DHDariusch R. Hadizadeh

Dariusch R. Hadizadeh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dariusch R. Hadizadeh has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Abdominal vasculature in dynamic contrast-enhanced liver MRI at 3.0 T: an intraindividual comparative study using gadoxetate disodium and gadofosveset trisodium

    by Patrick A. Kupczyk, Winfried A. Willinek, Dariusch R. Hadizadeh, Frank Traeber, Juergen Gieseke, Carsten Meyer, Hans H. Schild, Guido M. Kukuk

  • Open Access

    0.125 mm3 spatial resolution steady‐state MR angiography of the thighs with a blood pool contrast agent using the quadrature body coil only at 1.5 Tesla

    by Jack M. Boschewitz, Dariusch R. Hadizadeh, Guido M. Kukuk, Carsten Meyer, Kai Wilhelm, Arne Koscielny, Frauke Verrel, Jürgen Gieseke, Hans H. Schild, Winfried A. Willinek

    Purpose To implement and evaluate high spatial resolution three-dimensional MR contrast-enhanced angiography (3D-CEMRA) of the thighs using a blood pool contrast agent (BPCA) using the quadrature body coil only in patients with peripheral arterial occlusive disease (PAOD) in cases receiver coils cannot be used at 1.5 Tesla (T). Materials and Methods Nineteen patients (mean age: 68.7 ± 11.2 years; range, 38–83 years) with known PAOD (Fontaine stages; III: 16, IV: 3) prospectively underwent 3D-CEMRA at 1.5T with a noninterpolated voxel size of 0.49 × 0.49 × 0.48 mm3. Digital subtraction angiography (DSA) was available for comparison in all patients. Two readers independently evaluated movement artifacts, overall image quality of 3D-CEMRA, and grade of stenosis as compared to DSA. SNR and CNR levels were quantified. Results The 3D-CEMRA was successfully completed in all patients. Patient movement artifacts that affected stenosis grading occurred in 3/38 thighs. Overall image quality was rated excellent in 15/38, good in 12/38, and diagnostic in 8/38 thighs. Stenosis grading matched with that in DSA in 35/38 thighs. High SNR and CNR were measured in all vessels. Conclusion The 0.125 mm3 spatial resolution 3D-CEMRA of the thighs with a BPCA is feasible using a quadrature body coil exclusively with excellent image quality despite long acquisition times. J. Magn. Reson. Imaging 2014;40:996–1001.


  • Open Access

    Magnetic resonance spectroscopic study of radiogenic changes after radiosurgery of cerebral arteriovenous malformations with implications for the differential diagnosis of radionecrosis

    by Jan Boström, Dariusch R Hadizadeh, Wolfgang Block, Winfried Willinek, Hans H Schild, Frank Träber

    The incidence of radionecrosis after radiosurgery is 5–20%. That radionecrosis after radiosurgery may be confused with a malignant tumor is a known phenomenon and problem.


  • Simultaneous MR Arteriography and Venography With Blood Pool Contrast Agent Detects Deep Venous Thrombosis in Suspected Arterial Disease

    by Dariusch R. Hadizadeh, Guido M. Kukuk, Ute L. Fahlenkamp, Josephine Pressacco, Christian Schäfer, Eberhard Rabe, Arne Koscielny, Frauke Verrel, Hans H. Schild, Winfried A. Willinek

    OBJECTIVE. The purpose of this study was to investigate the prevalence of incidental deep venous thrombosis (DVT) in patients with clinically suspected peripheral arterial occlusive disease (PAOD) using contrast-enhanced MR angiography (MRA) with a blood pool contrast agent. SUBJECTS AND METHODS. Two hundred fifty-nine MRA examinations with blood pool contrast agent in 245 consecutive patients (161 men; age range, 36–92 years), yielding a total of 4102 assessable arterial and venous vessel segments, were assessed with regard to the rate of incidentally observed acute and organized DVT and arterial stenosis grades. Incidental DVT was confirmed using duplex ultrasound. Contralateral nondiseased veins served as internal controls. The relationship between PAOD stages and acute and organized DVT was investigated using chi-square tests and a Mann-Whitney U test. RESULTS. Arterial stenosis grading using MRA with blood pool contrast agent revealed less than 50% luminal stenosis in 78% of segments (3199/4102), 50%...


  • Open Access

    Noninvasive Evaluation of Cerebral Arteriovenous Malformations by 4D-MRA for Preoperative Planning and Postoperative Follow-Up in 56 Patients: Comparison with DSA and Intraoperative Findings

    by D.R. Hadizadeh, G.M. Kukuk, D.T. Steck, J. Gieseke, H. Urbach, H.J. Tschampa, S. Greschus, A. Kovàcs, M. Möhlenbruch, A. Bostroem, et al.

    BACKGROUND AND PURPOSE: 4D-MRA is a promising technique in the diagnosis and follow-up of cAVMs. The purpose of this study was to compare 4D-MRA in the pre- and postoperative evaluation of cAVMs with DSA or intraoperative findings as the standards of reference regarding qualitative and quantitative parameters. MATERIALS AND METHODS: Fifty-six consecutive patients with cAVMs (30 women) underwent both 4D-MRA and DSA. Preoperative 4D-MRA was excluded from analysis in 1 patient (movement artifacts). Twenty-five patients underwent surgery on cAVMs and underwent both imaging modalities pre- and postoperatively. 4D-MRA was performed with either 0.5-mol/L gadolinium-diethylene-triamine pentaacetic acid (group 1: voxel size, 1.1 × 1.1 × 1.4 mm3; 608 ms/dynamic frame; 19 patients) or 1.0-mol/L gadobutrol (group 2: voxel size, 1.1 × 1.1 × 1.1 mm3; 572 ms/dynamic frame; additional alternating view sharing; 37 patients). Two readers independently reviewed 4D-MRA and DSA regarding the Spetzler-Martin classification, arterial feeders, and postoperative residual filling. Vessel sharpness, vessel diameter, and VBC of 4D-MRA were quantified. RESULTS: Preoperative Spetzler-Martin classification 4D-MRA and DSA ratings matched in 55/55 patients (Spetzler-Martin grades: I, 12; II, 22; III, 15; IV, 5; V, 1), and 93/100 arterial feeders were correctly identified by preoperative 4D-MRA (7 additional arterial feeders identified by DSA only: group 1, 3/19; group 2, 4/36). Postoperative 4D-MRA and DSA matched in 25/25 patients (residual filling, 1/25). Vessel sharpness and diameters did not differ substantially between the 2 groups. VBC was significantly higher in group 2 (P < .005). CONCLUSIONS: 4D-MRA is a reliable tool that allows predicting Spetzler-Martin classification and postoperative residual filling; it hence allows substituting DSA in the pre- and postoperative evaluation of patients with cerebral AVMs.


  • View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0T

    by Dariusch R. Hadizadeh, Jürgen Gieseke, Gabriele Beck, Liesbeth Geerts, Guido M. Kukuk, Azize Boström, Horst Urbach, Hans H. Schild, Winfried A. Willinek


  • Intracranial Arterial and Venous Disease

    by Dariusch R. Hadizadeh, Horst Urbach, Winfried A. Willinek

  • Periphere MR-Angiographie mit einem Blood-Pool-Kontrastmittel: Inzidenz venöser Thrombosen bei Patienten mit pAVK

    by Hadizadeh, Gm Kukuk, Ul Fahlenkamp, J Gieseke, C Schäfer, E Rabe, A Koscielny, F Verrel, Hh Schild, W Willinek

    Ziele: Die räumlich hochaufgelöste MR-Angiographie in der Äquilibriumphase eines Blood-Pool-Kontrastmittels (SSMRA) führt zu einer Konstrastierung sowohl von arteriellen und als auch venösen Gefäßen. Ziel dieser Studie war die Ermittlung der Inzidenz venöser Thrombosen als Zufallsbefund bei der Abklärung einer klinisch vermuteten peripheren arteriellen Verschlusskrankheit (pAVK). Methode: Die SSMRA wurde bei 245 Patienten (Alter: 36–92 Jahre; 161männlich, 84 weiblich; 259 Untersuchungen bei Wiedervorstellung von 14 Patienten im Untersuchungszeitraum) durchgeführt. Je 4102 arterielle und venöse Gefäßsegmente wurden in Hinblick auf den arteriellen Stenosegrad und das Vorliegen venöser Thromben analysiert. Die Untersuchungen wurden an einem 1,5 T Ganzkörper-MR-Tomographen (Achieva, Philips Healthcare, Niederlande) durchgeführt. Die SSMRA wurde im Oberschenkel mittels der integrierten Körperspule mit einer räumlichen Auflösung von (0,88×0,88×0,99)mm3 und im Unterschenkel mit einer flexiblen 4-Kanal-Oberflächenspule und einer räumlichen Auflösung von (0,52×0,52×0,49)mm3 akquiriert. Venöse Thrombosen wurden mit Doppler-Ultraschalluntersuchungen korreliert und unauffällige Gefäße der Gegenseite dienten als interne Kontrollen. Ergebnis: Die SSMRA zeigte bei 3199/4102 arteriellen Segmenten (78%) keine signifikante Stenose (50%) und 586 verschlossene Gefäßsegmente (14%). Bei 10% der Patienten wurden venöse Thromben (10 Patienten: akute Thrombosen, 17 Patienten: chronische Thrombosen) diagnostiziert und mittels Doppler-Ultraschalluntersuchung bestätigt. 172 Kontrollsegmente zeigten in der SSMRA und sonographisch keinen auffälligen Befund. Schlussfolgerung: Die räumlich hochaufgelöste MR-Angiographie mit einem Blood-Pool-Kontrastmittel eignet sich zur gleichzeitigen arteriellen und venösen Diagnostik. Die Inzidenz inzidenteller Thrombosen bei Patienten mit vermuteter pAVK betrug 10%. Keywords: Blood-Pool-KM, Venenthrombose, pAVK, MRA Korrespondierender Autor: Hadizadeh DR Radiologische Universitätsklinik Bonn, Sigmund-Freud Str. 25, 53127 Bonn E-Mail: Dariusch.Hadizadeh@ukb.uni-bonn.de

  • Keyhole- und ViewSharing-Techniken zur Akquisition zeitlich und räumlich hochaufgelöster 4D MR Angiographie im Vergleich zur DSA bei 43 Patienten mit zerebralen arteriovenösen Malformationen

    by Hadizadeh, Gm Kukuk, J Gieseke, H Tschampa, A Kovács, H Urbach, A Bostroem, H Schild, Wa Willinek

    Ziele: Die zeitlich hochaufgelöste 4DMRA ist eine vielversprechende Technik zur nicht-invasiven Diagnostik und Verlaufskontrolle zerebraler arteriovenöser Malformationen (zAVM). Mögliche Limitationen der 4DMRA bestehen in der zeitlichen und räumlichen Auflösung im Vergleich zur Referenzmethode, DSA. Das Ziel dieser Studie war die Analyse von zeitlich und räumlich hochaufgelösten 4DMRA-Techniken bei der prä- und postoperativen Diagnostik von zAVM im Vergleich zur DSA. Methode: Bei 43 Patienten mit zAVM (24 weiblich, 19männlich; Alter: 39,3±13,5 (17–69) Jahre) wurden je 50 aufeinanderfolgende 4DMRA 3D-Datensätze unter Nutzung partieller k-Raum-Akquisitionstechniken (CENTRA-Keyhole, partielle Fourier-Bildgebung, parallele Bildgebung und alternierendes ViewSharing, 3,0 Tesla Philips Achieva Ganzkörper-MRT) mit zeitlichen Auflösungen von 572–608ms und räumlichen Auflösungen von 1,1×1,1–1,4×1,1mm3 akquiriert. Alle Patienten erhielten DSA-Untersuchungen. 16/43 Patienten erhielten sowohl prä- als auch postoperativ beide Untersuchungsmodalitäten. Die Untersuchungen wurden durch zwei Untersucher unabhängig voneinander hinsichtlich der Spetzler-Martin Klassifikation, der arteriellen Versorgungsgefäße und der postoperativen Ausschaltung des zAVM ausgewertet. Ergebnis: Bei 43/43 Patienten stimmte die Spetzler-Martin-Klassifikationen der zAVM mittels 4DMRA und DSA überein. Die Evaluation hinsichtlich eines postoperativen zAVM-Residuums ergab bei 16/16 Patienten übereinstimmende Ergebnisse. Eine vollständige Ausschaltung des zAVM wurde bei 15/16 Patienten nachgewiesen, während bei einem Patienten eine residuale post-operative zAVM-Füllung mit beiden Methoden nachgewiesen werden konnte. Schlussfolgerung: Die räumlich und zeitlich hochaufgelöste 4DMRA ermöglicht im Vergleich zur DSA eine korrekte prä-operative Spetzler-Martin-Klassifikation und post-operative Beurteilung hinsichtlich residusler Nidusfüllung und bietet somit eine vielversprechende nicht-invasive Alternative in der Diagnostik und Verlaufskontrolle von zAVM. Korrespondierender Autor: Hadizadeh DR Univiersitätskliniken Bonn, Radiologie, Sigmund-Freud Str. 25, 53127 Bonn E-Mail: Dariusch.Hadizadeh@ukb.uni-bonn.de