Abraham Mathew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abraham Mathew has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Eric Mark Pauli
Penn State Hershey Medical Center
3 shared publications - Christopher S. Hollenbeak
Department of Health Policy and Administration, College of Health and Human Development, The Pennsylvania State University, University Park, PA
1 shared publication Erin K. Greenleaf
1 shared publicationJames A. Cronin
Pennsylvania State University, State College, PA
1 shared publication- Jegan Gopal
Department of Surgery, Division of Minimally Invasive and Bariatric Surgery, Penn State Milton S. Hershey Medical Center, Hershey, PA, USA
1 shared publication Jennifer L. Maranki
1 shared publication
Latest Publications
- 1 May 2017
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 85 (5) , AB212
Sa1234 Clinical Symptomatology Based on the Scoring System After Per Oral Endoscopic Myotomy
- 1 May 2017
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 85 (5) , AB212
Sa1234 Clinical Symptomatology Based on the Scoring System After Per Oral Endoscopic Myotomy
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 223 (4) , S13-S14
Cost-Effectiveness of Per Oral Endoscopic Myotomy Relative to Laparoscopic Heller Myotomy for Treatment of Achalasia
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 223 (4) , S13-S14
Cost-Effectiveness of Per Oral Endoscopic Myotomy Relative to Laparoscopic Heller Myotomy for Treatment of Achalasia
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69 (5) , AB168
Prevention of Small Bowel Distention During Transgastric Natural Orifice Translumenal Endoscopic Surgery (NOTES)® Using a Novel Intestinal Occlusion Device
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69 (5) , AB168
Prevention of Small Bowel Distention During Transgastric Natural Orifice Translumenal Endoscopic Surgery (NOTES)® Using a Novel Intestinal Occlusion Device
- 1 January 2007
- Published by ASME International
- p. 625-635
Design of a Compliant Endoscopic Suturing Instrument
This paper outlines the development and initial optimization of a compliant endoscopic suturing instrument. The developing field of Natural Orifice Transluminal Endoscopic Surgery requires innovative instruments to meet the size limitations inherent in this type of minimally invasive surgery; using compliant mechanisms is proposed as one method of meeting this requirement. Three initial compliant designs were created, modeled, and compared for a distal opening of 10 mm. Restricting these designs so that they must fit within a 3.3 mm working channel is currently unique in endoscopic suturing instruments. A design that utilizes contact for stress relief and intertwining parts for added deflection was selected from the three. ANSYS® was used to aid in graphical optimization to maximize the jaw opening and maximize the puncture force of the selected design. The best geometry has a distal opening of 13.8 mm at the tips and can supply a puncturing force of 6.33 N. A prototype has been machined using the optimized dimensions and is ready to be tested. This initial study in compliant suturing instrument designs has revealed response patterns for the chosen geometries that will lead to further refinements and improvements in future models.
- 1 January 2007
- Published by ASME International
- p. 625-635
Design of a Compliant Endoscopic Suturing Instrument
This paper outlines the development and initial optimization of a compliant endoscopic suturing instrument. The developing field of Natural Orifice Transluminal Endoscopic Surgery requires innovative instruments to meet the size limitations inherent in this type of minimally invasive surgery; using compliant mechanisms is proposed as one method of meeting this requirement. Three initial compliant designs were created, modeled, and compared for a distal opening of 10 mm. Restricting these designs so that they must fit within a 3.3 mm working channel is currently unique in endoscopic suturing instruments. A design that utilizes contact for stress relief and intertwining parts for added deflection was selected from the three. ANSYS® was used to aid in graphical optimization to maximize the jaw opening and maximize the puncture force of the selected design. The best geometry has a distal opening of 13.8 mm at the tips and can supply a puncturing force of 6.33 N. A prototype has been machined using the optimized dimensions and is ready to be tested. This initial study in compliant suturing instrument designs has revealed response patterns for the chosen geometries that will lead to further refinements and improvements in future models.