Monica Hindsén
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Monica Hindsén has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Lena Persson
Department of Occupational and Environmental Dermatology, Malmö University Hospital, Lund University, Malmö
3 shared publications- Magnus Bruze
Department of Occupational and Environmental Dermatology; Skåne University Hospital, Lund University; SE-205 02 Malmö Sweden
3 shared publications - Erik Zimerson
Department of Occupational and Environmental Dermatology, Malmö University Hospital, Malmö, Sweden
2 shared publications Magnus Bruze
Department of Occupational and Environmental Dermatology, Malmö University Hospital, Lund University, Malmö, Sweden
2 shared publicationsA. Spirén
1 shared publicationBirgitta Gruvberger
1 shared publication
Latest Publications
- 9 July 2012
- Published by Wiley in Contact Dermatitis
- Vol. 67 (2) , 109-111
Variability in patch test reactivity over time, falsely indicating patch test sensitization, in a patient tested with palladium salts
- 9 July 2012
- Published by Wiley in Contact Dermatitis
- Vol. 67 (2) , 109-111
Variability in patch test reactivity over time, falsely indicating patch test sensitization, in a patient tested with palladium salts
- 17 May 2012
- Published by Wiley in Contact Dermatitis
- Vol. 67 (3) , 162-170
Establishing aluminium contact allergy
Background. Traditionally, contact allergy to aluminium has been established by patch testing with aluminium chloride hexahydrate in petrolatum at 2.0% and an empty Finn Chamber®. Objectives. The aim of this study was to investigate different aluminium test preparations regarding an optimal compound and an optimal test concentration. Methods. Six different aluminium compounds and an empty Finn Chamber® were used to patch test 21 patients with aluminium contact allergy. Aluminium chloride hexahydrate in saline was used for intracutaneous injection of 19 patients. Results. One test preparation, aluminium lactate 2.4%, was found to show significantly more positive patch test reactions than aluminium chloride hexahydrate 2.0% (p = 0.03). Aluminium chloride hexahydrate at 10.0% pet. gave the highest number of positive reactions to aluminium [14/21 (67%)]. No positive reactions were noted to an empty Finn Chamber®, and 3 of 19 (16%) patients reacted positively to the intradermal test. Conclusions. The results of this study indicate that patch testing with aluminium chloride hexahydrate 2.0%, with an empty Finn Chamber® and the intradermal test with the salt and doses used are insufficient methods to detect contact allergy to aluminium. Aluminium chloride hexahydrate at 10.0% gave the highest number of positive reactions to aluminium.
- 17 May 2012
- Published by Wiley in Contact Dermatitis
- Vol. 67 (3) , 162-170
Establishing aluminium contact allergy
Background. Traditionally, contact allergy to aluminium has been established by patch testing with aluminium chloride hexahydrate in petrolatum at 2.0% and an empty Finn Chamber®. Objectives. The aim of this study was to investigate different aluminium test preparations regarding an optimal compound and an optimal test concentration. Methods. Six different aluminium compounds and an empty Finn Chamber® were used to patch test 21 patients with aluminium contact allergy. Aluminium chloride hexahydrate in saline was used for intracutaneous injection of 19 patients. Results. One test preparation, aluminium lactate 2.4%, was found to show significantly more positive patch test reactions than aluminium chloride hexahydrate 2.0% (p = 0.03). Aluminium chloride hexahydrate at 10.0% pet. gave the highest number of positive reactions to aluminium [14/21 (67%)]. No positive reactions were noted to an empty Finn Chamber®, and 3 of 19 (16%) patients reacted positively to the intradermal test. Conclusions. The results of this study indicate that patch testing with aluminium chloride hexahydrate 2.0%, with an empty Finn Chamber® and the intradermal test with the salt and doses used are insufficient methods to detect contact allergy to aluminium. Aluminium chloride hexahydrate at 10.0% gave the highest number of positive reactions to aluminium.
- 14 September 2007
- Published by Wiley in Contact Dermatitis
- Vol. 57 (4) , 218-223
Patch testing with thin‐layer chromatograms of chamomile tea in patients allergic to sesquiterpene lactones
Patients with contact allergy to sesquiterpene lactones (SLs) are usually hypersensitive to Asteraceae plant products such as herbal teas. The objective of this study was to show sensitizers in chamomile tea by patch testing with thin-layer chromatograms. Tea made from German chamomile was separated by thin-layer chromatography. Strips of the thin-layer chromatograms were used for patch testing SL-positive patients. 15 (43%) of 35 patients tested positively to 1 or more spots on the thin-layer chromatogram, with many individual reaction patterns. Patch testing with thin-layer chromatograms of German chamomile tea showed the presence of several allergens
- 14 September 2007
- Published by Wiley in Contact Dermatitis
- Vol. 57 (4) , 218-223
Patch testing with thin‐layer chromatograms of chamomile tea in patients allergic to sesquiterpene lactones
Patients with contact allergy to sesquiterpene lactones (SLs) are usually hypersensitive to Asteraceae plant products such as herbal teas. The objective of this study was to show sensitizers in chamomile tea by patch testing with thin-layer chromatograms. Tea made from German chamomile was separated by thin-layer chromatography. Strips of the thin-layer chromatograms were used for patch testing SL-positive patients. 15 (43%) of 35 patients tested positively to 1 or more spots on the thin-layer chromatogram, with many individual reaction patterns. Patch testing with thin-layer chromatograms of German chamomile tea showed the presence of several allergens
- 7 March 2006
- Published by Wiley in Contact Dermatitis
- Vol. 54 (3) , 150-157
Photoallergic contact dermatitis from ketoprofen in southern Sweden
The non‐steroidal anti‐inflammatory drug ketoprofen is widely used for topical treatment. In Sweden, ketoprofen has been available for topical application since 1995. Photoallergic contact dermatitis from ketoprofen‐containing topical preparations usually includes severe eczematous reactions. Ketoprofen is derived from propionic acid, and it is also a substituted benzophenone and therefore structurally similar to fenofibrate and sunscreen agents based on benzophenones. During the last 2 years, 35 patients have been refereed to our department with suspected photoallergic or allergic reactions after having used ketoprofen‐containing gels. Photopatch testing with the photopatch standard series, the ketoprofen‐containing gels and their ingredients, fenofibrate, benzophenone‐3, benzophenone‐10 and benzophenone‐4, was performed. Photoallergic reactions to ketoprofen were noted in 35 patients and a simultaneous contact allergy to ketoprofen in 2 patients. Simultaneous photoallergy to fentichlor, tetrachlorosalicylanilide and fenofibrate was registered in 74%, 40% and 73% of the patients, respectively.
- 7 March 2006
- Published by Wiley in Contact Dermatitis
- Vol. 54 (3) , 150-157
Photoallergic contact dermatitis from ketoprofen in southern Sweden
The non‐steroidal anti‐inflammatory drug ketoprofen is widely used for topical treatment. In Sweden, ketoprofen has been available for topical application since 1995. Photoallergic contact dermatitis from ketoprofen‐containing topical preparations usually includes severe eczematous reactions. Ketoprofen is derived from propionic acid, and it is also a substituted benzophenone and therefore structurally similar to fenofibrate and sunscreen agents based on benzophenones. During the last 2 years, 35 patients have been refereed to our department with suspected photoallergic or allergic reactions after having used ketoprofen‐containing gels. Photopatch testing with the photopatch standard series, the ketoprofen‐containing gels and their ingredients, fenofibrate, benzophenone‐3, benzophenone‐10 and benzophenone‐4, was performed. Photoallergic reactions to ketoprofen were noted in 35 patients and a simultaneous contact allergy to ketoprofen in 2 patients. Simultaneous photoallergy to fentichlor, tetrachlorosalicylanilide and fenofibrate was registered in 74%, 40% and 73% of the patients, respectively.
- 8 December 2005
- Published by Wiley in Contact Dermatitis
- Vol. 53 (6) , 350-351
Allergic contact dermatitis from cobalt in jewellery
- 8 December 2005
- Published by Wiley in Contact Dermatitis
- Vol. 53 (6) , 350-351
Allergic contact dermatitis from cobalt in jewellery
- 10 November 2005
- Published by Wiley in Contact Dermatitis
- Vol. 53 (5) , 301-302
Contact allergy to aluminium in patients hyposensitized with aluminium‐containing hyposensitizing extracts
- 10 November 2005
- Published by Wiley in Contact Dermatitis
- Vol. 53 (5) , 301-302
Contact allergy to aluminium in patients hyposensitized with aluminium‐containing hyposensitizing extracts
- 27 June 2005
- Published by Wiley in Contact Dermatitis
- Vol. 53 (1) , 2-8
Cross‐reactivity between nickel and palladium demonstrated by systemic administration of nickel
Concomitant patch test reactions to nickel and palladium have frequently been reported in patients undergoing investigation because of suspected allergic contact dermatitis. Theoretically, these reactions can be explained by multiple, concomitant, simultaneous sensitization as well as cross‐sensitization. We studied whether concomitant reactions to nickel and palladium could represent cross‐sensitization in females hypersensitive to combinations of nickel, palladium and cobalt. Females were patch tested with serial dilutions of nickel sulfate, cobalt chloride and palladium chloride on the upper back. 1 month later, when the patch test reactions were gone, the patients were randomized into 2 groups that were challenged orally with either nickel or placebo. 1 day later, the areas of previous positive patch test reactions were read in a blind way looking for flare‐up reactions. Nickel provocation but not placebo yielded flare‐up reactions on sites previously tested with nickel (P = 0.012) and palladium (P = 0.006), but were also observed on sites previously tested with cobalt, even though this was not statistically significant. Flare‐up reactions of previous patch test reactions to nickel and palladium after oral challenge with nickel speak in favour of a cross‐reactivity mechanism.
- 27 June 2005
- Published by Wiley in Contact Dermatitis
- Vol. 53 (1) , 2-8
Cross‐reactivity between nickel and palladium demonstrated by systemic administration of nickel
Concomitant patch test reactions to nickel and palladium have frequently been reported in patients undergoing investigation because of suspected allergic contact dermatitis. Theoretically, these reactions can be explained by multiple, concomitant, simultaneous sensitization as well as cross‐sensitization. We studied whether concomitant reactions to nickel and palladium could represent cross‐sensitization in females hypersensitive to combinations of nickel, palladium and cobalt. Females were patch tested with serial dilutions of nickel sulfate, cobalt chloride and palladium chloride on the upper back. 1 month later, when the patch test reactions were gone, the patients were randomized into 2 groups that were challenged orally with either nickel or placebo. 1 day later, the areas of previous positive patch test reactions were read in a blind way looking for flare‐up reactions. Nickel provocation but not placebo yielded flare‐up reactions on sites previously tested with nickel (P = 0.012) and palladium (P = 0.006), but were also observed on sites previously tested with cobalt, even though this was not statistically significant. Flare‐up reactions of previous patch test reactions to nickel and palladium after oral challenge with nickel speak in favour of a cross‐reactivity mechanism.
- 1 March 2004
- Published by Wiley in Contact Dermatitis
- Vol. 50 (3) , 175
FS14.2 Photoallergic contact dermatitis from ketoprofen in Southern Sweden
- 1 March 2004
- Published by Wiley in Contact Dermatitis
- Vol. 50 (3) , 175
FS14.2 Photoallergic contact dermatitis from ketoprofen in Southern Sweden
- 1 February 2004
- Published by Elsevier in Journal of the American Academy of Dermatology
- Vol. 50 (2) , 215-219
Photoallergic contact dermatitis from ketoprofen induced by drug-contaminated personal objects
- 1 February 2004
- Published by Elsevier in Journal of the American Academy of Dermatology
- Vol. 50 (2) , 215-219
Photoallergic contact dermatitis from ketoprofen induced by drug-contaminated personal objects