ALAlexander Lembcke

Alexander Lembcke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander Lembcke has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accuracy of coronary artery calcium scoring with tube current reduction by 75%, using an adaptive iterative reconstruction algorithm

    by Reny Luhur, Joanne D Schuijf, Jürgen Mews, Jörg Blobel, Bernd Hamm, Alexander Lembcke

    Objective: To assess the accuracy of an iterative reconstruction (IR) technique for coronary artery calcium scoring with reduced radiation dose. Methods: 163 consecutive patients underwent twofold scanning by 320-row detector CT at 120 kVp. A low-dose scan at 25% tube current but with standard scan length (14 cm) was followed by a standard dose scan with routine tube current but reduced scan length (10 cm). Reduced dose images were constructed using filtered back-projection (FBP) and IR (adaptive iterative dose reduction in three dimensions). The standard dose scan reconstructed with FBP served as the gold standard for comparisons. Image noise and Agatston coronary calcium scores were determined and compared between the groups. Results: Compared with FBP at standard dose, noise at reduced dose increased markedly with FBP but remained low with IR. Mean Agatston score with FBP at reduced dose showed a significant increase as compared with FBP at standard dose. No significant difference was observed when applying IR at reduced dose. At reduced dose, 38 (23.3%) patients were reassigned to a different cardiovascular risk category with FBP but only 8 (4.9%) with IR. Out of 47 patients with a zero Agatston score, 15 patients (31.9%) were false-positive with FBP at reduced dose, but no false positives were found with IR. Conclusion: IR allows accurate coronary artery calcium scoring with a radiation dose reduced by 75%. Advances in knowledge: The application of adaptive iterative dose reduction in three dimensions allows the maintenance of accurate Agatston scores and risk stratification at significantly reduced tube current, thus reducing the patient’s exposure to ionizing radiation.


  • Systemic embolization with coronary artery obstruction from a left ventricular thrombus

    by Alexander Lembcke, Matthias Rief, Sascha Treskatsch, Simon Dushe


    • 1 September 2013
      • Vol. 22  (5) , 751-3

    Surgical-transcatheter approach for endocarditis of a calcified aortic homograft.

    by Herko Grubitzsch, Michael Laule, Karl Stangl, Alexander Lembcke, Michael Sander, Torsten Christ, Wolfgang Konertz

    Repeat aortic valve replacement (AVR) after freestanding homograft root replacement with reimplantation of the coronary arteries is challenging and risky, especially in patients with major homograft wall calcifications. Although new transcatheter techniques for AVR may offer an alternative in structurally degenerated homografts, they are not suitable to treat endocarditis. Here, the case is reported of successful treatment of bacterial endocarditis within a totally calcified homograft after aortic root replacement by combining conventional surgery and transcatheter techniques.


  • High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    by Alexander Lembcke, Carsten Schwenke, Patrick A. Hein, Gesine Knobloch, Tahir Durmus, Bernd Hamm, Alexander Huppertz

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65–85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m2) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G30, 30 mL; G40, 40 mL; G50, 50 mL; G60, 60 mL; G70, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G30 to 478.2 and 571.8 HU in G70. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G30, G40, G50, G60 and G70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. • High-pitch dual-source coronary angiography is feasible with low contrast media volumes. • Traditional injection rules still apply: higher volumes result in higher enhancement. • The patient’s gender is a co-factor determining the level of contrast enhancement. • Volumes can be reduced down to 30–40 mL in selected patients.


  • Assessment of Mitral Valve Stenosis by Helical MDCT: Comparison With Transthoracic Doppler Echocardiography and Cardiac Catheterization

    by Alexander Lembcke, Tahir Durmus, Yvonne Westermann, Anja Geigenmueller, Benjamin Claus, Craig Butler, Holger Thiele

    OBJECTIVE. We evaluated the precision of helical MDCT for the quantification of mitral valve stenosis (MVS) compared with transthoracic echocardiography (TTE) and cardiac catheterization. MATERIALS AND METHODS. A total of 28 patients with MVS of differing severity underwent an ECG-gated contrast-enhanced MDCT scan. The mitral valve area (MVA) was determined planimetrically by MDCT and was compared with Doppler TTE using the pressure half-time method and with cardiac catheterization using the Gorlin formula. RESULTS. Planimetry of the MVA with MDCT was feasible in all cases. The MVA on MDCT (1.88 ± 0.76 cm2) was significantly larger than that seen with TTE (1.74 ± 0.75 cm2; p = 0.039) or cardiac catheterization (1.72 ± 0.67 cm2; p = 0.037). The correlation between MDCT and TTE (r = 0.90; p < 0.001; limits of agreement, ± 0.65 cm2) and that between MDCT and cardiac catheterization (r = 0.86; p < 0.001; limits of agreement, ± 0.76 cm2) were good and similar to the correlation between TTE and cardiac catheter...


  • Strahlenexposition in der CT-Koronarangiographie – Lässt sich die Dosis reduzieren?

    by A Lembcke, P Hein, P Rogalla

    Die kardiale Computertomographie hat sich in den letzten Jahren zu Primärdiagnostik der koronaren Herzerkrankung etabliert. Grundsätzlich muss die kardiale CT -wie jede Anwendung ionisierender Strahlung in der Medizin- jedoch nicht nur gerechtfertigt sein (Rechtfertigungsgebot) sondern auch mit optimaler Strahlenexposition erfolgen (Optimierungsgebot). Besondere Bedeutung kommt zudem der engen direkten Beziehung zwischen Strahlenexposition und Bildgüte zu. So muss einerseits eine unnötig hohe Exposition ohne entsprechenden zusätzlichen diagnostischen Nutzen ebenso vermieden werden wie eine suboptimale oder gar nicht-diagnostische Bildqualität (beispielsweise infolge zu hohen Bildrauschens oder relevanter Bewegungsartefakte) aufgrund zu niedriger bzw. zu kurzer Exposition. Verschiedene Ansätze zur Verringerung der Exposition werden mit ihren Vor- und Nachteilen erörtert. Dabei werden spezifische Akquisitionstechniken der kardialen CT („Step-and-Shoot-, High-Pitch-, and Volume-Imaging“) besprochen welche ein hohes Datenoversampling vermeiden und somit zu einer Dosisreduktion führen. Außerdem wird auf die Wahl geeigneter Untersuchungsparameter (Röhrenstrom, Röhrenspannung, Belichtungszeit) in Abhängigkeit von patientenspezifischen Einflussgrößen und der klinischen Fragestellung eingegangen. Lernziele: Die Qualität einer kardialen CT sollte nicht nur durch Bildgüte (vor allem die konturscharfe und rauscharme Abbildung der Koronararterien) definiert werden, sondern auch durch die Strahlendosis mit der diese Bildgüte erreicht wurde. Als optimal kann eine Bildgüte dann definiert werden, wenn diese mit niedrigster Strahlenexposition erzielt wurde, aber dennoch ein höchstes Maß an diagnostischer Genauigkeit bietet. Mit den neuesten Generationen von CT-Geräten, einer optimalen Patientenvorbereitung und der Wahl geeigneter Akquisitionsprotokolle ist eine exzellente Abbildung der Koronararterien mit einer effektiven Dosis von deutlich weniger als 1 mSv möglich. Korrespondierender Autor: Lembcke A Institut für Radiologie, Charitéplatz 1, 10117 Berlin E-Mail: Alexander.Lembcke@gmx.de

  • Grundlagen der Herzbildgebung mit der Mehrschichtcomputertomographie

    by K Schubert, A Lembcke

    Dieses Klinikseminar dient dazu die Teilnehmer/innen mit den Besonderheiten der Herzbildgebung mit der Computertomographie vertraut zu machen und dabei insbesondere die Anforderungen an Ortsauflösung, Zeitauflösung und Untersuchungsdauer hervorzuheben. Der Zusammenhang von Anatomie und Physiologie des Herzens und den technischen Erfordernissen an den Scanner insbesondere im Hinblick auf Detektorkonfiguration, EKG-Synchronisation und Gantryrotationsgeschwindigkeit wird dargelegt. Die Prinzipien der verschiedenen Akquisitionstechniken (prospektive EKG-Triggerung vs. retrospektives EKG-Gating) werden mit ihren Vor- und Nachteilen erörtert sowie verschiedene Möglichkeiten zur Reduktion der Strahlenexposition besprochen. Erwähnung finden auch die Anwendung verschiedener Medikamente (Beta-Blocker, Nitrate) im Rahmen der Patientenvorbereitung, die Wahl des geeigneten Kontrastmittel-injektionsprotokolls sowie die Grundzüge der Bildnachverarbeitung und -auswertung. Lernziele: Für eine detailgetreue und artefaktfreie Bildgebung des Herzens, insbesondere der Koronararterien ist neben der EKG-Synchronisation der Datenakquisition eine hohe Orts- und Zeitauflösung und möglichst kurze Scandauer anzustreben. Zur Reduktion der Strahlenexposition kommen sowohl Änderungen von Röhrenstrom- und -spannung als auch die Wahl der geeigneten Akquisitionstechnik (prospektive EKG-Triggerung mit punktueller Belichtung) in Betracht. Die Applikation von Betablockern und Nitraten sowie die Anwendung optimierter Kontrastmittelinjektionsprotokolle kann entscheidend zur Verbesserung der Bildqualität und Steigerung der diagnostischen Sicherheit beitragen. Korrespondierender Autor: Lembcke A Institut für Radiologie, Charitéplatz 1, 10117 Berlin E-Mail: Alexander.Lembcke@gmx.de

    • 1 September 2009
      • Vol. 10  (9) , 947-54

    The usefulness of coronary artery calcium scoring and computed tomography angiography to detect patients at high-risk for coronary heart disease.

    by Alexander Lembcke

    Cardiac CT scanning, such as coronary artery calcium (CAC) scoring and multislice CT angiography (CTA), allows the direct visualization of coronary atherosclerosis. CT is a non-invasive test that provides information on stenosis severity and composition, as well as the cumulative burden of coronary plaques. The detection of subclinical coronary plaques is increasingly recognized as an important estimator of risk, with high, independent correlation to future adverse cardiac events. Both CAC scoring and CTA can be used clinically for cardiovascular risk assessment and the investigation of chest-pain syndromes. For either of these indications, CT is most effective when applied to the majority of cardiac patients with intermediate cardiovascular risk. The effectiveness of CT is based on the likelihood that CAC scoring and CTA will modify clinical decision-making in patients with different pre-test risk categories, and on the ability of CT to identify patients with hemodynamically relevant stenoses, as well as patients at high risk for future hard cardiovascular events (eg, cardiac death and non-fatal acute myocardial infarction).