Alan Argento
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alan Argento has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Wonsuk Kim
Department of Mechanical Engineering, University of Michigan-Dearborn, Dearborn, MI 48128, USA
6 shared publications Wonsuk Kim
Department of Mechanical Engineering, University of Michigan-Dearborn, Dearborn, MI, USA
4 shared publications- Frank W. Rozsa
Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI 48105
2 shared publications - Guan Xu
University of Michigan
2 shared publications Linyu Ni
Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA
2 shared publicationsSayoko E. Moroi
Department of Ophthalmology and Visual Sciences, Havener Eye Institute, the Ohio State University Wexner Medical Center, Columbus, OH, USA
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14  (10) , 9
Biomechanical Relationships Between the Aqueous Veins and Perilimbal Sclera During Intraocular Pressure Regulation
A major assumption of microinvasive glaucoma surgeries (MIGS) is that effective intraocular pressure (IOP) reduction can be achieved by enhancing aqueous humor (AH) outflow into the aqueous veins. However, this IOP outcome is not predictable in part due to lack of knowledge concerning the role of tissue biomechanics on AH outflow through the distal aqueous veins within the perilimbal sclera (PLS). The purpose of this study is to investigate the biomechanical response of the aqueous veins and the PLS and their interaction during IOP. Optical resolution photoacoustic microscopy were implemented to capture the 3D deformations of the aqueous veins and in the surrounding PLS during aqueous outflow in porcine and human whole globes. Partial trabeculotomy was performed to minimize the contribution of the trabecular meshwork to the outflow resistance. The deformations of the tissue components and the IOP were measured in both porcine and human eyes. Strong correlations were found among the relative cross-sectional area of the aqueous veins, strains in the PLS in porcine eyes, and the steady-state (SS) IOP of porcine eyes. The data shows that stiff PLS restricts vein cross-sectional area and results in overall higher SS IOP in an eye. The findings in this study suggest the potential for predicting the limit of effectiveness of an MIGS given knowledge of the interactive behaviors of the aqueous veins and PLS in an eye.
- 1 October 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14  (10) , 9
Open AccessBiomechanical Relationships Between the Aqueous Veins and Perilimbal Sclera During Intraocular Pressure Regulation
A major assumption of microinvasive glaucoma surgeries (MIGS) is that effective intraocular pressure (IOP) reduction can be achieved by enhancing aqueous humor (AH) outflow into the aqueous veins. However, this IOP outcome is not predictable in part due to lack of knowledge concerning the role of tissue biomechanics on AH outflow through the distal aqueous veins within the perilimbal sclera (PLS). The purpose of this study is to investigate the biomechanical response of the aqueous veins and the PLS and their interaction during IOP. Optical resolution photoacoustic microscopy were implemented to capture the 3D deformations of the aqueous veins and in the surrounding PLS during aqueous outflow in porcine and human whole globes. Partial trabeculotomy was performed to minimize the contribution of the trabecular meshwork to the outflow resistance. The deformations of the tissue components and the IOP were measured in both porcine and human eyes. Strong correlations were found among the relative cross-sectional area of the aqueous veins, strains in the PLS in porcine eyes, and the steady-state (SS) IOP of porcine eyes. The data shows that stiff PLS restricts vein cross-sectional area and results in overall higher SS IOP in an eye. The findings in this study suggest the potential for predicting the limit of effectiveness of an MIGS given knowledge of the interactive behaviors of the aqueous veins and PLS in an eye.
- Open Access
- 19 December 2024
- Published by MDPI AG in Bioengineering
- Vol. 11  (12) , 1289
Relaxation Behavior of Cerclage Cables and Its Effect on Bone Clamping Force
Cerclage is an orthopedic surgical fixation technique using a cable wrapped, tensioned, and secured around a bone’s circumference. It is important to minimize the loss in cable tension that often occurs due to stress relaxation. The purpose of this work was to study the effect of tensioning protocols on the long-term loss of tension due to stress relaxation. The native mechanical properties and relaxation behavior of the cables were determined using traditional mechanical testing machines and methods. Four step-wise cable tensioning protocols were then trialed to compare the cable tension losses. A testing apparatus was developed to simultaneously measure cable tension and the resulting clamping force on a real bone. A five-parameter linear viscoelastic model was used to fit relaxation data to estimate the long-term relaxation of the cables beyond the time of the experiment. The four cables were found to have similar mechanical and viscoelastic behaviors. A two-step cable-tightening protocol was found to significantly reduce cable tension loss when compared to a one-step protocol for all cables. The benefit of the two-step protocol was reinforced by the relaxation results of the cable wrapped and tightened around a pig femoral bone. These results indicate that one retightening step should be conducted during the surgical placement of a cerclage cable to reduce the loss of cable tension resulting from relaxation.
- 19 December 2024
- Published by MDPI AG in Bioengineering
- Vol. 11  (12) , 1289
Open AccessRelaxation Behavior of Cerclage Cables and Its Effect on Bone Clamping Force
Cerclage is an orthopedic surgical fixation technique using a cable wrapped, tensioned, and secured around a bone’s circumference. It is important to minimize the loss in cable tension that often occurs due to stress relaxation. The purpose of this work was to study the effect of tensioning protocols on the long-term loss of tension due to stress relaxation. The native mechanical properties and relaxation behavior of the cables were determined using traditional mechanical testing machines and methods. Four step-wise cable tensioning protocols were then trialed to compare the cable tension losses. A testing apparatus was developed to simultaneously measure cable tension and the resulting clamping force on a real bone. A five-parameter linear viscoelastic model was used to fit relaxation data to estimate the long-term relaxation of the cables beyond the time of the experiment. The four cables were found to have similar mechanical and viscoelastic behaviors. A two-step cable-tightening protocol was found to significantly reduce cable tension loss when compared to a one-step protocol for all cables. The benefit of the two-step protocol was reinforced by the relaxation results of the cable wrapped and tightened around a pig femoral bone. These results indicate that one retightening step should be conducted during the surgical placement of a cerclage cable to reduce the loss of cable tension resulting from relaxation.
- Open Access
- 2 October 2024
- Published by MDPI AG in Bioengineering
- Vol. 11  (10) , 996
Effects of Genipin Crosslinking of Porcine Perilimbal Sclera on Mechanical Properties and Intraocular Pressure
The mechanical properties of sclera play an important role in ocular functions, protection, and disease. Modulating the sclera’s properties by exogenous crosslinking offers a way to expand the tissue’s range of properties for study of the possible influences on the eye’s behavior and diseases such as glaucoma and myopia. The focus of this work was to evaluate the effects of genipin crosslinking targeting the porcine perilimbal sclera (PLS) since the stiffness of this tissue was previously found in a number of studies to influence the eye’s intraocular pressure (IOP). The work includes experiments on tensile test specimens and whole globes. The specimen tests showed decreased strain-rate dependence and increased relaxation stress due to the cross-linker. Whole globe perfusion experiments demonstrated that eyes treated with genipin in the perilimbal region had increased IOPs compared to the control globes. Migration of the cross-linker from the target tissue to other tissues is a confounding factor in whole globe, biomechanical measurements, with crosslinking. A novel quantitative genipin assay of the trabecular meshwork (TM) was developed to exclude globes where the TM was inadvertently crosslinked. The perfusion study, therefore, suggests that elevated stiffness of the PLS can significantly increase IOP apart from effects of the TM in the porcine eye. These results demonstrate the importance of PLS biomechanics in aqueous outflow regulation and support additional investigations into the distal outflow pathways as a key source of outflow resistance.
- 2 October 2024
- Published by MDPI AG in Bioengineering
- Vol. 11  (10) , 996
Open AccessEffects of Genipin Crosslinking of Porcine Perilimbal Sclera on Mechanical Properties and Intraocular Pressure
The mechanical properties of sclera play an important role in ocular functions, protection, and disease. Modulating the sclera’s properties by exogenous crosslinking offers a way to expand the tissue’s range of properties for study of the possible influences on the eye’s behavior and diseases such as glaucoma and myopia. The focus of this work was to evaluate the effects of genipin crosslinking targeting the porcine perilimbal sclera (PLS) since the stiffness of this tissue was previously found in a number of studies to influence the eye’s intraocular pressure (IOP). The work includes experiments on tensile test specimens and whole globes. The specimen tests showed decreased strain-rate dependence and increased relaxation stress due to the cross-linker. Whole globe perfusion experiments demonstrated that eyes treated with genipin in the perilimbal region had increased IOPs compared to the control globes. Migration of the cross-linker from the target tissue to other tissues is a confounding factor in whole globe, biomechanical measurements, with crosslinking. A novel quantitative genipin assay of the trabecular meshwork (TM) was developed to exclude globes where the TM was inadvertently crosslinked. The perfusion study, therefore, suggests that elevated stiffness of the PLS can significantly increase IOP apart from effects of the TM in the porcine eye. These results demonstrate the importance of PLS biomechanics in aqueous outflow regulation and support additional investigations into the distal outflow pathways as a key source of outflow resistance.
- Open Access
- 21 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12  (1) , 1-11
Effects of interfacial dynamics on the damping of biocomposites
A damping model is developed based on the mechanism of interfacial interaction in nanoscale particle reinforced composites. The model includes the elasticity of the materials and the effects of interfacial adhesion hysteresis. Specific results are given for the case of bio-based PA610 polyamide reinforced by nanocrystalline cellulose (CNC), based on a previous study that showed this composite possesses very high damping. The presence of hydrogen bonding at the interface between the particle and matrix and the large interfacial area due to the filler’s nano size are shown to be the main causes of the high damping enhancement. The influence of other parameters, such as interfacial distance and stiffness of the matrix materials are also discussed. The modeling work can be used as a guide in designing composites with good damping properties.
- 21 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12  (1) , 1-11
Open AccessEffects of interfacial dynamics on the damping of biocomposites
A damping model is developed based on the mechanism of interfacial interaction in nanoscale particle reinforced composites. The model includes the elasticity of the materials and the effects of interfacial adhesion hysteresis. Specific results are given for the case of bio-based PA610 polyamide reinforced by nanocrystalline cellulose (CNC), based on a previous study that showed this composite possesses very high damping. The presence of hydrogen bonding at the interface between the particle and matrix and the large interfacial area due to the filler’s nano size are shown to be the main causes of the high damping enhancement. The influence of other parameters, such as interfacial distance and stiffness of the matrix materials are also discussed. The modeling work can be used as a guide in designing composites with good damping properties.
- 5 October 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50  (11) , 1648-1660
Impact Mitigation Properties and Material Characterization of Women’s Lacrosse Headgear
The purpose of this study was to examine the impact attenuation properties of women’s lacrosse headgear and to characterize mechanical properties of the materials of which they are composed. Impacts using a linear impactor (2.2, 2.9, and 5.0 m/s) and a projectile shooter (13.4 and 27.0 m/s) were applied to a Hybrid III 50th male head-neck assembly at six impact locations to replicate realistic women’s lacrosse head impacts. Individual materials that make up the headgear were tested in compression at two quasi-static strain rates, 0.01/s and1/s, and 100/s using uniaxial test machines. For the linear impactor tests, results showed a significant decrease in peak linear and rotational acceleration (PLA and PRA), peak rotational velocity (PRV), head injury criteria and brain injury criteria in the helmeted impacts (p < 0.022). During the ball impacts PRV and PRA were significantly lower for both helmeted conditions compared with no helmet (p < 0.01). Material characterization tests indicated a range of rate effects in these materials ranging from weak to pronounced, and these effects correspondingly influenced the strain energy density graphs. The connection of the materials’ rate effects to the performance of the headgear is described in general and in relation to the impact tests.
- 5 October 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50  (11) , 1648-1660
Impact Mitigation Properties and Material Characterization of Women’s Lacrosse Headgear
The purpose of this study was to examine the impact attenuation properties of women’s lacrosse headgear and to characterize mechanical properties of the materials of which they are composed. Impacts using a linear impactor (2.2, 2.9, and 5.0 m/s) and a projectile shooter (13.4 and 27.0 m/s) were applied to a Hybrid III 50th male head-neck assembly at six impact locations to replicate realistic women’s lacrosse head impacts. Individual materials that make up the headgear were tested in compression at two quasi-static strain rates, 0.01/s and1/s, and 100/s using uniaxial test machines. For the linear impactor tests, results showed a significant decrease in peak linear and rotational acceleration (PLA and PRA), peak rotational velocity (PRV), head injury criteria and brain injury criteria in the helmeted impacts (p < 0.022). During the ball impacts PRV and PRA were significantly lower for both helmeted conditions compared with no helmet (p < 0.01). Material characterization tests indicated a range of rate effects in these materials ranging from weak to pronounced, and these effects correspondingly influenced the strain energy density graphs. The connection of the materials’ rate effects to the performance of the headgear is described in general and in relation to the impact tests.
- Open Access
- 11 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11  (1) , 1-10
Method for the biomechanical analysis of aqueous veins and perilimbal sclera by three-dimensional photoacoustic imaging and strain field calculation
A method motivated by the eye’s aqueous veins is described for the imaging and strain calculation within soft biological tissues. A challenge to the investigation of the biomechanics of the aqueous vein—perilimbal sclera tissue complex is resolution of tissue deformations as a function of intraocular pressure and the subsequent calculation of strain (a normalized measure of deformation). The method involves perfusion of the eye with a contrast agent during conduction of non-invasive, optical resolution photoacoustic microscopy. This imaging technique permits three-dimensional displacement measurements of tracked points on the inner walls of the veins which are used in a finite element model to determine the corresponding strains. The methods are validated against two standard strain measurement methods. Representative porcine globe perfusion experiments are presented that demonstrate the power of the method to determine complex strain fields in the veins dependent on intraocular pressure as well as vein anatomy. In these cases, veins are observed to move radially outward during increases in intraocular pressure and to possess significant spatial strain variation, possibly influenced by their branching patterns. To the authors’ knowledge, these are the only such quantitative, data driven, calculations of the aqueous vein strains available in the open literature.
- 11 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11  (1) , 1-10
Open AccessMethod for the biomechanical analysis of aqueous veins and perilimbal sclera by three-dimensional photoacoustic imaging and strain field calculation
A method motivated by the eye’s aqueous veins is described for the imaging and strain calculation within soft biological tissues. A challenge to the investigation of the biomechanics of the aqueous vein—perilimbal sclera tissue complex is resolution of tissue deformations as a function of intraocular pressure and the subsequent calculation of strain (a normalized measure of deformation). The method involves perfusion of the eye with a contrast agent during conduction of non-invasive, optical resolution photoacoustic microscopy. This imaging technique permits three-dimensional displacement measurements of tracked points on the inner walls of the veins which are used in a finite element model to determine the corresponding strains. The methods are validated against two standard strain measurement methods. Representative porcine globe perfusion experiments are presented that demonstrate the power of the method to determine complex strain fields in the veins dependent on intraocular pressure as well as vein anatomy. In these cases, veins are observed to move radially outward during increases in intraocular pressure and to possess significant spatial strain variation, possibly influenced by their branching patterns. To the authors’ knowledge, these are the only such quantitative, data driven, calculations of the aqueous vein strains available in the open literature.
- Open Access
- 2 May 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13  (5) , e0195882
Perilimbal sclera mechanical properties: Impact on intraocular pressure in porcine eyes
There is extensive knowledge on the relationship of posterior scleral biomechanics and intraocular pressure (IOP) load on glaucomatous optic neuropathy; however, the role for biomechanical influence of the perilimbal scleral tissue on the aqueous humor drainage pathway, including the distal venous outflow system, and IOP regulation is not fully understood. The purpose of this work is to study the outflow characteristics of perfused porcine eyes relative to the biomechanical properties of the perilimbal sclera, the posterior sclera and the cornea. Enucleated porcine eyes from eleven different animals were perfused with surrogate aqueous at two fixed flow rates while monitoring their IOP. After perfusion, mechanical stress-strain and relaxation tests were conducted on specimens of perilimbal sclera, posterior sclera, and cornea from the same perfused eyes. Statistical analysis of the data demonstrated a strong correlation between increased tangent modulus of the perilimbal sclera tissues and increased perfusion IOP (R2 = 0.74, p = 0.0006 at lower flow rate and R2 = 0.71, p = 0.0011 at higher flow rate). In contrast, there were no significant correlations between IOP and the tangent modulus of the other tissues (Posterior sclera: R2 = 0.17 at lower flow rate and R2 = 0.30 at higher flow rate; cornea: R2 = 0.02 at lower flow rate and R22 ≤ 0.08 in all cases). Additionally, the correlation occurred for IOP and not net outflow facility (R2 ≤ 0.12 in all cases). These results provide new evidence that IOP in perfused porcine eyes is strongly influenced by the tangent modulus, sometimes called the tissue stiffness, of the most anterior portion of the sclera, i.e. the limbus.
- 2 May 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13  (5) , e0195882
Open AccessPerilimbal sclera mechanical properties: Impact on intraocular pressure in porcine eyes
There is extensive knowledge on the relationship of posterior scleral biomechanics and intraocular pressure (IOP) load on glaucomatous optic neuropathy; however, the role for biomechanical influence of the perilimbal scleral tissue on the aqueous humor drainage pathway, including the distal venous outflow system, and IOP regulation is not fully understood. The purpose of this work is to study the outflow characteristics of perfused porcine eyes relative to the biomechanical properties of the perilimbal sclera, the posterior sclera and the cornea. Enucleated porcine eyes from eleven different animals were perfused with surrogate aqueous at two fixed flow rates while monitoring their IOP. After perfusion, mechanical stress-strain and relaxation tests were conducted on specimens of perilimbal sclera, posterior sclera, and cornea from the same perfused eyes. Statistical analysis of the data demonstrated a strong correlation between increased tangent modulus of the perilimbal sclera tissues and increased perfusion IOP (R2 = 0.74, p = 0.0006 at lower flow rate and R2 = 0.71, p = 0.0011 at higher flow rate). In contrast, there were no significant correlations between IOP and the tangent modulus of the other tissues (Posterior sclera: R2 = 0.17 at lower flow rate and R2 = 0.30 at higher flow rate; cornea: R2 = 0.02 at lower flow rate and R22 ≤ 0.08 in all cases). Additionally, the correlation occurred for IOP and not net outflow facility (R2 ≤ 0.12 in all cases). These results provide new evidence that IOP in perfused porcine eyes is strongly influenced by the tangent modulus, sometimes called the tissue stiffness, of the most anterior portion of the sclera, i.e. the limbus.
- 1 July 2014
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 333  (15) , 3356-3366
Damping characteristics of a spray-deposited shape memory alloy beam
- 1 July 2014
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 333  (15) , 3356-3366
Damping characteristics of a spray-deposited shape memory alloy beam
- 22 May 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136  (7) , 071011
Shear Behavior of Bovine Scleral Tissue
Ocular tissue properties have been widely studied in tension and compression for humans and a variety of animals. However, direct shear testing of the tissues of the sclera appear to be absent from the literature even though modeling, analyses, and anatomical studies have indicated that shear may play a role in the etiology of primary open angle glaucoma (POAG). In this work, the mechanical behavior of bovine scleral tissue in shear has been studied in both out-of-plane and in-plane modes of deformation. Stress–strain and relaxation tests were conducted on tissue specimens at controlled temperature and hydration focusing on trends related to specimen location and orientation. There was generally found to be no significant effect of specimen orientation and angular location in the globe on shear stiffness in both modes. The in-plane response, which is the primary load carrying mode, was found to be substantially stiffer than the out-of-plane mode. Also, within the in-plane studies, tissue further from the optic nerve was stiffer than the near tissue. The viscosity coefficient of the tissue varied insignificantly with distance from the optic nerve, but overall was much higher in-plane than out-of-plane.
- 22 May 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136  (7) , 071011
Shear Behavior of Bovine Scleral Tissue
Ocular tissue properties have been widely studied in tension and compression for humans and a variety of animals. However, direct shear testing of the tissues of the sclera appear to be absent from the literature even though modeling, analyses, and anatomical studies have indicated that shear may play a role in the etiology of primary open angle glaucoma (POAG). In this work, the mechanical behavior of bovine scleral tissue in shear has been studied in both out-of-plane and in-plane modes of deformation. Stress–strain and relaxation tests were conducted on tissue specimens at controlled temperature and hydration focusing on trends related to specimen location and orientation. There was generally found to be no significant effect of specimen orientation and angular location in the globe on shear stiffness in both modes. The in-plane response, which is the primary load carrying mode, was found to be substantially stiffer than the out-of-plane mode. Also, within the in-plane studies, tissue further from the optic nerve was stiffer than the near tissue. The viscosity coefficient of the tissue varied insignificantly with distance from the optic nerve, but overall was much higher in-plane than out-of-plane.
- 1 June 2012
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 134  (6) , 061002
Constitutive Behavior of Ocular Tissues Over a Range of Strain Rates
The constitutive behavior of bovine scleral and corneal tissues is measured in tension and compression, at quasi-static and moderate strain rates. Experiments are conducted at strain rates up to about 50 strain per second by a pneumatic testing system developed to overcome noise and measurement difficulties associated with the time dependent test of low impedance materials. Results for the tissues at room and the natural bovine body temperatures are similar and indicate that ocular tissue exhibits nonlinear stiffening for increasing strain rates, a phenomena termed rate hardening. For example, at a tensile strain rate of 29/s, corneal tissue is found to develop 10 times the stress that it does quasi-statically at the same strain. Thus, conventional constitutive models will grossly underpredict stresses occurring in the corneo-scleral shell due to moderate dynamic events. This has implication to the accuracy of ocular injury models, the study of the stress field in the corneo-scleral shell for glaucoma research and tonometry measurements. The measured data at various strain rates is represented using the general framework of a constitutive model that has been used to represent biological tissue mechanical data. Here it is extended to represent the measured data of the ocular tissues over the range of tested strain rates. Its form allows for straightforward incorporation in various numerical codes. The experimental and analytical methods developed here are felt to be applicable to the test of human ocular tissue.
- 1 June 2012
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 134  (6) , 061002
Constitutive Behavior of Ocular Tissues Over a Range of Strain Rates
The constitutive behavior of bovine scleral and corneal tissues is measured in tension and compression, at quasi-static and moderate strain rates. Experiments are conducted at strain rates up to about 50 strain per second by a pneumatic testing system developed to overcome noise and measurement difficulties associated with the time dependent test of low impedance materials. Results for the tissues at room and the natural bovine body temperatures are similar and indicate that ocular tissue exhibits nonlinear stiffening for increasing strain rates, a phenomena termed rate hardening. For example, at a tensile strain rate of 29/s, corneal tissue is found to develop 10 times the stress that it does quasi-statically at the same strain. Thus, conventional constitutive models will grossly underpredict stresses occurring in the corneo-scleral shell due to moderate dynamic events. This has implication to the accuracy of ocular injury models, the study of the stress field in the corneo-scleral shell for glaucoma research and tonometry measurements. The measured data at various strain rates is represented using the general framework of a constitutive model that has been used to represent biological tissue mechanical data. Here it is extended to represent the measured data of the ocular tissues over the range of tested strain rates. Its form allows for straightforward incorporation in various numerical codes. The experimental and analytical methods developed here are felt to be applicable to the test of human ocular tissue.