Dai Gil Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dai Gil Lee has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Jin Gyu Kim
School of Mechanical Aerospace & Systems Engineering, Korea Advanced Institute of Science and Technology , ME3221 Guseong-dong, Yuseong-gu , Daejeon , 305-701 , Republic of Korea
5 shared publicationsSang Wook Park
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, ME3221, Guseong-dong, Yuseong-gu, Daejeon 305-701, Republic of Korea
4 shared publicationsSoon Ho Yoon
Department of Mechanical Engineering , Korea Advanced Institute of Science and Technology , ME3221, Guseong-dong, Yuseong-gu, Daejeon , 305-701 , Republic of Korea
4 shared publications- Hak-Sung Kim
Department of Mechanical Engineering, Hanyang University, Seoul, Republic of Korea
3 shared publications Ilbeom Choi
Korea Adv Inst Sci & Technol, Dept Mech Engn, ME3221,Guseong Dong, Daejeon 305701, South Korea
3 shared publicationsJin Kook Kim
3 shared publications
Latest Publications
- 6 October 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 128,p. e55815
Experimental Implementation of a New Composite Fabrication Method: Exposing Bare Fibers on the Composite Surface by the Soft Layer Method
The bipolar plate is a key component in proton exchange membrane fuel cells (PEMFCs) and vanadium redox flow batteries (VRFBs). It is a multi-functional component that should have high electrical conductivity, high mechanical properties, and high productivity. In this regard, a carbon fiber/epoxy resin composite can be an ideal material to replace the conventional graphite bipolar plate, which often leads to the catastrophic failure of the entire system because of its inherent brittleness. Though the carbon/epoxy composite has high mechanical properties and is easy to manufacture, the electrical conductivity in the through-thickness direction is poor because of the resin-rich layer that forms on its surface. Therefore, an expanded graphite coating was adopted to solve the electrical conductivity issue. However, the expanded graphite coating not only increases the manufacturing costs but also has poor mechanical properties. In this study, a method to expose fibers on the composite surface is demonstrated. There are currently many methods that can expose fibers by surface treatment after the fabrication of the composite. This new method, however, does not require surface treatment because the fibers are exposed during the manufacture of the composite. By exposing bare carbon fibers on the surface, the electrical conductivity and mechanical strength of the composite are increased drastically.
- 6 October 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 128,p. e55815
Experimental Implementation of a New Composite Fabrication Method: Exposing Bare Fibers on the Composite Surface by the Soft Layer Method
The bipolar plate is a key component in proton exchange membrane fuel cells (PEMFCs) and vanadium redox flow batteries (VRFBs). It is a multi-functional component that should have high electrical conductivity, high mechanical properties, and high productivity. In this regard, a carbon fiber/epoxy resin composite can be an ideal material to replace the conventional graphite bipolar plate, which often leads to the catastrophic failure of the entire system because of its inherent brittleness. Though the carbon/epoxy composite has high mechanical properties and is easy to manufacture, the electrical conductivity in the through-thickness direction is poor because of the resin-rich layer that forms on its surface. Therefore, an expanded graphite coating was adopted to solve the electrical conductivity issue. However, the expanded graphite coating not only increases the manufacturing costs but also has poor mechanical properties. In this study, a method to expose fibers on the composite surface is demonstrated. There are currently many methods that can expose fibers by surface treatment after the fabrication of the composite. This new method, however, does not require surface treatment because the fibers are exposed during the manufacture of the composite. By exposing bare carbon fibers on the surface, the electrical conductivity and mechanical strength of the composite are increased drastically.
- 1 August 2013
- Published by Scrivener Publishing in Reviews of Adhesion and Adhesives
- Vol. 1 (3) , 291-311
Cryogenic Performance of Adhesively Bonded Joints Composed of Thin Metal Adherends
Thin metals for cryogenic containment systems (CCS) are generally joined using adhesives due to the benefit of stress distribution over larger area and sealing effect. This article reviews the existing literature related to the adhesively bonded joints composed of thin metal adherends at the cryogenic temperature. At the cryogenic temperature, polymeric adhesives become very brittle although they are ductile at the room temperature, while the properties of metals for the cryogenic purpose, such as austenitic stainless steel or aluminum, change only little because they have face cubic lattice structure or hexagonal close-packed lattice structure without nil ductility temperature which is the temperature of material behavior from ductile to brittle. Previous researches on the adhesive joints at cryogenic temperatures have focused on improving the adhesion characteristics of adhesives through surface treatments of metal adherends and the reinforcement of adhesives to improve their fracture toughness. The surface treatments such as chemical, energetic and mechanical treatments, and the reinforcement of adhesives with fibers such as polyester, glass fiber and aramid fibers are indispensable for the reliability of the adhesive joints at cryogenic temperatures. Also, ageing effects after the surface treatment of metal adherends was clarified to apply the adhesively bonded metal joints to the actual CCS.
- 1 August 2013
- Published by Scrivener Publishing in Reviews of Adhesion and Adhesives
- Vol. 1 (3) , 291-311
Cryogenic Performance of Adhesively Bonded Joints Composed of Thin Metal Adherends
Thin metals for cryogenic containment systems (CCS) are generally joined using adhesives due to the benefit of stress distribution over larger area and sealing effect. This article reviews the existing literature related to the adhesively bonded joints composed of thin metal adherends at the cryogenic temperature. At the cryogenic temperature, polymeric adhesives become very brittle although they are ductile at the room temperature, while the properties of metals for the cryogenic purpose, such as austenitic stainless steel or aluminum, change only little because they have face cubic lattice structure or hexagonal close-packed lattice structure without nil ductility temperature which is the temperature of material behavior from ductile to brittle. Previous researches on the adhesive joints at cryogenic temperatures have focused on improving the adhesion characteristics of adhesives through surface treatments of metal adherends and the reinforcement of adhesives to improve their fracture toughness. The surface treatments such as chemical, energetic and mechanical treatments, and the reinforcement of adhesives with fibers such as polyester, glass fiber and aramid fibers are indispensable for the reliability of the adhesive joints at cryogenic temperatures. Also, ageing effects after the surface treatment of metal adherends was clarified to apply the adhesively bonded metal joints to the actual CCS.
- 1 April 2013
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 27 (7) , 794-810
Contact angle and wettability of hybrid surface-treated metal adherends
Adhesion performance of adhesively bonded metal joints with aluminum and stainless steel was much dependent on the surface treatment of the adherends. This work was aimed at optimizing hybrid surface treatments to improve wettability of metal surfaces and strength of adhesive metal joints, which was a combination of mechanical, chemical, and energetic surface treatment methods. The surface free energies and wettability of hybrid surface-treated metal adherends were measured for different treatment conditions with abrasion, grit blast, sulfuric acid etching, phosphoric acid anodizing, silane treatment, plasma treatment, and flame treatment. The surface morphology and chemical composition of the metal adherends were investigated by scanning electron microscopy and X-ray photoelectron spectroscopy and the bond strengths of the single-lap joints composed of aluminum and stainless steel adherends were measured with respect to hybrid surface treatment conditions. From the experiments, an effective hybrid surface treatment condition was suggested for metal surfaces with super-hydrophilic characteristics. Also, the failure mode of adhesive metal joints was evaluated by photo-surface analysis method.
- 1 April 2013
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 27 (7) , 794-810
Contact angle and wettability of hybrid surface-treated metal adherends
Adhesion performance of adhesively bonded metal joints with aluminum and stainless steel was much dependent on the surface treatment of the adherends. This work was aimed at optimizing hybrid surface treatments to improve wettability of metal surfaces and strength of adhesive metal joints, which was a combination of mechanical, chemical, and energetic surface treatment methods. The surface free energies and wettability of hybrid surface-treated metal adherends were measured for different treatment conditions with abrasion, grit blast, sulfuric acid etching, phosphoric acid anodizing, silane treatment, plasma treatment, and flame treatment. The surface morphology and chemical composition of the metal adherends were investigated by scanning electron microscopy and X-ray photoelectron spectroscopy and the bond strengths of the single-lap joints composed of aluminum and stainless steel adherends were measured with respect to hybrid surface treatment conditions. From the experiments, an effective hybrid surface treatment condition was suggested for metal surfaces with super-hydrophilic characteristics. Also, the failure mode of adhesive metal joints was evaluated by photo-surface analysis method.
- 1 February 2013
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 27 (3) , 278-293
Bonding characteristics and corrosion resistance of silane–cerium-treated aluminum adherend
A silane–cerium treatment was applied on an aluminum adherend to simultaneously improve the bonding performance and corrosion resistance of the adhesively bonded aluminum joint in cryogenic applications, such as with liquefied natural gas containment tanks. The lap shear strengths and corrosion performances of the adhesively bonded joints composed of treated aluminum adherends were measured with respect to the silane–cerium treatment and the surface pretreatment on the aluminum adherend. The bonding characteristics of the aluminum adherend were investigated by measuring the water contact angle and conducting the potentiodynamic polarization test after the aluminum adherends with different surface treatments of silane–cerium were immersed in a 0.5 M NaCl solution. In addition, the surfaces were analyzed with scanning electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy to characterize the chemical compositions of the silane–cerium-treated aluminum adherend. The experimental results show that an appropriate silane–cerium treatment on the aluminum adherend produces an effective corrosion-resistant layer and that it has a highly reliable bonding characteristic for the adhesive joint at a cryogenic temperature of −150 °C.
- 1 February 2013
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 27 (3) , 278-293
Bonding characteristics and corrosion resistance of silane–cerium-treated aluminum adherend
A silane–cerium treatment was applied on an aluminum adherend to simultaneously improve the bonding performance and corrosion resistance of the adhesively bonded aluminum joint in cryogenic applications, such as with liquefied natural gas containment tanks. The lap shear strengths and corrosion performances of the adhesively bonded joints composed of treated aluminum adherends were measured with respect to the silane–cerium treatment and the surface pretreatment on the aluminum adherend. The bonding characteristics of the aluminum adherend were investigated by measuring the water contact angle and conducting the potentiodynamic polarization test after the aluminum adherends with different surface treatments of silane–cerium were immersed in a 0.5 M NaCl solution. In addition, the surfaces were analyzed with scanning electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy to characterize the chemical compositions of the silane–cerium-treated aluminum adherend. The experimental results show that an appropriate silane–cerium treatment on the aluminum adherend produces an effective corrosion-resistant layer and that it has a highly reliable bonding characteristic for the adhesive joint at a cryogenic temperature of −150 °C.
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 1003-1016
Improvement of Fracture Toughness of Stainless Steel Adhesive Joints at Cryogenic Temperature
Film-type epoxy adhesive was reinforced with E-glass and polyester fiber mats to improve the fracture toughness of adhesive joints composed of austenite stainless steel adherends at the cryogenic t...
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 1003-1016
Improvement of Fracture Toughness of Stainless Steel Adhesive Joints at Cryogenic Temperature
Film-type epoxy adhesive was reinforced with E-glass and polyester fiber mats to improve the fracture toughness of adhesive joints composed of austenite stainless steel adherends at the cryogenic t...
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 969-986
Cryogenic Performance of Adhesively Bonded Metal Joints for LNG Containment System
The cryogenic performance of adhesively bonded joints composed of aluminum sandwich structures and stainless steel foils for LNG (Liquefied Natural Gas) containment system was studied. Surface trea...
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 969-986
Cryogenic Performance of Adhesively Bonded Metal Joints for LNG Containment System
The cryogenic performance of adhesively bonded joints composed of aluminum sandwich structures and stainless steel foils for LNG (Liquefied Natural Gas) containment system was studied. Surface trea...
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 987-1001
Fracture Toughness Measurement of Adhesively Bonded Joints at Cryogenic Temperatures
A sharp initial crack tip is required for measuring the fracture toughness or energy release rate of adhesive joints, especially at cryogenic temperatures because a blunt initial crack tip in the a...
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 987-1001
Fracture Toughness Measurement of Adhesively Bonded Joints at Cryogenic Temperatures
A sharp initial crack tip is required for measuring the fracture toughness or energy release rate of adhesive joints, especially at cryogenic temperatures because a blunt initial crack tip in the a...
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 885-887
Guest Editorial
- 1 April 2012
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 26 (7) , 885-887
Guest Editorial
- 14 April 2010
- Published by IOP Publishing in Nanotechnology
- Vol. 21 (18) , 185305
Nanometer-scale surface modification of epoxy with carbon black and electromagnetic waves
The surface morphology of polymers and polymer composites strongly influences both the adhesive bonding strength of composite structures and the electrical conduction through carbon fiber composites. Conventional surface modification techniques (such as mechanical abrading, chemical treatment, plasma treatment and flame treatment) not only damage the surfaces of polymers and polymer composites but also increase production cost. In this study, the surface of epoxy was modified by heating carbon black with electromagnetic waves in order to generate nanometer-sized grooves. A thermal transfer model was developed to investigate the generation mechanism of the grooves and the process variables. In the surface modification technique, electromagnetic waves and carbon black were used to improve both the bonding strength and the electrical conductivity of the composite in a fast and efficient way.
- 14 April 2010
- Published by IOP Publishing in Nanotechnology
- Vol. 21 (18) , 185305
Nanometer-scale surface modification of epoxy with carbon black and electromagnetic waves
The surface morphology of polymers and polymer composites strongly influences both the adhesive bonding strength of composite structures and the electrical conduction through carbon fiber composites. Conventional surface modification techniques (such as mechanical abrading, chemical treatment, plasma treatment and flame treatment) not only damage the surfaces of polymers and polymer composites but also increase production cost. In this study, the surface of epoxy was modified by heating carbon black with electromagnetic waves in order to generate nanometer-sized grooves. A thermal transfer model was developed to investigate the generation mechanism of the grooves and the process variables. In the surface modification technique, electromagnetic waves and carbon black were used to improve both the bonding strength and the electrical conductivity of the composite in a fast and efficient way.
- 1 January 2010
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 24 (4) , 775-787
Optimum Silane Treatment for the Adhesively Bonded Aluminum Adherends at the Cryogenic Temperature
Aluminum adherends for the adhesive joints at cryogenic application such as LNG (Liquefied Natural Gas) containment tanks were silane treated to improve bond strength of the aluminum joints. The bo...
- 1 January 2010
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 24 (4) , 775-787
Optimum Silane Treatment for the Adhesively Bonded Aluminum Adherends at the Cryogenic Temperature
Aluminum adherends for the adhesive joints at cryogenic application such as LNG (Liquefied Natural Gas) containment tanks were silane treated to improve bond strength of the aluminum joints. The bo...