Mrinal Kr Mishra
Research Subjects
Mrinal Kr Mishra has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
A. Phukan
Department of Physics, Madhabdev University, Narayanpur, Lakhimpur, India
9 shared publicationsM. Chakraborty
Centre of Plasma Physics-Institute for Plasma Research
6 shared publicationsArindam Phukan
Department of Physics, Madhabdev University, Narayanpur, Lakhimpur, India
4 shared publicationsMonojit Chakraborty
Centre of Plasma Physics–Institute for Plasma Research, Tepesia, Sonapur, India
3 shared publications- Monojit Chakraborty
Centre of Plasma Physics - Institute for Plasma Research, Sonapur, Assam, India
3 shared publications - A. Phukan
Department of Physics, Madhabdev College, Narayanpur, Assam-784164, India
2 shared publications
Latest Publications
- 25 June 2024
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 85 (2) , 147-155
A study on sheath structure in discharge and diffusion region of a double plasma device
- 25 June 2024
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 85 (2) , 147-155
A study on sheath structure in discharge and diffusion region of a double plasma device
- 31 January 2022
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 48 (3) , 314-317
Effect of Movable Anode on Plasma Parameters in Multi-Dipole Discharge
We are reporting about the effect of a movable anode on plasma parameters in a multi-dipole magnetic cage. We have used electron-emitting filaments as the cathode and a movable metal plate as the anode. It is seen that plasma parameters change depending on the position of the plate.
- 31 January 2022
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 48 (3) , 314-317
Effect of Movable Anode on Plasma Parameters in Multi-Dipole Discharge
We are reporting about the effect of a movable anode on plasma parameters in a multi-dipole magnetic cage. We have used electron-emitting filaments as the cathode and a movable metal plate as the anode. It is seen that plasma parameters change depending on the position of the plate.
- 18 August 2021
- Published by Edtech Publishers (OPC) Private Limited in International Journal of Scientific Research in Engineering and Management
- Vol. 05 (08) , 1-6
Influence of Ion Mass on Electrical Elements of an Ion Sheath: A Comparative Study
The effect of ion mass on the values of electrical elements such as capacitance (C), resistance (R) and inductance (L) for a D.C ion sheath has been theoretically examined. Quantitative estimations of the L, C and R components as a function of plasma density and sheath potential are analyzed for atomic argon and molecular nitrogen plasma at a particular electron temperature. Values of calculated frequencies are found to be higher for gas with lower atomic mass. It is seen that values of inductance and resistance are highly dependent on ion mass, whereas values of capacitance is mass independent. Further the values of inductance and resistance are found to be higher for higher atomic mass. Keywords: Ion sheath, Ion transit time, Ion plasma frequency.
- 18 August 2021
- Published by Edtech Publishers (OPC) Private Limited in International Journal of Scientific Research in Engineering and Management
- Vol. 05 (08) , 1-6
Influence of Ion Mass on Electrical Elements of an Ion Sheath: A Comparative Study
The effect of ion mass on the values of electrical elements such as capacitance (C), resistance (R) and inductance (L) for a D.C ion sheath has been theoretically examined. Quantitative estimations of the L, C and R components as a function of plasma density and sheath potential are analyzed for atomic argon and molecular nitrogen plasma at a particular electron temperature. Values of calculated frequencies are found to be higher for gas with lower atomic mass. It is seen that values of inductance and resistance are highly dependent on ion mass, whereas values of capacitance is mass independent. Further the values of inductance and resistance are found to be higher for higher atomic mass. Keywords: Ion sheath, Ion transit time, Ion plasma frequency.
- 13 July 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 79 (6) , 1-4
Axial variation of plasma parameters in a multi-dipole discharge plasma in the presence of an ion extraction grid
- 13 July 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 79 (6) , 1-4
Axial variation of plasma parameters in a multi-dipole discharge plasma in the presence of an ion extraction grid
- 9 March 2021
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 51 (3) , 625-634
Control of Plasma Parameters by Hot Ionizing Electrons Using a Mesh Grid
- 9 March 2021
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 51 (3) , 625-634
Control of Plasma Parameters by Hot Ionizing Electrons Using a Mesh Grid
- 1 August 2018
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 44 (8) , 775-781
Plasma Parameters Controlled by a Movable Ion Sheath
It is shown that plasma parameters, such as the electron density, electron temperature, and plasma potential, in multidipole discharge plasma can be controlled by a negatively biased movable metal...
- 1 August 2018
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 44 (8) , 775-781
Plasma Parameters Controlled by a Movable Ion Sheath
It is shown that plasma parameters, such as the electron density, electron temperature, and plasma potential, in multidipole discharge plasma can be controlled by a negatively biased movable metal...
- 1 August 2015
- Published by Elsevier in Journal of Electrostatics
- Vol. 76, 201-207
Positioning of lightning rods using Monte Carlo technique
- 1 August 2015
- Published by Elsevier in Journal of Electrostatics
- Vol. 76, 201-207
Positioning of lightning rods using Monte Carlo technique
- 1 August 2014
- Published by Pleiades Publishing Ltd in Journal of Experimental and Theoretical Physics
- Vol. 119 (2) , 326-330
Effect of cold electron emission on diffusion plasma parameters and the sheath structure in a double plasma device
It is observed experimentally that by injecting cold electrons in the discharge region of a double plasma device, the plasma parameters and sheath structure can be controlled in the other region, which is devoid of any electrical discharge. The main discharge region is separated from the region under investigation by a grounded mesh grid. Both cold and hot ionizing electrons are emitted from separate sets of filaments in the discharge region. With an increase in the cold electron emission current, the plasma parameters in the discharge region get changed, which in turn alter the plasma parameters in the other region. Two important effects caused by cold electrons in the diffusion region are the increase in the plasma density and decrease in the plasma potential. The increase in the plasma density and decrease in the sheath potential drop therefore cause the contraction of the sheath.
- 1 August 2014
- Published by Pleiades Publishing Ltd in Journal of Experimental and Theoretical Physics
- Vol. 119 (2) , 326-330
Effect of cold electron emission on diffusion plasma parameters and the sheath structure in a double plasma device
It is observed experimentally that by injecting cold electrons in the discharge region of a double plasma device, the plasma parameters and sheath structure can be controlled in the other region, which is devoid of any electrical discharge. The main discharge region is separated from the region under investigation by a grounded mesh grid. Both cold and hot ionizing electrons are emitted from separate sets of filaments in the discharge region. With an increase in the cold electron emission current, the plasma parameters in the discharge region get changed, which in turn alter the plasma parameters in the other region. Two important effects caused by cold electrons in the diffusion region are the increase in the plasma density and decrease in the plasma potential. The increase in the plasma density and decrease in the sheath potential drop therefore cause the contraction of the sheath.
- Open Access
- 1 March 2014
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2014 (3) , 33J01
Influence of plasma density on associated electrical elements of an ion sheath
An attempt is made to theoretically estimate the values of electrical elements such as capacitance, resistance, and inductance for an ion sheath using experimental parameters. Quantitative estimations of the L, C and R components as a function of plasma density are analyzed for argon plasma at a particular electron temperature. The magnitude of the estimated grid bias approaches the real value for higher values of a correction factor.
- 1 March 2014
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2014 (3) , 33J01
Open AccessInfluence of plasma density on associated electrical elements of an ion sheath
An attempt is made to theoretically estimate the values of electrical elements such as capacitance, resistance, and inductance for an ion sheath using experimental parameters. Quantitative estimations of the L, C and R components as a function of plasma density are analyzed for argon plasma at a particular electron temperature. The magnitude of the estimated grid bias approaches the real value for higher values of a correction factor.
- 3 July 2013
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 79 (5) , 913-920
Effect of discharge voltage on bi-Maxwellian electrons in the diffusion plasma region of a double plasma device
The effect of discharge voltage on bi-Maxwellian electrons in the diffusion region of a double plasma device has been studied. The increase in discharge voltage enhances the flux of ionizing electrons to the diffusion region separated by a mesh grid. This energetic electron flux in turn affects other important parameters such as density, electron temperature, plasma potential and floating potential in the diffusion region. Furthermore, the dependence of density and temperature of both ionizing and plasma electrons on discharge voltage is investigated. The electron energy probability function obtained from probe data also indicates the bi-Maxwellian nature of electrons.
- 3 July 2013
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 79 (5) , 913-920
Effect of discharge voltage on bi-Maxwellian electrons in the diffusion plasma region of a double plasma device
The effect of discharge voltage on bi-Maxwellian electrons in the diffusion region of a double plasma device has been studied. The increase in discharge voltage enhances the flux of ionizing electrons to the diffusion region separated by a mesh grid. This energetic electron flux in turn affects other important parameters such as density, electron temperature, plasma potential and floating potential in the diffusion region. Furthermore, the dependence of density and temperature of both ionizing and plasma electrons on discharge voltage is investigated. The electron energy probability function obtained from probe data also indicates the bi-Maxwellian nature of electrons.