks effectiveness and documentation. The nodule detection ability of this device is confirmed statistically in clinical breast examinations. Differentiation between different mass types is reported as the preliminary result of RoboāTacāBMI utilization. Copyright Ā© 2011 John Wiley & Sons, Ltd.
- 30 November 2010
- Published byĀ Taylor & FrancisĀ inĀ Journal of Medical Engineering & Technology
- Vol.Ā 35 Ā (1) , 19-33
Advances in medical robotic systems with specific applications in surgeryāa review
Although robotics was started as a form of entertainment, it gradually became used in different branches of science. Medicine, particularly in the operating room, has been influenced significantly by this field. Robotic technologies have offered valuable enhancements to medical or surgical processes through improved precision, stability and dexterity. In this paper we review different robotics and computer-assisted systems developed with medical and surgical applications. We cover early and recently developed systems in different branches of surgery. In addition to the united operational systems, we provide a review of miniature robotic, diagnostic and sensory systems developed to assist or collaborate with a main operator system. At the end of the paper, a discussion is given with the aim of summarizing the proposed points and predicting the future of robotics in medicine.
- 30 November 2010
- Published byĀ Taylor & FrancisĀ inĀ Journal of Medical Engineering & Technology
- Vol.Ā 35 Ā (1) , 19-33
Advances in medical robotic systems with specific applications in surgeryāa review
Although robotics was started as a form of entertainment, it gradually became used in different branches of science. Medicine, particularly in the operating room, has been influenced significantly by this field. Robotic technologies have offered valuable enhancements to medical or surgical processes through improved precision, stability and dexterity. In this paper we review different robotics and computer-assisted systems developed with medical and surgical applications. We cover early and recently developed systems in different branches of surgery. In addition to the united operational systems, we provide a review of miniature robotic, diagnostic and sensory systems developed to assist or collaborate with a main operator system. At the end of the paper, a discussion is given with the aim of summarizing the proposed points and predicting the future of robotics in medicine.
- 30 September 2010
- Vol.Ā 56 Ā (3) , E92-7
Effects of mass and momentum of inertia alternation on individual muscle forces during swing phase of transtibial amputee gait.
A computer simulation was carried out to investigate the forces of lower extremity muscles in the swing phase of a transtibial amputee gait. With each muscle as an ideal force generator, the lower extremity was simulated as a two-degrees of freedom linkage with the hip and knee as its joints. Kinematic data of hip and knee joints were recorded by a motion analysis system. Through a static optimization approach, the forces exerted by muscles were determined so that recorded hip and knee joint angles were produced. Simulation results showed that when the mass of prosthetic foot is increased, muscle forces increase, too. This result is in accord with experimental and theoretical studies that reported an increase in leg mass lead to higher electromyography activity of muscles, and energetic of walking. However, since prosthetic foot moment of inertia is smaller than that of thigh and prosthetic shank, its alternation does not have noticeable effect on muscle forces.
- 30 September 2010
- Vol.Ā 56 Ā (3) , E92-7
Effects of mass and momentum of inertia alternation on individual muscle forces during swing phase of transtibial amputee gait.
A computer simulation was carried out to investigate the forces of lower extremity muscles in the swing phase of a transtibial amputee gait. With each muscle as an ideal force generator, the lower extremity was simulated as a two-degrees of freedom linkage with the hip and knee as its joints. Kinematic data of hip and knee joints were recorded by a motion analysis system. Through a static optimization approach, the forces exerted by muscles were determined so that recorded hip and knee joint angles were produced. Simulation results showed that when the mass of prosthetic foot is increased, muscle forces increase, too. This result is in accord with experimental and theoretical studies that reported an increase in leg mass lead to higher electromyography activity of muscles, and energetic of walking. However, since prosthetic foot moment of inertia is smaller than that of thigh and prosthetic shank, its alternation does not have noticeable effect on muscle forces.