Wei-Mon Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wei-Mon Yan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Han-Chieh Chiu
Technology and Science Institute of Northern Taiwan, Taipei, Taiwan
2 shared publications - Jer-Huan Jang
Department of Mechanical Engineering, Ming Chi University of Technology, New Taipei City 243, Taiwan
2 shared publications Xiao-Dong Wang
Department of Thermal Engineering, School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
2 shared publicationsC.P. Wang
Department of Mechanical Engineering, National Chiao Tung University, Hsinchu, Taiwan 300, ROC
1 shared publicationChinh-Chang Shih
Department of Mechanical Engineering, Northern Taiwan Institute of, Science and Technology, Pei-To, Taipei, Taiwan 112, ROC
1 shared publication- David. T. W. Lin
Institute of Mechatronic System Engineering, National University of Tainan, Tainan, Taiwan
1 shared publication
Latest Publications
- 20 July 2010
- Published by ASME International in Journal of Fuel Cell Science and Technology
- Vol. 7 (5) , 0510191-0510199
Channel Geometry Effect for Proton Exchange Membrane Fuel Cell With Serpentine Flow Field Using a Three-Dimensional Two-Phase Model
This study presents a complete three-dimensional, two-phase transport model for proton exchange membrane fuel cells based on the two-fluid method, which couples the mass, momentum, species, and electrical potential equations. The different liquid water transport mechanisms in the flow channels, gas diffusion layers, catalyst layers, and membrane are modeled using two different liquid water transport equations. In the flow channels, gas diffusion layers, and catalyst layers, the generalized Richards equation is used to describe the liquid water transport including the effect of the pressure gradient, capillary diffusion, evaporation and condensation, and electro-osmotic, while in the membrane, the liquid water transport equation only takes into account the effect of back diffusion and electro-osmotic. Springer’s model is utilized on the catalyst layer-membrane interface to maintain continuum of the liquid water distribution. The model is used to investigate the effect of flow channel aspect ratio on the performance of fuel cells with single and triple serpentine flow fields. The predictions show that for both flow fields, the cell performance improves with decreasing aspect ratio. The aspect ratio has less effect on the cell performance for the triple serpentine flow field than for the single serpentine flow field due to the weaker under-rib convection.
- 20 July 2010
- Published by ASME International in Journal of Fuel Cell Science and Technology
- Vol. 7 (5) , 0510191-0510199
Channel Geometry Effect for Proton Exchange Membrane Fuel Cell With Serpentine Flow Field Using a Three-Dimensional Two-Phase Model
This study presents a complete three-dimensional, two-phase transport model for proton exchange membrane fuel cells based on the two-fluid method, which couples the mass, momentum, species, and electrical potential equations. The different liquid water transport mechanisms in the flow channels, gas diffusion layers, catalyst layers, and membrane are modeled using two different liquid water transport equations. In the flow channels, gas diffusion layers, and catalyst layers, the generalized Richards equation is used to describe the liquid water transport including the effect of the pressure gradient, capillary diffusion, evaporation and condensation, and electro-osmotic, while in the membrane, the liquid water transport equation only takes into account the effect of back diffusion and electro-osmotic. Springer’s model is utilized on the catalyst layer-membrane interface to maintain continuum of the liquid water distribution. The model is used to investigate the effect of flow channel aspect ratio on the performance of fuel cells with single and triple serpentine flow fields. The predictions show that for both flow fields, the cell performance improves with decreasing aspect ratio. The aspect ratio has less effect on the cell performance for the triple serpentine flow field than for the single serpentine flow field due to the weaker under-rib convection.
- 1 January 2010
- Published by ASME International
- p. 443-451
Experimental Study on the Heat Transfer Under Impinging Jet Array Using Liquid Crystal Thermograph
In this work, the effects of jet geometry and the arrangement of film holes on the target plate on the impinging heat transfer are experimentally investigated in detail. A liquid crystal thermograph technology is employed in this study. The aspect ratios (AR) of elliptical jet with five different values, 4, 2, 1, 0.5, and 0.25, jet Reynolds number ranging from 2000 to 4000, and jet-to-target spacing ranging from 1.5 to 4.5 are considered to investigate impingement heat transfer performance. In addition, three arrangements of film hole on the target plates, named side-, middle- and staggered-types, are tested, respectively. The experimental results show that the Nu increases with the increase of jet Reynolds number. Better heat transfer is noted for the cases with smaller jet-to-plate spacing. For the effect of the arrangement of pores on the target surface, the heat transfer on middle-type plate is more significant than the other two for smaller jet-to-plate spacing. As for the effect of aspect ratio, results indicate that the optimal heat transfer performance is found with circular jet of AR = 1.
- 1 January 2010
- Published by ASME International
- p. 443-451
Experimental Study on the Heat Transfer Under Impinging Jet Array Using Liquid Crystal Thermograph
In this work, the effects of jet geometry and the arrangement of film holes on the target plate on the impinging heat transfer are experimentally investigated in detail. A liquid crystal thermograph technology is employed in this study. The aspect ratios (AR) of elliptical jet with five different values, 4, 2, 1, 0.5, and 0.25, jet Reynolds number ranging from 2000 to 4000, and jet-to-target spacing ranging from 1.5 to 4.5 are considered to investigate impingement heat transfer performance. In addition, three arrangements of film hole on the target plates, named side-, middle- and staggered-types, are tested, respectively. The experimental results show that the Nu increases with the increase of jet Reynolds number. Better heat transfer is noted for the cases with smaller jet-to-plate spacing. For the effect of the arrangement of pores on the target surface, the heat transfer on middle-type plate is more significant than the other two for smaller jet-to-plate spacing. As for the effect of aspect ratio, results indicate that the optimal heat transfer performance is found with circular jet of AR = 1.
- 31 October 2007
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 50 (21-22) , 4229-4242
Combined mixed convection and radiation heat transfer in rectangular ducts rotating about a parallel axis
- 31 October 2007
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 50 (21-22) , 4229-4242
Combined mixed convection and radiation heat transfer in rectangular ducts rotating about a parallel axis
- 1 January 2007
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 154 (12) , B1338-B1348
Effects of Flow Channel Area Ratio on Local Transport Characteristics and Cell Performance of 3D PEMFCs
The objective of this work is to examine the effects of the flow channel area ratio (40%, 50%, and 60%) on the reactant gas transport and the cell performance of proton exchange membrane fuel cells (PEMFCs) with parallel and interdigitated flow channel designs. The effects of liquid water formation on the reactant gas transport are taken into account in the present study. Higher flow area ratios are expected to provide more area for fuel diffusion into the gas diffusion layer to enhance the electrochemical reaction rate and improve cell performance. Numerical predictions show that the cell performance for parallel flow channel design can be enhanced by increasing the flow channel area ratio and the best overall cell performance occurs for a flow channel area ratio of 60%. For the interdigitated flow channel design, because the fuel transport is by forced convection rather than diffusion, the flow channel area ratio has less effect on cell performance. Taking into account liquid water removal and pressure losses, the optimal cell performance occurs for a flow channel area ratio of 50% for the interdigitated flow channel design. The results also show that the flow channel area ratio and liquid water distribution significantly influence cell performance at lower voltages.
- 1 January 2007
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 154 (12) , B1338-B1348
Effects of Flow Channel Area Ratio on Local Transport Characteristics and Cell Performance of 3D PEMFCs
The objective of this work is to examine the effects of the flow channel area ratio (40%, 50%, and 60%) on the reactant gas transport and the cell performance of proton exchange membrane fuel cells (PEMFCs) with parallel and interdigitated flow channel designs. The effects of liquid water formation on the reactant gas transport are taken into account in the present study. Higher flow area ratios are expected to provide more area for fuel diffusion into the gas diffusion layer to enhance the electrochemical reaction rate and improve cell performance. Numerical predictions show that the cell performance for parallel flow channel design can be enhanced by increasing the flow channel area ratio and the best overall cell performance occurs for a flow channel area ratio of 60%. For the interdigitated flow channel design, because the fuel transport is by forced convection rather than diffusion, the flow channel area ratio has less effect on cell performance. Taking into account liquid water removal and pressure losses, the optimal cell performance occurs for a flow channel area ratio of 50% for the interdigitated flow channel design. The results also show that the flow channel area ratio and liquid water distribution significantly influence cell performance at lower voltages.
- 22 September 2006
- Published by Elsevier in Journal of Power Sources
- Vol. 159 (2) , 1071-1077
Transient behavior of CO poisoning of the anode catalyst layer of a PEM fuel cell
- 22 September 2006
- Published by Elsevier in Journal of Power Sources
- Vol. 159 (2) , 1071-1077
Transient behavior of CO poisoning of the anode catalyst layer of a PEM fuel cell
- 1 June 2006
- Published by Elsevier in Journal of Power Sources
- Vol. 156 (2) , 244-252
Numerical study of reactant gas transport phenomena and cell performance of proton exchange membrane fuel cells
- 1 June 2006
- Published by Elsevier in Journal of Power Sources
- Vol. 156 (2) , 244-252
Numerical study of reactant gas transport phenomena and cell performance of proton exchange membrane fuel cells
- 15 December 2005
- Published by Elsevier in Journal of Power Sources
- Vol. 159 (1) , 514-523
Dynamic analysis of gas transport in cathode side of PEM fuel cell with interdigitated flow field
- 15 December 2005
- Published by Elsevier in Journal of Power Sources
- Vol. 159 (1) , 514-523
Dynamic analysis of gas transport in cathode side of PEM fuel cell with interdigitated flow field
- 1 July 1999
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 13 (3) , 394-396
Estimation of Wall Heat Flux in an Inverse Convection Problem
- 1 July 1999
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 13 (3) , 394-396
Estimation of Wall Heat Flux in an Inverse Convection Problem
- 1 January 1999
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 42 (1) , 35-47
Mixed convection heat transfer in a radially rotatingsquare duct with radiation effects
- 1 January 1999
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 42 (1) , 35-47
Mixed convection heat transfer in a radially rotatingsquare duct with radiation effects
- 1 December 1998
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 41 (23) , 3719-3729
Evaporative cooling of liquid film in turbulent mixed convection channel flows
- 1 December 1998
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 41 (23) , 3719-3729
Evaporative cooling of liquid film in turbulent mixed convection channel flows