TQTerence I. Quickenden

Terence I. Quickenden

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Terence I. Quickenden has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • C. G. Freeman

    University of Canterbury

    4 shared publications
  • D. F. Sangster

    CSIRO Division of Chemical Physics, Lucas Heights Research Laboratories, Private Mail Bag 7, Sutherland, N.S.W. 2232, Australia

    3 shared publications
  • J. I. Creamer

    Department of Chemistry, M313 School of Biomedical and Chemical Sciences, University of Western Australia, 35 Stirling Highway, Crawley, WA 6009, Australia

    3 shared publications
  • Patrick Andrew Robertson

    Department of Chemistry, University of Oxford, Chemistry Research Laboratory, 12 Mansfield Rd, Oxford OX1 3TA, United Kingdom

    2 shared publications
  • R. A. J. Litjens

    Department of Physical and Inorganic Chemistry, University of Western Australia, Nedlands, W. A. 6009, Australia

    2 shared publications
  • B. J. Selby

    The University of Western Australia

    1 shared publication

Latest Publications

  • Isotopic effects on the time-dependences of 420 nm ice luminescence excited by UV light

    by B. J. Selby, T. I. Quickenden, C. G. Freeman

    The kinetics of the 420 nm luminescence emitted from H2O and D2O polycrystalline Ih ices have been studied over the 77 to 162 K temperature range. In the case of both H2O and D2O ices, it was found that the luminescence rise and decay curves consisted of two luminescence components, and superimposing two first-order curves with different rate constants gave the best fit to the decay and rise curves. The mean lifetimes of the two luminescence components were 1.08 ± 0.03 s and 2.47 ± 0.03 s. The rate constants were found to have negligible temperature dependences, which led to activation energies well below those obtained for either activation-limited processes or even diffusion-limited processes. Furthermore, it was found that the luminescence kinetics were not affected by isotopic substitution of D for H in the ice lattice. These observations suggest that the rate-determining step in the mechanism for the production of the luminescence is a slow (probably spinforbidden) electronic transition that can occur at two different rates due to the presence of two different types of trapping sites in the ice lattice. A possible candidate for the electronic transition is the 4Σ → X 2Π transition of excited OH. radicals and not the previously suggested and ubiquitous A 2Σ+ → X 2Π transition of this species.


  • Attempted cleaning of bloodstains and its effect on the forensic luminol test

    by Jonathan I. Creamer, Terence I. Quickenden, Leah B. Crichton, Patrick Robertson, Rasha A. Ruhayel

    The forensic luminol test has long been valued for its ability to detect trace amounts of blood that are invisible to the naked eye. This is the first quantitative study to determine the effect on the luminol test when an attempt is made to clean bloodstained tiles with a known interfering catalyst (bleach). Tiles covered with either wet or dry blood were tested, and either water or sodium hypochlorite solution (bleach) was used to clean the tiles. As expected, the chemiluminescence intensity produced when luminol was applied generally decreased with the number of times that a tile was cleaned with water, until the chemiluminescence was neither visible nor detectable. However, when the tiles were cleaned with bleach there was an initial drop in chemiluminescence intensity, followed by a rise to a consistently high value, visibly indistinguishable from that of blood. Examination of bleach drying time suggested that any interfering effect becomes negligible after 8 h. Copyright © 2005 John Wiley & Sons, Ltd.


  • The forensic use of luminol chemiluminescence to detect traces of blood inside motor vehicles

    by T. I. Quickenden, C. P. Ennis, J. I. Creamer

    The luminol test for blood was carried out on a set of interior fittings and surfaces inside three different makes of modern motor car. The surfaces and fittings provided little interference with the test for blood, although there was some detectable chemiluminescence when the test was applied to blood‐free material from a seatbelt, a boot‐lining and a gear‐knob. The case with which haemoglobin samples could be washed off interior car surfaces was also examined for seat fabrics, carpets, roof‐linings and various other plastic interior surfaces. A standard wash with water alone was not very effective and removed only ca. 50% of the haemoglobin. A standard wash with soapy water or with a proprietary multipurpose car cleaner removed ca. 90% of the haemoglobin from the tested surface. The effect of high car interior temperatures on haemoglobin samples that were subsequently used in the luminol test was also examined. It was shown that the sensitivity of the luminol test was not decreased but was increased by the prior heating of a haemoglobin sample. This effect was attributed to the thermal conversion of haemoglobin to the more brighter catalyst for chemiluminescence, methaemoglobin. The enthalpy of this conversion in the solid state was found to be 14.1 kJ/mol. Copyright © 2004 John Wiley & Sons, Ltd.


  • A comprehensive experimental study of industrial, domestic and environmental interferences with the forensic luminol test for blood

    by J. I. Creamer, T. I. Quickenden, M. V. Apanah, K. A. Kerr, P. Robertson

    This paper presents the first comprehensive and quantitative study of substances that interfere with the forensic luminol test for blood. Two hundred and fifty substances have been selected on the basis of modern lifestyles and of contiguity with crime scenes. The intensity of the chemiluminescence produced by each substance has been measured relative to that of haemoglobin and the peak wavelength shift has also been determined. The following is a short list of nine substances that produce chemiluminescence intensities comparable with that of haemoglobin: turnips, parsnips, horseradishes, commercial bleach (NaClO), copper metal, some furniture polishes, some enamel paints, and some interior fabrics in motor vehicles. Care needs to be taken when the luminol test for blood is used in the presence of these substances. Copyright © 2003 John Wiley & Sons, Ltd.


  • A study of common interferences with the forensic luminol test for blood

    by T. I. Quickenden, J. I. Creamer


  • Increasing the specificity of the forensic luminol test for blood

    by Terence I. Quickenden, Paul D. Cooper

    It is shown that the presumptive luminol chemiluminescence test for the presence of traces of blood can be made more determinative by measuring the peak emission wavelength of the luminol chemiluminescence. When sprayed onto a surface containing traces of human haemoglobin, a 1 g/L solution of aqueous luminol containing 7 g/L sodium perborate gives an emission peak at 455 ± 2 nm, whereas the same mixture gives an emission peak at 430 ± 3 nm when sprayed onto a surface containing traces of sodium hypochlorite (household bleach). This spectral difference can readily be determined using spectroscopic equipment that either scans the spectrum before significant luminescence decay occurs or corrects the spectrum for the effects of any decay. It was found that bovine haemoglobin and human haemoglobin showed no significant spectral differences. Copyright © 2001 John Wiley & Sons, Ltd.


  • Time resolved study of the luminescence produced by the pulse radiolysis of D2O vapor

    by T. I. Quickenden, C. F. Vernon, R. A. J. Litjens, C. G. Freeman, D. F. Sangster

    D2O vapor was irradiated using a 0.53 MeV pulsed electron beam and the 200–900 nm wavelength range was examined for luminescence emission from excited fragments. Spectral lines of the OD (C 2∑+→A 2∑+) and the OD (A 2∑+→X 2Π) transitions were observed, as were the Balmer transitions of deuterium between n=6→n=2 and n=3→n=2, and the oxygen transitions O+(3p 4D0→3s 4P),O(3p 5P→3s 5S0), and O(3p 3P→3s 3S0). Values were obtained for the natural lifetimes, quenching rate constants, and quenching cross sections at 298 K for the majority of the above excited species. The natural lifetimes and quenching data obtained for the transitions of excited OD and oxygen species were, as expected, similar to the values obtained for the corresponding species in H2O vapor. However, Balmer D transitions exhibited shorter natural lifetimes and smaller quenching cross sections than the corresponding Balmer H transitions. The differences in quenching rate were much larger than the effect of isotopic substitution on collision frequency. Both lifetime and quenching differences were attributed to greater population of the p sublevels in excited D as compared with H.


  • Visible and ultraviolet emission from pulse irradiated amorphous and polycrystalline H2O ice

    by C. G. Freeman, T. I. Quickenden, R. A. J. Litjens, D. F. Sangster

    Luminescence peaking at 405 nm was observed when thin films of amorphous or polycrystalline ice at 97 K were irradiated with a pulsed beam of 0.53 MeV electrons. These emissions differed from the luminescence emitted by crystalline ice in that memory effects were not observed; the peak wavelengths were red shifted by ∼20 nm; and the half‐lives were 6–9 ns instead of ∼400 ns. The emission spectra of polycrystalline ice samples produced by rapid deposition or by annealing amorphous ice were similar, but both had substantially lower intensities than amorphous ice spectra.


  • Time resolved 360 to 600 nm luminescence produced by the pulse radiolysis of water vapor

    by C. G. Freeman, T. I. Quickenden, D. F. Sangster

    Water vapor was excited by a 0.53 MeV pulsed electron beam and examined for luminescence emission in the 360–600 nm region. Spectral lines arising from the Balmer transitions H(n=4→n=2), H(n=5→n=2), and H(n=6→n=2) of the hydrogen atom and the transitions 3p4D05/2→3s4P3/2, 3p4D07/2→ 3s4P5/2, and 3p4D01/2→3s4P1/2 of the O+ ion were observed. The Balmer lines were found to be quenched by water vapor with rate constants at 293 K of (9.77±0.26)×10−9, (10.67±0.45)×10−9, and (12.3±2.3)×10−9 cm3 molecule−1 s−1, respectively. The excited O+ ions were also quenched strongly by water vapor but line intensities were insufficient for rate measurements to be carried out.