Brian D. Hemond
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Brian D. Hemond has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrew James Taberner
Auckland Bioengineering Institute University of Auckland Auckland New Zealand
7 shared publications - Dawn M. Wendell
Doctoral candidate, Mechanical Engineering Department, Massachusetts Institute of Technology, Cambridge, MA 02139
6 shared publications - Ian W. Hunter
BioInstrumentation Laboratory, Massachusetts Institute of Technology, Cambridge, MA, USA
6 shared publications - N. Catherine Hogan
Research Associate, Bioinstrumentation Lab, Mechanical Engineering Department, Massachusetts Institute of Technology, Cambridge, MA02139
6 shared publications Bryan Crane
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
1 shared publicationCathy Hogan
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
1 shared publication
Latest Publications
- 3 February 2011
- Published by ASME International in Journal of Medical Devices
- Vol. 5 (1) , 015001
Development and Performance of a Controllable Autoloading Needle-Free Jet Injector
A jet injector platform technology that provides improved performance over existing jet injectors through the use of a controllable linear Lorentz-force actuator and software-based control system has been developed. Injectors designed on this platform are capable of delivering injections using arbitrary pressure pulse shaping. Pulse shaping has been shown to allow a wide degree of control over the depth to which the injection is delivered. A software-based injector control system improves repeatability and allows for automatic reloading of the injector, a task that would be difficult to implement using existing jet injector platforms. A design for a prototype autoloading controllable jet injector (cJI) based on this platform is detailed. The injection capability of this cJI was evaluated both in-vitro and in-vivo using a tissue analog, excised porcine tissue, and ovine tissue. An analysis of the cJI’s performance indicates that this design is capable of delivering a controllable volume of fluid to a controllable depth based entirely on the parameter’s input into the control software.
- 3 February 2011
- Published by ASME International in Journal of Medical Devices
- Vol. 5 (1) , 015001
Development and Performance of a Controllable Autoloading Needle-Free Jet Injector
A jet injector platform technology that provides improved performance over existing jet injectors through the use of a controllable linear Lorentz-force actuator and software-based control system has been developed. Injectors designed on this platform are capable of delivering injections using arbitrary pressure pulse shaping. Pulse shaping has been shown to allow a wide degree of control over the depth to which the injection is delivered. A software-based injector control system improves repeatability and allows for automatic reloading of the injector, a task that would be difficult to implement using existing jet injector platforms. A design for a prototype autoloading controllable jet injector (cJI) based on this platform is detailed. The injection capability of this cJI was evaluated both in-vitro and in-vivo using a tissue analog, excised porcine tissue, and ovine tissue. An analysis of the cJI’s performance indicates that this design is capable of delivering a controllable volume of fluid to a controllable depth based entirely on the parameter’s input into the control software.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 679-682
A Lorentz-Force Actuated Autoloading Needle-free Injector
The advantages of delivering injections via needle-free methods are numerous. However, conventional methods for needle-free injection lack sufficient control over depth of penetration and shape of injection. Thus, a needle-free injector was designed, constructed, and tested, using a controllable linear Lorentz-force actuator. This actuator allows rapid control of the injection pressure during injections. Using this device, precise control over delivery parameters can be achieved. The injector design was tested for repeatability and evaluated for depth control using acrylamide gel and dye
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 679-682
A Lorentz-Force Actuated Autoloading Needle-free Injector
The advantages of delivering injections via needle-free methods are numerous. However, conventional methods for needle-free injection lack sufficient control over depth of penetration and shape of injection. Thus, a needle-free injector was designed, constructed, and tested, using a controllable linear Lorentz-force actuator. This actuator allows rapid control of the injection pressure during injections. Using this device, precise control over delivery parameters can be achieved. The injector design was tested for repeatability and evaluated for depth control using acrylamide gel and dye
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 5005-5008
The Effect of Jet Parameters on Jet Injection
Current jet injection devices often utilize compressed air or springs to create a high-pressure fluid jet capable of piercing the skin. However, these devices are limited to a single invariable injection profile based on the impulse created by the compressed air or spring and therefore the parameters that affect injection are not well understood. To determine the effect of injection parameters on jet injection into tissue, including the effect of the fluid ejection profile on the injection, a controllable jet injection device was used to perform experiments into sheep and pig tissue. This paper demonstrates the importance of an initial peak in injection pressure and a subsequent lower follow-through pressure for successful jet injection into sheep and pig tissue
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 5005-5008
The Effect of Jet Parameters on Jet Injection
Current jet injection devices often utilize compressed air or springs to create a high-pressure fluid jet capable of piercing the skin. However, these devices are limited to a single invariable injection profile based on the impulse created by the compressed air or spring and therefore the parameters that affect injection are not well understood. To determine the effect of injection parameters on jet injection into tissue, including the effect of the fluid ejection profile on the injection, a controllable jet injection device was used to perform experiments into sheep and pig tissue. This paper demonstrates the importance of an initial peak in injection pressure and a subsequent lower follow-through pressure for successful jet injection into sheep and pig tissue
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5611-5616
Delivery of Active Collagenase to Skin Using a Lorentz-Force Actuated Needle-Free Injector
The development of new therapeutics and the desire to reduce the frequency of needle stick injuries, overcome the improper reuse of needles, improve compliance, and reduce the prohibitive cost of disposal have fueled resurgent efforts to develop alternative drug delivery methods. This report discusses the use of a controllable Lorentz-force actuated needle-free injector to deliver a blend of bacterial collagenases to the skin. Drug ejected/injected using a preprogrammed pressure vs time profile through a 100 or 200 mum orifice showed activity comparable to that observed following ejection/injection using a conventional syringe as determined by a solution based fluorescence assay and zymography. In a live animal trial, necrosis, hair loss, and minimal bruising were observed at drug injected sites regardless of the delivery mode as were changes in tissue morphology
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5611-5616
Delivery of Active Collagenase to Skin Using a Lorentz-Force Actuated Needle-Free Injector
The development of new therapeutics and the desire to reduce the frequency of needle stick injuries, overcome the improper reuse of needles, improve compliance, and reduce the prohibitive cost of disposal have fueled resurgent efforts to develop alternative drug delivery methods. This report discusses the use of a controllable Lorentz-force actuated needle-free injector to deliver a blend of bacterial collagenases to the skin. Drug ejected/injected using a preprogrammed pressure vs time profile through a 100 or 200 mum orifice showed activity comparable to that observed following ejection/injection using a conventional syringe as determined by a solution based fluorescence assay and zymography. In a live animal trial, necrosis, hair loss, and minimal bruising were observed at drug injected sites regardless of the delivery mode as were changes in tissue morphology
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5611-5616
Delivery of Active Collagenase to Skin Using a Lorentz-Force Actuated Needle-Free Injector
The development of new therapeutics and the desire to reduce the frequency of needle stick injuries, overcome the improper reuse of needles, improve compliance, and reduce the prohibitive cost of disposal have fueled resurgent efforts to develop alternative drug delivery methods. This report discusses the use of a controllable Lorentz-force actuated needle-free injector to deliver a blend of bacterial collagenases to the skin. Drug ejected/injected using a preprogrammed pressure vs time profile through a 100 or 200 mum orifice showed activity comparable to that observed following ejection/injection using a conventional syringe as determined by a solution based fluorescence assay and zymography. In a live animal trial, necrosis, hair loss, and minimal bruising were observed at drug injected sites regardless of the delivery mode as were changes in tissue morphology
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5611-5616
Delivery of Active Collagenase to Skin Using a Lorentz-Force Actuated Needle-Free Injector
The development of new therapeutics and the desire to reduce the frequency of needle stick injuries, overcome the improper reuse of needles, improve compliance, and reduce the prohibitive cost of disposal have fueled resurgent efforts to develop alternative drug delivery methods. This report discusses the use of a controllable Lorentz-force actuated needle-free injector to deliver a blend of bacterial collagenases to the skin. Drug ejected/injected using a preprogrammed pressure vs time profile through a 100 or 200 mum orifice showed activity comparable to that observed following ejection/injection using a conventional syringe as determined by a solution based fluorescence assay and zymography. In a live animal trial, necrosis, hair loss, and minimal bruising were observed at drug injected sites regardless of the delivery mode as were changes in tissue morphology
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5005-5008
The Effect of Jet Parameters on Jet Injection
Current jet injection devices often utilize compressed air or springs to create a high-pressure fluid jet capable of piercing the skin. However, these devices are limited to a single invariable injection profile based on the impulse created by the compressed air or spring and therefore the parameters that affect injection are not well understood. To determine the effect of injection parameters on jet injection into tissue, including the effect of the fluid ejection profile on the injection, a controllable jet injection device was used to perform experiments into sheep and pig tissue. This paper demonstrates the importance of an initial peak in injection pressure and a subsequent lower follow-through pressure for successful jet injection into sheep and pig tissue
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5005-5008
The Effect of Jet Parameters on Jet Injection
Current jet injection devices often utilize compressed air or springs to create a high-pressure fluid jet capable of piercing the skin. However, these devices are limited to a single invariable injection profile based on the impulse created by the compressed air or spring and therefore the parameters that affect injection are not well understood. To determine the effect of injection parameters on jet injection into tissue, including the effect of the fluid ejection profile on the injection, a controllable jet injection device was used to perform experiments into sheep and pig tissue. This paper demonstrates the importance of an initial peak in injection pressure and a subsequent lower follow-through pressure for successful jet injection into sheep and pig tissue
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 679-682
A Lorentz-Force Actuated Autoloading Needle-free Injector
The advantages of delivering injections via needle-free methods are numerous. However, conventional methods for needle-free injection lack sufficient control over depth of penetration and shape of injection. Thus, a needle-free injector was designed, constructed, and tested, using a controllable linear Lorentz-force actuator. This actuator allows rapid control of the injection pressure during injections. Using this device, precise control over delivery parameters can be achieved. The injector design was tested for repeatability and evaluated for depth control using acrylamide gel and dye
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 679-682
A Lorentz-Force Actuated Autoloading Needle-free Injector
The advantages of delivering injections via needle-free methods are numerous. However, conventional methods for needle-free injection lack sufficient control over depth of penetration and shape of injection. Thus, a needle-free injector was designed, constructed, and tested, using a controllable linear Lorentz-force actuator. This actuator allows rapid control of the injection pressure during injections. Using this device, precise control over delivery parameters can be achieved. The injector design was tested for repeatability and evaluated for depth control using acrylamide gel and dye