Raj Mutharasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raj Mutharasan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Blake N. Johnson
Virginia Tech, United States
5 shared publications David Maraldo
Department of Chemical Engineering, Drexel University, 3141 Chestnut St, Philadelphia, PA 19104, United States
5 shared publicationsSen Xu
Drexel Univ, Dept Chem & Biol Engn, Philadelphia, PA 19104 USA
5 shared publicationsGossett A. Campbell
Department of Chemical Engineering, Drexel University, 31st and Market Sts, Philadelphia, PA 19104, USA
3 shared publications- P. Mohana Shankar
Department of Electrical and Computer Engineering Drexel University Philadelphia Pennsylvania
2 shared publications Andrew J. Detzel
Department of Chemical and Biological Engineering, Drexel University, 32nd and Chestnut Sts, Philadelphia, PA 19104, USA
1 shared publication
Latest Publications
- 24 January 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (7) , 1576-1588
Biosensor-based microRNA detection: techniques, design, performance, and challenges
The current state of biosensor-based techniques for amplification-free microRNA (miRNA) detection is critically reviewed. Comparison with non-sensor and amplification-based molecular techniques (MTs), such as polymerase-based methods, is made in terms of transduction mechanism, associated protocol, and sensitivity. Challenges associated with miRNA hybridization thermodynamics which affect assay selectivity and amplification bias are briefly discussed. Electrochemical, electromechanical, and optical classes of miRNA biosensors are reviewed in terms of transduction mechanism, limit of detection (LOD), time-to-results (TTR), multiplexing potential, and measurement robustness. Current trends suggest that biosensor-based techniques (BTs) for miRNA assay will complement MTs due to the advantages of amplification-free detection, LOD being femtomolar (fM)–attomolar (aM), short TTR, multiplexing capability, and minimal sample preparation requirement. Areas of future importance in miRNA BT development are presented which include focus on achieving high measurement confidence and multiplexing capabilities.
- 24 January 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (7) , 1576-1588
Biosensor-based microRNA detection: techniques, design, performance, and challenges
The current state of biosensor-based techniques for amplification-free microRNA (miRNA) detection is critically reviewed. Comparison with non-sensor and amplification-based molecular techniques (MTs), such as polymerase-based methods, is made in terms of transduction mechanism, associated protocol, and sensitivity. Challenges associated with miRNA hybridization thermodynamics which affect assay selectivity and amplification bias are briefly discussed. Electrochemical, electromechanical, and optical classes of miRNA biosensors are reviewed in terms of transduction mechanism, limit of detection (LOD), time-to-results (TTR), multiplexing potential, and measurement robustness. Current trends suggest that biosensor-based techniques (BTs) for miRNA assay will complement MTs due to the advantages of amplification-free detection, LOD being femtomolar (fM)–attomolar (aM), short TTR, multiplexing capability, and minimal sample preparation requirement. Areas of future importance in miRNA BT development are presented which include focus on achieving high measurement confidence and multiplexing capabilities.
- 6 January 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (5) , 1112-1120
Reduction of nonspecific protein adsorption on cantilever biosensors caused by transverse resonant mode vibration
We examine if vibration of millimeter-sized cantilever sensors can release nonspecifically adsorbed proteins. Integrated electrochemical and mass-change measurement as well as fluorescence assays showed transverse surface vibration released nonspecifically bound proteins in samples prepared at 0.2–3.6 mg bovine serum albumin (BSA) per mL. Extent of release was directly related to magnitude of excitation voltage (Vex) applied to the self-actuating lead zirconate titanate (PZT) cantilever over three log units (0, 10 mV, 100 mV, and 1 V). Vibration-induced release was not instantaneous, but had an apparent first-order rate constant (kapp) which ranged from 0.02–0.1 min−1. Results suggest significant serum albumin protein release could be achieved using excitation voltages of 1 V in millimeter-sized cantilever sensors. Complementary experiments with thiolated DNA, which binds to surface gold 〈111〉 sites with ∼ four times higher binding energy than BSA, showed negligible release under the same vibration magnitude. The results of the study suggest a direct correlation between surface-adsorbate binding energy and the effectiveness of vibration-induced release. We suggest that the release mechanism includes contributions from surface strain energy, body force, and acoustic streaming-associated hydrodynamic effects. The primary contribution of this study suggests that surface vibration of cantilever sensors may be useful in reducing nonspecific adsorption, especially for biosensing of analytes present in a complex background.
- 6 January 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (5) , 1112-1120
Reduction of nonspecific protein adsorption on cantilever biosensors caused by transverse resonant mode vibration
We examine if vibration of millimeter-sized cantilever sensors can release nonspecifically adsorbed proteins. Integrated electrochemical and mass-change measurement as well as fluorescence assays showed transverse surface vibration released nonspecifically bound proteins in samples prepared at 0.2–3.6 mg bovine serum albumin (BSA) per mL. Extent of release was directly related to magnitude of excitation voltage (Vex) applied to the self-actuating lead zirconate titanate (PZT) cantilever over three log units (0, 10 mV, 100 mV, and 1 V). Vibration-induced release was not instantaneous, but had an apparent first-order rate constant (kapp) which ranged from 0.02–0.1 min−1. Results suggest significant serum albumin protein release could be achieved using excitation voltages of 1 V in millimeter-sized cantilever sensors. Complementary experiments with thiolated DNA, which binds to surface gold 〈111〉 sites with ∼ four times higher binding energy than BSA, showed negligible release under the same vibration magnitude. The results of the study suggest a direct correlation between surface-adsorbate binding energy and the effectiveness of vibration-induced release. We suggest that the release mechanism includes contributions from surface strain energy, body force, and acoustic streaming-associated hydrodynamic effects. The primary contribution of this study suggests that surface vibration of cantilever sensors may be useful in reducing nonspecific adsorption, especially for biosensing of analytes present in a complex background.
- 5 September 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (21) , 6365-6371
Electrochemical piezoelectric-excited millimeter-sized cantilever (ePEMC) for simultaneous dual transduction biosensing
A dual mode electrochemical piezoelectric-excited millimeter cantilever (ePEMC) sensor is reported for simultaneous in-liquid biochemical sensing. The ePEMC incorporates mass-sensing measurement of dynamic-mode cantilevers with electrochemical impedance spectroscopy (EIS) commonly employed for transduction in sensitive electrochemical biosensors. Such an integrated design allows for simultaneous and continuous measurement of resonant frequency shift (Δf) and charge transfer resistance (RCT) as a target analyte binds to the sensor gold surface (0.5 mm2) via electromechanical and electrochemical impedance spectroscopy, respectively. The properties of ePEMC are demonstrated in three experiments: (1) resonant frequency response to electrochemically-deposited metal thin-films, (2) resonant frequency response to adsorption of thiolated ssDNA and model proteins with subsequent EIS sensing, and (3) simultaneous resonant frequency and charge transfer resistance response to model chemisorption of a short-chain thiol molecule, mercaptohexanol. Adsorption of all model binding analytes caused decrease in sensor resonant frequency and increase in charge transfer resistance. Comparison of sensor response to binding of protein and thiol molecules showed the two simultaneously transduced signals were proportional and showed the same kinetics.
- 5 September 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (21) , 6365-6371
Electrochemical piezoelectric-excited millimeter-sized cantilever (ePEMC) for simultaneous dual transduction biosensing
A dual mode electrochemical piezoelectric-excited millimeter cantilever (ePEMC) sensor is reported for simultaneous in-liquid biochemical sensing. The ePEMC incorporates mass-sensing measurement of dynamic-mode cantilevers with electrochemical impedance spectroscopy (EIS) commonly employed for transduction in sensitive electrochemical biosensors. Such an integrated design allows for simultaneous and continuous measurement of resonant frequency shift (Δf) and charge transfer resistance (RCT) as a target analyte binds to the sensor gold surface (0.5 mm2) via electromechanical and electrochemical impedance spectroscopy, respectively. The properties of ePEMC are demonstrated in three experiments: (1) resonant frequency response to electrochemically-deposited metal thin-films, (2) resonant frequency response to adsorption of thiolated ssDNA and model proteins with subsequent EIS sensing, and (3) simultaneous resonant frequency and charge transfer resistance response to model chemisorption of a short-chain thiol molecule, mercaptohexanol. Adsorption of all model binding analytes caused decrease in sensor resonant frequency and increase in charge transfer resistance. Comparison of sensor response to binding of protein and thiol molecules showed the two simultaneously transduced signals were proportional and showed the same kinetics.
- 4 March 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (10) , 2943-2950
A method for DNA-based detection of E. coli O157:H7 in a proteinous background using piezoelectric-excited cantilever sensors
We show for the first time the detection of ∼700 E. coli O157:H7 (EC) in both buffer and proteinous sample (beef wash) using the virulent gene stx2 as a sensing molecule immobilized on piezoelectric-excited millimeter cantilever (PEMC) sensors without a sample preparation step. Genomic DNA of EC suspended in buffer or beef wash was extracted using a 30-minute procedure, or using a commercial extraction kit, and then was exposed to the sensor immobilized with a 19-mer probe that is complement to stx2 gene. As hybridization occurred, the resonant frequency of the cantilever sensor decreased due to the increased attached mass indicating the presence of stx2 gene in the sample. Wild strain JM101 subjected to the same preparation and procedure did not induce a hybridization response, nor did the genomic extract of EC with a bare sensor. PEMC sensor responses to diluted genomic extracts indicate that a much lower concentration of 700 cells is detectable. In order to compare the results with antibody-based detection, samples with EC at 2500 cells per mL were exposed to antibody-immobilized PEMC sensors which gave reproducible responses confirming previous experiments with such samples.
- 4 March 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (10) , 2943-2950
A method for DNA-based detection of E. coli O157:H7 in a proteinous background using piezoelectric-excited cantilever sensors
We show for the first time the detection of ∼700 E. coli O157:H7 (EC) in both buffer and proteinous sample (beef wash) using the virulent gene stx2 as a sensing molecule immobilized on piezoelectric-excited millimeter cantilever (PEMC) sensors without a sample preparation step. Genomic DNA of EC suspended in buffer or beef wash was extracted using a 30-minute procedure, or using a commercial extraction kit, and then was exposed to the sensor immobilized with a 19-mer probe that is complement to stx2 gene. As hybridization occurred, the resonant frequency of the cantilever sensor decreased due to the increased attached mass indicating the presence of stx2 gene in the sample. Wild strain JM101 subjected to the same preparation and procedure did not induce a hybridization response, nor did the genomic extract of EC with a bare sensor. PEMC sensor responses to diluted genomic extracts indicate that a much lower concentration of 700 cells is detectable. In order to compare the results with antibody-based detection, samples with EC at 2500 cells per mL were exposed to antibody-immobilized PEMC sensors which gave reproducible responses confirming previous experiments with such samples.
- 1 January 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 176, 1141-1146
Mechanical vibration-assisted modulation of E. coli binding to poly-l-lysine coated biosensor surface
- 1 January 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 176, 1141-1146
Mechanical vibration-assisted modulation of E. coli binding to poly-l-lysine coated biosensor surface
- 19 April 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (17) , 6928-6934
pH Effect on Protein G Orientation on Gold Surfaces and Characterization of Adsorption Thermodynamics
The pH effect on adsorbed antibody-binding protein (protein G) orientation on gold (Au) and its adsorption thermodynamic characteristics were investigated using quartz crystal microbalance (QCM) and X-ray photoelectron spectroscopy (XPS). The adsorbed protein G orientation was measured by binding response of two antibody–antigen systems: the model bovine serum albumin (BSA) and the foodborne pathogen E. coli O157:H7. Surface coverage was not significantly affected by pH, but its orientation was. The most properly oriented protein G for antibody binding was achieved at near-neutral pH. Adsorption was verified by XPS measurements using nitrogen (N) 1s, oxygen (O) 1s, and Au 4p peak heights. Adsorption energetics were determined by van’t Hoff and Langmuir kinetic analyses of adsorption data obtained at 296, 303, and 308 K. Large characteristic entropy change of protein adsorption was observed (ΔS° = 0.52 ± 0.01 kcal/mol·K). The adsorption process was not classical physisorption but exhibited chemisorption characteristics based on significant enthalpy change (ΔH° = −25 ± 6 kcal/mol).
- 19 April 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (17) , 6928-6934
pH Effect on Protein G Orientation on Gold Surfaces and Characterization of Adsorption Thermodynamics
The pH effect on adsorbed antibody-binding protein (protein G) orientation on gold (Au) and its adsorption thermodynamic characteristics were investigated using quartz crystal microbalance (QCM) and X-ray photoelectron spectroscopy (XPS). The adsorbed protein G orientation was measured by binding response of two antibody–antigen systems: the model bovine serum albumin (BSA) and the foodborne pathogen E. coli O157:H7. Surface coverage was not significantly affected by pH, but its orientation was. The most properly oriented protein G for antibody binding was achieved at near-neutral pH. Adsorption was verified by XPS measurements using nitrogen (N) 1s, oxygen (O) 1s, and Au 4p peak heights. Adsorption energetics were determined by van’t Hoff and Langmuir kinetic analyses of adsorption data obtained at 296, 303, and 308 K. Large characteristic entropy change of protein adsorption was observed (ΔS° = 0.52 ± 0.01 kcal/mol·K). The adsorption process was not classical physisorption but exhibited chemisorption characteristics based on significant enthalpy change (ΔH° = −25 ± 6 kcal/mol).
- 11 June 2010
- Published by Elsevier in Analytica Chimica Acta
- Vol. 669 (1-2) , 81-86
Detection of Cryptosporidium parvum in buffer and in complex matrix using PEMC sensors at 5oocystsmL−1
- 11 June 2010
- Published by Elsevier in Analytica Chimica Acta
- Vol. 669 (1-2) , 81-86
Detection of Cryptosporidium parvum in buffer and in complex matrix using PEMC sensors at 5oocystsmL−1
- 4 March 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 145 (1) , 601-604
Impedance change as an alternate measure of resonant frequency shift of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors
- 4 March 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 145 (1) , 601-604
Impedance change as an alternate measure of resonant frequency shift of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors
- 7 January 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 143 (2) , 731-739
Mass-change sensitivity of high-order mode of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors: Theory and experiments
- 7 January 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 143 (2) , 731-739
Mass-change sensitivity of high-order mode of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors: Theory and experiments