JFJochen Fuchs

Jochen Fuchs

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jochen Fuchs has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Patients’ X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies

    by Tim-Ole Petersen, Martin Reinhardt, Jochen Fuchs, Dieter Gosch, Alexey Surov, Patrick Stumpp, Thomas Kahn, Michael Moche

    Purpose Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm2 (flat panel detector systems: 155 cGy*cm2; X-ray image intensifier: 175 cGy*cm2). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm2), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT – flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe significantly extends FT, but has little effect on the overall dose of the intervention. Due to the significantly higher X-ray exposure, the use of a CBCT as well as PRG-placements using CT should be limited to clinically absolutely necessary exceptions with strict indication. Key Points Citation Format


  • Open Access

    The value of liver resection for focal nodular hyperplasia: resection yes or no?

    by Hans Michael Hau, Georgi Atanasov, Hans-Michael Tautenhahn, Rudolf Ascherl, Georg Wiltberger, Markus Bo Schoenberg, Mehmet Haluk Morgül, Dirk Uhlmann, Michael Moche, Jochen Fuchs, et al.

    Focal nodular hyperplasia (FNH) are benign lesions in the liver. Although liver resection is generally not indicated in these patients, rare indications for surgical approaches indeed exist. We here report on our single-center experience with patients undergoing liver resection for FNH, focussing on preoperative diagnostic algorithms and quality of life (QoL) after surgery. Medical records of 100 consecutive patients undergoing liver resection for FNH between 1992 and 2012 were retrospectively analyzed with regard to diagnostic pathways and indications for surgery. Quality of life (QoL) before and after surgery was evaluated using validated assessment tools. Student’s t test, one-way ANOVA, χ 2, and binary logistic regression analyses such as Wilcoxon–Mann–Whitney test were used, as indicated. A combination of at least two preoperative diagnostic imaging approaches was applied in 99 cases, of which 70 patients were subjected to further imaging or tumor biopsy. In most patients, there was more than one indication for liver resection, including tumor-associated symptoms with abdominal discomfort (n = 46, 40.7 %), balance of risk for malignancy/history of cancer (n = 54, 47.8 %/n = 18; 33.3 %), tumor enlargement/jaundice of vascular and biliary structures (n = 13, 11.5 %), such as incidental findings during elective operation (n = 1, 0.9 %). Postoperative morbidity was 19 %, with serious complications (>grade 2, Clavien–Dindo classification) being evident in 8 %. Perioperative mortality was 0 %. Liver resection was associated with a significant overall improvement in general health (very good–excellent: preoperatively 47.4 % vs. postoperatively 68.1 %; p = 0.015). Liver resection remains a valuable therapeutic option in the treatment of either symptomatic FNH or if malignancy cannot finally be ruled out. If clinically indicated, liver resection for FNH represents a safe approach and may lead to significant improvements of QoL especially in symptomatic patients.


  • Milzarterienembolisation mittels VascularPlug bei splenic artery steal syndrome (SASS) nach Lebertransplantation

    by J Fuchs, Th Kahn, M Moche

    Ziele: Das splenic artery steal syndrome (SASS) nach Lebertransplantation (LTX) ist gekennzeichnet durch eine arterielle Hypoperfusion der Transplantatleber mit zeitgleicher Hyperperfusion der Milz. Klinische Folgen reichen bis zum Transplantatversagen. Bei der endovaskulären Therapie wird die proximale A. lienalis verschlossen, um den Zufluss zur Leberarterie zu verbessern. Die Coilembolisation ist verhältnismäßig zeitaufwändig und birgt die Gefahr einer Coildislokation mit Milzinfarkten. Es sollte untersucht werden, ob mittels eines ablösbaren Gefäßkörpers ein zuverlässiger, schneller und sicherer Verschluss der proximalen A. lienalis möglich ist. Methode: 15 Milzarterienembolisationen mittels VascularPlug (Amplatzer Plug II und IV) bei Patienten mit SASS nach LTX wurden retrospektiv ausgewertet. Präinterventionell wurde der Durchmesser der A. lienalis anhand einer CT-Untersuchung bestimmt. Nach erneuter Kontrolle des Durchmessers in der DSA erfolgte die Platzierung des passenden Vascular Plug unter Durchleuchtung im proximalen Drittel der A. lienalis. Erst nach abschließender DSA mit Nachweis eines Gefäßverschlusses wurde der Führungskatheter entfernt. Ergebnis: Die Platzierung des VascularPlug war bei allen 15 Patienten technisch erfolgreich. Der mittlere Gefäßdurchmesser der A. lienalis lag bei 7,4mm. Die verwendeten Plugs reichten von 6mm bis 16mm Durchmesser (Mittel 10,5mm). Die durchschnittliche Zeit von der Entfaltung des Plugs bis zum Gefäßverschluss betrug 9,6min. Bei einem Patienten dislozierte der Plug in das distale Drittel der A. lienalis, ohne dass sich in der Kontrollbildgebung ein Milzinfarkt nachweisen ließ. Das Verhältnis zwischen Plugdurchmesser zu Gefäßdurchmesser betrug im Mittel 1,43. Schlussfolgerung: Die Embolisation der A. lienalis bei Patienten mit einem arteriellem Steal-Syndrom (SASS) nach Lebertransplantation und dadurch bedingtem hohem Fluss in der A. lienalis kann mittels eines mind. 40–50% überdimensionierten VascularPlug sicher und zuverlässig durchgeführt werden. Keywords: splenic artery steal syndrome, Lebertransplantation, Milzarterienembolisation, VascularPlug, SASS Korrespondierender Autor: Fuchs J Universitätsklinikum Leipzig, Klinik für Diagnostische und Interventionelle Radiologie, Liebigstr. 20, 04103 Leipzig E-Mail: jochen.fuchs@medizin.uni-leipzig.de