ELEberhard Ludewig

Eberhard Ludewig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eberhard Ludewig has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Klinisches Bild und Diagnostik des angeborenen portosystemischen Shunts beim Hund

    by Ingmar Kiefer, Beate Bosch, Claudia Köhler, Franziska Eberhardt, Eberhard Ludewig

    Im Gegensatz zum Menschen, bei dem ein erworbener portosystemischer Shunt meist nur sekundär durch Erkrankungen der Leber auftritt, kommt der portosystemische Shunt beim Hund öfter angeboren als erworben vor. Die Häufigkeit der Erkrankung wird kritisch diskutiert. Man geht jedoch von einer erheblichen Dunkelziffer aus, insbesondere weil die Symptome mannigfaltig sind und die Ausprägung sehr unterschiedlich ist. Die Erkrankung zählt zu den beim Hund beschriebenen Erbkrankheiten.


  • Effect of Ventral Slot Procedure on Spinal Cord Compression in Dogs with Single Static Intervertebral Disc Disease: Preliminary Findings while Evaluating a Semiquantitative Computed Tomographic Myelographic Score of Spinal Cord Compression

    by Peter Böttcher, Irene Christine Böttcher, Katrin Truar, Eberhard Ludewig, Gerhard Oechtering, Thomas Flegel

    Objective To (1) evaluate pre- and postoperative cervical spinal cord compression (SCC) in the context of uncomplicated ventral slot (VS) decompression using computed tomographic (CT) myelography and (2) report reliability of a semiquantitative SCC score using CT myelography. Study Design Prospective and retrospective, clinical pilot study. Animals Dogs (n = 17) with single static intervertebral disc disease. Methods On matched pre- and postoperative transverse CT myelographic images, degree and lateralization of extradural SCC were scored by 4 blinded independent observers, followed by consensus finding. Inter- and intraobserver variability was quantified using intraclass correlation (ICC). Nonparametric tests were performed comparing pre- and postoperative SCC, correlation with neurologic status and significance of lateralization. Results Because of invisible contrast agent, only 13 dogs could be fully evaluated. After VS, SCC was significantly reduced whereas neurologic function significantly improved. Ten dogs had residual compression, not affecting neurologic long-term outcome. Only preoperative compression score and neurologic status 3–7 weeks postoperatively were inversely correlated. Lateralization of SCC preoperatively did not affect postsurgical compression scores. Interobserver ICC was 0.848 and intraobserver ICC was 0.984. Conclusions VS improves neurologic function but often fails at completely resolving extradural SCC. The proposed CT myelographic score is highly reliable, assuring consistency among and within observers.


    • 15 December 2010
      • Vol. 123, 506-15

    [Dose measurement in small animal radiology: how intense is the influence of distance and position of the investigator in relation to the patient?].

    by Eberhard Ludewig, Astrid Gensler, Gerhard Oechtering, Dieter Gosch

    Radiation exposure of body parts of persons, needed to restrain small animal during the examination, varies depending on the distance and position in relation to the patient, the region investigated, and the exposure settings applied. The aim of the study was to quantify the effects of these factors on the ambient dose. The dosimeter was positioned with varying distance from the direct beam (from 30 to 150 cm) and on different level above the floor (55 cm, 85 cm, and 150 cm. The study consisted of two parts. In the first part a plastic water tank (thickness: 18 cm) was used as source of scatter radiation. Different exposure settings (77 kVp; 20 - 10 - 5 - 2.5 - 1.25 mAs) were applied. In the second part dose was measured during the examination of the abdomen of a large dog (thickness: 18 cm; 77 kVp, 20 mAs) and of the skull of a cat (thickness: 6 cm; 55 kVp, 20 mAs). At the level of the patient (85 cm above the floor) the dose decline relative to the distance followed a quadratic function. In the series "abdomen-dog" the mean dose values ranged from 51.6 microSv (30 cm distance) to 1.02 microSv (150 cm distance). The corresponding doses for the series "skull-cat" were 0.98 microSv and 0.02 microSv, respectively. Comparably lower doses were measured on the lines along the table, when non-irradiated parts of the body were located between the exposed patient volume and the dosimeter. At 150 cm above the floor higher doses were observed relative to the doses at the level of the table. The following conclusions can be drawn: (1.) Depending on the target volume the ambient dose varies in a wide range. (2.) An increase of the distance of only few centimetres is reducing exposure considerably. Therefore persons should make use of it whenever this is possible. (3.) Persons should stand on the short sides of the table while fixing the patient. (4.) Head and neck are relatively highly exposed. Methods to protect the thyroid gland and the eye lens are indicated. (5.) Since different exposure levels can be applied in digital radiography, the range of dose levels is rather wide. Therefore strict dose discipline (e.g. by use of exposure tables and dose indicators) is necessary to avoid continuing overexposure.

  • Open Access

    DISPLAY QUALITY OF DIFFERENT MONITORS IN FELINE DIGITAL RADIOGRAPHY

    by Eberhard Ludewig, Christian Boeltzig, Katrin Gäbler, Anja Werrmann, Gerhard Oechtering

    In human medical imaging, the performance of the monitor used for image reporting has a substantial impact on the diagnostic performance of the entire digital system. Our purpose was to compare the display quality of different monitors used in veterinary practice. Two medical‐grade gray scale monitors (one cathode‐ray tube [CRT], one liquid crystal display [LCD]) and two standard consumer‐grade color monitors (one CRT, one LCD) were compared in the ability to display anatomic structures in cats. Radiographs of the stifle joint and the thorax of 30 normal domestic shorthair cats were acquired by use of a storage phosphor system. Two anatomic features of the stifle joint and five anatomic structures of the thorax were evaluated. The two medical‐grade monitors had superior display quality compared with standard PC monitors. No differences were seen between the monochrome monitors. In comparison with the color CRT, the ratings of the color LCD were significantly worse. The ranking order was uniform for both the region and the criteria investigated. Differences in monitor luminance, bit depth, and screen size were presumed to be the reasons for the observed varying performance. The observed differences between monitors place an emphasis on the need for guidelines defining minimum requirements for the acceptance of monitors and for quality control in veterinary radiography.


    • 26 May 2010
      • Vol. 123, 177-85

    [Comparative radiography of the respiratory tract of snakes using conventional high-resolution film-screen-system and a digital detector system].

    by Michael Pees, Monika Bochmann, Maria-Elisabeth Krautwald-Junghanns, Volker Schmidt, Eberhard Ludewig

    A conventional high-resolution screen-film-system (film Kodak MIN-R S, screen Kodak MIN-R 2000) was compared to a digital detector system (Varian PaxScan 4030E) for the evaluation of the respiratory tract in snakes. Digital radiographs were taken with the same dose as well as with half the dose used for the conventional radiographs. A total of 20 Burmese pythons (Python molurus) were examined in dorsoventral and lateral projection. Four criteria (three features, one overall assessment) were defined for each of the anatomical structures lung, trachea and spinal column and assessed by five veterinarians in a semi-blinded study using a score system. Comparison of the ratings between the techniques used was done using a visual grading analysis. For the lung, two of the three features as well as the overall assessment were rated significantly superior using the digital system. The trachea was rated significantly superior using the conventional system for the overall assessment as well as for one feature. For the spinal column, the overall assessment was significantly superior using the digital system with the full dose. Conventional radiography as well as digital radiography using half the dose was rated significantly inferior for one feature each. The of the relatively low-contrast respiratory tract. A limiting factor is the demonstration of particularly small structures. Generally, a dose reduction (compared to a conventional high-resolution film-screen-system) is possible for the evaluation of the respiratory system.


  • Diagnostic imaging – evaluating image quality using visual grading characteristic (VGC) analysis

    by Eberhard Ludewig, Andreas Richter, Mairi Frame

    Radiologists are regularly faced with the task of comparing image quality obtained using different imaging systems or settings. Visual grading techniques can be used to evaluate the quality of images by grading the clarity of reproduction of anatomical or pathological structures. The methods, which include “visual grading analysis (VGA)” and the “image criteria (IC) study”, are characterised by their attractive simplicity and reliability. Non-parametric rank-invariant statistical methods are suitable techniques for statistical analysis of VGA-data. Båth and Månsson (2007) introduced such a method and termed it “visual grading characteristics (VGC) analysis”. This paper gives an overview of the principle together with an example of its use in veterinary radiology. The aim of this review article is to encourage veterinary researchers to apply this method which has proven valuable in the human field. Basically, the method can also be applied for the analysis of other categories of images (e.g. histological sections, cytological smears) in cases where the task is to evaluate features subjectively on the basis of a score, allowing some degree of freedom of decision. Furthermore, the aim of the investigation is not necessarily restricted to quality aspects. Other questions such as the effects of treatment options on the appearance of certain structures can be compared as well.


  • Untersuchungen zur Bildqualität von Thoraxaufnahmen von Katzen mit einem Needle-Image Plate (NIP) Detektor – ein Modell zur Bewertung der Bildqualität bei Neugeborenen

    by E Ludewig, W Hirsch, K Gäbler, B Bosch, I Sorge, D Succow, A Werrmann, D Gosch

    Ziele: Mit den Untersuchungen am Tiermodell sollten zwei Fragen geklärt werden: 1. Ist bei der Darstellung von Thoraxstrukturen von Katzen eine Überlegenheit des auf einer Nadelkristallstruktur basierenden Speicherfoliensystems (needle image plate, NIP) gegenüber einem konventionellen Speicherfoliensystem (powder image plate, PIP) nachweisbar? 2. Kann mit dem NIP-Detektor das mAs-Produkt ohne Verlust an diagnostischer Information halbiert werden? Methode: Von 20 Tieren wurden je drei seitliche Thoraxaufnahmen angefertigt. Die Belichtungsdaten orientierten sich an den generierten lgM-Werten. Es wurden Aufnahmen (1.) mit dem NIP-Detektor und einer Belichtung, die einem lgM-Wert von 1,9 entsprach, (2.) mit einem PIP-System bei identischer Belichtung und (3.) mit dem NIP-Detektor bei halbiertem mAs-Produkt erzeugt. Sechs verblindete Untersucher beurteilten mittels 5stufiger Skala fünf anatomische Strukturen sowie den Rauscheindruck. Die Daten wurden mittels Visual Grading Characteristics Analyse (VGC) ausgewertet. Die berechneten Flächen unter den VGC-Kurven (AUC) dienen als Maßzahlen dem relativen Vergleich der Bildqualitäten der untersuchten Systeme. Ergebnis: Bei der Verwendung gleicher Belichtungsparameter wurden alle Bildmerkmale der Bilder des NIP-Systems besser bewertet (AUC-Werte zwischen 0,81 für „Herzschatten“ und 0,92 für „Trachea“). Auch bei 50%iger Reduktion der Aufnahmedosis sind die Bewertungen für alle Bildmerkmale besser als beim Einsatz des PIP-Detektors mit der Ausgangsbelichtung (AUC-Werte zwischen 0,60 für „Herzschatten“ und 0,74 für „Trachea“ und „kaudales Thoraxfeld“). Schlussfolgerung: Der NIP-Detektor zeigt im Vergleich mit dem als Referenzsystem dienendem PIP-System deutlich überlegene Abbildungseigenschaft. Eine 50%ige Dosisreduktion ohne relevanten Verlust an Information ist erreichbar. Es kann davon ausgegangen werden, dass die Ergebnisse des Tiermodells auf die Verhältnisse in der pädiatrischen Praxis bei Neugeborenen übertragbar sind. Korrespondierender Autor: Ludewig E Klinik für Kleintiere, Universität Leipzig, An den Tierkliniken 23, 04288 Leipzig E-Mail: ludewig@vetmed.uni-leipzig.de

  • Untersuchungen zur Qualität von Thoraxaufnahmen bei Katzen mit einem auf einer Nadelstruktur basierenden Speicherfoliensystem – Modelluntersuchungen zur Bewertung der Bildqualität bei Neugeborenen

    by E. Ludewig, W. Hirsch, B. Bosch, K. Gäbler, I. Sorge, D. Succow, A. Werrmann, D. Gosch

    Ziel: Ist das auf einer Nadelstruktur basierende Speicherfoliensystem (NIP) bei der Darstellung von Thoraxstrukturen von Katzen dem konventionellen Referenzsystem (PIP) überlegen? Kann mit dem NIP-Detektor das mAs-Produkt ohne Verlust an Information halbiert werden? Material und Methoden: Von 20 Tieren wurden je drei seitliche Thoraxaufnahmen angefertigt. Die Belichtungsdaten orientierten sich an den generierten lgM-Werten. Es wurden Aufnahmen 1. mit dem NIP-Detektor und einer Belichtung, die einem lgM-Wert von 1,9 entsprach, 2. mit einem PIP-System bei identischer Belichtung und 3. mit dem NIP-Detektor bei halbiertem mAs-Produkt erzeugt. Sechs verblindete Untersucher beurteilten mittels 5-stufiger Skala fünf anatomische Strukturen sowie den Rauscheindruck. Die Daten wurden mittels Visual Grading Characteristics Analyse (VGC) ausgewertet. Ergebnisse: Bei der Verwendung gleicher Belichtungsparameter wurden alle Bildmerkmale der Bilder des NIP-Systems besser bewertet (AUCVGC-Werte zwischen 0,81 für „Herzschatten” und 0,92 für „Trachea”). Auch bei 50 %iger Reduktion der Aufnahmedosis sind die Bewertungen für alle Bildmerkmale besser als beim Einsatz des PIP-Detektors mit der Ausgangsbelichtung (AUCVGC-Werte zwischen 0,60 für „Herzschatten” und 0,74 für „Trachea” und „kaudales Thoraxfeld”). Schlussfolgerungen: Der NIP-Detektor zeigt im Vergleich mit dem als Referenzsystem dienendem PIP-System deutlich überlegene Abbildungseigenschaften. Eine 50 %ige Dosisreduktion ohne relevanten Verlust an Information ist erreichbar. Es kann davon ausgegangen werden, dass die Ergebnisse des Tiermodells auf die Verhältnisse in der pädiatrischen Praxis bei Neugeborenen übertragbar sind. Purpose: Is the image quality of thoracic radiographs of cats obtained with a needle-based storage phosphor (NIP) system superior to conventional (PIP) storage phosphor radiography? Is it possible to decrease the mAs by 50 % with the NIP system without significant loss of information? Materials and Methods: From each of the 20 animals, three lateral radiographs were acquired. The assessment of the exposure level was based on the generated lgM-values. Images were acquired 1. with the NIP system and exposure settings equivalent to an lgM of 1.9, 2. with the PIP system and identical settings, and 3. with the NIP system and 50 % of the mAs. Six blinded readers used a 5-step scale to assess the reproducibility of five anatomical structures and image noise sensation. Data were analysed using Visual Grading Characteristics Analysis (VGC). Results: While applying identical exposure values the NIP system for all features revealed superior ratings to those of the PIP system (AUCVGC values ranged from 0.81 for ”cardiac silhouette” to 0.92 for ”trachea”). Even when reducing mAs by 50 % in the NIP images all features were rated better compared with the PIP images and original settings (AUCVGC values ranged from 0.60 for ”cardiac silhouette” to 0.74 for ”trachea” and ”caudal thoracic field”). Conclusion: The NIP system demonstrates clearly better image quality compared to the reference PIP system. A dose reduction of 50 % seems to be possible without relevant detraction from image quality. The results obtained in the animal model are valid for simulating conditions in neonatal radiological practise.


  • Einsatz der digitalen Röntgentechnik bei Reptilien und Vögeln

    by Michael Pees, Monika Bochmann, Eberhard Ludewig

    Immer häufiger stellt sich in der tierärztlichen Praxis die Frage nach der Umrüstung auf digitale Röntgentechnik. Die Vorteile der höheren Effizienz und geringeren Verbrauchskosten sind bekannt. Dem gegenüber stehen hohe Anfangsinvestitionskosten. Inwieweit lassen sich aber mit dem digitalen Verfahren auch bei Vögeln, Reptilien und anderen Heimtieren ausreichende und vergleichbare Ergebnisse erzielen?