P. Anninos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
P. Anninos has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Athanasia Kotini
Medical Physics Laboratory, School of Medicine, Democritus University of Thrace, 69100 Alexandroupolis, Greece
13 shared publications P Anastasiadis
6 shared publicationsD Tamiolakis
5 shared publicationsA. Adamopoulos
4 shared publicationsN Koutlaki
4 shared publicationsA Adamopoulos
3 shared publications
Latest Publications
- 10 June 2016
- Published by IMR Press in Clinical and Experimental Obstetrics & Gynecology
- Vol. 43 (3) , 406-408
Biomagnetic activity and non linear analysis in obstetrics and gynecology in a Greek population
This article reports the application of non-linear analysis to biomagnetic signals recorded from fetal growth restriction, fetal brain activity, ovarian lesions, breast lesions, umbilical arteries, uterine myomas, and uterine arteries in a Greek population. The results were correlated with clinical findings. The biomagnetic measurements and the application of non-linear analysis are promising procedures in Obstetrics and Gynecology.
- 10 June 2016
- Published by IMR Press in Clinical and Experimental Obstetrics & Gynecology
- Vol. 43 (3) , 406-408
Biomagnetic activity and non linear analysis in obstetrics and gynecology in a Greek population
This article reports the application of non-linear analysis to biomagnetic signals recorded from fetal growth restriction, fetal brain activity, ovarian lesions, breast lesions, umbilical arteries, uterine myomas, and uterine arteries in a Greek population. The results were correlated with clinical findings. The biomagnetic measurements and the application of non-linear analysis are promising procedures in Obstetrics and Gynecology.
- Open Access
- 1 April 2008
- Published by Archivos Espanoles de Urologia in Archivos Espanoles de Urologia
- Vol. 61 (3) , 459-463
Biomagnetic activity in prostate cancer and BPH
The aim of this study was to investigate the role of biomagnetic activity measurements in detecting prostate malignancies, in differentiating cancerous from benign prostate lesions and in generally improving our understanding of prostate cancer biology. Magnetic recordings were obtained from 47 patients with palpable prostate lesions. Twenty-four had prostate carcinoma and 23 benign prostatic hyperplasia (BPH). The magnetic field recorded in the 2-7 Hz frequency range was of high amplitude in most (95%) malignant lesions 248 +/- 82 Ft/Hz) and of low amplitude in most (95%) benign ones (166 +/-31 Ft/Hz). These findings displayed significant difference (p = 0.0021). Prostate cancer emits higher biomagnetic activity than BPH. This finding confirms the higher angiogenic activity of prostate cancer. The use of this method is safe and seems promising.
- 1 April 2008
- Published by Archivos Espanoles de Urologia in Archivos Espanoles de Urologia
- Vol. 61 (3) , 459-463
Open AccessBiomagnetic activity in prostate cancer and BPH
The aim of this study was to investigate the role of biomagnetic activity measurements in detecting prostate malignancies, in differentiating cancerous from benign prostate lesions and in generally improving our understanding of prostate cancer biology. Magnetic recordings were obtained from 47 patients with palpable prostate lesions. Twenty-four had prostate carcinoma and 23 benign prostatic hyperplasia (BPH). The magnetic field recorded in the 2-7 Hz frequency range was of high amplitude in most (95%) malignant lesions 248 +/- 82 Ft/Hz) and of low amplitude in most (95%) benign ones (166 +/-31 Ft/Hz). These findings displayed significant difference (p = 0.0021). Prostate cancer emits higher biomagnetic activity than BPH. This finding confirms the higher angiogenic activity of prostate cancer. The use of this method is safe and seems promising.
- 1 March 2008
- Published by World Scientific Pub Co Pte Ltd in Journal of Integrative Neuroscience
- Vol. 07 (01) , 17-27
MEG RECORDINGS OF PATIENTS WITH CNS DISORDERS BEFORE AND AFTER EXTERNAL MAGNETIC STIMULATION
Magnetoencephalographic (MEG) recordings of patients with CNS disorders were obtained using a whole-head 122-channel magnetometer SQUID and analyzed using Fourier statistical analysis. External transcranial magnetic stimulation in the order of pico Tesla (pTMS) was applied to the above patients with proper characteristics (magnetic intensity 1–7.5 pT; frequency: 8–13 Hz) which were obtained with MEG recordings prior to pTMS. The MEG recordings after the application of pTMS showed a rapid attenuation of the high abnormal activity followed by an increase in the number of the low frequency components toward the patients α-rhythm. The possible mechanisms of the effects of external magnetic stimulation on the pineal gland in the brain are presented.
- 1 March 2008
- Published by World Scientific Pub Co Pte Ltd in Journal of Integrative Neuroscience
- Vol. 07 (01) , 17-27
MEG RECORDINGS OF PATIENTS WITH CNS DISORDERS BEFORE AND AFTER EXTERNAL MAGNETIC STIMULATION
Magnetoencephalographic (MEG) recordings of patients with CNS disorders were obtained using a whole-head 122-channel magnetometer SQUID and analyzed using Fourier statistical analysis. External transcranial magnetic stimulation in the order of pico Tesla (pTMS) was applied to the above patients with proper characteristics (magnetic intensity 1–7.5 pT; frequency: 8–13 Hz) which were obtained with MEG recordings prior to pTMS. The MEG recordings after the application of pTMS showed a rapid attenuation of the high abnormal activity followed by an increase in the number of the low frequency components toward the patients α-rhythm. The possible mechanisms of the effects of external magnetic stimulation on the pineal gland in the brain are presented.
- 25 March 2007
- Vol. 43 (3) , 345-8
MEG mapping in multiple sclerosis patients.
The research over the past decade suggests that multiple sclerosis (MS) is a disease due to disorders of the immune system. Since the immune system is regulated by the pineal gland, which exerts immunomodulatory action with the secretion of melatonin and profound effects on electrical activity in the hippocampus, cerebellum and reticular formation structures, we have used magnetoencephalogram (MEG) recordings from MS patients in order to find any differentiation in brain activity in comparison with controls. Ten MS patients and 10 controls were included in this study. The measurements were performed with a superconducting quantum interference device (SQUID) in an electrically shielded room. For each patient the magnetic activity was recorded from a total of 32 points of the skull as defined by a recording reference system, which is based on the International 10-20 Electrode Placement System. The biomagnetic signals (waveforms) were expressed in terms of magnetic power spectral amplitudes in the frequency range of 2-7 Hz. Some of the recorded points were observed to exhibit abnormal rhythmic activity, characterized by lower amplitudes and frequencies compared with controls. Using the MEG brain activity we were able to obtain a mapping technique characterized by the ISO-spectral amplitude of scalp distribution. This study, although preliminary, presents a novel approach for measuring brain biomagnetic activity from MS patients.
- 25 March 2007
- Vol. 43 (3) , 345-8
MEG mapping in multiple sclerosis patients.
The research over the past decade suggests that multiple sclerosis (MS) is a disease due to disorders of the immune system. Since the immune system is regulated by the pineal gland, which exerts immunomodulatory action with the secretion of melatonin and profound effects on electrical activity in the hippocampus, cerebellum and reticular formation structures, we have used magnetoencephalogram (MEG) recordings from MS patients in order to find any differentiation in brain activity in comparison with controls. Ten MS patients and 10 controls were included in this study. The measurements were performed with a superconducting quantum interference device (SQUID) in an electrically shielded room. For each patient the magnetic activity was recorded from a total of 32 points of the skull as defined by a recording reference system, which is based on the International 10-20 Electrode Placement System. The biomagnetic signals (waveforms) were expressed in terms of magnetic power spectral amplitudes in the frequency range of 2-7 Hz. Some of the recorded points were observed to exhibit abnormal rhythmic activity, characterized by lower amplitudes and frequencies compared with controls. Using the MEG brain activity we were able to obtain a mapping technique characterized by the ISO-spectral amplitude of scalp distribution. This study, although preliminary, presents a novel approach for measuring brain biomagnetic activity from MS patients.
- 1 March 2007
- Vol. 107 (1) , 5-10
MEG evaluation of Parkinson's diseased patients after external magnetic stimulation.
Magnetoencephalographic (MEG) recordings of Parkinson's diseased (PD) patients were obtained using a whole-head 122-channel magnetometer and analyzed with Fourier statistical analysis. External transcranial magnetic stimulation (TMS) in the order of pico Tesla was applied on the above patients with proper field characteristics (magnetic amplitude : 1-7.5 pT, frequency : the alpha-rhythm of the patient: 8-13 Hz) which were obtained prior to TMS. The MEG recordings after the application of TMS showed a rapid attenuation of the high abnormal activity followed by an increase of the low frequency components toward the patients' alpha-rhythm. The patients responded to the TMS with a feeling of relaxation and partial or complete disappearance of tremor, muscular ache and levodopa induced dyskinesias as well as rapid reversed visuospatial impairment, which were followed by a corresponding improvement and normalization of the MEG.
- 1 March 2007
- Vol. 107 (1) , 5-10
MEG evaluation of Parkinson's diseased patients after external magnetic stimulation.
Magnetoencephalographic (MEG) recordings of Parkinson's diseased (PD) patients were obtained using a whole-head 122-channel magnetometer and analyzed with Fourier statistical analysis. External transcranial magnetic stimulation (TMS) in the order of pico Tesla was applied on the above patients with proper field characteristics (magnetic amplitude : 1-7.5 pT, frequency : the alpha-rhythm of the patient: 8-13 Hz) which were obtained prior to TMS. The MEG recordings after the application of TMS showed a rapid attenuation of the high abnormal activity followed by an increase of the low frequency components toward the patients' alpha-rhythm. The patients responded to the TMS with a feeling of relaxation and partial or complete disappearance of tremor, muscular ache and levodopa induced dyskinesias as well as rapid reversed visuospatial impairment, which were followed by a corresponding improvement and normalization of the MEG.
- 1 January 2007
- Vol. 34 (1) , 42-6
Biomagnetism in perinatal medicine. Our experience in Greece.
This is a report on our experience in the application of biomagnetism in perinatal medicine. We provide a brief description of our research work in fetal magnetoencephalography and fetal magnetocardiography in normal, preeclamptic and IUGR pregnancies, together with hemodynamics of the umbilical cord and uterine arteries, providing a new approach to biomagnetism as a non invasive imaging modality in the investigation of perinatal complications.
- 1 January 2007
- Vol. 34 (1) , 42-6
Biomagnetism in perinatal medicine. Our experience in Greece.
This is a report on our experience in the application of biomagnetism in perinatal medicine. We provide a brief description of our research work in fetal magnetoencephalography and fetal magnetocardiography in normal, preeclamptic and IUGR pregnancies, together with hemodynamics of the umbilical cord and uterine arteries, providing a new approach to biomagnetism as a non invasive imaging modality in the investigation of perinatal complications.
- 1 December 2006
- Published by World Scientific Pub Co Pte Ltd in Journal of Integrative Neuroscience
- Vol. 05 (04) , 535-540
IDENTIFICATION OF TASTE QUALITY WITH THE USE OF MEG
We investigated the localization of current sources for spontaneous magnetoencephalographic (MEG) data in the frequency domain. MEGs were evaluated in three different states: (i) physiological condition; (ii) sweet taste, and (iii) salt taste. Low frequencies can be seen in the maps obtained with the sweet taste, whereas in the physiological and salt taste, the maps show higher frequencies in the majority of channels. A differentiation in the spatial distribution of the frequencies provides novel insights into the identification of taste quality with the MEG systems.
- 1 December 2006
- Published by World Scientific Pub Co Pte Ltd in Journal of Integrative Neuroscience
- Vol. 05 (04) , 535-540
IDENTIFICATION OF TASTE QUALITY WITH THE USE OF MEG
We investigated the localization of current sources for spontaneous magnetoencephalographic (MEG) data in the frequency domain. MEGs were evaluated in three different states: (i) physiological condition; (ii) sweet taste, and (iii) salt taste. Low frequencies can be seen in the maps obtained with the sweet taste, whereas in the physiological and salt taste, the maps show higher frequencies in the majority of channels. A differentiation in the spatial distribution of the frequencies provides novel insights into the identification of taste quality with the MEG systems.
- 1 January 2006
- Vol. 33 (4) , 229-32
Magnetoencephalography and magnetocardiography in neonates. Our experience in Greece.
This study reports our experience in the application of magnetoencephalography (MEG) and magnetocardiography (MCG) in neonates. Results gained from our studies, lead us to believe that MEG and MCG could provide clinical practice with non-invasive, rapid and easy to perform methods, which could be adjuncts to conventional methods for the evaluation of neonatal brain and heart function.
- 1 January 2006
- Vol. 33 (4) , 229-32
Magnetoencephalography and magnetocardiography in neonates. Our experience in Greece.
This study reports our experience in the application of magnetoencephalography (MEG) and magnetocardiography (MCG) in neonates. Results gained from our studies, lead us to believe that MEG and MCG could provide clinical practice with non-invasive, rapid and easy to perform methods, which could be adjuncts to conventional methods for the evaluation of neonatal brain and heart function.
- 1 January 2006
- Vol. 27 (6) , 594-6
Biomagnetism in gynaecologic oncology. Our experience in Greece.
Our experience in the application of biomagnetism in gynaecologic oncology is presented. We provide a brief description of our research work in the investigation of biomagnetic activity in benign and malignant ovarian and breast diseases, and an evaluation of uterine myomas, providing a new approach of biomagnetism as a non invasive imaging modality for assessing gynaecologic tumours.
- 1 January 2006
- Vol. 27 (6) , 594-6
Biomagnetism in gynaecologic oncology. Our experience in Greece.
Our experience in the application of biomagnetism in gynaecologic oncology is presented. We provide a brief description of our research work in the investigation of biomagnetic activity in benign and malignant ovarian and breast diseases, and an evaluation of uterine myomas, providing a new approach of biomagnetism as a non invasive imaging modality for assessing gynaecologic tumours.
- Open Access
- 29 August 2003
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 22 (S1) , 120
P186: Biomagnetic and Doppler findings of umbilical artery in fetal growth restriction
- 29 August 2003
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 22 (S1) , 120
Open AccessP186: Biomagnetic and Doppler findings of umbilical artery in fetal growth restriction