Chanwoo Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chanwoo Park has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Aparna Vallury
IBM, Research Triangle Park, NC 27709
1 shared publicationBatikan Köroğlu
1 shared publicationEvan Le
Department of Mechanical Engineering, University of Nevada, Reno, NV 89557-0312
1 shared publicationJon Zuo
Advanced Cooling Technologies, Inc., Lancaster, PA 17601
1 shared publicationMassoud Kaviany
Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48105, USA
1 shared publicationNicholas Bogan
1 shared publication
Latest Publications
- 29 May 2013
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 64, 680-688
Superadiabatic radiant porous burner with preheater and radiation corridors
- 29 May 2013
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 64, 680-688
Superadiabatic radiant porous burner with preheater and radiation corridors
- 20 March 2013
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (4) , 041802
Effects of Tube Row on Heat Transfer and Surface Wetting of Microscale Porous-Layer Coated, Horizontal-Tube, Falling-Film Evaporator
An experimental study was conducted to investigate the effects of tube row on surface wetting and heat transfer of a horizontal-tube, falling-film evaporator. Two types of the evaporator tubes were used for comparison: plain copper and copper coated with a microscale porous-layer. Distilled water was used as solution and heating fluids. A visual observation experiment performed in ambient with no heat input showed that when solution fluid was dripped onto the evaporator tubes from a solution dispenser, the plain tubes were partially wetted, while the porous-layer coated tubes were completely wetted due to capillary liquid spreading, even at low solution flow rates. It was found from the heat transfer experiment performed in a closed chamber under saturated conditions that the porous-layer coated tubes exhibited superior evaporation heat transfer (up to 100% overall improvement over the plain tubes at low solution flow rates) due to complete solution wetting and thin-film evaporation. It was also observed that the surface wetting and heat transfer are greatly influenced by both intertube flow mode of solution fluid and tube wall superheat. The effects of the tube row on the solution wetting and heat transfer were significant, especially for downstream tubes.
- 20 March 2013
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (4) , 041802
Effects of Tube Row on Heat Transfer and Surface Wetting of Microscale Porous-Layer Coated, Horizontal-Tube, Falling-Film Evaporator
An experimental study was conducted to investigate the effects of tube row on surface wetting and heat transfer of a horizontal-tube, falling-film evaporator. Two types of the evaporator tubes were used for comparison: plain copper and copper coated with a microscale porous-layer. Distilled water was used as solution and heating fluids. A visual observation experiment performed in ambient with no heat input showed that when solution fluid was dripped onto the evaporator tubes from a solution dispenser, the plain tubes were partially wetted, while the porous-layer coated tubes were completely wetted due to capillary liquid spreading, even at low solution flow rates. It was found from the heat transfer experiment performed in a closed chamber under saturated conditions that the porous-layer coated tubes exhibited superior evaporation heat transfer (up to 100% overall improvement over the plain tubes at low solution flow rates) due to complete solution wetting and thin-film evaporation. It was also observed that the surface wetting and heat transfer are greatly influenced by both intertube flow mode of solution fluid and tube wall superheat. The effects of the tube row on the solution wetting and heat transfer were significant, especially for downstream tubes.
- 23 December 2011
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 134 (1) , 011801
Investigation of the Effect of Growth From Low to High Biomass Concentration Inside a Photobioreactor on Hydrodynamic Properties of Scenedesmus obliquus
Most of the current production cost in algae biodiesel plants utilizing photobioreactors comes from the high energy required for pumping, CO2 transfer, mixing, and harvesting. Since pumping affects the mixing and CO2 transfer, which are the main factors in algae productivities, solutions to reduce the required energy for pumps can significantly make algae biodiesel production more economically feasible. An investigation on the effect of Scenedesmus obliquus’s growth from low to high biomass concentration inside a horizontal tubular photobioreactor to determine the impact that it has on hydrodynamic performances, which will affect cost and production efficiency, was performed. As the biomass concentration increased, the algal culture was found to remain Newtonian. Additionally, the biomass concentration (expressed in cell density) was found to have lower viscosity even at the highest concentrations evaluated at 2.48 × 108 cell/ml (1.372 × 10−3 ± 1.32 × 10−4 Pa s) compared to the Modified Bold’s 3N medium (1.408 × 10−3 ± 9.41 × 10−5 Pa s). Furthermore, the total energy consumption does not appear to depend on the S. obliquus biomass concentrations, but rather on the medium the algae grows in. The rheological properties of autotrophic algae will not have significant impact on energy requirements until technology improves so that the concentrations reach those of heterotrophic algae.
- 23 December 2011
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 134 (1) , 011801
Investigation of the Effect of Growth From Low to High Biomass Concentration Inside a Photobioreactor on Hydrodynamic Properties of Scenedesmus obliquus
Most of the current production cost in algae biodiesel plants utilizing photobioreactors comes from the high energy required for pumping, CO2 transfer, mixing, and harvesting. Since pumping affects the mixing and CO2 transfer, which are the main factors in algae productivities, solutions to reduce the required energy for pumps can significantly make algae biodiesel production more economically feasible. An investigation on the effect of Scenedesmus obliquus’s growth from low to high biomass concentration inside a horizontal tubular photobioreactor to determine the impact that it has on hydrodynamic performances, which will affect cost and production efficiency, was performed. As the biomass concentration increased, the algal culture was found to remain Newtonian. Additionally, the biomass concentration (expressed in cell density) was found to have lower viscosity even at the highest concentrations evaluated at 2.48 × 108 cell/ml (1.372 × 10−3 ± 1.32 × 10−4 Pa s) compared to the Modified Bold’s 3N medium (1.408 × 10−3 ± 9.41 × 10−5 Pa s). Furthermore, the total energy consumption does not appear to depend on the S. obliquus biomass concentrations, but rather on the medium the algae grows in. The rheological properties of autotrophic algae will not have significant impact on energy requirements until technology improves so that the concentrations reach those of heterotrophic algae.
- 1 June 2009
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 1 (2) , 022004
Performance Evaluation of a Pump-Assisted, Capillary Two-Phase Cooling Loop
A hybrid (pump-assisted and capillary) two-phase loop (HTPL) is experimentally investigated to characterize its thermal performance under stepwise heat input conditions. An integration of mechanical pumping with capillary pumping is achieved by using planar evaporator(s) and a two-loop design separating liquid and vapor flows. The evaporator(s) use a sintered copper grooved wick bonded with a liquid screen artery. No active flow control of the mechanical pumping is required because of the autonomous capillary pumping due to the self-adjusting liquid menisci to variable heat inputs of the evaporators. Unlike other active two-phase cooling systems using liquid spray and microchannels, the HTPL facilitates a passive phase separation of liquid from vapor in the evaporator using capillary action, which results in a lower flow resistance of the single-phase flows than two-phase mixed flows in fluid transport lines. In this work, a newly developed planar form-factor evaporator with a boiling heat transfer area of 135.3 cm2 is used aiming for the power electronics with large rectangular-shaped heat sources. This paper presents the experimental results of the HTPLs with a single evaporator handling a single heat source and dual evaporators handling two separate heat sources, while using distilled water as the working fluid for both cases. For the single evaporator system, the temperature results show that the HTPL does not create a big temperature upset under a stepwise heat load with sudden power increases and decreases. The evaporator thermal resistance is measured to be as low as 0.5 K cm2/W for the maximum heat load of 4.0 kW. A cold-start behavior characterized by a big temperature fluctuation was observed at the low heat inputs around 500 W. The HTPL with dual evaporators shows a strong interaction between the evaporators under an asymmetric heat load of the total maximum heat input of 6.5 kW, where each evaporator follows a different heat input schedule. The temperatures of the dual-evaporator system follow the profile of the total heat input, while the individual heat inputs determine the relative level of the temperatures of the evaporators.
- 1 June 2009
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 1 (2) , 022004
Performance Evaluation of a Pump-Assisted, Capillary Two-Phase Cooling Loop
A hybrid (pump-assisted and capillary) two-phase loop (HTPL) is experimentally investigated to characterize its thermal performance under stepwise heat input conditions. An integration of mechanical pumping with capillary pumping is achieved by using planar evaporator(s) and a two-loop design separating liquid and vapor flows. The evaporator(s) use a sintered copper grooved wick bonded with a liquid screen artery. No active flow control of the mechanical pumping is required because of the autonomous capillary pumping due to the self-adjusting liquid menisci to variable heat inputs of the evaporators. Unlike other active two-phase cooling systems using liquid spray and microchannels, the HTPL facilitates a passive phase separation of liquid from vapor in the evaporator using capillary action, which results in a lower flow resistance of the single-phase flows than two-phase mixed flows in fluid transport lines. In this work, a newly developed planar form-factor evaporator with a boiling heat transfer area of 135.3 cm2 is used aiming for the power electronics with large rectangular-shaped heat sources. This paper presents the experimental results of the HTPLs with a single evaporator handling a single heat source and dual evaporators handling two separate heat sources, while using distilled water as the working fluid for both cases. For the single evaporator system, the temperature results show that the HTPL does not create a big temperature upset under a stepwise heat load with sudden power increases and decreases. The evaporator thermal resistance is measured to be as low as 0.5 K cm2/W for the maximum heat load of 4.0 kW. A cold-start behavior characterized by a big temperature fluctuation was observed at the low heat inputs around 500 W. The HTPL with dual evaporators shows a strong interaction between the evaporators under an asymmetric heat load of the total maximum heat input of 6.5 kW, where each evaporator follows a different heat input schedule. The temperatures of the dual-evaporator system follow the profile of the total heat input, while the individual heat inputs determine the relative level of the temperatures of the evaporators.