PSPhilip W. Scruggs

Philip W. Scruggs

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Philip W. Scruggs has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Brian D. Clocksin

    Department of Exercise and Sport Science , The University of Utah

    1 shared publication
  • Doris L. Watson

    Department of Exercise and Sport Science , The University of Utah

    1 shared publication
  • Sandy K. Beveridge

    Department of Exercise and Sport Science , The University of Utah

    1 shared publication

Latest Publications

  • A Comparative Analysis of Pedometry in Measuring Physical Activity of Children

    by Philip W. Scruggs

    The purpose of this study was to examine the step and physical activity time output features of the Walk4Life LS2505 pedometer under field physical activity conditions. Data were collected on 288 (12.62 +/- 1.23 yr) participants during a school-based structured physical activity program. Participants' physical activity levels were concurrently measured via the Yamax SW701 (Yamax Corp., Japan) and Walk4Life LS2505 (Walk4Life Inc., Plainfield, IL) pedometers, and System for Observing Fitness Instruction Time (SOFIT) physical activity coding mechanism. Relative and absolute agreement between SW701 (criterion) and LS2505 steps per minute, and SOFIT (criterion) and LS2505 physical activity time (min) were analyzed overall, and across physical activity content themes and physical activity quartiles. Physical activity measure correlations were moderately strong to strong (r = 0.85-0.98, P < 0.05); however, the LS2505 significantly underestimated steps per minute (M(diff) = 6.37 +/- 5.79, P < 0.05) and overestimated physical activity time (M(diff) = -7.73 +/- 3.13, P < 0.05). When LS2505 steps per minute were examined across physical activity themes and quartiles, clinically acceptable absolute error scores (<or= 10 +/- 5%) were found when physical activity was mostly continuous, or intermittent and moderate to high. The LS2505 physical activity time measure was clinically acceptable only when physical activity was continuous. It is recommended that the LS2505 pedometer output of time only be employed when physical activity is continuous, or when physical activity is continuous, or intermittent and moderate to high for the output of steps.


  • Middle School Physical Education Physical Activity Quantification

    by Philip W. Scruggs

    The objective of the study was to improve physical activity (PA) surveillance of the Healthy People 2010 Objective 22:10 (i.e., 50% of the lesson time engaged in PA) by establishing a pedometer steps/min guideline to quantify time engaged in PA during physical education. A sample of 180 middle school students had their PA measured via pedometry (steps/min) and behavioral observation (PA time). Factorial analyses of variance were used to examine PA differences. Linear and logistic regression, decision accuracy, and receiver-operating-characteristic (ROC) statistics were used to test steps/min cut points against the 50% PA recommendation. PA differences were not found (p > .01). Steps/min was a significant (p ≤ .01) predictor of PA time, and the binary outcome of meeting or not meeting the PA recommendation. A steps/min interval of 82–88 was an accurate indicator of the 50% PA recommendation. The ROC statistic was .97 (p ≤ .01), suggesting steps/min was an excellent discriminator of the binary outcome. Pedometer steps/min is a valid, objective, and practical approach for surveillance of physical education PA, a key physical education and public health outcome.


  • Quantifying Physical Activity in First- Through Fourth- Grade Physical Education via Pedometry

    by Philip W. Scruggs, Sandy K. Beveridge, Doris L. Watson, Brian D. Clocksin

    The aim of this study was to determine pedometry steps per minute (SPM) cutscores that accurately quantify physical activity (PA) time in first-through fourth-grade physical education. A total of 257 participants were grouped in two data pools, first-and second-grade (n = 126), and third- and fourth-grade (n = 131). Systematic observation was the PA criterion instrument and pedometry was the predictor instrument. Correlations between physical activity measures were strong (r = 82–89, p < .01). Ten min of PA and 33.33% of the lesson time engaged in PA within a 30-min class can be quantified by 61–63 SPM for first- and second-grade, and 58–61 SPM for third- and fourth-grade. In conclusion: (a) SPM values were a valid indicator of students achieving or not achieving PA criteria, and (b) pedometry is a valid and practical tool for physical activity surveillance within physical education.