Yijun Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yijun Huang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Ronald P. Danis
Fundus Photograph Reading Center, Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
3 shared publicationsAshwini Narkar
Fundus Photograph Reading Center, Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
2 shared publicationsJeong W. Pak
Fundus Photograph Reading Center, Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
2 shared publications- Ronald Klein
Department of Ophthalmology and Visual Sciences, University of Wisconsin-Madison, Madison, Wisconsin
2 shared publications Sapna Gangaputra
Fundus Photograph Reading Center, Department of Ophthalmology and Visual Sciences, University of Wisconsin–Madison, Madison, Wisconsin
2 shared publications- Amitha Domalpally
A-EYE Research Unit, Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, Wisconsin
1 shared publication
Latest Publications
- Open Access
- 26 December 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (12) , e82922
Development of a Semi-Automatic Segmentation Method for Retinal OCT Images Tested in Patients with Diabetic Macular Edema
To develop EdgeSelect, a semi-automatic method for the segmentation of retinal layers in spectral domain optical coherence tomography images, and to compare the segmentation results with a manual method. SD-OCT (Heidelberg Spectralis) scans of 28 eyes (24 patients with diabetic macular edema and 4 normal subjects) were imported into a customized MATLAB application, and were manually segmented by three graders at the layers corresponding to the inner limiting membrane (ILM), the inner segment/ellipsoid interface (ISe), the retinal/retinal pigment epithelium interface (RPE), and the Bruch's membrane (BM). The scans were then segmented independently by the same graders using EdgeSelect, a semi-automated method allowing the graders to guide/correct the layer segmentation interactively. The inter-grader reproducibility and agreement in locating the layer positions between the manual and EdgeSelect methods were assessed and compared using the Wilcoxon signed rank test. The inter-grader reproducibility using the EdgeSelect method for retinal layers varied from 0.15 to 1.21 µm, smaller than those using the manual method (3.36–6.43 µm). The Wilcoxon test indicated the EdgeSelect method had significantly better reproducibility than the manual method. The agreement between the manual and EdgeSelect methods in locating retinal layers ranged from 0.08 to 1.32 µm. There were small differences between the two methods in locating the ILM (p = 0.012) and BM layers (p<0.001), but these were statistically indistinguishable in locating the ISe (p = 0.896) and RPE layers (p = 0.771). The EdgeSelect method resulted in better reproducibility and good agreement with a manual method in a set of eyes of normal subjects and with retinal disease, suggesting that this approach is feasible for OCT image analysis in clinical trials.
- 26 December 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (12) , e82922
Open AccessDevelopment of a Semi-Automatic Segmentation Method for Retinal OCT Images Tested in Patients with Diabetic Macular Edema
To develop EdgeSelect, a semi-automatic method for the segmentation of retinal layers in spectral domain optical coherence tomography images, and to compare the segmentation results with a manual method. SD-OCT (Heidelberg Spectralis) scans of 28 eyes (24 patients with diabetic macular edema and 4 normal subjects) were imported into a customized MATLAB application, and were manually segmented by three graders at the layers corresponding to the inner limiting membrane (ILM), the inner segment/ellipsoid interface (ISe), the retinal/retinal pigment epithelium interface (RPE), and the Bruch's membrane (BM). The scans were then segmented independently by the same graders using EdgeSelect, a semi-automated method allowing the graders to guide/correct the layer segmentation interactively. The inter-grader reproducibility and agreement in locating the layer positions between the manual and EdgeSelect methods were assessed and compared using the Wilcoxon signed rank test. The inter-grader reproducibility using the EdgeSelect method for retinal layers varied from 0.15 to 1.21 µm, smaller than those using the manual method (3.36–6.43 µm). The Wilcoxon test indicated the EdgeSelect method had significantly better reproducibility than the manual method. The agreement between the manual and EdgeSelect methods in locating retinal layers ranged from 0.08 to 1.32 µm. There were small differences between the two methods in locating the ILM (p = 0.012) and BM layers (p<0.001), but these were statistically indistinguishable in locating the ISe (p = 0.896) and RPE layers (p = 0.771). The EdgeSelect method resulted in better reproducibility and good agreement with a manual method in a set of eyes of normal subjects and with retinal disease, suggesting that this approach is feasible for OCT image analysis in clinical trials.
- Open Access
- 1 July 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (7) , 4512-4518
Effect of Optical Coherence Tomography Scan Decentration on Macular Center Subfield Thickness Measurements
Purpose.: To investigate the effect of optical coherence tomography macular grid displacement on retinal thickness measurements. Methods.: SD-OCT macular scans of 66 eyes with various retinal thicknesses were selected. Decentration of the 1-, 3-, 6-mm-diameter macular grid was simulated by manually adjusting the distance between center of the fovea (cFovea) and center of the grid (cGrid). Center subfield thickness (CSF) between the internal limiting membrane and the top of the retinal pigment epithelium was measured along the displacement distance where the grid was displaced in eight cardinal directions from the cFovea in steps of 100 μm within the central 1-mm subfield and then by 200 μm within the inner subfields. One-way/mixed-effects repeated-measures ANOVA models were used to determine changes of CSF (ΔCSF) as a function of displacement distance (for α = 0.05, power = 0.80 and effect size = 0.1). The interactions between the displacement distance and direction, center point thickness (CPT), and foveal contour were also analyzed. Results.: The CSF measurement showed statistically significant error when the displacement distance between cFovea and cGrid exceeded 200 μm. The direction of displacement did not affect the ΔCSF-distance relationship, while the CPT and foveal contour significantly affected the relationship, in that some subgroups showed slightly larger tolerance in the displacement distance up to 300 μm before reaching significant ΔCSF. Conclusions.: Small displacement distances of the macular grid from the cFovea affect CSF measurements throughout a broad range of thicknesses and retinal contour alterations from disease. Accurate registration of OCT scans or post hoc repositioning of the grid is essential to optimize CSF accuracy.
- 1 July 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (7) , 4512-4518
Open AccessEffect of Optical Coherence Tomography Scan Decentration on Macular Center Subfield Thickness Measurements
Purpose.: To investigate the effect of optical coherence tomography macular grid displacement on retinal thickness measurements. Methods.: SD-OCT macular scans of 66 eyes with various retinal thicknesses were selected. Decentration of the 1-, 3-, 6-mm-diameter macular grid was simulated by manually adjusting the distance between center of the fovea (cFovea) and center of the grid (cGrid). Center subfield thickness (CSF) between the internal limiting membrane and the top of the retinal pigment epithelium was measured along the displacement distance where the grid was displaced in eight cardinal directions from the cFovea in steps of 100 μm within the central 1-mm subfield and then by 200 μm within the inner subfields. One-way/mixed-effects repeated-measures ANOVA models were used to determine changes of CSF (ΔCSF) as a function of displacement distance (for α = 0.05, power = 0.80 and effect size = 0.1). The interactions between the displacement distance and direction, center point thickness (CPT), and foveal contour were also analyzed. Results.: The CSF measurement showed statistically significant error when the displacement distance between cFovea and cGrid exceeded 200 μm. The direction of displacement did not affect the ΔCSF-distance relationship, while the CPT and foveal contour significantly affected the relationship, in that some subgroups showed slightly larger tolerance in the displacement distance up to 300 μm before reaching significant ΔCSF. Conclusions.: Small displacement distances of the macular grid from the cFovea affect CSF measurements throughout a broad range of thicknesses and retinal contour alterations from disease. Accurate registration of OCT scans or post hoc repositioning of the grid is essential to optimize CSF accuracy.
- 1 April 2012
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (4) , 2133-2141
Signal Quality Assessment of Retinal Optical Coherence Tomography Images
Purpose The purpose of this article was to assess signal quality of retinal optical coherence tomography (OCT) images from multiple devices using subjective and quantitative measurements. Methods A total of 120 multiframe OCT images from 4 spectral domain OCT devices (Cirrus, RTVue, Spectralis, and 3D OCT-1000) were evaluated subjectively by trained graders, and measured quantitatively using a derived parameter, maximum tissue contrast index (mTCI). An intensity histogram decomposition model was proposed to separate the foreground and background information of OCT images and to calculate the mTCI. The mTCI results were compared with the manufacturer signal index (MSI) provided by the respective devices, and to the subjective grading scores (SGS). Results Statistically significant correlations were observed between the paired methods (i.e., SGS and MSI, SGS and mTCI, and mTCI and MSI). Fisher's Z transformation indicated the Pearson correlation coefficient ρ ≥ 0.8 for all devices. Using the Deming regression, correlation parameters between the paired methods were established. This allowed conversion from the proprietary MSI values to SGS and mTCI that are universally applied to each device. Conclusions The study suggests signal quality of retinal OCT images can be evaluated subjectively and objectively, independent of the devices. Together with the proposed histogram decomposition model, mTCI may be used as a standardization metric for OCT signal quality that would affect measurements.
- 1 April 2012
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (4) , 2133-2141
Signal Quality Assessment of Retinal Optical Coherence Tomography Images
Purpose The purpose of this article was to assess signal quality of retinal optical coherence tomography (OCT) images from multiple devices using subjective and quantitative measurements. Methods A total of 120 multiframe OCT images from 4 spectral domain OCT devices (Cirrus, RTVue, Spectralis, and 3D OCT-1000) were evaluated subjectively by trained graders, and measured quantitatively using a derived parameter, maximum tissue contrast index (mTCI). An intensity histogram decomposition model was proposed to separate the foreground and background information of OCT images and to calculate the mTCI. The mTCI results were compared with the manufacturer signal index (MSI) provided by the respective devices, and to the subjective grading scores (SGS). Results Statistically significant correlations were observed between the paired methods (i.e., SGS and MSI, SGS and mTCI, and mTCI and MSI). Fisher's Z transformation indicated the Pearson correlation coefficient ρ ≥ 0.8 for all devices. Using the Deming regression, correlation parameters between the paired methods were established. This allowed conversion from the proprietary MSI values to SGS and mTCI that are universally applied to each device. Conclusions The study suggests signal quality of retinal OCT images can be evaluated subjectively and objectively, independent of the devices. Together with the proposed histogram decomposition model, mTCI may be used as a standardization metric for OCT signal quality that would affect measurements.