Nicholas Watkins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicholas Watkins has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Cynthia Padula
2 shared publicationsErin Peavey
2 shared publicationsMary Kennedy
2 shared publicationsStephen Thomas
NHS Blood and Transplant (NHSBT), Watford, UK
2 shared publicationsDonald Myers
1 shared publicationDouglas Dixon
Microbiology Services Division, Public Health England, Salisbury, UK
1 shared publication
Latest Publications
- 30 May 2015
- Published by Wiley in Transfusion
- Vol. 55 (10) , 2390-2397
Evaluation of efficacy of prion reduction filters using blood from an endogenously infected 263K scrapie hamster model
The P-Capt prion reduction filter (MacoPharma) removes prion infectivity in model systems. This independent evaluation assesses prion removal from endogenously infected animal blood, using CE-marked P-Capt filters, and replicates the proposed use of the filter within the UK Blood Services. Two units of blood, generated from 263K scrapie-infected hamsters, were processed using leukoreduction filters (LXT-quadruple, MacoPharma). Approximately 100 mL of the removed plasma was added back to the red blood cells (RBCs) and the blood was filtered through a P-Capt filter. Samples of unfiltered whole blood, the prion filter input (RBCs plus plasma and SAGM [RBCPS]), and prion-filtered leukoreduced blood (PFB) were injected intracranially into hamsters. Clinical symptoms were monitored for 500 ± 1 day, and brains were assessed for spongiosis and prion protein deposit. In Filtration Run 1, none of the 50 challenged animals were diagnosed with scrapie after inoculation with the RBCPS fraction, while two of 190 hamsters injected with PFB were infected. In Filtration Run 2, one of 49 animals injected with RBCPS and two of 193 hamsters injected with PFB were infected. Run 1 reduced the infectious dose (ID) by 1.467 log (>1.187 log and <0.280 log for leukoreduction and prion filtration, respectively). Run 2 reduced prion infectivity by 1.424 log (1.127 and 0.297 log, respectively). Residual infectivity was estimated at 0.212 ± 0.149 IDs/mL (Run 1) and 0.208 ± 0.147 IDs/mL (Run 2). Leukoreduction removed the majority of infectivity from 263K scrapie hamster blood. The P-Capt filter removed a proportion of the remaining infectivity, but residual infectivity was observed in two independent processes.
- 30 May 2015
- Published by Wiley in Transfusion
- Vol. 55 (10) , 2390-2397
Evaluation of efficacy of prion reduction filters using blood from an endogenously infected 263K scrapie hamster model
The P-Capt prion reduction filter (MacoPharma) removes prion infectivity in model systems. This independent evaluation assesses prion removal from endogenously infected animal blood, using CE-marked P-Capt filters, and replicates the proposed use of the filter within the UK Blood Services. Two units of blood, generated from 263K scrapie-infected hamsters, were processed using leukoreduction filters (LXT-quadruple, MacoPharma). Approximately 100 mL of the removed plasma was added back to the red blood cells (RBCs) and the blood was filtered through a P-Capt filter. Samples of unfiltered whole blood, the prion filter input (RBCs plus plasma and SAGM [RBCPS]), and prion-filtered leukoreduced blood (PFB) were injected intracranially into hamsters. Clinical symptoms were monitored for 500 ± 1 day, and brains were assessed for spongiosis and prion protein deposit. In Filtration Run 1, none of the 50 challenged animals were diagnosed with scrapie after inoculation with the RBCPS fraction, while two of 190 hamsters injected with PFB were infected. In Filtration Run 2, one of 49 animals injected with RBCPS and two of 193 hamsters injected with PFB were infected. Run 1 reduced the infectious dose (ID) by 1.467 log (>1.187 log and <0.280 log for leukoreduction and prion filtration, respectively). Run 2 reduced prion infectivity by 1.424 log (1.127 and 0.297 log, respectively). Residual infectivity was estimated at 0.212 ± 0.149 IDs/mL (Run 1) and 0.208 ± 0.147 IDs/mL (Run 2). Leukoreduction removed the majority of infectivity from 263K scrapie hamster blood. The P-Capt filter removed a proportion of the remaining infectivity, but residual infectivity was observed in two independent processes.
- 1 May 2012
- Published by Wolters Kluwer Health in JONA: The Journal of Nursing Administration
- Vol. 42 (5) , 256-265
Destination Bedside
This study explored the impact of unit design and healthcare information technology (HIT) on nursing workflow and patient-centered care (PCC). Healthcare information technology and unit layout-related predictors of nursing workflow and PCC were measured during a 3-phase study involving questionnaires and work sampling methods. Stepwise multiple linear regressions demonstrated several HIT and unit layout-related factors that impact nursing workflow and PCC.
- 1 May 2012
- Published by Wolters Kluwer Health in JONA: The Journal of Nursing Administration
- Vol. 42 (5) , 256-265
Destination Bedside
This study explored the impact of unit design and healthcare information technology (HIT) on nursing workflow and patient-centered care (PCC). Healthcare information technology and unit layout-related predictors of nursing workflow and PCC were measured during a 3-phase study involving questionnaires and work sampling methods. Stepwise multiple linear regressions demonstrated several HIT and unit layout-related factors that impact nursing workflow and PCC.
- 1 October 2011
- Published by SAGE Publications in HERD: Health Environments Research & Design Journal
- Vol. 5 (1) , 6-22
An Evaluation of Operating Room Safety and Efficiency: Pilot Utilization of a Structured Focus Group Format and Three-Dimensional Video Mock-Up to Inform Design Decision Making
Objective: The purpose of this investigation was to identify safety and efficiency-related design features for inclusion in operating room (OR) construction documents. Background: Organizations are confronted with an array of challenges when planning an OR, including inefficiencies in operations, adverse events, and a variety of innovations to choose from. Currently, techniques that can be used in design practice and to inform design decision making for implementable OR solutions are limited. Methods: The project team used a structured focus group format with mixed methods to solicit 19 varying surgical team members' reactions to a three-dimensional video mock-up of a proposed OR. Data from the 19 participants were analyzed using stepwise multiple regression and content analysis of open-ended responses. Results and Discussion: Results demonstrate that several features of the proposed OR design predict meaningful outcomes, including flexibility and satisfaction with the OR setup, adverse event prevention, team performance, and distractions and interruptions. Participants' suggested solutions include universal booms to support anesthetic and perfusion capabilities, a fixed circulating nursing workstation that faces the patient and is at the foot of the operating room table, a wall-mounted monitor across from the surgeon, and wiring to support a touch-screen control arm in OR surgical fields. Conclusions: Findings from structured focus groups with mixed methods lead to implementable design solutions for construction documentation. The expeditious qualities and objectivity of the format are value-adds to the design decision-making process. Future research should use various techniques such as virtual technologies and building information modeling.
- 1 October 2011
- Published by SAGE Publications in HERD: Health Environments Research & Design Journal
- Vol. 5 (1) , 6-22
An Evaluation of Operating Room Safety and Efficiency: Pilot Utilization of a Structured Focus Group Format and Three-Dimensional Video Mock-Up to Inform Design Decision Making
Objective: The purpose of this investigation was to identify safety and efficiency-related design features for inclusion in operating room (OR) construction documents. Background: Organizations are confronted with an array of challenges when planning an OR, including inefficiencies in operations, adverse events, and a variety of innovations to choose from. Currently, techniques that can be used in design practice and to inform design decision making for implementable OR solutions are limited. Methods: The project team used a structured focus group format with mixed methods to solicit 19 varying surgical team members' reactions to a three-dimensional video mock-up of a proposed OR. Data from the 19 participants were analyzed using stepwise multiple regression and content analysis of open-ended responses. Results and Discussion: Results demonstrate that several features of the proposed OR design predict meaningful outcomes, including flexibility and satisfaction with the OR setup, adverse event prevention, team performance, and distractions and interruptions. Participants' suggested solutions include universal booms to support anesthetic and perfusion capabilities, a fixed circulating nursing workstation that faces the patient and is at the foot of the operating room table, a wall-mounted monitor across from the surgeon, and wiring to support a touch-screen control arm in OR surgical fields. Conclusions: Findings from structured focus groups with mixed methods lead to implementable design solutions for construction documentation. The expeditious qualities and objectivity of the format are value-adds to the design decision-making process. Future research should use various techniques such as virtual technologies and building information modeling.
- 1 June 2011
- Published by Wolters Kluwer Health in JONA: The Journal of Nursing Administration
- Vol. 41 (6) , 273-279
Same-Handed and Mirrored Unit Configurations
Despite growing awareness that hospital design can impact meaningful outcomes, the same-handed medical-surgical inpatient unit configuration has not been empirically investigated. This study measured differences in patient and nurse outcomes between the same-handed and mirrored unit configurations. It has been hypothesized that the same-handed unit configuration may contribute to operational efficiencies, fewer adverse events, and reduced noise levels. A natural experiment of 8 medical-surgical inpatient units used 2 questionnaires developed for the study. The first questionnaire was available to registered nurses. The second was available to the nurses' patients. Compared with participants on the mirrored unit configuration, participants on the same-handed unit configuration reported lower noise levels, better sleep quality, more frequent approaches to patients' right side, and improved satisfaction with organization of the workspace at patients' bedsides. The increased right-side approach was related to fewer instances of patients catching themselves from falling. The same-handed unit configuration benefits patient experience, patient safety, and operational outcomes. Before renovation or new construction of units, nurse executives should consider the advantages of a same-handed unit configuration.
- 1 June 2011
- Published by Wolters Kluwer Health in JONA: The Journal of Nursing Administration
- Vol. 41 (6) , 273-279
Same-Handed and Mirrored Unit Configurations
Despite growing awareness that hospital design can impact meaningful outcomes, the same-handed medical-surgical inpatient unit configuration has not been empirically investigated. This study measured differences in patient and nurse outcomes between the same-handed and mirrored unit configurations. It has been hypothesized that the same-handed unit configuration may contribute to operational efficiencies, fewer adverse events, and reduced noise levels. A natural experiment of 8 medical-surgical inpatient units used 2 questionnaires developed for the study. The first questionnaire was available to registered nurses. The second was available to the nurses' patients. Compared with participants on the mirrored unit configuration, participants on the same-handed unit configuration reported lower noise levels, better sleep quality, more frequent approaches to patients' right side, and improved satisfaction with organization of the workspace at patients' bedsides. The increased right-side approach was related to fewer instances of patients catching themselves from falling. The same-handed unit configuration benefits patient experience, patient safety, and operational outcomes. Before renovation or new construction of units, nurse executives should consider the advantages of a same-handed unit configuration.
- 1 October 2008
- Published by SAGE Publications in HERD: Health Environments Research & Design Journal
- Vol. 2 (1) , 66-81
Mock-Ups as “Interactive Laboratories”: Mixed Methods Research Using Inpatient Unit Room Mock-Ups
Objective: To establish evidence-based design (EBD) guidelines for inpatient rooms at Department of Veterans Affairs (VA) facilities. Background: Simulation allows clients, designers, and researchers to visualize how users might interact with a proposed design before actual construction of the design. This study used mock-ups as a simulation technique during a study of the VA inpatient room standards. The participants used the inpatient room mock-ups as “interactive laboratory” environments to maximize opportunities for participatory design, qualitative research, and quantitative research of project-specific EBD solutions. Methods: The research used questionnaires, scenarios, on-demand modifications, and observations to evaluate and confirm EBD solutions for inpatient room mock-ups. A total of 71 participants responded to a questionnaire administered across five mock-up work sessions. These 71 participants consisted of administrators, nurses, physicians, support staff, environment and maintenance staff, and patient and staff safety representatives from throughout the VA healthcare system. Results and Discussion: EBD solutions were tested, evaluated, and modified for each inpatient room type and were applicable to two or more of the inpatient room types. The latter included the location of patient beds and standard headwall position, technology and spaces for nurse charting activities, clearances (e.g., equipment, wheelchair, and bariatric patient), universal rooms, and patient and family amenities. Also, EBD solutions were tested, validated, and modified to the needs of each inpatient room. Conclusion: The mock-ups allowed researchers and designers to evaluate and confirm EBD solutions and strategies for the development of VA inpatient room standards. When used as a means for mixed-methods research, mock-ups can successfully integrate research and design during project-related work. EBD research using mock-ups not only addresses project- or organization-specific concerns, but it may contribute to the knowledge base of the healthcare design community.
- 1 October 2008
- Published by SAGE Publications in HERD: Health Environments Research & Design Journal
- Vol. 2 (1) , 66-81
Mock-Ups as “Interactive Laboratories”: Mixed Methods Research Using Inpatient Unit Room Mock-Ups
Objective: To establish evidence-based design (EBD) guidelines for inpatient rooms at Department of Veterans Affairs (VA) facilities. Background: Simulation allows clients, designers, and researchers to visualize how users might interact with a proposed design before actual construction of the design. This study used mock-ups as a simulation technique during a study of the VA inpatient room standards. The participants used the inpatient room mock-ups as “interactive laboratory” environments to maximize opportunities for participatory design, qualitative research, and quantitative research of project-specific EBD solutions. Methods: The research used questionnaires, scenarios, on-demand modifications, and observations to evaluate and confirm EBD solutions for inpatient room mock-ups. A total of 71 participants responded to a questionnaire administered across five mock-up work sessions. These 71 participants consisted of administrators, nurses, physicians, support staff, environment and maintenance staff, and patient and staff safety representatives from throughout the VA healthcare system. Results and Discussion: EBD solutions were tested, evaluated, and modified for each inpatient room type and were applicable to two or more of the inpatient room types. The latter included the location of patient beds and standard headwall position, technology and spaces for nurse charting activities, clearances (e.g., equipment, wheelchair, and bariatric patient), universal rooms, and patient and family amenities. Also, EBD solutions were tested, validated, and modified to the needs of each inpatient room. Conclusion: The mock-ups allowed researchers and designers to evaluate and confirm EBD solutions and strategies for the development of VA inpatient room standards. When used as a means for mixed-methods research, mock-ups can successfully integrate research and design during project-related work. EBD research using mock-ups not only addresses project- or organization-specific concerns, but it may contribute to the knowledge base of the healthcare design community.