TDTom Depuydt

Tom Depuydt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tom Depuydt has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Initial assessment of tumor tracking with a gimbaled linac system in clinical circumstances: A patient simulation study

    by Tom Depuydt, Kenneth Poels, Dirk Verellen, Benedikt Engels, Christine Collen, Chloe Haverbeke, Thierry Gevaert, Nico Buls, Gert Van Gompel, Truus Reynders, et al.


  • Computer-aided analysis of star shot films for high-accuracy radiation therapy treatment units

    by Tom Depuydt, Rudi Penne, Dirk Verellen, Jan Hrbacek, Stephanie Lang, Katrien Leysen, Iwein Vandevondel, Kenneth Poels, Truus Reynders, Thierry Gevaert, et al.

    As mechanical stability of radiation therapy treatment devices has gone beyond sub-millimeter levels, there is a rising demand for simple yet highly accurate measurement techniques to support the routine quality control of these devices. A combination of using high-resolution radiosensitive film and computer-aided analysis could provide an answer. One generally known technique is the acquisition of star shot films to determine the mechanical stability of rotations of gantries and the therapeutic beam. With computer-aided analysis, mechanical performance can be quantified as a radiation isocenter radius size. In this work, computer-aided analysis of star shot film is further refined by applying an analytical solution for the smallest intersecting circle problem, in contrast to the gradient optimization approaches used until today. An algorithm is presented and subjected to a performance test using two different types of radiosensitive film, the Kodak EDR2 radiographic film and the ISP EBT2 radiochromic film. Artificial star shots with a priori known radiation isocenter size are used to determine the systematic errors introduced by the digitization of the film and the computer analysis. The estimated uncertainty on the isocenter size measurement with the presented technique was 0.04 mm (2σ) and 0.06 mm (2σ) for radiographic and radiochromic films, respectively. As an application of the technique, a study was conducted to compare the mechanical stability of O-ring gantry systems with C-arm-based gantries. In total ten systems of five different institutions were included in this study and star shots were acquired for gantry, collimator, ring, couch rotations and gantry wobble. It was not possible to draw general conclusions about differences in mechanical performance between O-ring and C-arm gantry systems, mainly due to differences in the beam-MLC alignment procedure accuracy. Nevertheless, the best performing O-ring system in this study, a BrainLab/MHI Vero system, and the best performing C-arm system, a Varian Truebeam system, showed comparable mechanical performance: gantry isocenter radius of 0.12 and 0.09 mm, respectively, ring/couch rotation of below 0.10 mm for both systems and a wobble of 0.06 and 0.18 mm, respectively. The methodology described in this work can be used to monitor mechanical performance constancy of high-accuracy treatment devices, with means available in a clinical radiation therapy environment.


  • Treatment delivery time optimization of respiratory gated radiation therapy by application of audio-visual feedback

    by T. Gevaert, D. Verellen, I. Van de Vondel, B. Engels, K. Tournel, M. Duchateau, T. Reynders, Tom Depuydt, M. Boussaer, K. Poels, et al.

  • Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system

    by Tom Depuydt, Dirk Verellen, Olivier Haas, Thierry Gevaert, Nadine Linthout, Michael Duchateau, Koen Tournel, Truus Reynders, Katrien Leysen, Mischa Hoogeman, et al.


  • Quantitative evaluation of a beam-matching procedure using one-dimensional gamma analysis

    by Jan Hrbacek, Tom Depuydt, An Nulens, Ans Swinnen, Frank Van Den Heuvel

    This article provides a quantitative evaluation of Varian Medical Systems' beam matching procedure. A one-dimensional y analysis is employed to investigate the level of agreement of matched beams. A customized concept of one-dimensional gamma evaluation was designed. Our algorithm first performs a "local" fit of the reference and the evaluated datasets. For a particular point on the fitted evaluated curve, the y is derived as the shortest distance between the point and the fitted reference curve. This approach removes variations of the obtained y value related to the discrete character and noise in the original datasets. Criteria of 1 mm distance-to-agreement and 1% dose difference were used to evaluate the level of agreement of according profiles. Relative point and profile measurements were performed for all photon and electron beams of two Varian Clinacs 2100C/D. Matched beams show a good level of agreement. 70% of profiles completely pass the chosen criteria. The analysis of remaining 30% of the profiles demonstrates that measurement error becomes a limiting factor in achieving a better score. The highest obtained y value was 1.70. The quality of beam matching allowed us to treat according beams of both treatment units as "identical" and to use the reference beam data for the new unit. Nevertheless, the vendor's acceptance criteria of beam matching are much more benevolent. It might happen that the acceptance criteria are met, however, resulting quality of beam matching does not allow full interchangeability of beams.