Åke Stenholm
Åke Stenholm has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Ola Lind
Research & Development, GE Healthcare , Bio-Sciences AB , Björkgatan 30, S-751 84 Uppsala , Sweden
3 shared publicationsSandra Hjärthag
Research & Development, GE Healthcare , Bio-Sciences AB , Björkgatan 30, S-751 84 Uppsala , Sweden
2 shared publicationsSara Holmström
Cardinova AB, Ullforsgatan 15 , S-752 28 Uppsala , Sweden
2 shared publicationsA. Ragnarsson
General Electric Healthcare
1 shared publicationBo Wigilius
ALcontrol Laboratories , PO Box 1083, Linköping, Sweden
1 shared publicationEmma Eriksson
General Electric Healthcare, Life Sciences , SE-751 84 Uppsala, Sweden
1 shared publication
Latest Publications
- 19 September 2012
- Published by Wiley in Phytochemical Analysis
- Vol. 24 (2) , 176-183
Bioassay‐guided Supercritical Fluid Extraction of Cyclooxygenase‐2 Inhibiting Substances in Plantago major L.
Introduction: Selective extraction of plant materials is advantageous for obtaining extracts enriched with desired constituents, thereby reducing the need for subsequent chromatography purification. Such compounds include three cyclooxygenase‐2 (COX‐2) inhibitory substances in Plantago major L. targeted in this investigation: α‐linolenic acid (α‐LNA) (18:3 ω‐3) and the triterpenic acids ursolic acid and oleanolic acid.Objective: To investigate the scope for tuning the selectivity of supercritical fluid extraction (SFE) using bioassay guidance, and Soxhlet extraction with dichloromethane as solvent as a reference technique, to optimise yields of these substances.Method: Extraction parameters were varied to optimise extractsʼ COX‐2/COX‐1 inhibitory effect ratios. The crude extracts were purified initially using a solid phase extraction (SPE) clean‐up procedure and the target compounds were identified with GC‐MS, LC‐ESI‐MS and LC‐ESI‐MS2 using GC‐FID for quantification.Results: α‐LNA was preferentially extracted in dynamic mode using unmodified carbon dioxide at 40°C and 172 bar, at a 0.04% (w/w) yield with a COX‐2/COX‐1 inhibitory effect ratio of 1.5. Ursolic and oleanolic acids were dynamically extracted at 0.25% and 0.06% yields, respectively, with no traces of (α‐LNA) and a COX‐2/COX‐1‐inhibitory effect ratio of 1.1 using 10% (v/v) ethanol as polar modifier at 75°C and 483 bar. The Soxhlet extracts had ursolic acid, oleanolic acid and αLNA yields up to 1.36%, 0.34% and 0.15%, respectively, with a COX‐2/COX‐1 inhibitory effect ratio of 1.2.Conclusion: The target substances can be extracted selectively by bioassay guided optimisation of SFE conditions. Copyright © 2012 John Wiley & Sons, Ltd.
- 19 September 2012
- Published by Wiley in Phytochemical Analysis
- Vol. 24 (2) , 176-183
Bioassay‐guided Supercritical Fluid Extraction of Cyclooxygenase‐2 Inhibiting Substances in Plantago major L.
Introduction: Selective extraction of plant materials is advantageous for obtaining extracts enriched with desired constituents, thereby reducing the need for subsequent chromatography purification. Such compounds include three cyclooxygenase‐2 (COX‐2) inhibitory substances in Plantago major L. targeted in this investigation: α‐linolenic acid (α‐LNA) (18:3 ω‐3) and the triterpenic acids ursolic acid and oleanolic acid.Objective: To investigate the scope for tuning the selectivity of supercritical fluid extraction (SFE) using bioassay guidance, and Soxhlet extraction with dichloromethane as solvent as a reference technique, to optimise yields of these substances.Method: Extraction parameters were varied to optimise extractsʼ COX‐2/COX‐1 inhibitory effect ratios. The crude extracts were purified initially using a solid phase extraction (SPE) clean‐up procedure and the target compounds were identified with GC‐MS, LC‐ESI‐MS and LC‐ESI‐MS2 using GC‐FID for quantification.Results: α‐LNA was preferentially extracted in dynamic mode using unmodified carbon dioxide at 40°C and 172 bar, at a 0.04% (w/w) yield with a COX‐2/COX‐1 inhibitory effect ratio of 1.5. Ursolic and oleanolic acids were dynamically extracted at 0.25% and 0.06% yields, respectively, with no traces of (α‐LNA) and a COX‐2/COX‐1‐inhibitory effect ratio of 1.1 using 10% (v/v) ethanol as polar modifier at 75°C and 483 bar. The Soxhlet extracts had ursolic acid, oleanolic acid and αLNA yields up to 1.36%, 0.34% and 0.15%, respectively, with a COX‐2/COX‐1 inhibitory effect ratio of 1.2.Conclusion: The target substances can be extracted selectively by bioassay guided optimisation of SFE conditions. Copyright © 2012 John Wiley & Sons, Ltd.
- 1 January 2012
- Published by Taylor & Francis in Environmental Technology
- Vol. 33 (2) , 129-141
Strategies for selecting optimal sampling and work-up procedures for analyzing alkylphenol polyethoxylates in effluents from non-activated sludge biofilm reactors
Trace-level analysis of alkylphenol polyethoxylates (APEOs) in wastewater containing sludge requires the prior removal of contaminants and preconcentration. In this study, the effects of the types of alkylphenols present, their degree of ethoxylation, the biofilm-wastewater treatment and sample matrix were investigated on optimal work-up procedures for these purposes. The spot for sampling APEO-containing specimens from an industrial wastewater treatment plant was optimized, and boxed round the tubing carrying the wastewater to prevent sedimented sludge contaminating the collected samples. Following these changes, the sampling precision (in terms of dry matter content) at a point just under the tubing leading from the biofilm reactors was 0.7 % RSD. The findings were applied to develop a work-up procedure for use prior to a high-performance liquid chromatography-fluorescence detection analysis method capable of quantifying nonylphenol polyethoxylates (NPEOs) and poorly investigated dinonylphenol polyethoxylates (DNPEOs) at low μg L−1 concentrations in effluents from non-activated sludge biofilm reactors. The selected multistep work-up procedure includes lyophilization and pressurized fluid extraction (PFE) followed by strong ion exchange solid phase extraction (SPE). The yields of the combined procedure, according to tests with NP10EO-spiked WWTP-derived wastewaters, were in the 62–78 % range.
- 1 January 2012
- Published by Taylor & Francis in Environmental Technology
- Vol. 33 (2) , 129-141
Strategies for selecting optimal sampling and work-up procedures for analyzing alkylphenol polyethoxylates in effluents from non-activated sludge biofilm reactors
Trace-level analysis of alkylphenol polyethoxylates (APEOs) in wastewater containing sludge requires the prior removal of contaminants and preconcentration. In this study, the effects of the types of alkylphenols present, their degree of ethoxylation, the biofilm-wastewater treatment and sample matrix were investigated on optimal work-up procedures for these purposes. The spot for sampling APEO-containing specimens from an industrial wastewater treatment plant was optimized, and boxed round the tubing carrying the wastewater to prevent sedimented sludge contaminating the collected samples. Following these changes, the sampling precision (in terms of dry matter content) at a point just under the tubing leading from the biofilm reactors was 0.7 % RSD. The findings were applied to develop a work-up procedure for use prior to a high-performance liquid chromatography-fluorescence detection analysis method capable of quantifying nonylphenol polyethoxylates (NPEOs) and poorly investigated dinonylphenol polyethoxylates (DNPEOs) at low μg L−1 concentrations in effluents from non-activated sludge biofilm reactors. The selected multistep work-up procedure includes lyophilization and pressurized fluid extraction (PFE) followed by strong ion exchange solid phase extraction (SPE). The yields of the combined procedure, according to tests with NP10EO-spiked WWTP-derived wastewaters, were in the 62–78 % range.
- 7 October 2009
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 64 (10) , 1047-1053
Total nitrogen in wastewater analysis: Comparison of Devarda’s alloy method and high temperature oxidation followed by chemiluminescence detection
Two methods for determining total nitrogen (TN) contents of complex wastewaters were compared: Devarda’s alloy method and a method involving high temperature oxidation (HTO) followed by chemiluminescence detection (CLD). In the latter multiple standard additions were used for quantification purposes since the CLD response was found to be dependent on the structure of the analysed nitrogen-containing compounds. For both methods, sample dilution steps were necessary to achieve acceptable accuracy. The accuracies for selected compounds used in tests were within the 65–105% range. In a long-term interlaboratory investigation the HTO-CLD method yielded significantly (p < 0.05) higher results than Devarda’s alloy method and greater precision (within-assay repeatability approximately 1% RSD, while the corresponding within-day repeatability for Devarda’s alloy method was approximately 7% RSD).
- 7 October 2009
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 64 (10) , 1047-1053
Total nitrogen in wastewater analysis: Comparison of Devarda’s alloy method and high temperature oxidation followed by chemiluminescence detection
Two methods for determining total nitrogen (TN) contents of complex wastewaters were compared: Devarda’s alloy method and a method involving high temperature oxidation (HTO) followed by chemiluminescence detection (CLD). In the latter multiple standard additions were used for quantification purposes since the CLD response was found to be dependent on the structure of the analysed nitrogen-containing compounds. For both methods, sample dilution steps were necessary to achieve acceptable accuracy. The accuracies for selected compounds used in tests were within the 65–105% range. In a long-term interlaboratory investigation the HTO-CLD method yielded significantly (p < 0.05) higher results than Devarda’s alloy method and greater precision (within-assay repeatability approximately 1% RSD, while the corresponding within-day repeatability for Devarda’s alloy method was approximately 7% RSD).
- 1 October 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (41) , 6974-6977
Development of a high-performance liquid chromatography-fluorescence detection method for analyzing nonylphenol/dinonylphenol-polyethoxylate-based phosphate esters
- 1 October 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (41) , 6974-6977
Development of a high-performance liquid chromatography-fluorescence detection method for analyzing nonylphenol/dinonylphenol-polyethoxylate-based phosphate esters
- 15 February 2008
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 88 (3) , 165-176
Comparison of continuous flow analysis including photometric detection and ion-selective electrode potentiometry for the measurement of ammonium nitrogen in wastewater
Continuous flow analysis (CFA) with photometric detection is widely used to quantify . However, low-molecular-weight amines interfere with CFA measurements. Therefore, we compared CFA and ion-selective electrode (ISE) measurements using an ISE25NH4 electrode from Radiometer Analytical for determining in wastewater streams in a plant where protein separation media are manufactured. Approximately 50% of the trimethylammonium chloride in one of the samples was recorded by CFA as ammonium nitrogen. Furthermore, CFA spikings using 6 mg N/L additions to the wastewater showed less accuracy compared with equivalent ISE spikings. Direct ISE measurements of levels in wastewater across the concentration range 0.1–1400 mg N/L typically showed >90% accuracy, with + (logK NH4 − N, NaPot) = –3.11, the presence of potentially interfering Na+ ions in selected wastewaters did not affect the readings. ISE measurements obtained by multiple standard addition methodology showed similar levels of accuracy and repeatability, except that the accuracy of the determinations was affected by the non-linear electrode responses to samples with low concentrations (p < 0.05). The ISE results showed on average 18 and 112% higher concentrations compared with CFA results. The known occasional ammonium increase in one of the streams was not detected by the CFA method.
- 15 February 2008
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 88 (3) , 165-176
Comparison of continuous flow analysis including photometric detection and ion-selective electrode potentiometry for the measurement of ammonium nitrogen in wastewater
Continuous flow analysis (CFA) with photometric detection is widely used to quantify . However, low-molecular-weight amines interfere with CFA measurements. Therefore, we compared CFA and ion-selective electrode (ISE) measurements using an ISE25NH4 electrode from Radiometer Analytical for determining in wastewater streams in a plant where protein separation media are manufactured. Approximately 50% of the trimethylammonium chloride in one of the samples was recorded by CFA as ammonium nitrogen. Furthermore, CFA spikings using 6 mg N/L additions to the wastewater showed less accuracy compared with equivalent ISE spikings. Direct ISE measurements of levels in wastewater across the concentration range 0.1–1400 mg N/L typically showed >90% accuracy, with + (logK NH4 − N, NaPot) = –3.11, the presence of potentially interfering Na+ ions in selected wastewaters did not affect the readings. ISE measurements obtained by multiple standard addition methodology showed similar levels of accuracy and repeatability, except that the accuracy of the determinations was affected by the non-linear electrode responses to samples with low concentrations (p < 0.05). The ISE results showed on average 18 and 112% higher concentrations compared with CFA results. The known occasional ammonium increase in one of the streams was not detected by the CFA method.
- 22 September 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1128 (1-2) , 73-78
Comparison of amine-selective properties of weak and strong cation-exchangers
- 22 September 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1128 (1-2) , 73-78
Comparison of amine-selective properties of weak and strong cation-exchangers