Matthias Grothoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthias Grothoff has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
- M. Gutberlet
Klinik für Strahlenheilkunde, Charité, Campus Virchow Klinikum, Augustenburger Platz 1, 13353 Berlin
30 shared publications L Lehmkuhl
21 shared publicationsC Lücke
19 shared publications- S Nitzsche15 shared publications
B Foldyna
14 shared publicationsC Andres
9 shared publications
Latest Publications
- 29 March 2016
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 188 (S 01) , WISS302_8
Dynamische CT-Angiografie bei Patienten mit infrarenalem Bauchaortenaneurysma nach endovaskulärer Stentgraftimplantation (EVAR): Klinische Relevanz von Typ-II-Endoleaks im Langzeitverlauf
Zielsetzung: Ziel war es, mittels der für die Endoleak-Detektion sehr sensitiven dynamischen CTA nachzuweisen, welche klinische Relevanz Typ-II-Endoleaks hinsichtlich der Größenentwicklung der Aneurysmasack-Diameter haben und ob stattgehabte Re-Interventionen einen Einfluss auf die Endoleakhäufigkeit haben. Material und Methodik: In diese retrospektive Studie wurden 47 Patienten (75,8 ± 7 Jahre) eingeschlossen, welche in unserer Einrichtung mindestens zwei dynamische CTA der Bauchaorta nach EVAR als klinisch indizierte Verlaufskontrolle erhielten (Siemens Somatom Definition Flash). Es erfolgte im Vergleich mit der initialen dynamischen CTA die Auswertung der Größenentwicklung der Aneurysmasack-Diameter in Abhängigkeit von der Rate an Typ-II-Endoleaks, ferner wurde die Endoleakhäufigkeit in Abhängigkeit von der Reinterventionsquote betrachtet. Ergebnisse: Die mittlere Dauer der Verlaufsbeurteilung betrug 2,46 ± 1,12 Jahre. Vergleicht man progrediente (mittlere Diameterzunahme +6,0 ± 5,1 mm) bzw. progrediente oder konstante (+5,0 ± 5,0 mm) Aneursmagrößenverläufe mit regredienten (-5,0 ± 4,1 mm) Verläufen, so lagen in den ersten beiden Gruppen signifikant mehr Endoleaks vor (50,0 bzw. 54,6%; p = 0,001 bzw. 0,003). Eine Diameterregredienz war nur zu beobachten, wenn kein Endoleak nachweisbar war. Reinterventionen zur Ausschaltung von Endoleaks führten in unserem Patientenkollektiv nicht zu einer niedrigeren Rate an Typ-II-Endoleaks. Schlussfolgerungen: Die mittels der für die Endoleak-Detektion sehr sensitiven dynamischen CTA detektierten Typ-II-Endoleaks nach EVAR sind klinisch relevant, da sie mit einer Größenzunahme des Aneurysmas und somit mit einer steigenden Rupturgefahr vergesellschaftet sind.
- 29 March 2016
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 188 (S 01) , WISS302_8
Dynamische CT-Angiografie bei Patienten mit infrarenalem Bauchaortenaneurysma nach endovaskulärer Stentgraftimplantation (EVAR): Klinische Relevanz von Typ-II-Endoleaks im Langzeitverlauf
Zielsetzung: Ziel war es, mittels der für die Endoleak-Detektion sehr sensitiven dynamischen CTA nachzuweisen, welche klinische Relevanz Typ-II-Endoleaks hinsichtlich der Größenentwicklung der Aneurysmasack-Diameter haben und ob stattgehabte Re-Interventionen einen Einfluss auf die Endoleakhäufigkeit haben. Material und Methodik: In diese retrospektive Studie wurden 47 Patienten (75,8 ± 7 Jahre) eingeschlossen, welche in unserer Einrichtung mindestens zwei dynamische CTA der Bauchaorta nach EVAR als klinisch indizierte Verlaufskontrolle erhielten (Siemens Somatom Definition Flash). Es erfolgte im Vergleich mit der initialen dynamischen CTA die Auswertung der Größenentwicklung der Aneurysmasack-Diameter in Abhängigkeit von der Rate an Typ-II-Endoleaks, ferner wurde die Endoleakhäufigkeit in Abhängigkeit von der Reinterventionsquote betrachtet. Ergebnisse: Die mittlere Dauer der Verlaufsbeurteilung betrug 2,46 ± 1,12 Jahre. Vergleicht man progrediente (mittlere Diameterzunahme +6,0 ± 5,1 mm) bzw. progrediente oder konstante (+5,0 ± 5,0 mm) Aneursmagrößenverläufe mit regredienten (-5,0 ± 4,1 mm) Verläufen, so lagen in den ersten beiden Gruppen signifikant mehr Endoleaks vor (50,0 bzw. 54,6%; p = 0,001 bzw. 0,003). Eine Diameterregredienz war nur zu beobachten, wenn kein Endoleak nachweisbar war. Reinterventionen zur Ausschaltung von Endoleaks führten in unserem Patientenkollektiv nicht zu einer niedrigeren Rate an Typ-II-Endoleaks. Schlussfolgerungen: Die mittels der für die Endoleak-Detektion sehr sensitiven dynamischen CTA detektierten Typ-II-Endoleaks nach EVAR sind klinisch relevant, da sie mit einer Größenzunahme des Aneurysmas und somit mit einer steigenden Rupturgefahr vergesellschaftet sind.
- 29 March 2016
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 188 (S 01) , RK115_5
Diagnostischer Wert von T1- und T2-Mapping zur Differenzialdiagnose bei akutem Koronarsyndrom
Zielsetzung: Den diagnostischen Wert einer mittventrikulären Einzelschicht für die Unterscheidung zwischen einer Takotsubo-Kardiomyopathie und einem akuten Myokardinfarkt zu evaluieren. Material und Methodik: 36 Patienten (18 mit akutem Myokardinfarkt (AMI) und 18 mit Takotsubo-Kardiomyopathie (TTC)) erhielten eine kardiale MRT (Intera 1,5 T System, Philips, Best, Niederlande). T1- und T2-Mapping wurde nativ als mittventrikuläre Kurzachsen-Einzelschicht akquiriert. 10 Minuten nach Gabe von 0.15 mmol Gadobutrol (Gadovist, Bayer Healthcare, Berlin, Germany) wurde das T1 Mapping wiederholt. T1 Mapping wurde mit einer modifizierte Look- Locker Inversion Recovery Sequenz (Sequenzschema 3(3)5), T2 Mapping mit einer Fast Gradient Echo Spin Echo Sequenz akquiriert. Die T1 und T2 Maps wurden dann mittels einer Software (cmr42 (Circle Cardiovascular Imaging Inc, Calgary, Canada) evaluiert. T-Test und eine ROC-Analyse wurden durchgeführt. Ergebnisse: Die native T1 Zeit bei TTC unterschied sich mit 1174 ± 85 ms statistisch signifikant von der bei AMI: 1111 ± 74 ms (p = 0,02). Die T2 Zeit betrug 70 ± 13 ms bei TTC und 62 ± 6 ms bei AMI (p = 0,03). Die T1 Zeit nach KM war nicht statistisch signifikant unterschiedlich mit 324 ± 58 ms bei TTC und 360 ± 127 ms bei AMI. Die AUC für das T2 Mapping betrug 0,7 mit einer Spezifität von 100% und einer Sensitivität von 44% bei einem Cut-off von 73,56 ms. Die native T1 Map wies eine AUC von 0,69 auf, mit einer Sensitivität von 56% und Spezifität von 94% bei einem Cut-off von 1160 ms. Die AUC für die T1 Zeit nach KM Gabe betrug 0,65 mit einer Sensitivität von 67% und einer Spezifität von 72% bei einem Cut-off von 327 ms. Schlussfolgerungen: Native T1- und T2-Zeiten unterscheiden sich signifikant zwischen Patienten mit TTC und AMI. Mittels einer mittventrikulären Einzelschicht T1 und T2 Zeit-Bestimmung gelingt so eine Differenzierung der TTC gegenüber einem AMI mit hoher Spezifität. Dabei weisen natives T1 und T2 Mapping die höchste diagnostische Leistungsfähigkeit auf.
- 29 March 2016
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 188 (S 01) , RK115_5
Diagnostischer Wert von T1- und T2-Mapping zur Differenzialdiagnose bei akutem Koronarsyndrom
Zielsetzung: Den diagnostischen Wert einer mittventrikulären Einzelschicht für die Unterscheidung zwischen einer Takotsubo-Kardiomyopathie und einem akuten Myokardinfarkt zu evaluieren. Material und Methodik: 36 Patienten (18 mit akutem Myokardinfarkt (AMI) und 18 mit Takotsubo-Kardiomyopathie (TTC)) erhielten eine kardiale MRT (Intera 1,5 T System, Philips, Best, Niederlande). T1- und T2-Mapping wurde nativ als mittventrikuläre Kurzachsen-Einzelschicht akquiriert. 10 Minuten nach Gabe von 0.15 mmol Gadobutrol (Gadovist, Bayer Healthcare, Berlin, Germany) wurde das T1 Mapping wiederholt. T1 Mapping wurde mit einer modifizierte Look- Locker Inversion Recovery Sequenz (Sequenzschema 3(3)5), T2 Mapping mit einer Fast Gradient Echo Spin Echo Sequenz akquiriert. Die T1 und T2 Maps wurden dann mittels einer Software (cmr42 (Circle Cardiovascular Imaging Inc, Calgary, Canada) evaluiert. T-Test und eine ROC-Analyse wurden durchgeführt. Ergebnisse: Die native T1 Zeit bei TTC unterschied sich mit 1174 ± 85 ms statistisch signifikant von der bei AMI: 1111 ± 74 ms (p = 0,02). Die T2 Zeit betrug 70 ± 13 ms bei TTC und 62 ± 6 ms bei AMI (p = 0,03). Die T1 Zeit nach KM war nicht statistisch signifikant unterschiedlich mit 324 ± 58 ms bei TTC und 360 ± 127 ms bei AMI. Die AUC für das T2 Mapping betrug 0,7 mit einer Spezifität von 100% und einer Sensitivität von 44% bei einem Cut-off von 73,56 ms. Die native T1 Map wies eine AUC von 0,69 auf, mit einer Sensitivität von 56% und Spezifität von 94% bei einem Cut-off von 1160 ms. Die AUC für die T1 Zeit nach KM Gabe betrug 0,65 mit einer Sensitivität von 67% und einer Spezifität von 72% bei einem Cut-off von 327 ms. Schlussfolgerungen: Native T1- und T2-Zeiten unterscheiden sich signifikant zwischen Patienten mit TTC und AMI. Mittels einer mittventrikulären Einzelschicht T1 und T2 Zeit-Bestimmung gelingt so eine Differenzierung der TTC gegenüber einem AMI mit hoher Spezifität. Dabei weisen natives T1 und T2 Mapping die höchste diagnostische Leistungsfähigkeit auf.
- 1 June 2014
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 271 (3) , 695-702
MR Imaging–guided Electrophysiological Ablation Studies in Humans with Passive Catheter Tracking: Initial Results
Electrophysiological ablation procedures for atrial flutter by using intracardiac MR imaging guidance of the inserted catheters are possible in principle, albeit subject to major limitations in this early stage of evaluation and far from routine clinical use. PurposeTo assess if real-time magnetic resonance (MR) imaging–guided radiofrequency (RF) ablation for atrial flutter is feasible in patients.Materials and MethodsThe study complied with the Declaration of Helsinki and was approved by the local ethics committee. All patients were informed about the investigational nature of the procedures and provided written informed consent. Ten patients (six men; mean age ± standard deviation, 68 years ± 10) with symptomatic atrial flutter underwent isthmus ablation. In all patients, two MR imaging conditional steerable diagnostic and ablation catheters were inserted into the coronary sinus via femoral sheaths and into the right atrium with fluoroscopic guidance. The patients were then transferred to a 1.5-T whole-body MR imager for an ablation procedure, in which the catheters were manipulated by an electrophysiologist by using a commercially available interactive real-time steady-state free precession MR imaging sequence.ResultsAll catheters were placed in standard po...
- 1 June 2014
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 271 (3) , 695-702
MR Imaging–guided Electrophysiological Ablation Studies in Humans with Passive Catheter Tracking: Initial Results
Electrophysiological ablation procedures for atrial flutter by using intracardiac MR imaging guidance of the inserted catheters are possible in principle, albeit subject to major limitations in this early stage of evaluation and far from routine clinical use. PurposeTo assess if real-time magnetic resonance (MR) imaging–guided radiofrequency (RF) ablation for atrial flutter is feasible in patients.Materials and MethodsThe study complied with the Declaration of Helsinki and was approved by the local ethics committee. All patients were informed about the investigational nature of the procedures and provided written informed consent. Ten patients (six men; mean age ± standard deviation, 68 years ± 10) with symptomatic atrial flutter underwent isthmus ablation. In all patients, two MR imaging conditional steerable diagnostic and ablation catheters were inserted into the coronary sinus via femoral sheaths and into the right atrium with fluoroscopic guidance. The patients were then transferred to a 1.5-T whole-body MR imager for an ablation procedure, in which the catheters were manipulated by an electrophysiologist by using a commercially available interactive real-time steady-state free precession MR imaging sequence.ResultsAll catheters were placed in standard po...
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , VO319_1
Prädiktoren für aortale Größenzunahmen
Zielsetzung: Beurteilung aortaler Wachstumsmuster und Identifikation von Einflussgrößen auf die aortale Wachstumsrate in der Computertomografie Material und Methodik: Retrospektiver Einschluss von Verlaufsuntersuchungen bei 73 Patienten (66 ± 8,0 Jahre) mit CT-Angiografien der thorakalen/thorakoabdominellen/abdominellen Aorta. Der mittlere Abstand zwischen der CTA betrug 1,8 ± 0,8 Jahre. Die Aorta wurde vom sinutubulären Übergang bis zur Iliakalbifurkation in 9 Segmente eingeteilt. Insgesamt wurden 346 Aortensegmente zur Messung von potentiellen Einflussgrößen (Volumen, Durchmesser, Länge, Verkalkungsgrad, Verwindung, Wanddicke und -exzentrizität) berücksichtigt. Die pot. Einflussgrößen der initialen Untersuchungen sowie deren errechneten jährlichen Veränderungsraten wurden mit den volumenbasierten Wachstumsraten als Referenz verglichen. Mittels einer multiplen Regressionsanalyse wurden Prädiktoren für eine aortale Volumenzunahme bestätigt. Ergebnisse: Die mittlere jährliche volumenbasierte Wachstumsrate der Aortensegmente betrug 4,9 ± 13,0 cm3 (7,5 ± 20,0%). Unterschiedliche Raten wurden zwischen Thorax/Abdomen und aneurysmatischen/nicht-aneurysmatischen Segmenten gefunden. Folgende signifikante (p = 0,05) Korrelationen der initialen pot. Einflussgrößen mit den relativen volumenbasierten Wachstumsraten wurden gefunden: Durchmesser-Längen-Verhältnis (r = 0,30), maximale/minimale Wandstärke (r = 0,27/0,25), maximaler Durchmesser (r = 0,25), Tortuositätsindex (r =-0,19). Höhere Korrelationen wurden für Veränderungsraten der pot. Einflussgrößen wie Segmentlänge (r = 0,62), Gesamt-/Wand/Lumenvolumen (r = 0,58/0,51/0,47), Durchmesser-Längenverhältnis (r =-0,46), maximaler Durchmesser (r = 0,44), maximale Wandstärke (r = 0,37) und TortuositätsiIndex (r = 0,20). Die multiple Regressionsanalyse ergab fünf Gruppen von Prädiktoren: Größe, Längenwachstum, thrombotische/atherosklerotische Wandveränderung, Querschnitts-Exzentrizität und Tortuosität. Schlussfolgerungen: Aortale Größenzunahmen sind heterogen und bedürfen einer umfassenden, über eine Diametermessung hinausgehende Beurteilung. Insbesondere das Längenwachstum sollte in der täglichen Routine zusätzlich berücksichtigt werden. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , VO319_1
Prädiktoren für aortale Größenzunahmen
Zielsetzung: Beurteilung aortaler Wachstumsmuster und Identifikation von Einflussgrößen auf die aortale Wachstumsrate in der Computertomografie Material und Methodik: Retrospektiver Einschluss von Verlaufsuntersuchungen bei 73 Patienten (66 ± 8,0 Jahre) mit CT-Angiografien der thorakalen/thorakoabdominellen/abdominellen Aorta. Der mittlere Abstand zwischen der CTA betrug 1,8 ± 0,8 Jahre. Die Aorta wurde vom sinutubulären Übergang bis zur Iliakalbifurkation in 9 Segmente eingeteilt. Insgesamt wurden 346 Aortensegmente zur Messung von potentiellen Einflussgrößen (Volumen, Durchmesser, Länge, Verkalkungsgrad, Verwindung, Wanddicke und -exzentrizität) berücksichtigt. Die pot. Einflussgrößen der initialen Untersuchungen sowie deren errechneten jährlichen Veränderungsraten wurden mit den volumenbasierten Wachstumsraten als Referenz verglichen. Mittels einer multiplen Regressionsanalyse wurden Prädiktoren für eine aortale Volumenzunahme bestätigt. Ergebnisse: Die mittlere jährliche volumenbasierte Wachstumsrate der Aortensegmente betrug 4,9 ± 13,0 cm3 (7,5 ± 20,0%). Unterschiedliche Raten wurden zwischen Thorax/Abdomen und aneurysmatischen/nicht-aneurysmatischen Segmenten gefunden. Folgende signifikante (p = 0,05) Korrelationen der initialen pot. Einflussgrößen mit den relativen volumenbasierten Wachstumsraten wurden gefunden: Durchmesser-Längen-Verhältnis (r = 0,30), maximale/minimale Wandstärke (r = 0,27/0,25), maximaler Durchmesser (r = 0,25), Tortuositätsindex (r =-0,19). Höhere Korrelationen wurden für Veränderungsraten der pot. Einflussgrößen wie Segmentlänge (r = 0,62), Gesamt-/Wand/Lumenvolumen (r = 0,58/0,51/0,47), Durchmesser-Längenverhältnis (r =-0,46), maximaler Durchmesser (r = 0,44), maximale Wandstärke (r = 0,37) und TortuositätsiIndex (r = 0,20). Die multiple Regressionsanalyse ergab fünf Gruppen von Prädiktoren: Größe, Längenwachstum, thrombotische/atherosklerotische Wandveränderung, Querschnitts-Exzentrizität und Tortuosität. Schlussfolgerungen: Aortale Größenzunahmen sind heterogen und bedürfen einer umfassenden, über eine Diametermessung hinausgehende Beurteilung. Insbesondere das Längenwachstum sollte in der täglichen Routine zusätzlich berücksichtigt werden. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , RK_VO201_3
Interobservervariabilität von T1- und T2-Mapping Sequenzen der kardialen MRT bei Patienten mit klinischem Verdacht auf Myokarditis
Zielsetzung: Bestimmung der Interobserver-Variabilität des myokardialen T2- sowie T1-Mappings vor und nach Kontrastmittelgabe bei Patienten mit klinischem Verdacht auf Myokarditis. Die in den Lake-Louise-Kriterien beschriebenen qualitativen MR-Methoden für die Detektion einer myokardialen Entzündung, der relative Wassergehalt (ER) und das globale Relative Enhancement (gRE), weisen eine sehr hohe Interobserver-Variabilität auf. Mapping Techniken mit einem quantitativen Ansatz könnten hier eventuell Abhilfe schaffen. Material und Methodik: 27 Patienten (17 männlich, 10 weiblich; Alter 49 Jahre ± 19) mit klinischem Verdacht auf Myokarditis unterzogen sich einer kardialen Magnetresonanztomografie (cMRT) an einem 1,5T Gerät (Gyroscan Intera CV, Philips Medical Systems, Best, Niederlande). Die cMRT umfasste mittventrikuläre Einzelschicht T1 Maps vor (T1nativ) und nach (T1KM) Kontrastmittelgabe (TR = 2,75 – 2,9 ms, TE = 1,38 –1,45 ms, TI = 168 – 6659 ms, Schichtdicke = 10 mm, FOV = 380 × 380 mm, Matrix = 320 × 320) sowie native T2 Maps (T2) (TR = 545,45 – 1200 ms, TE = 11,66 – 48,27 ms, TI = 250 ms, Schichtdicke = 8 mm, FOV = 370× 370 mm, Matrix = 384 × 384) in Kurzachsenorientierung. Interobserver-Korrelationen und Bland-Altman-Plots wurden erstellt. Ergebnisse: Die Korrelation der Beobachter war bei allen drei Mapping-Sequenzen (T1nativ, T1KM, T2) sehr hoch (r = 0,97, r = 0,99 und r = 0,98) und zeigte einen nur geringen Interobserver-Bias (bias T1nativ = 5,1 ms, bias T1KM =-1,3 ms und bias T2 =-0,3 ms) mit schmalen „Limits of Agreement“ im Bland-Altman-Plot (LOA T1nativ =-45,9 und 56,2 ms, LOA T1KM =-15,5 und 12,9 ms und LOA T2 =-2,5 ms und 1,8 ms). Schlussfolgerungen: Das myokardiale T1-Mapping vor und nach Kontrastmittelgabe und das native T2-Mapping weisen eine sehr niedrige Interobserver-Variabilität auf und könnten damit in Zukunft als untersucherunabhängigere MRT-Techniken im Vergleich zu den Lake-Louise-Kriterien zur besseren Erkennung von Patienten mit Myokarditis beitragen. E-Mail: cluecke
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , RK_VO201_3
Interobservervariabilität von T1- und T2-Mapping Sequenzen der kardialen MRT bei Patienten mit klinischem Verdacht auf Myokarditis
Zielsetzung: Bestimmung der Interobserver-Variabilität des myokardialen T2- sowie T1-Mappings vor und nach Kontrastmittelgabe bei Patienten mit klinischem Verdacht auf Myokarditis. Die in den Lake-Louise-Kriterien beschriebenen qualitativen MR-Methoden für die Detektion einer myokardialen Entzündung, der relative Wassergehalt (ER) und das globale Relative Enhancement (gRE), weisen eine sehr hohe Interobserver-Variabilität auf. Mapping Techniken mit einem quantitativen Ansatz könnten hier eventuell Abhilfe schaffen. Material und Methodik: 27 Patienten (17 männlich, 10 weiblich; Alter 49 Jahre ± 19) mit klinischem Verdacht auf Myokarditis unterzogen sich einer kardialen Magnetresonanztomografie (cMRT) an einem 1,5T Gerät (Gyroscan Intera CV, Philips Medical Systems, Best, Niederlande). Die cMRT umfasste mittventrikuläre Einzelschicht T1 Maps vor (T1nativ) und nach (T1KM) Kontrastmittelgabe (TR = 2,75 – 2,9 ms, TE = 1,38 –1,45 ms, TI = 168 – 6659 ms, Schichtdicke = 10 mm, FOV = 380 × 380 mm, Matrix = 320 × 320) sowie native T2 Maps (T2) (TR = 545,45 – 1200 ms, TE = 11,66 – 48,27 ms, TI = 250 ms, Schichtdicke = 8 mm, FOV = 370× 370 mm, Matrix = 384 × 384) in Kurzachsenorientierung. Interobserver-Korrelationen und Bland-Altman-Plots wurden erstellt. Ergebnisse: Die Korrelation der Beobachter war bei allen drei Mapping-Sequenzen (T1nativ, T1KM, T2) sehr hoch (r = 0,97, r = 0,99 und r = 0,98) und zeigte einen nur geringen Interobserver-Bias (bias T1nativ = 5,1 ms, bias T1KM =-1,3 ms und bias T2 =-0,3 ms) mit schmalen „Limits of Agreement“ im Bland-Altman-Plot (LOA T1nativ =-45,9 und 56,2 ms, LOA T1KM =-15,5 und 12,9 ms und LOA T2 =-2,5 ms und 1,8 ms). Schlussfolgerungen: Das myokardiale T1-Mapping vor und nach Kontrastmittelgabe und das native T2-Mapping weisen eine sehr niedrige Interobserver-Variabilität auf und könnten damit in Zukunft als untersucherunabhängigere MRT-Techniken im Vergleich zu den Lake-Louise-Kriterien zur besseren Erkennung von Patienten mit Myokarditis beitragen. E-Mail: cluecke
- 1 January 2014
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 62 (S 01) , OP86
Bicuspidalization of the native tricuspid Aortic Valve: A new experimental model to isolate the effect of altered 'Flow-Architecture' on Ascending/Root Disease
Objectives: Bicuspid Aortic Valve (BAV) is associated with a significantly higher risk of ascending aortic/root pathologies at a young age. Previously, associated aortic wall alterations were thought to be of genetic origin but more recently altered flow architecture has been suggested the major culprit. We present the first large animal model to experimentally isolate the effect of flow phenomena through the BAV from possible genetic factors. Methods: Six juvenile pigs underwent CPB and open aortic valve (AV) surgery for cusp fusion (5-7 Prolene (7 x 0) stiches) to bicuspidalize the native tricuspid aortic valve. The two most common Sievers types-1L-R (∼75% of the general BAV population) and Sievers type I R-N (∼20%) were generated for further flow simulation (Fig.1). All pigs underwent a pre- and postoperative 4D-MRI to gather raw data for visualization of changes in flow architecture and dynamics and altered pressure profiles within the wall of the ascending aorta/root. Results: After bicuspidalization of the AV typical vortex formation and changed wall pressure profiles could be seen in the ascending aorta/aortic root. No severe artificial stenosis was created by this procedure with invasively measured transvalvular gradients over the AV in both SIEVERS types of 15 ± 5 mmHg. No significant flow alteration but normalized laminar flow was present again downstream, in the distal aortic arch /proximal descending (Fig.1). Conclusions: We present the first large animal model that allows for the systematic analysis of the primary effects of altered flow architecture-isolated from possible genetic factors-caused by BAV of separate Sievers types. With low transvalvular gradients and negligible degree of stenosis, long-term evaluation of various helical flow patterns on changes in wall enzyme activity, smooth muscle cell function and structural transformation of the extracellular matrix possibly resulting in aneurysm formation or triggering acute dissection will be feasible.
- 1 January 2014
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 62 (S 01) , OP86
Bicuspidalization of the native tricuspid Aortic Valve: A new experimental model to isolate the effect of altered 'Flow-Architecture' on Ascending/Root Disease
Objectives: Bicuspid Aortic Valve (BAV) is associated with a significantly higher risk of ascending aortic/root pathologies at a young age. Previously, associated aortic wall alterations were thought to be of genetic origin but more recently altered flow architecture has been suggested the major culprit. We present the first large animal model to experimentally isolate the effect of flow phenomena through the BAV from possible genetic factors. Methods: Six juvenile pigs underwent CPB and open aortic valve (AV) surgery for cusp fusion (5-7 Prolene (7 x 0) stiches) to bicuspidalize the native tricuspid aortic valve. The two most common Sievers types-1L-R (∼75% of the general BAV population) and Sievers type I R-N (∼20%) were generated for further flow simulation (Fig.1). All pigs underwent a pre- and postoperative 4D-MRI to gather raw data for visualization of changes in flow architecture and dynamics and altered pressure profiles within the wall of the ascending aorta/root. Results: After bicuspidalization of the AV typical vortex formation and changed wall pressure profiles could be seen in the ascending aorta/aortic root. No severe artificial stenosis was created by this procedure with invasively measured transvalvular gradients over the AV in both SIEVERS types of 15 ± 5 mmHg. No significant flow alteration but normalized laminar flow was present again downstream, in the distal aortic arch /proximal descending (Fig.1). Conclusions: We present the first large animal model that allows for the systematic analysis of the primary effects of altered flow architecture-isolated from possible genetic factors-caused by BAV of separate Sievers types. With low transvalvular gradients and negligible degree of stenosis, long-term evaluation of various helical flow patterns on changes in wall enzyme activity, smooth muscle cell function and structural transformation of the extracellular matrix possibly resulting in aneurysm formation or triggering acute dissection will be feasible.
- 1 October 2013
- Vol. 185 (10) , 941-9
Role of preprocedural computed tomography in transcatheter aortic valve implantation.
Transcatheter aortic valve implantation (TAVI) is currently considered an acceptable alternative for the treatment of patients with severe aortic stenosis and a high perioperative risk or a contraindication for open surgery. The benefit of TAVI significantly outweighs the risk of the procedure in patients requiring treatment that are not suitable for open surgery, and leads to a lower mortality in the one-year follow-up. The absence of a direct view of the aortic root and valve remains a challenge for the transcatheter approach. While direct inspection of the aortic valve during open surgery allows an adequate prosthesis choice, it is crucial for TAVI to know the individual anatomical details prior to the procedure in order to assure adequate planning of the procedure and proper prosthesis choice and patient selection. Among the imaging modalities available for the evaluation of patients prior to TAVI, computed tomography (CT) plays a central role in patient selection. CT reliably visualizes the dimensions of the aortic root and allows a proper choice of the prosthesis size. The morphology of the access path and relevant comorbidities can be assessed. The present review summarizes the current state of knowledge regarding the value of CT in the evaluation of patients prior to TAVI. CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. CT provides a more accurate measurement of the aortic annulus than 2D TEE and CT is the only imaging modality that allows a risk assessment for paravalvular leakages based on the calcification of the aortic valve.
- 1 October 2013
- Vol. 185 (10) , 941-9
Role of preprocedural computed tomography in transcatheter aortic valve implantation.
Transcatheter aortic valve implantation (TAVI) is currently considered an acceptable alternative for the treatment of patients with severe aortic stenosis and a high perioperative risk or a contraindication for open surgery. The benefit of TAVI significantly outweighs the risk of the procedure in patients requiring treatment that are not suitable for open surgery, and leads to a lower mortality in the one-year follow-up. The absence of a direct view of the aortic root and valve remains a challenge for the transcatheter approach. While direct inspection of the aortic valve during open surgery allows an adequate prosthesis choice, it is crucial for TAVI to know the individual anatomical details prior to the procedure in order to assure adequate planning of the procedure and proper prosthesis choice and patient selection. Among the imaging modalities available for the evaluation of patients prior to TAVI, computed tomography (CT) plays a central role in patient selection. CT reliably visualizes the dimensions of the aortic root and allows a proper choice of the prosthesis size. The morphology of the access path and relevant comorbidities can be assessed. The present review summarizes the current state of knowledge regarding the value of CT in the evaluation of patients prior to TAVI. CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. CT provides a more accurate measurement of the aortic annulus than 2D TEE and CT is the only imaging modality that allows a risk assessment for paravalvular leakages based on the calcification of the aortic valve.
- 26 April 2013
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 185 (S 01) , VO206_4
Vergleich von 4D und 2D Phasenkontrast-Flussmessungen der großen mediastinalen Gefäße im MRT
Ziele: 2D Phasenkontrast-Flussmessungen ermöglichen die nichtinvasive Messung von Flussvolumina und Spitzengeschwindigkeiten. Sie sind ein wichtiger Bestandteil in der Diagnostik und Verlaufskontrolle bei Patienten mit angeborenen oder erworbenen Herzerkrankungen. Die Planung und wiederholte Akquisition von 2D Messungen an verschiedenen Gefäßen ist jedoch zeitaufwändig, und die Analyse ist auf die Areale beschränkt, welche während der Untersuchung aufgenommen wurden. 4D Flussmessungen ermöglichen eine Beurteilung der Flussverhältnisse im Bereich der Herzklappen und der mediastinalen Gefäße mittels einer Messung. Das Ziel unserer Studie war es, 4D Flussmessungen mit der etablierten 2D Technik zu vergleichen und die Anwendbarkeit der 4D Technik zu testen. Methode: 3 Probanden und 10 Patienten wurden in die Studie eingeschlossen. 2D Flussmessungen wurden an einem 1,5 Tesla oder 3 Tesla MR-Gerät durchgeführt. Die 4D Flussmessungen wurden am 3 Tesla Gerät durchgeführt. Die statistische Analyse umfasste den Wilcoxon Test, eine Korrelationsanalyse, eine lineare Regressionsanalyse und Bland-Altman Plots. Ergebnis: Flussvolumina wurden mit 2D und 4D Messungen in 25 Positionen bestimmt. Es zeigte sich eine gute Übereinstimmung ohne signifikante Unterschiede (p = 0,16). Die Korrelationsanalyse ergab eine starke Korrelation mit r = 0,9. Der Korrelationskoeffizient für den Vorwärtsfluss betrug 0,6 und für den Rückwärtsfluss 1,0. Spitzengeschwindigkeiten wurden mit 2D und 4D Messungen in 21 Positionen bestimmt. Es ergaben sich keine signifikanten Unterschiede (p = 0,054) und eine gute Korrelation (r = 0,8). Die Bland-Altman Tests zeigten eine gute Übereinstimmung für Flussvolumina und Spitzengeschwindigkeiten. Quotienten des pulmonalen und aortalen Schlagvolumens zeigten bei 3 Probanden konsistente Werte für 2D und 4D Flussmessungen. Schlussfolgerung: 4D Phasenkontrast-Flussmessungen sind geeignet für die klinische Anwendung und zeigen eine gute Übereinstimmung mit den etablierten 2D-Flussmessungen. Korrespondierender Autor: Preim U Herzzentrum Leipzig, Universitätsklinikum, Radiologie, Strümpellstraße 39, 04289 Leipzig E-Mail: [email protected]
- 26 April 2013
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 185 (S 01) , VO206_4
Vergleich von 4D und 2D Phasenkontrast-Flussmessungen der großen mediastinalen Gefäße im MRT
Ziele: 2D Phasenkontrast-Flussmessungen ermöglichen die nichtinvasive Messung von Flussvolumina und Spitzengeschwindigkeiten. Sie sind ein wichtiger Bestandteil in der Diagnostik und Verlaufskontrolle bei Patienten mit angeborenen oder erworbenen Herzerkrankungen. Die Planung und wiederholte Akquisition von 2D Messungen an verschiedenen Gefäßen ist jedoch zeitaufwändig, und die Analyse ist auf die Areale beschränkt, welche während der Untersuchung aufgenommen wurden. 4D Flussmessungen ermöglichen eine Beurteilung der Flussverhältnisse im Bereich der Herzklappen und der mediastinalen Gefäße mittels einer Messung. Das Ziel unserer Studie war es, 4D Flussmessungen mit der etablierten 2D Technik zu vergleichen und die Anwendbarkeit der 4D Technik zu testen. Methode: 3 Probanden und 10 Patienten wurden in die Studie eingeschlossen. 2D Flussmessungen wurden an einem 1,5 Tesla oder 3 Tesla MR-Gerät durchgeführt. Die 4D Flussmessungen wurden am 3 Tesla Gerät durchgeführt. Die statistische Analyse umfasste den Wilcoxon Test, eine Korrelationsanalyse, eine lineare Regressionsanalyse und Bland-Altman Plots. Ergebnis: Flussvolumina wurden mit 2D und 4D Messungen in 25 Positionen bestimmt. Es zeigte sich eine gute Übereinstimmung ohne signifikante Unterschiede (p = 0,16). Die Korrelationsanalyse ergab eine starke Korrelation mit r = 0,9. Der Korrelationskoeffizient für den Vorwärtsfluss betrug 0,6 und für den Rückwärtsfluss 1,0. Spitzengeschwindigkeiten wurden mit 2D und 4D Messungen in 21 Positionen bestimmt. Es ergaben sich keine signifikanten Unterschiede (p = 0,054) und eine gute Korrelation (r = 0,8). Die Bland-Altman Tests zeigten eine gute Übereinstimmung für Flussvolumina und Spitzengeschwindigkeiten. Quotienten des pulmonalen und aortalen Schlagvolumens zeigten bei 3 Probanden konsistente Werte für 2D und 4D Flussmessungen. Schlussfolgerung: 4D Phasenkontrast-Flussmessungen sind geeignet für die klinische Anwendung und zeigen eine gute Übereinstimmung mit den etablierten 2D-Flussmessungen. Korrespondierender Autor: Preim U Herzzentrum Leipzig, Universitätsklinikum, Radiologie, Strümpellstraße 39, 04289 Leipzig E-Mail: [email protected]
- 26 April 2013
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 185 (S 01) , VO206_3
Vergleich der Funktionsanalyse von synchron akquirierten Hybrid-PET-MRT-Daten
Ziele: Die MRT ist der Goldstandard zur Beurteilung der kardialen Funktion. Auch mittels PET ist eine Funktionsbestimmung möglich, mit guter Korrelation zur MRT bei sequentieller Durchführung. Unser Ziel war es, die kardiale Funktion an synchron akquirierten Datensätzen zu bestimmen und zu vergleichen. Methode: Es wurde bei 10 Patienten (8 männlich, 2 weiblich, mittleres Alter 48 +/- 18 Jahre), die zuvor eine PET-CT aufgrund einer anderen klinischen Fragestellung erhalten haben, eine simultan akquirierte Herz-PET/MRT-Untersuchung (Biograph mMR, Siemens, Erlangen) mit der Restaktivität der vorangegangenen Untersuchung durchgeführt. Die PET-Akquisitionszeit betrug 15 min. Simultan wurden Standard-Cine-Sequenzen (SSFP) in Zwei- und Vier-Kammer- sowie Kurzachsen-Orientierung durchgeführt. Die PET- und MRT-Daten wurden von zwei, jeweils verblindeten Untersuchern ausgewertet. Es wurden das enddiastolische (EDV) und endsystolische Volumen (ESV), die Ejektionsfraktion (EF) sowie die Wandmasse (LVWM) des linken Ventrikels bestimmt. Der Pearson-Korrelationskoeffizient (r) wurde bestimmt und eine Bland-Altman-Analyse durchgeführt. Ergebnis: Der Vergleich zeigte eine gute Korrelation der kardialen Funktionsparameter (EDV: r = 0,94; ESV: r = 0,88; LVWM: r = 0,71; EF: r = 0,72). Das EDV wurde im Mittel mittels PET 5 ml (+/- 8 ml, p = 0,67) größer bestimmt, das ESV wurde gleich groß gemessen (0 ml +/- 7 ml, p = 0,99). Auch die EF zeigte mit 1% (+/- 7%) zugunsten des MRT keinen signifikanten Unterschied zwischen den beiden Methoden (p = 0,78). Die LVWM wurde im PET 19 g (+/- 15 g, pSchlussfolgerung: Bei simultan akquirierten kardialen PET/MR-Daten stimmen EDV, ESV und EF sehr gut überein. Lediglich die LVWM zeigt einen statistisch signifikanten Unterschied zugunsten des PET von im Mittel 14%. Korrespondierender Autor: Lücke C Universität Leipzig – Herzzentrum, Abt. für Diagnostische und Interventionelle Radiologie, Strümpellstr. 39, 04289 Leipzig E-Mail: [email protected]
- 26 April 2013
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 185 (S 01) , VO206_3
Vergleich der Funktionsanalyse von synchron akquirierten Hybrid-PET-MRT-Daten
Ziele: Die MRT ist der Goldstandard zur Beurteilung der kardialen Funktion. Auch mittels PET ist eine Funktionsbestimmung möglich, mit guter Korrelation zur MRT bei sequentieller Durchführung. Unser Ziel war es, die kardiale Funktion an synchron akquirierten Datensätzen zu bestimmen und zu vergleichen. Methode: Es wurde bei 10 Patienten (8 männlich, 2 weiblich, mittleres Alter 48 +/- 18 Jahre), die zuvor eine PET-CT aufgrund einer anderen klinischen Fragestellung erhalten haben, eine simultan akquirierte Herz-PET/MRT-Untersuchung (Biograph mMR, Siemens, Erlangen) mit der Restaktivität der vorangegangenen Untersuchung durchgeführt. Die PET-Akquisitionszeit betrug 15 min. Simultan wurden Standard-Cine-Sequenzen (SSFP) in Zwei- und Vier-Kammer- sowie Kurzachsen-Orientierung durchgeführt. Die PET- und MRT-Daten wurden von zwei, jeweils verblindeten Untersuchern ausgewertet. Es wurden das enddiastolische (EDV) und endsystolische Volumen (ESV), die Ejektionsfraktion (EF) sowie die Wandmasse (LVWM) des linken Ventrikels bestimmt. Der Pearson-Korrelationskoeffizient (r) wurde bestimmt und eine Bland-Altman-Analyse durchgeführt. Ergebnis: Der Vergleich zeigte eine gute Korrelation der kardialen Funktionsparameter (EDV: r = 0,94; ESV: r = 0,88; LVWM: r = 0,71; EF: r = 0,72). Das EDV wurde im Mittel mittels PET 5 ml (+/- 8 ml, p = 0,67) größer bestimmt, das ESV wurde gleich groß gemessen (0 ml +/- 7 ml, p = 0,99). Auch die EF zeigte mit 1% (+/- 7%) zugunsten des MRT keinen signifikanten Unterschied zwischen den beiden Methoden (p = 0,78). Die LVWM wurde im PET 19 g (+/- 15 g, pSchlussfolgerung: Bei simultan akquirierten kardialen PET/MR-Daten stimmen EDV, ESV und EF sehr gut überein. Lediglich die LVWM zeigt einen statistisch signifikanten Unterschied zugunsten des PET von im Mittel 14%. Korrespondierender Autor: Lücke C Universität Leipzig – Herzzentrum, Abt. für Diagnostische und Interventionelle Radiologie, Strümpellstr. 39, 04289 Leipzig E-Mail: [email protected]
- Open Access
- 10 July 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (12) , 2699-2709
Value of cardiovascular MR in diagnosing left ventricular non-compaction cardiomyopathy and in discriminating between other cardiomyopathies
Objectives To analyse the value of cardiovascular magnetic resonance (CMR)-derived myocardial parameters to differentiate left ventricular non-compaction cardiomyopathy (LVNC) from other cardiomyopathies and controls. Methods We retrospectively analysed 12 patients with LVNC, 11 with dilated and 10 with hypertrophic cardiomyopathy and compared them to 24 controls. LVNC patients had to fulfil standard echocardiographic criteria as well as additional clinical and imaging criteria. Cine steady-state free precession and late gadolinium enhancement (LGE) imaging was performed. The total LV myocardial mass index (LV-MMI), compacted (LV-MMIcompacted), non-compacted (LV-MMInon-compacted), percentage LV-MMnon-compacted, ventricular volumes and function were calculated. Data were compared using analysis of variance and Dunnett’s test. Additionally, semi-quantitative segmental analyses of the occurrence of increased trabeculation were performed. Results Total LV-MMInon-compacted and percentage LV-MMnon-compacted were discriminators between patients with LVCN, healthy controls and those with other cardiomyopathies with cut-offs of 15 g/m2 and 25 %, respectively. Furthermore, trabeculation in basal segments and a ratio of non-compacted/compacted myocardium of ≥3:1 were criteria for LVNC. A combination of these criteria provided sensitivities and specificities of up to 100 %. None of the LVNC patients demonstrated LGE. Conclusions Absolute CMR quantification of the LV-MMInon-compacted or the percentage LV-MMnon-compacted and increased trabeculation in basal segments allows one to reliably diagnose LVNC and to differentiate it from other cardiomyopathies. Key Points • Cardiac magnetic resonance imaging can reliably diagnose left ventricular non-compaction cardiomyopathy. • Differentiation of LVNC from other cardiomyopathies and normal hearts is possible. • The best diagnostic performance can be achieved if combined MRI criteria for the diagnosis are used.
- 10 July 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (12) , 2699-2709
Open AccessValue of cardiovascular MR in diagnosing left ventricular non-compaction cardiomyopathy and in discriminating between other cardiomyopathies
Objectives To analyse the value of cardiovascular magnetic resonance (CMR)-derived myocardial parameters to differentiate left ventricular non-compaction cardiomyopathy (LVNC) from other cardiomyopathies and controls. Methods We retrospectively analysed 12 patients with LVNC, 11 with dilated and 10 with hypertrophic cardiomyopathy and compared them to 24 controls. LVNC patients had to fulfil standard echocardiographic criteria as well as additional clinical and imaging criteria. Cine steady-state free precession and late gadolinium enhancement (LGE) imaging was performed. The total LV myocardial mass index (LV-MMI), compacted (LV-MMIcompacted), non-compacted (LV-MMInon-compacted), percentage LV-MMnon-compacted, ventricular volumes and function were calculated. Data were compared using analysis of variance and Dunnett’s test. Additionally, semi-quantitative segmental analyses of the occurrence of increased trabeculation were performed. Results Total LV-MMInon-compacted and percentage LV-MMnon-compacted were discriminators between patients with LVCN, healthy controls and those with other cardiomyopathies with cut-offs of 15 g/m2 and 25 %, respectively. Furthermore, trabeculation in basal segments and a ratio of non-compacted/compacted myocardium of ≥3:1 were criteria for LVNC. A combination of these criteria provided sensitivities and specificities of up to 100 %. None of the LVNC patients demonstrated LGE. Conclusions Absolute CMR quantification of the LV-MMInon-compacted or the percentage LV-MMnon-compacted and increased trabeculation in basal segments allows one to reliably diagnose LVNC and to differentiate it from other cardiomyopathies. Key Points • Cardiac magnetic resonance imaging can reliably diagnose left ventricular non-compaction cardiomyopathy. • Differentiation of LVNC from other cardiomyopathies and normal hearts is possible. • The best diagnostic performance can be achieved if combined MRI criteria for the diagnosis are used.