Stephen Collins Stephen Collins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stephen Collins Stephen Collins has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Greg Baxter
Optical Technology Research Laboratory, College of Engineering and Science, Victoria University, P.O. Box 14428, Melbourne, VIC 8001, Australia
10 shared publications - Scott A. Wade
The Australian Research Council (ARC) Training Centre in Surface Engineering for Advanced Materials (SEAM), School of Engineering, Swinburne University of Technology, P.O. Box 218, Hawthorn, VIC 3122, Australia
10 shared publications - Fotios Sidiroglou
Victoria University
6 shared publications Claire M. Rollinson
Optical Technology Research Laboratory, College of Engineering and Science, Victoria University, P.O. Box 14428, Melbourne, VIC 8001, Australia
3 shared publicationsHarpreet K. Bal
Optical Technology Research Laboratory, School of Engineering and Science, Victoria University, PO Box 14428, Melbourne, VIC 8001, Australia
3 shared publications- Zourab Brodzeli
School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney NSW 2052, Australia
3 shared publications
Latest Publications
- Open Access
Proof of Concept for Light Conducting Membrane Substrate for UV-Activated Photocatalysis as an Alternative to Chemical Cleaning
Adopting an effective strategy to control fouling is a necessary requirement for all membrane processes used in the water/wastewater treatment industry to operate sustainably. The use of ultraviolet (UV) activated photocatalysis has been shown to be effective in mitigating ceramic membrane fouling by natural organic matter. The widely used configuration in which light is directed through the polluted water to the membrane’s active layer suffers from inefficiencies brought about by light absorption by the pollutants and light shielding by the cake layer. To address these limitations, directing light through the substrate, instead of through polluted water, was studied. A UV conducting membrane was prepared by dip coating TiO2 onto a sintered glass substrate. The substrate could successfully conduct UV from a lamp source, unlike a typical alumina substrate. The prepared membrane was applied in the filtration of a humic acid solution as a model compound to study natural organic matter membrane fouling. Directing UV through the substrate showed only a 1 percentage point decline in the effectiveness of the cleaning method over two cleaning events from 72% to 71%, while directing UV over the photocatalytic layer had a 9 percentage point decline from 84% to 75%. Adapting the UV-through-substrate configuration could be more useful in maintaining membrane functionality during humic acid filtration than the current method being used.
Open AccessProof of Concept for Light Conducting Membrane Substrate for UV-Activated Photocatalysis as an Alternative to Chemical Cleaning
Adopting an effective strategy to control fouling is a necessary requirement for all membrane processes used in the water/wastewater treatment industry to operate sustainably. The use of ultraviolet (UV) activated photocatalysis has been shown to be effective in mitigating ceramic membrane fouling by natural organic matter. The widely used configuration in which light is directed through the polluted water to the membrane’s active layer suffers from inefficiencies brought about by light absorption by the pollutants and light shielding by the cake layer. To address these limitations, directing light through the substrate, instead of through polluted water, was studied. A UV conducting membrane was prepared by dip coating TiO2 onto a sintered glass substrate. The substrate could successfully conduct UV from a lamp source, unlike a typical alumina substrate. The prepared membrane was applied in the filtration of a humic acid solution as a model compound to study natural organic matter membrane fouling. Directing UV through the substrate showed only a 1 percentage point decline in the effectiveness of the cleaning method over two cleaning events from 72% to 71%, while directing UV over the photocatalytic layer had a 9 percentage point decline from 84% to 75%. Adapting the UV-through-substrate configuration could be more useful in maintaining membrane functionality during humic acid filtration than the current method being used.
- Open Access
- 15 June 2017
- Published by MDPI AG in Electronics
- Vol. 6 (2) , 47
A Galvanic Intrabody Method for Assessing Fluid Flow in Unilateral Lymphoedema
Lymphoedema is a disease associated with abnormal functioning of the lymph that leads to swelling of the body due to accumulation of tissue fluid on the affected area. Tissue fluid contains ions and electrolytes that affect electrical conductivity. The flow of tissue fluid helps to distribute vital nutrients and other important elements necessary for healthy living. When tissue fluid is stagnated, a high concentration of electrolytes accumulate on the affected area, which in turn affects an electrical signal passing through that area to be minimally attenuated in relation to a free-flowing fluid. We demonstrate that a galvanic coupled signal propagating along a lymphoedema affected limb could capture these changes by the amount of attenuation the propagating signal experiences in time. Our results show that average rate of signal attenuation on a lymphoedema affected part of the body could be as slow as 0.16 dB/min, while the rate of signal attenuation on a healthy part is as high as 1.83 dB/min. This means that fluid accumulation could slow down the exchange of body electrolytes up to twice less the rate on an unaffected contralateral part of the body. Monitoring these changes by observing the average rate of change of a galvanic coupled signal attenuation on the affected body part can be used for diagnosing early developments of oedema in the body and for evaluating recovery in response to treatment procedures.
- 15 June 2017
- Published by MDPI AG in Electronics
- Vol. 6 (2) , 47
Open AccessA Galvanic Intrabody Method for Assessing Fluid Flow in Unilateral Lymphoedema
Lymphoedema is a disease associated with abnormal functioning of the lymph that leads to swelling of the body due to accumulation of tissue fluid on the affected area. Tissue fluid contains ions and electrolytes that affect electrical conductivity. The flow of tissue fluid helps to distribute vital nutrients and other important elements necessary for healthy living. When tissue fluid is stagnated, a high concentration of electrolytes accumulate on the affected area, which in turn affects an electrical signal passing through that area to be minimally attenuated in relation to a free-flowing fluid. We demonstrate that a galvanic coupled signal propagating along a lymphoedema affected limb could capture these changes by the amount of attenuation the propagating signal experiences in time. Our results show that average rate of signal attenuation on a lymphoedema affected part of the body could be as slow as 0.16 dB/min, while the rate of signal attenuation on a healthy part is as high as 1.83 dB/min. This means that fluid accumulation could slow down the exchange of body electrolytes up to twice less the rate on an unaffected contralateral part of the body. Monitoring these changes by observing the average rate of change of a galvanic coupled signal attenuation on the affected body part can be used for diagnosing early developments of oedema in the body and for evaluating recovery in response to treatment procedures.
- Open Access
- 13 July 2016
- Published by MDPI AG in Electronics
- Vol. 5 (3) , 39
A Galvanic Coupling Method for Assessing Hydration Rates
Recent advances in biomedical sensors, data acquisition techniques, microelectronics and wireless communication systems opened up the use of wearable technology for ehealth monitoring. We introduce a galvanic coupled intrabody communication for monitoring human body hydration. Studies in hydration provide the information necessary for understanding the desired fluid levels for optimal performance of the body’s physiological and metabolic processes during exercise and activities of daily living. Current measurement techniques are mostly suitable for laboratory purposes due to their complexity and technical requirements. Less technical methods such as urine color observation and skin turgor testing are subjective and cannot be integrated into a wearable device. Bioelectrical impedance methods are popular but mostly used for estimating total body water with limited accuracy and sensitive to 800 mL–1000 mL change in body fluid levels. We introduce a non-intrusive and simple method of tracking hydration rates that can detect up to 1.30 dB reduction in attenuation when as little as 100 mL of water is consumed. Our results show that galvanic coupled intrabody signal propagation can provide qualitative hydration and dehydration rates in line with changes in an individual’s urine specific gravity and body mass. The real-time changes in galvanic coupled intrabody signal attenuation can be integrated into wearable electronic devices to evaluate body fluid levels on a particular area of interest and can aid diagnosis and treatment of fluid disorders such as lymphoedema.
- 13 July 2016
- Published by MDPI AG in Electronics
- Vol. 5 (3) , 39
Open AccessA Galvanic Coupling Method for Assessing Hydration Rates
Recent advances in biomedical sensors, data acquisition techniques, microelectronics and wireless communication systems opened up the use of wearable technology for ehealth monitoring. We introduce a galvanic coupled intrabody communication for monitoring human body hydration. Studies in hydration provide the information necessary for understanding the desired fluid levels for optimal performance of the body’s physiological and metabolic processes during exercise and activities of daily living. Current measurement techniques are mostly suitable for laboratory purposes due to their complexity and technical requirements. Less technical methods such as urine color observation and skin turgor testing are subjective and cannot be integrated into a wearable device. Bioelectrical impedance methods are popular but mostly used for estimating total body water with limited accuracy and sensitive to 800 mL–1000 mL change in body fluid levels. We introduce a non-intrusive and simple method of tracking hydration rates that can detect up to 1.30 dB reduction in attenuation when as little as 100 mL of water is consumed. Our results show that galvanic coupled intrabody signal propagation can provide qualitative hydration and dehydration rates in line with changes in an individual’s urine specific gravity and body mass. The real-time changes in galvanic coupled intrabody signal attenuation can be integrated into wearable electronic devices to evaluate body fluid levels on a particular area of interest and can aid diagnosis and treatment of fluid disorders such as lymphoedema.
- 5 April 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (8) , 1696-1699
UiO-66 MOF end-face-coated optical fiber in aqueous contaminant detection
Optical quality metal organic framework (MOF) thin films were integrated, for the first time, to the best of our knowledge, with structured optical fiber substrates to develop MOF-fiber sensors. The MOF-fiber structure, UiO-66 (Zr-based MOF is well known for its water stability), is a thin film that acts as an effective analyte collector. This provided a Fabry–Perot sensor in which concentrations of up to 15 mM Rhodamine-B were detected via wavelength shifts in the interference spectrum.
- 5 April 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (8) , 1696-1699
UiO-66 MOF end-face-coated optical fiber in aqueous contaminant detection
Optical quality metal organic framework (MOF) thin films were integrated, for the first time, to the best of our knowledge, with structured optical fiber substrates to develop MOF-fiber sensors. The MOF-fiber structure, UiO-66 (Zr-based MOF is well known for its water stability), is a thin film that acts as an effective analyte collector. This provided a Fabry–Perot sensor in which concentrations of up to 15 mM Rhodamine-B were detected via wavelength shifts in the interference spectrum.
- 26 January 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (4) , 783-790
Imaging of various optical fiber Bragg gratings using differential interference contrast microscopy: analysis and comparison
Differential interference contrast images of various optical fibers and optical fiber Bragg gratings (FBGs), written with the phase mask technique, are presented to provide information about the resultant refractive index variations present in each case. Use of different fiber types using two distinct phase masks producing four Type I FBGs and a Type In FBG allowed similarities and differences in these FBG images due to variations in the Talbot diffraction patterns produced to be studied.
- 26 January 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (4) , 783-790
Imaging of various optical fiber Bragg gratings using differential interference contrast microscopy: analysis and comparison
Differential interference contrast images of various optical fibers and optical fiber Bragg gratings (FBGs), written with the phase mask technique, are presented to provide information about the resultant refractive index variations present in each case. Use of different fiber types using two distinct phase masks producing four Type I FBGs and a Type In FBG allowed similarities and differences in these FBG images due to variations in the Talbot diffraction patterns produced to be studied.
- 1 January 2016
- Published by Shanghai Institute of Optics and Fine Mechanics in Laser & Optoelectronics Progress
- Vol. 53 (5) , 53001
Multi-Functional Temperature Sensing with the Fluorescence of (Ba,Sr)2SiO4:Eu2+
The steady-state temperature-dependent fluorescence of (Ba,Sr)2SiO4∶Eu2+ is studied, under an excitation at 405 nm. After the raise of two novel sensing methods, barycenter technique and intensity ratio technique for wide band emissions, multiple sensing functions are retrieved, using the behaviors of wavenumber/wavelength of emission band barycenter, emission bandwidth, and ratios of intensities at different wavelengths in the emission band, respectively. All the four kinds of functions demonstrate nearly linear relationship with temperature in the measurement range. The sensing mechanisms are briefly discussed. The phosphor′s multi-functional temperaturesensing abilities can be taken advantages of for use as a point thermometer for a variety of applications.
- 1 January 2016
- Published by Shanghai Institute of Optics and Fine Mechanics in Laser & Optoelectronics Progress
- Vol. 53 (5) , 53001
Multi-Functional Temperature Sensing with the Fluorescence of (Ba,Sr)2SiO4:Eu2+
The steady-state temperature-dependent fluorescence of (Ba,Sr)2SiO4∶Eu2+ is studied, under an excitation at 405 nm. After the raise of two novel sensing methods, barycenter technique and intensity ratio technique for wide band emissions, multiple sensing functions are retrieved, using the behaviors of wavenumber/wavelength of emission band barycenter, emission bandwidth, and ratios of intensities at different wavelengths in the emission band, respectively. All the four kinds of functions demonstrate nearly linear relationship with temperature in the measurement range. The sensing mechanisms are briefly discussed. The phosphor′s multi-functional temperaturesensing abilities can be taken advantages of for use as a point thermometer for a variety of applications.
- 24 July 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (9) , 094008
Optical fibre Bragg gratings at harmonics of the Bragg wavelength and their sensing properties
Spectral features in optical fibre Bragg gratings (FBGs) at various harmonics of the Bragg wavelength arise due to saturation of the writing process. Additionally, phase-mask-produced FBGs possess a complex refractive index pattern, producing an extra periodicity equal to the phase-mask periodicity that supplements the desired periodicity of half that of the phase-mask, as shown via differential interference contrast microscopy. Some spectral peaks or dips occur as doublets with a wavelength spacing that depends upon fibre alignment relative to the phase mask. These spectral properties are of importance, as they allow the realization of alternative FBG sensors of various measurands.
- 24 July 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (9) , 094008
Optical fibre Bragg gratings at harmonics of the Bragg wavelength and their sensing properties
Spectral features in optical fibre Bragg gratings (FBGs) at various harmonics of the Bragg wavelength arise due to saturation of the writing process. Additionally, phase-mask-produced FBGs possess a complex refractive index pattern, producing an extra periodicity equal to the phase-mask periodicity that supplements the desired periodicity of half that of the phase-mask, as shown via differential interference contrast microscopy. Some spectral peaks or dips occur as doublets with a wavelength spacing that depends upon fibre alignment relative to the phase mask. These spectral properties are of importance, as they allow the realization of alternative FBG sensors of various measurands.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8421, 84211Z
Understanding fiber Bragg gratings at harmonics of the Bragg wavelength through spectra and images
Fiber Bragg gratings written using a phase-mask exhibit a complex refractive index pattern in the fiber core, as observed in differential interference contrast (DIC) microscopy. This results in dual periodicities along the fiber core and gratings at both the Bragg wavelength, twice the Bragg wavelength, and the harmonics of these. Features in grating spectra arise from one or both of these periodicities and spectra for twice the Bragg wavelength (or its odd harmonics) are very sensitive to the details of how the UV complex diffraction field of the phase mask becomes imprinted as refractive index changes in the fiber core.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8421, 84211Z
Understanding fiber Bragg gratings at harmonics of the Bragg wavelength through spectra and images
Fiber Bragg gratings written using a phase-mask exhibit a complex refractive index pattern in the fiber core, as observed in differential interference contrast (DIC) microscopy. This results in dual periodicities along the fiber core and gratings at both the Bragg wavelength, twice the Bragg wavelength, and the harmonics of these. Features in grating spectra arise from one or both of these periodicities and spectra for twice the Bragg wavelength (or its odd harmonics) are very sensitive to the details of how the UV complex diffraction field of the phase mask becomes imprinted as refractive index changes in the fiber core.
- 19 July 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 29 (8) , 1597-1605
Effect of phase mask alignment on fiber Bragg grating spectra at harmonics of the Bragg wavelength
Effects of fabrication conditions on the double-peak structure observed in fiber Bragg gratings at harmonics of the Bragg wavelength were investigated, showing that slight variations in the alignment of the phase mask can affect the grating spectra significantly. A single peak occurs only when the incident beam direction is perfectly normal with respect to the fiber.
- 19 July 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 29 (8) , 1597-1605
Effect of phase mask alignment on fiber Bragg grating spectra at harmonics of the Bragg wavelength
Effects of fabrication conditions on the double-peak structure observed in fiber Bragg gratings at harmonics of the Bragg wavelength were investigated, showing that slight variations in the alignment of the phase mask can affect the grating spectra significantly. A single peak occurs only when the incident beam direction is perfectly normal with respect to the fiber.
- 6 June 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 29 (7) , 1259-1268
Variations of the growth of harmonic reflections in fiber Bragg gratings fabricated using phase masks
The growth of reflectance peaks from optical fiber Bragg gratings has been studied to determine the relative importance of grating features when writing with the phase-mask technique. Measurements of spectra for two different fiber types using two distinct phase masks allowed the contribution from grating features of half the phase-mask periodicity and of the phase-mask periodicity at the Bragg wavelength to be determined. The dominance of the latter periodicity was ascribed to either the small fiber core diameter that limited the extent of the Talbot diffraction pattern, or the enhanced diffraction orders of a custom-made phase mask used.- 6 June 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 29 (7) , 1259-1268
Variations of the growth of harmonic reflections in fiber Bragg gratings fabricated using phase masks
The growth of reflectance peaks from optical fiber Bragg gratings has been studied to determine the relative importance of grating features when writing with the phase-mask technique. Measurements of spectra for two different fiber types using two distinct phase masks allowed the contribution from grating features of half the phase-mask periodicity and of the phase-mask periodicity at the Bragg wavelength to be determined. The dominance of the latter periodicity was ascribed to either the small fiber core diameter that limited the extent of the Talbot diffraction pattern, or the enhanced diffraction orders of a custom-made phase mask used.