Hiroo Tarao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroo Tarao has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Katsuo Isaka
The University of Tokushima, Tokushima-shi, JAPAN
6 shared publications- Leena Korpinen
The Clinical Physiology and Neurophysiology Unit, The North Karelia Central Hospital and Honkalampi Centre, Tikkamäentie 16, FIN-80210 Joensuu, Finland
6 shared publications Noriyuki Hayashi
University of Miyazaki, Miyazaki-shi, Japan
3 shared publications- Noriyuki Hayashi
Faculty of Engineering, University of Miyazaki
3 shared publications Amane Takei
Faculty of Engineering University of Miyazaki Japan
2 shared publications- Amane Takei
Faculty of Engineering, University of Miyazaki, Miyazaki City 889-2155, Japan
2 shared publications
Latest Publications
- 4 February 2021
- Published by Wiley in Bioelectromagnetics
- Vol. 42 (3) , 224-237
Evaluation of Temperature Increase From Joule Heat in Numerical Tooth Model by Applying 500 kHz Current for Apical Periodontitis Treatment—Effect of Applied Voltage and Tooth Conductivity
For apical periodontitis treatments, a new method with the insertion of an electrode into the root canal of a tooth and application of a current at 500 kHz to sterilize the area by Joule heat has attracted attention. However, few studies have quantified the temperature increase in the root canal. This study aimed to investigate the basic characteristics of the temperature increase in a simple and standard tooth model when energizing a current at 500 kHz to the numerical tooth model with typical electrical and physical properties. We developed a numerical model of a standard tooth (dentin) and periodontal tissues consisting of an alveolar bone, cortical bone, and gingiva, and physiological saline in a root canal and calculated the temperature increase inside the numerical model by a coupled analysis of current and heat when a voltage was applied across the electrodes. The calculated results for the different applied voltages showed a temperature increase at the apical portion of the root canal, which increased with the applied voltage even for the same total supplied energy. The temperature increase occurred at the apical portion of the root canal as the tooth conductivity decreased. When the tooth conductivity was high, a current passed through the dentin, which led to a decrease in the temperature at the apical portion of the root canal. However, a chemical solution with a higher conductivity in the root canal tended to increase the temperature at the apical portion of the root canal, regardless of the tooth conductivity. More efficient approaches for increasing the spatial and temporal temperature for the tooth model target are needed. © 2021 Bioelectromagnetics Society.
- 4 February 2021
- Published by Wiley in Bioelectromagnetics
- Vol. 42 (3) , 224-237
Evaluation of Temperature Increase From Joule Heat in Numerical Tooth Model by Applying 500 kHz Current for Apical Periodontitis Treatment—Effect of Applied Voltage and Tooth Conductivity
For apical periodontitis treatments, a new method with the insertion of an electrode into the root canal of a tooth and application of a current at 500 kHz to sterilize the area by Joule heat has attracted attention. However, few studies have quantified the temperature increase in the root canal. This study aimed to investigate the basic characteristics of the temperature increase in a simple and standard tooth model when energizing a current at 500 kHz to the numerical tooth model with typical electrical and physical properties. We developed a numerical model of a standard tooth (dentin) and periodontal tissues consisting of an alveolar bone, cortical bone, and gingiva, and physiological saline in a root canal and calculated the temperature increase inside the numerical model by a coupled analysis of current and heat when a voltage was applied across the electrodes. The calculated results for the different applied voltages showed a temperature increase at the apical portion of the root canal, which increased with the applied voltage even for the same total supplied energy. The temperature increase occurred at the apical portion of the root canal as the tooth conductivity decreased. When the tooth conductivity was high, a current passed through the dentin, which led to a decrease in the temperature at the apical portion of the root canal. However, a chemical solution with a higher conductivity in the root canal tended to increase the temperature at the apical portion of the root canal, regardless of the tooth conductivity. More efficient approaches for increasing the spatial and temporal temperature for the tooth model target are needed. © 2021 Bioelectromagnetics Society.
- 24 August 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (5) , 055012
Estimation of short-circuit current induced by ELF uniform electric fields in grounded humans with different body shapes based on a semi-ellipsoidal model
It has been reported that when a grounded human is exposed to an electric field at power frequency, a short-circuit current flowing from the feet to the ground is proportional to the square of his or her height. The current, however, should also vary with the body surface area, that is, body shape, even in people with the same height. In the present study, we confirmed this hypothesis using an analytical solution derived from a semi-ellipsoidal model. The short-circuit currents were calculated for various numerical human body models in which the horizontal length of a voxel was varied from 1.8 to 3.0 mm, and the results for different body shapes were compared. Finally, we derived an approximate expression for estimating the short-circuit current from the left-right width (2 b ), frontal thickness (2 c ), and height ( a ) of a human from the analytical solution. The short-circuit currents obtained from the approximate expression are consistent with those obtained from numerical calculations for 48 differently shaped human body models with a correlation coefficient of 0.9942. Hence, we concluded that the short-circuit current can be determined depending on the similarity ratio ( a / b ) and the ellipticity ratio ( c / b ) of the human body as well as the height. This finding is consistent with the numerical human body models that have been used previously, in which the similarity and ellipticity ratios were very close. Therefore, we can make the limited conclusion that the short-circuit current is proportional only to the square of the height. Additionally, numerical calculations showed that the short-circuit current is the same whether one foot or both feet are grounded.
- 24 August 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (5) , 055012
Estimation of short-circuit current induced by ELF uniform electric fields in grounded humans with different body shapes based on a semi-ellipsoidal model
It has been reported that when a grounded human is exposed to an electric field at power frequency, a short-circuit current flowing from the feet to the ground is proportional to the square of his or her height. The current, however, should also vary with the body surface area, that is, body shape, even in people with the same height. In the present study, we confirmed this hypothesis using an analytical solution derived from a semi-ellipsoidal model. The short-circuit currents were calculated for various numerical human body models in which the horizontal length of a voxel was varied from 1.8 to 3.0 mm, and the results for different body shapes were compared. Finally, we derived an approximate expression for estimating the short-circuit current from the left-right width (2 b ), frontal thickness (2 c ), and height ( a ) of a human from the analytical solution. The short-circuit currents obtained from the approximate expression are consistent with those obtained from numerical calculations for 48 differently shaped human body models with a correlation coefficient of 0.9942. Hence, we concluded that the short-circuit current can be determined depending on the similarity ratio ( a / b ) and the ellipticity ratio ( c / b ) of the human body as well as the height. This finding is consistent with the numerical human body models that have been used previously, in which the similarity and ellipticity ratios were very close. Therefore, we can make the limited conclusion that the short-circuit current is proportional only to the square of the height. Additionally, numerical calculations showed that the short-circuit current is the same whether one foot or both feet are grounded.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (6) , 1-5
Analysis of Current Density Inside Human Body Using Geometric Multi-Grid Method
This paper describes the effectiveness of a geometric multi-grid (GMG) method in current density analysis using numerical human body models. The scalar potential finite difference (SPFD) method is used as a current analysis method inside a human body in the low-frequency domain, and studies have been conducted to solve faster large-scale linear equations made by the SPFD method. In the previous research, the block incomplete Cholesky conjugate gradients (ICCG) method is proposed as an effective method to solve linear equations faster. However, even though the block ICCG method is applied, many iterations are still needed. Therefore, in this research, the GMG method is considered as an effective solver for the problem. GMG method is developed and evaluated performances comparing with the block ICCG method with multi-color (MC) ordering in terms of computation time and the number of iterations. The results show that the number of iterations needed for GMG method is much smaller than that for the block ICCG and the ICCG with MC ordering. In addition, computation times are much shorter, depending on the number of threads and the number of coarse grids. Also, by using MC ordering, the scalability of the GMG method can be greatly improved.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (6) , 1-5
Analysis of Current Density Inside Human Body Using Geometric Multi-Grid Method
This paper describes the effectiveness of a geometric multi-grid (GMG) method in current density analysis using numerical human body models. The scalar potential finite difference (SPFD) method is used as a current analysis method inside a human body in the low-frequency domain, and studies have been conducted to solve faster large-scale linear equations made by the SPFD method. In the previous research, the block incomplete Cholesky conjugate gradients (ICCG) method is proposed as an effective method to solve linear equations faster. However, even though the block ICCG method is applied, many iterations are still needed. Therefore, in this research, the GMG method is considered as an effective solver for the problem. GMG method is developed and evaluated performances comparing with the block ICCG method with multi-color (MC) ordering in terms of computation time and the number of iterations. The results show that the number of iterations needed for GMG method is much smaller than that for the block ICCG and the ICCG with MC ordering. In addition, computation times are much shorter, depending on the number of threads and the number of coarse grids. Also, by using MC ordering, the scalability of the GMG method can be greatly improved.
- Open Access
- 16 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 70964-70973
Intercomparison of In Situ Electric Fields in Human Models Exposed to Spatially Uniform Magnetic Fields
IEEE C95.1 (radio frequency) and C95.6 (low frequency) standards for human protection from electromagnetic fields are currently under revision. In the next revision, they will be combined into one standard covering the frequency range from 0 Hz to 300 GHz. Although the C95.1 standard considers anatomical human models for deriving the relationship between internal and external field strengths, homogeneous ellipses are used in the C95.6 standard. In the guidelines of the International Commission on Non-Ionizing Radiation Protection, anatomical human models are used together with reduction factors to account for numerical uncertainty. It is worth revisiting their relationship when using different anatomical models. In this paper, five research groups performed a comparative study to update the state-of-the-art knowledge of in situ electric fields in anatomical human models when exposed to uniform low-frequency magnetic fields. The main goals were to clarify both numerical uncertainty and model variability. The computational results suggest a high consistency among in situ field strengths across laboratories; agreement in the 99th percentile with a discrepancy of under 5% was achieved. The in situ electric fields varied as expected given the models' different dimensions. The induction factor, which is the ratio of the in situ electric fields for the temporal derivative of the external magnetic flux density, is derived for body parts and tissues. The classification of body parts into “the limb” and “other tissues”is shown to be critical for determining the in situ field strength.
- 16 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 70964-70973
Open AccessIntercomparison of In Situ Electric Fields in Human Models Exposed to Spatially Uniform Magnetic Fields
IEEE C95.1 (radio frequency) and C95.6 (low frequency) standards for human protection from electromagnetic fields are currently under revision. In the next revision, they will be combined into one standard covering the frequency range from 0 Hz to 300 GHz. Although the C95.1 standard considers anatomical human models for deriving the relationship between internal and external field strengths, homogeneous ellipses are used in the C95.6 standard. In the guidelines of the International Commission on Non-Ionizing Radiation Protection, anatomical human models are used together with reduction factors to account for numerical uncertainty. It is worth revisiting their relationship when using different anatomical models. In this paper, five research groups performed a comparative study to update the state-of-the-art knowledge of in situ electric fields in anatomical human models when exposed to uniform low-frequency magnetic fields. The main goals were to clarify both numerical uncertainty and model variability. The computational results suggest a high consistency among in situ field strengths across laboratories; agreement in the 99th percentile with a discrepancy of under 5% was achieved. The in situ electric fields varied as expected given the models' different dimensions. The induction factor, which is the ratio of the in situ electric fields for the temporal derivative of the external magnetic flux density, is derived for body parts and tissues. The classification of body parts into “the limb” and “other tissues”is shown to be critical for determining the in situ field strength.
- 12 August 2018
- Published by Wiley in Electronics and Communications in Japan
- Vol. 101 (10) , 3-10
Electric fields induced inside numerical human model standing on ground plane with elevated arms in uniform electric field at power frequency
In the ICNIRP guidelines on the protection of human exposure to low frequency electric and magnetic fields, the reference levels are given based on the maximum value of induced electric fields (EF’s) inside a numerical human model that stands erect on ground plane with both hands down by its sides. In this contribution, numerical results on the induced EF’s inside a numerical human model standing with elevated arms in a 50 Hz uniform EF, are illustrated. The effect of the arm elevation angle on the maximum EF is discussed. It is found that, when both arms are raised overhead, the maximum values of the induced EF in the nervous system tissues increase by 20–35% compared with those obtained when both hands are down by its sides, which falls within the reduction factor of 2.4.
- 12 August 2018
- Published by Wiley in Electronics and Communications in Japan
- Vol. 101 (10) , 3-10
Electric fields induced inside numerical human model standing on ground plane with elevated arms in uniform electric field at power frequency
In the ICNIRP guidelines on the protection of human exposure to low frequency electric and magnetic fields, the reference levels are given based on the maximum value of induced electric fields (EF’s) inside a numerical human model that stands erect on ground plane with both hands down by its sides. In this contribution, numerical results on the induced EF’s inside a numerical human model standing with elevated arms in a 50 Hz uniform EF, are illustrated. The effect of the arm elevation angle on the maximum EF is discussed. It is found that, when both arms are raised overhead, the maximum values of the induced EF in the nervous system tissues increase by 20–35% compared with those obtained when both hands are down by its sides, which falls within the reduction factor of 2.4.
- Open Access
- 25 May 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (12) , 4438-4451
Simple estimation of induced electric fields in nervous system tissues for human exposure to non-uniform electric fields at power frequency
Most results regarding induced current in the human body related to electric field dosimetry have been calculated under uniform field conditions. We have found in previous work that a contact current is a more suitable way to evaluate induced electric fields, even in the case of exposure to non-uniform fields. If the relationship between induced currents and external non-uniform fields can be understood, induced electric fields in nervous system tissues may be able to be estimated from measurements of ambient non-uniform fields. In the present paper, we numerically calculated the induced electric fields and currents in a human model by considering non-uniform fields based on distortion by a cubic conductor under an unperturbed electric field of 1 kV m−1 at 60 Hz. We investigated the relationship between a non-uniform external electric field with no human present and the induced current through the neck, and the relationship between the current through the neck and the induced electric fields in nervous system tissues such as the brain, heart, and spinal cord. The results showed that the current through the neck can be formulated by means of an external electric field at the central position of the human head, and the distance between the conductor and the human model. As expected, there is a strong correlation between the current through the neck and the induced electric fields in the nervous system tissues. The combination of these relationships indicates that induced electric fields in these tissues can be estimated solely by measurements of the external field at a point and the distance from the conductor.
- 25 May 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (12) , 4438-4451
Open AccessSimple estimation of induced electric fields in nervous system tissues for human exposure to non-uniform electric fields at power frequency
Most results regarding induced current in the human body related to electric field dosimetry have been calculated under uniform field conditions. We have found in previous work that a contact current is a more suitable way to evaluate induced electric fields, even in the case of exposure to non-uniform fields. If the relationship between induced currents and external non-uniform fields can be understood, induced electric fields in nervous system tissues may be able to be estimated from measurements of ambient non-uniform fields. In the present paper, we numerically calculated the induced electric fields and currents in a human model by considering non-uniform fields based on distortion by a cubic conductor under an unperturbed electric field of 1 kV m−1 at 60 Hz. We investigated the relationship between a non-uniform external electric field with no human present and the induced current through the neck, and the relationship between the current through the neck and the induced electric fields in nervous system tissues such as the brain, heart, and spinal cord. The results showed that the current through the neck can be formulated by means of an external electric field at the central position of the human head, and the distance between the conductor and the human model. As expected, there is a strong correlation between the current through the neck and the induced electric fields in the nervous system tissues. The combination of these relationships indicates that induced electric fields in these tissues can be estimated solely by measurements of the external field at a point and the distance from the conductor.
- 1 January 2016
- Published by Wolters Kluwer Health in Health Physics
- Vol. 110 (1) , 1-10
Possible Influences of Spark Discharges on Cardiac Pacemakers
Exposure to spark discharges may occur beneath high voltage transmission lines when contact is initiated with a conductive object (such as a motor vehicle) with the spark discharge mediated by the ambient electric field from the line. The objective of this study was to assess whether such exposures could interfere with the normal functioning of implanted cardiac pacemakers (PMs). The experiment consisted of PMs implanted in a human-sized phantom and then exposed to spark discharge through an upper extremity. A circuit was designed that produced spark discharges between two spherical electrodes fed to the phantom's left hand. The circuit was set to deliver a single discharge per half cycle (every 10 ms) about 10 μs in duration with a peak current of 1.2-1.3 A, thus simulating conditions under a 400-kV power line operating at 50 Hz. Of 29 PMs acquired, all were tested in unipolar configuration and 20 in bipolar configuration with exposure consisting of 2 min of continuous exposure (one unit was exposed for 1 min). No interference was observed in bipolar configuration. One unit in unipolar configuration incorrectly identified ventricular extra systoles (more than 400 beats min(-1)) for 2 s. The use of unipolar configuration in new implants is extremely rare, thus further minimizing the risk of interference with the passage of time. Replication of this study and, if safety for human subjects can be assured, future testing of human subjects is also advisable.
- 1 January 2016
- Published by Wolters Kluwer Health in Health Physics
- Vol. 110 (1) , 1-10
Possible Influences of Spark Discharges on Cardiac Pacemakers
Exposure to spark discharges may occur beneath high voltage transmission lines when contact is initiated with a conductive object (such as a motor vehicle) with the spark discharge mediated by the ambient electric field from the line. The objective of this study was to assess whether such exposures could interfere with the normal functioning of implanted cardiac pacemakers (PMs). The experiment consisted of PMs implanted in a human-sized phantom and then exposed to spark discharge through an upper extremity. A circuit was designed that produced spark discharges between two spherical electrodes fed to the phantom's left hand. The circuit was set to deliver a single discharge per half cycle (every 10 ms) about 10 μs in duration with a peak current of 1.2-1.3 A, thus simulating conditions under a 400-kV power line operating at 50 Hz. Of 29 PMs acquired, all were tested in unipolar configuration and 20 in bipolar configuration with exposure consisting of 2 min of continuous exposure (one unit was exposed for 1 min). No interference was observed in bipolar configuration. One unit in unipolar configuration incorrectly identified ventricular extra systoles (more than 400 beats min(-1)) for 2 s. The use of unipolar configuration in new implants is extremely rare, thus further minimizing the risk of interference with the passage of time. Replication of this study and, if safety for human subjects can be assured, future testing of human subjects is also advisable.
- 3 April 2015
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 21 (2) , 229-232
Cardiac pacemakers in magnetic fields of a shunt reactor at a 400 kV substation
The use of cardiac pacemakers (PMs) increases in Western countries. The aim of the study is to investigate cardiac pacemakers (PMs) using a human-shaped phantom in magnetic fields of a shunt reactor at a 400 kV substation. We performed seven PM experiments using a phantom. Two locations close to the shunt reactors were chosen. The magnetic field exposure was over 1000 µT in one location and over 600 µT in the other one. The magnetic field exposure did not disturb the tested five different PMs (in unipolar or bipolar configurations). It can be stated that in our experiment, the magnetic field exposure (over 600 µT and over 1000 µT) did not disturb the PMs (in unipolar or bipolar configurations). Since we only studied some PMs, it is possible that the magnetic field exposure at 400 kV substations can cause disturbances to other PMs. However, the risk of disturbances does not seem to be high.
- 3 April 2015
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 21 (2) , 229-232
Cardiac pacemakers in magnetic fields of a shunt reactor at a 400 kV substation
The use of cardiac pacemakers (PMs) increases in Western countries. The aim of the study is to investigate cardiac pacemakers (PMs) using a human-shaped phantom in magnetic fields of a shunt reactor at a 400 kV substation. We performed seven PM experiments using a phantom. Two locations close to the shunt reactors were chosen. The magnetic field exposure was over 1000 µT in one location and over 600 µT in the other one. The magnetic field exposure did not disturb the tested five different PMs (in unipolar or bipolar configurations). It can be stated that in our experiment, the magnetic field exposure (over 600 µT and over 1000 µT) did not disturb the PMs (in unipolar or bipolar configurations). Since we only studied some PMs, it is possible that the magnetic field exposure at 400 kV substations can cause disturbances to other PMs. However, the risk of disturbances does not seem to be high.